Effect of waste glass as powder and aggregate on strength and shrinkage of fiber reinforced foam concrete

  • Mayada A. Kareem;Ameer A. Hilal
    • Advances in materials Research
    • /
    • 제12권4호
    • /
    • pp.331-349
    • /
    • 2023
  • Foam concrete can be considered as environmental friendly material due to its low weight, its minimal cost and a possibility to add waste materials in its production. This paper investigates the possibility of producing foam concrete with waste glass as powder and aggregate. Then, the effect of using waste glass on strength and drying shrinkage of foam concrete was examined. Also, the effect of incorporating polypropylene fibers (12 mm length and proportion of 0.5% of a mix volume) on distribution of waste glass as coarse particles within 1200 kg/m3 foam concrete mixes was evaluated. Waste glass was used as powder (20% of cement weight), as coarse particles (25%, 50% and 100% instead of sand volume) and as fine particles (25% instead of sand volume). From the results, the problem of non-uniform distribution of coarse glass particles was successfully solved by adding polypropylene fibers. It was found that using of waste glass as coarse aggregate led to reduce the strength of foam concrete mixes. However, using it with polypropylene fibers in combination helped in increasing the strength by about 29- 50% for compressive and 55- 71% for splitting tensile and reducing the drying shrinkage by about (31- 40%). In general, not only the fibers role but also the uniformly distributed coarse glass particles helped in improving and enhancing the strength and shrinkage of the investigated foam concrete mixes.

물유리코팅에 따른 폴리우레탄 폼의 난연성능 개선에 대한 연구 (Improvement of Flame-Retardant Performance of Polyurethane Foam Coated with Water Glass)

  • 김형준;박제원;나혜인;임형미;장가빈
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.7-13
    • /
    • 2020
  • 경질 폴리우레탄(Polyurethane) 폼(Foam)의 난연 성능을 개선하기 위하여 외부에 물유리를 코팅하였다. 무기질인 물유리 코팅층이 적용된 우레탄폼의 콘칼로리메터의 열방출율(Heat release rate)은 급격히 감소하였다. 폴리우레탄 표면에 코팅된 물유리는 화염에 노출되었거나 가열되었을 때 유리화 반응과 미 탈출 수분에 의한 발포현상으로 인해 유리질 폼을 형성하게 된다. 폴리우레탄 폼 위에 형성된 유리질 폼은 단열층이 되어 10 min 이상 폴리우레탄 폼의 연소를 억제하였다. 이러한 결과에 따라서 물유리는 경질 폴리우레탄 폼의 난연 특성을 개선할 수 있음을 확인하였다.

단열바닥기초 적용을 위한 발포유리 골재의 기초 특성 평가 (A Study on the Basic Properties of Foam Glass Aggregate for the Application of Insulated Foundation)

  • 김상헌;문수영;김현수
    • 한국건설순환자원학회논문집
    • /
    • 제10권4호
    • /
    • pp.420-427
    • /
    • 2022
  • 본 연구는 국내 생산 발포유리 골재를 활용하여 단열바닥기초로 활용하기 위해, 발포유리 골재로 구성된 단열부의 물리역학적 특성 및 열적특성을 평가하였다. 평가 결과, 압축강도는 기존 유기단열재인 XPS, EPS 등에 비해 높은 40.6 N/cm2로 나타났으며, 열전도율은 0.84 W/mK로 나타났다. 또한 단열바닥구조를 모사한 시험체의 열관류율은 0.37 W/m2K로 나타나 실제 발현되는 발포유리 골재의 열전도율은 0.80 W/mK으로 평가되었다. 본 연구를 통해 발포유리 골재를 사용한 단열바닥구조의 활용가능성을 확인할 수 있었다.

수광재와 백토조합물에서의 기포형성에 관한 연구 (The Study on Foam Formation in Waterslag-Bentonite System)

  • 김종희;송한식
    • 한국세라믹학회지
    • /
    • 제14권4호
    • /
    • pp.248-255
    • /
    • 1977
  • The effect of firing temperature, soaking time and batch composition upon the glass phase and pore formation as well as their distribution in slag foamed glass was investigated. Sulfur dioxide gas produced by the oxidation and reduction of metal sulfide in waterslag was attributed to foam forming agent. Slag foamed glass matrix was mainly composed of 35~60% glas phase and melilite crystalline phase. The increment of bentonite addition in batch lowered the foam forming temperature in studied system. The result showed also that the foam size distribution was broadened as th firing temperature wa inbereased.

  • PDF

Mechanical behaviour of a syntactic foam/glass fibre composite sandwich: experimental results

  • Papa, Enrico;Corigliano, Alberto;Rizzi, Egidio
    • Structural Engineering and Mechanics
    • /
    • 제12권2호
    • /
    • pp.169-188
    • /
    • 2001
  • This note presents the main results of an experimental investigation into the mechanical behaviour of a composite sandwich conceived as a lightweight material for naval engineering applications. The sandwich structure is formed by a three-dimensional glass fibre/polymer matrix fabric with transverse piles interconnecting the skins; the core is filled with a polymer matrix/glass microspheres syntactic foam; additional Glass Fibre Reinforced Plastics extra-skins are laminated on the external facings of the filled fabric. The main features of the experimental tests on syntactic foam, skins and sandwich panels are presented and discussed, with focus on both in-plane and out-of-plane responses. This work is part of a broader research investigation aimed at a complete characterisation, both experimental and numerical, of the complex mechanical behaviour of this composite sandwich.

현무암 섬유 보강 폴리우레탄폼의 열적 성능 및 극저온 환경에서의 기계적 특성 평가 (Evaluation of Thermal Performance and Mechanical Properties in the Cryogenic Environment of Basalt Fiber Reinforced Polyurethane Foam)

  • 전성규;김정대;김희태;김정현;김슬기;이제명
    • 대한조선학회논문집
    • /
    • 제59권4호
    • /
    • pp.207-213
    • /
    • 2022
  • LNG CCS which is a special type of cargo hold operated at -163℃ for transporting liquefied LNG is composed of a primary barrier, plywood, insulation panel, secondary barrier, and mastic. Currently, glass fiber is used to reinforce polyurethane foam. In this paper, we evaluated the possibility of replacing glass fiber-reinforced polyurethane foam with basalt fiber-reinforced polyurethane foam. We conducted a thermal conductivity test to confirm thermal performance at room temperature. To evaluate the mechanical properties between basalt and glass-fiber-reinforced polyurethane foam which is fiber content of 5 wt% and 10 wt%, tensile and an impact test was performed repeatedly. All of the tests were performed at room temperature and cryogenic temperature(-163℃) in consideration of the temperature gradient in the LNG CCS. As a result of the thermal conductivity test, the insulating performance of glass fiber reinforced polyurethane foam and basalt fiber reinforced polyurethane foam presented similar results. The tensile test results represent that the strength of basalt fiber-reinforced polyurethane foam is superior to glass fiber at room temperature, and there is a clear difference. However, the strength is similar to each other at cryogenic temperatures. In the impact test, the strength of PUR-B5 is the highest, but in common, the strength decreases as the weight ratio of the two fibers increases. In conclusion, basalt fiber-reinforced polyurethane foam has sufficient potential to replace glass fiber-reinforced polyurethane foam.

반복 충격이 유리섬유 강화 폴리우레탄 폼의 기계적 성능에 미치는 영향 (Effect of Repetitive Impacts on the Mechanical Behavior of Glass Fiber-reinforced Polyurethane Foam)

  • 김명성;김정현;김슬기;이제명
    • 한국해양공학회지
    • /
    • 제33권1호
    • /
    • pp.85-91
    • /
    • 2019
  • In a cryogenic storage structure, the insulation system is in an environment in which fluid impact loads occur throughout the lifetime of the structure. In this study, we investigated the effect of repetitive impact loading on the mechanical performance of glass fiber-reinforced polyurethane foam. The repeated impact loading test was conducted in accordance with the required impact energy and the required number of repetitive impacts. The impact behavior of glass fiber-reinforced polyurethane foam was analyzed in terms of stress and displacement. After the impact test, the specimen was subjected to a compression test to evaluate its mechanical performance. We analyzed the critical impact energy that affected mechanical performance. For the impact conditions that were tested, the compressive strength and elastic modulus of the polyurethane foam can be degraded significantly.

Sound Absorbing Melamine Foam: A Strong Environmental Friendly Tendency Opposing Glass Fiber of Room Using in China

  • Yan, Xiang
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.462-462
    • /
    • 2010
  • Glass fiber is widely used in architectural acoustics or building acoustics for sound absorption since it was introduced into China for about 50 years. But recent years, with people pay more attentions to the air cleansing and their health which may be affected by the tiny fiber of the glasswool, a voluntary tendency opposing glass fiber of room using is gradual appeared in China. This paper discusses both the main opinions towards the question whether there are harmful impacts on people health from glassfiber, and the application circumstance of it's applying in china. This paper focuses on another substitute sound absorbing material, melamine foam, to discuss the strong environmental friendly tendency opposing glass fiber of room using in China now.

  • PDF

차량용 단열재의 종류에 따른 난연성 평가 (Flammability of insulators for railroad vehicles)

  • 이덕희;이철규;정우성;김선옥;백민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.477-482
    • /
    • 2004
  • New materials are being considered for insulator of railroad vehicles. Because people want more environmental material than glass fiber, there are certain needs of finding safe and economical insulating material. We checked the flammability of some kinds insulators such as PE foam, neoprene rubber foam. melamine foam and glass fiber. You could find out the characteristics such as oxygen index. optical smoke density, toxicity index of that insulators.

  • PDF

발포유리 혼합기포 콘크리트의 바닥충격음 차단성능 영향에 관한 연구 (The Effect of Aerated Concrete containing Foam Glass Aggregate on the Floor Impact Sound Insulation)

  • 윤창연;정정호;김명준
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.414-422
    • /
    • 2013
  • As structure-borne sound, the floor impact sound is one of the serious noises in residential building. Most of heating system applied to the typical Korean residential building is floor heating system which is called ondol. The ondol usually consists of finishing material, mortar with heating coil, light-weight aerated concrete and reinforced concrete. This study focused on the isolation of heavy-weight impact sound and modification of mortar and light-weight aerated concrete. Specifically the glass foam aggregate was added on light-weight aerated concrete. Also, water-cement ratio and amount of cement on mortar were revised. The sound pressure level of heavy-weight impact was measured in reverberation chamber using both bang-machine and impact ball. The size of specimen was 1 m by 1 m. Substitution ratio of glass foam aggregate on light-weight aerated concrete shows relationship with heavy-weight impact sound pressure level. In addition, heavy-weight impact sound pressure level was decreased with increment of water-cement ratio and amount of cement on mortar.