• Title/Summary/Keyword: Follicular Growth

Search Result 149, Processing Time 0.03 seconds

Optimized study of an in vitro 3D culture of preantral follicles in mice

  • Hehe Ren;Yingxin Zhang;Yanping Zhang;Yikai Qiu;Qing Chang;Xiaoli Yu;Xiuying Pei
    • Journal of Veterinary Science
    • /
    • v.24 no.1
    • /
    • pp.4.1-4.16
    • /
    • 2023
  • Background: In vitro culture of preantral follicles is a promising technology for fertility preservation. Objectives: This study aims to investigate an optimized three-dimensional (3D) fetal bovine serum (FBS)-free preantral follicle culture system having a simple and easy operation. Methods: The isolated follicles from mouse ovaries were randomly divided in an ultra-low attachment 96-well plates supplement with FBS or bovine serum albumin (BSA) culture or encapsulated with an alginate supplement with FBS or BSA culture. Meanwhile, estradiol (E2) concentration was assessed through enzyme-linked immunosorbent assay of culture supernatants. The diameter of follicular growth was measured, and the lumen of the follicle was photographed. Spindle microtubules of oocytes were detected via immunofluorescence. The ability of oocytes to fertilize was assessed using in vitro fertilization. Results: The diameters were larger for the growing secondary follicles cultured in ultra-low attachment 96-well plates than in the alginate gel on days 6, 8, and 10 (p < 0.05). Meanwhile, the E2 concentration in the BSA-supplemented medium was significantly higher in the alginate gel than in the other three groups on days 6 and 8 (p < 0.05), and the oocytes in the FBS-free system could complete meiosis and fertilization in vitro. Conclusions: The present study furnishes insights into the mature oocytes obtained from the 3D culture of the preantral follicle by using ultra-low attachment 96-well plate with an FBS-free system in vitro and supports the clinical practices to achieve competent, mature oocytes for in vitro fertilization.

Presence of Intact Cumulus Cells during In Vitro Fertilization Inhibits Sperm Penetration but Improves Blastocyst Formation In Vitro (돼지 난자의 체외 수정에 있어서 난구 세포의 존재가 정자 침투율 및 배 발육에 미치는 영향)

  • Yong, H.Y.;Lee, E.
    • Journal of Embryo Transfer
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • This study was conducted to examine the role of intact cumulus cells during in vitro fertilization (IVF) on sperm penetration, male pronuclear (MPN) formation and subsequent embryo development of oocytes matured and fertilized in vitro. Cumulus-oocyte complexes obtained from the slaughtered gilt ovaries were matured for 44 h in TCM199 containing 10% porcine follicular fluid, epidermal growth factor and hormones. After maturation culture, denuded oocytes or oocytes with intact cumulus cells were coincubated with frozen-thawed boar semen for 8h in a modified tris-buffered medium containing 5mM caffeine and 10mM calcium chloride. Putative zygotes were fixed and examined for sperm penetration and MPN formation (Experiments $1{\sim}3$), or cultured in North Carolina State University-23 medium fo. 156 h (Experiment 3). In Experiment 1, sperm penetration was examined after insemination of denuded oocytes and oocytes with intact cumulus cells at the concentration of $7.5{\times}10^5$ sperm/ml. Optimal sperm concentration for IVF of cumulus-intact oocytes was determined in Experiment 2 by inseminating intact oocytes with $2{\sim}5{\times}10^6$ sperm/ml. In Experiment 3, denuded or intact oocytes were inseminated at the concentrations of $7.5{\times}10^5$ and $4.0{\times}10^6$ sperm/ml, respectively, and in vitro embryo development was compared. Sperm penetration was significantly (p<0.01) decreased in cumulus-intact oocytes compared to denuded oocytes (35.2% vs. 77.4%). Based on the rates of sperm penetration and normal fertilization, the concentration of $4.0{\times}10^6$ sperm/ml was optimal for the IVF of intact oocytes compared to other sperm concentrations. The presence of intact cumulus cells during IVF significantly (p<0.05) improved embryo cleavage (48.8% vs. 58.9%), blastocyst (BL) formation (11.0% vs. 22.8%) and embryo cell number $(22{\pm}2\;vs.\;29{\pm}2\;cells)$ compared to denuded oocytes. In conclusion, these results suggest that intact cumulus cells during IVF inhibit sperm penetration but improve embryo cleavage, BL formation and embryo cell number of porcine embryos produced in vitro.

Expression of NGF in Estradiol Valerate-Induced Polycystic Ovary and CHO Cells (Estradiol Valerate에 의해 유도된 다낭성난소와 CHO세포에서 NGF발현)

  • Choi, Baik-Dong;Jeong, Soon-Jeong;Jeong, Moon-Jin;Lim, Do-Seon;Lee, Soo-Han;Kim, Seung-Hyun;Go, A-Ra;Kim, Se-Eun;Kang, Seong-Soo;Bae, Chun-Sik
    • Applied Microscopy
    • /
    • v.41 no.2
    • /
    • pp.109-116
    • /
    • 2011
  • Polycystic ovary syndrome (PCOS) is hormonal imbalance condition as the endocrine and metabolic disorder that induces the infertility and various complications in reproductive age women. Estradiol valerate (EV) is used hormone replacement therapy in menopausal women and is reported that excessive administration of EV induces the PCOS. Nerve growth factor (NGF) is the factor to regulate the survival and maturation of developing neuronal cell and is also synthesized in ovary. And NGF is overexpressed in EV-induced polycystic ovary (PCO) as previously reported. Therefore, this study examined the possibility of NGF as can be used the biological marker in diagnosis of PCOS, the hormonal imbalance condition, using PCO and CHO (chinese hamster ovarian) cell lines. The concentration of EV treatment is optimized a 1 mg as not influence on the proliferation of CHO cell but 2 mg and 3 mg of EV treatment have the inhibition effect at initial stage. The morphological change was not observed in CHO cell after dose dependent manner treatment of EV. Expression of NGF mRNA and protein is significantly increased at 30 min after EV treatment in CHO cells compared to that of control. And NGF protein expression is strongly increased in PCO tissue, which observed many follicular cysts compared to normal ovary tissue. Taken together, overexpression of NGF may be act as a molecule to induce an abnormal development of follicle, suggesting that NGF can be used as a biological marker in diagnosis of PCOS.

Radiation Therapy for Pituitary Adenoma -Changes in Endocrine Function after Treatment- (뇌하수체선종의 방사선치료후 혈중 호르몬치의 변화)

  • Yoon Sei Chul;Jang Hong Suck;Kim Song Hwan;Shinn Kyung Sub;Bahk Yong Whee;Son Ho Young;Kang Joon Ki
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.185-195
    • /
    • 1991
  • Seventy four patients with pituitary adenoma received radiation therapy (RT) on the pituitary area using 6 MV linear accelerator during the past 7 years at the Division of Radiation Therapy, Kangnam St. Mary's Hospital, Catholic University Medical College. Thirty nine were men and 35 were women. The age ranged from 7 to 65 years with the mean being 37 years. Sixty five ($88\%$) patients were treated postoperatively and 9 ($12\%$) primary RT, To evaluate the effects of RT, we analyzed the series of endocrinologic studies with prolactin (PRL), growth hormone (GH), adrenocorticotrophic hormone (ACTH), leuteinizing hormone (LH), follicular stimulating hormone (FSH) and thyroid stimulating hormone (TSH) etc after RT. All but one with Nelson's syndrome showed abnormal neuroradiologic changes in the sella turcica with invasive tumor mass around supra- and/or parasella area. The patients were classified as 23 ($29\%$) prolactinomas and 20 ($26\%$) growth hormone (GH) secreting tumors, and 6 ($8\%$ ACTH secreting ones consisting of 4 Cushing's disease and 2 Nelson's syndrome. Twentynine ($37\%$) had nonfunctioning tumor and four ($5\%$) of those secreting pituitary tumors were mixed PRL-GH secreting tumors. The hormonal level in 15 ($65\%$) of 23 PRL and 3 ($15\%$) of 20 GH secreting tumors returned to normal by 2 to 3 years after RT, but five PRL and five GH secreting tumors showed high hormonal level requiring bromocriptine medication. Endocrinologic insufficiency developed by 3 years after RT in 5 of 7 panhypopituitarisms, 4 of seven hypothyroidisms and one of two hypogonadisms, respectively. Fifteen ($20\%$) patients were lost to follow up after RT.

  • PDF

Reproductive Cycle of Small Filefish, Rudarius ercodes (그물코쥐치, Rudarius ercodes의 생식주기)

  • LEE Taek Yuil;HANYU Isao
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.5
    • /
    • pp.423-435
    • /
    • 1984
  • The reproductive cycle of the small filefish, Rudarius ercodes was investigated based on the annual variations of gonadosomatic index(GSI) and hepatosomatic index(HSI) by electronic and photic microscophy. The specimens used were collected at the coastal area of Benden island, Sizuokagen, Japan, from September 1982 to August 1983. GSI began to increase from March, starting season of longer daylength and higher water temperature, and reached the maximum value between June and August. It began to decrease from September with the lowest value appearing between November and February without any evident variation. The annual variations of HSI were not distinct in male filefish and were negatively related to GSI in female : HSI decreased in the summer season when the ovary was getting mature and reached the maximum in the winter season when the ovary was getting retrogressive. The ovary consisted of a pair of saccular structure with numerous ovarian sacs branched toward the median cavity. Oogonia divided and proliferated along the germinal epithelium of the ovarian sac. Young oocytes with basophile cytoplasm showed several scattering nucleoli along the nuclear membrane. when the oocytes growing to about 300 ${\mu}m$, nuclear membrane to disappear with nucleus migrating toward the animal pole. The regions of protoplasm were extremely confined within the animal hemisphere in which most of cytoplasms were filled with yolk materials and oil drops. After ovulation, residual follicles and growing oocytes remaining in the ovarian sacs degenerated. But perinucleatic young oocytes without follicles formed were not degenerated, and growing continuously still in the next year. Mitochondria and endoplasmic reticula in the cytoplasm remarkably increased with oocytes maturing and yolk accumulating. Those were considered to be functionally related to the yolk accumulation. Five or six layers of possible vitellogenin, oval-shaped disc structures with high electron density, appeared in the apex of follicular processes stretching to the microvilli pits of mature oocytes. Testis consisting of a pair of lobular structures in the right and left were united in the posterior seminal vesicle, Cortex of testis was composed of several seminiferous tubules, and medulla consisting of many sperm ducts connected with tubules. Steroid hormone-secreting cells with numerous endoplasmic reticula and large mitochondria of well developed cristae were recognized in the interstitial cells of the growing testis. Axial filament of spermatozoon invaginated deeply in the central cavity of the nucleus and the head formed U-shape with acrosome severely lacking, mitochondria formed large globular paranuclei at the posterior head, and microtubular axoneme of the tail represented 9+9+2 type. The annual reproductive cycles could be divided into five successive stages : growth(March to July), maturation(May to September), Spawning(mid May to early October) and resting stages(October to February). The spawning peak occurred from June to August.

  • PDF

Studies on the Early Development of the Mouse Embryo Transplanted in the Anterior Chamber of the Eye (眼前房내에 이식한 생쥐배의 초기발생에 관한 연구)

  • Cho, Wan Kyoo;Kim, Moon Kyoo
    • The Korean Journal of Zoology
    • /
    • v.15 no.1
    • /
    • pp.25-33
    • /
    • 1972
  • Two-Cell mouse embryos were incubated in the anterior chamber of the rat eye, which has been known as the best place among other animals' for the mouse ovum maturation, in order to observe the capability of their early development. Within 120 hours after incubation, 71.0% of two-cell embryos have developed to the blastocysts in the male rat eye, while only 38.5% in the eye of the same mouse as donated two-cell embryos. Thus, the rat eye chamber provides more favourable environment to the embryos than the mouse itself. The results are consistent with those of the previous studies comparing the maturation of the mouse follicular oocytes in the mouse and the rat eye chamber. Although the aqueous humor which is filled in the anterior chamber of the eye is characterized by its specific properties, being of higher osmolarity, higher concentrations of ascorbic acid, pyruvate and lactate, but lower of proteins and lower temperature than those in blood or lymph serum, The embryos are able to under-take their cleavage as normal as in vivo or in vitro. Concerning with a number of studies in vitro on the development of the mouse embryos which are requiring a very limited condition, the fact that they are able to manage their further development under very different enviroment from our knowledges would provide us a moment to understand their behavior during the early development. The difference of the proportion of the developed blastocysts between in the mouse eye chamber and in the rat can possibly be resulted from the species specific difference in the physicochemical properties between their eye chambers. This assumption is based upon the findings by many investigators who chmpared the nature of the eye chamber of various animals. As a consequence, the rat eye chamber might consist of better properties for the embryonal growth than the mouse eye chamber. The mouse embryos cleaved with a delayed period. In normal development they complete almost the cleavage within 94 hours after fertilization. However, in the present studies, 81.1% of two-cell embryos developed to the blastocysts and the morula in 120 hours in the eye chamber, assumed to be about 154 hours after fertilization. Such delay in development would be caused mainly by the low temperature of the eye chamber. At present we can make two assumptions to explain the capability of the emtryonal development in the eye chambers. One is that the embryos would possess an ability to adapt themselves to the environment which provides unfavourable conditions. The other is that the embryos might remain for a certain duration in the eye chamber, which is filled with a new body fluid produced immediately after the loss of the aqueous humor and the fluid of which becomes similar to blood serum in component. The first assumption is highly reliable since the embryonal cells are mostly at the undifferentiated state and so they probably engage a simple metabolism during their early period. The second assumption is induced by the fact that the rabbit eye chamber produces a plasmoid humor which has mostly similar components to blood serum after loss of aqueous humor through cornea by puncturing. However, the plasmoid humor is substituted by the initial aqueous humor in eight hours. Even though this finding, production of the new fluid, could be applied to the rat eye, it is hardly reliabel that the plasmoid humor remains for such a long period as 120 hours. Consequently, the development of the embryos is more likely due to their adaptability to the new environment during their early developmental stages.

  • PDF

Clinical Efficacy of Clomiphene Citrate and Letrozole Combined with Gonadotropins for Superovulation in Patients with Clomiphene-Induced Thin Endometrium (클로미펜에 얇은 자궁내막을 보이는 환자에서 성선자극호르몬 병합 과배란유도시 클로미펜과 레트로졸의 임상적 효용성)

  • Lee, Eun-Joo;Park, Hyun-Jong;Yang, Hyo-In;Lee, Kyung-Eun;Seo, Seok-Kyo;Kim, Hye-Yeon;Cho, Si-Hyun;Choi, Young-Sik;Lee, Byung-Seok;Park, Ki-Hyun;Cho, Dong-Jae
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.2
    • /
    • pp.111-119
    • /
    • 2009
  • Objective: The aim of this study was to compare the clinical efficacy of clomiphene citrate (CC) and letrozole combined with gonadotropins for controlled ovarian stimulation (COS) in patients with CC-induced thin endometrium Methods: Fifty-one intrauterine insemination cycles performed in patients who previously had a thin endometrium (<8 mm) to ovulation induction using CC were included in this study. A CC 100 mg/day (CC+gonadotropin group, n=26) or letrozole 2.5 or 5 mg/day (letrozole+gonadotropin group, n=25) was administered on day 3~7 of the menstrual cycle, combined with gonadotropins at dose 75~150 IU every other day starting on day 5~7. We compared total dose of gonadotropin used, endometrial thickness, endometrial pattern, number of follicles ${\geq}14\;mm$ on hCG day, pregnancy rate and multiple pregnancy rate between the two groups, which were statistically analyzed using Mann-Whitney U test or Fisher's exact test, where appropriate. Results: There were no significant differences in clinical characteristics such as age, duration of infertility, number of previous IUI cycles, basal serum hormone levels and cause of infertility between the two groups. In both groups, the endometrium was significantly thicker than that of previous ovulation induction cycles using CC. No significant differences were found in the total dose of gonadotropin used, day of hCG administration, the rate of triple endometrium and pregnancy rate. The number of follicles ${\geq}14\;mm$ was significantly lower ($3.7{\pm}1.7$ vs. $2.8{\pm}1.7$, p=0.03) and the endometrium on hCG day was significantly thicker ($7.7{\pm}1.5$ vs. $9.1{\pm}1.7$, p=0.001) in letrozole+gonadotropin group compared to CC+gonadotropin group. Conclusion: The clomiphene citrate and letrozole combined with gonadotropins appear to avoid the undesirable effects on the endometrium frequently seen with CC for ovulation induction. However, in terms of adequate endometrial development or optimal follicular growth, letrozole may be more beneficial than CC for gonadotropin-combined COS in patients with CC-induced thin endometrium. Further prospective randomized controlled studies in a larger scale will be necessary to confirm our findings.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF