• 제목/요약/키워드: Fluxes

검색결과 1,226건 처리시간 0.026초

수냉식 수직평판 흡수기의 액막 열 및 물질전달에 관한 수치적 연구 (Numerical Study on Simultaneous Heat and Mass Transfer in a Falling Film of Water-Cooled Vertical Plate Absorber)

  • ;문춘근;김은필;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.593-602
    • /
    • 2004
  • This paper is a study on the model of simultaneous heat and mass transfer process in the absorption of refrigerant vapor into a lithium bromide solution of water-cooled vertical plate absorber. The model can predict temperature and concentration profiles as well as the effect of Reynolds number on them. Also. the variations of the absorption heat and mass fluxes. and the heat and mass transfer coefficients have been investigated. The numerical result shows that the interface temperature and concentration decrease as film Reynolds number does. The absorption heat and mass fluxes, and the heat and mass transfer coefficients get their maximum values adjacent to the inlet solution. Analyses on a constant wall temperature condition have been also carried out to exam the reliability of the present numerical method by comparing to previous investigations.

Some Aspects of Experimental in-Tube Evaporation

  • Ha, Sam-Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제14권5호
    • /
    • pp.537-546
    • /
    • 2000
  • The heat transfer characteristics of refrigerant-oil mixture for horizontal in-tube evaporator have been investigated experimentally. A smooth copper tube and a micro-fin tube with nominal 9.5 mm outer diameter and 1500 mm length were tested. For the pure refrigerant flow, the dependence of the axial heat transfer coefficient on quality was weak in the smooth tube, but in the micro-fin tube, the coefficients were 3 to 10 times greater as quality increases. Oil addition to pure refrigerant in the smooth tube altered the flow pattern dramatically at low mass fluxes, with a resultant enhancement of the wetting area by vigorous foaming. The heat transfer coefficients of the mixture for low and medium qualities were increased at low mass fluxes. In the micro-fin tube, however, the addition of oil deteriorates the local heat transfer performance for most of the quality range, except for low quality. The micro-fin tube consequently loses its advantage of high heat transfer performance for an oil fraction of 5%. Results are presented as plots of local heat transfer coefficient versus quality.

  • PDF

Mercury Exchange Flux from Two Different Soil Types and Affecting Parameters

  • Park, Sang-Young;Kim, Pyung-Rea;Han, Young-Ji
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권4호
    • /
    • pp.199-208
    • /
    • 2013
  • Mercury exchange fluxes between atmosphere and soil surface were measured in two different types of soils; lawn soil (LS) and forest soil (FS). Average Hg emission from LS was higher than from FS although the soil Hg content was more than 2 times higher in forest soil. In LS, Hg emissions were much greater in warm season than in cold season; however, deposition was dominant in FS during warm season because of leafy trees blocking the solar radiation reaching on the soil surface. In both LS and FS, Hg fluxes showed significantly positive correlations with UV radiation and soil surface temperature during cold season. In addition, it was observed that emission showed positive correlation with UV radiation and soil temperature while there was negative relationship between deposition and UV radiation.

사각 채널에서의 강제대류 열전달 (Forced convective Heat Transfer in rectangular channel)

  • 임태우;유삼상
    • 동력기계공학회지
    • /
    • 제16권4호
    • /
    • pp.37-43
    • /
    • 2012
  • This paper performed experimental research in order to measure boiling heat transfer coefficient of water in microchannel with hydraulic diameter of $500{\mu}m$. Tests were conducted within the ranges of heat fluxes from 100 to 400 kW/$m^2$, vapor qualities from 0 to 0.2, and mass fluxes of 200, 400, and 600 kg/$m^2s$. From the experimental results, it was found that flow boiling heat transfer coefficient is not dependent on mass flux or vapor quality, but instead on heat flux to a certain degree. The measured data of heat transfer are compared to a few available correlations proposed for mini-channels. Among them, Sun and Mishima's correlation is found to predict the present data well, within the mean absolute error of 17.84%.

Distribution of Fluorescent Whitening Agents as an Indicator of Domestic Wastewater

  • Okumura, Ryouji;Yamamoto, Hiroki;Fujiwara, Manabu;Hayakawa, Kazuhide
    • 생태와환경
    • /
    • 제38권spc호
    • /
    • pp.62-66
    • /
    • 2005
  • The distributions of fluorescent whitening agents (FWA) in the water of the Yasu River and their tributaries flowing into Lake Biwa (Japan) were surveyed on winter and summer. The FWA fluxes had linear correlation with the corrected resident population in catchments of the tributaries of Yasu River. Therefore, the FWAs in the rivers come from domestic wastewater, and those fluxes in the tributaries depended on the human population of their catchments. As an application of the FWA indicating domestic wastewater, we could assess seasonal changes in the sources of dissolved organic matter in the tributaries.

센서리스 유도전동기를 위한 새로운 슬라이딩 모드 관측기의 설계 (Design of a New Adaptive Sliding Mode Observer for Sensorless Induction Motor Drive)

  • 김상민;한우용;김성중
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권10호
    • /
    • pp.522-527
    • /
    • 2003
  • This paper proposes a new speed and flux estimation method which has the robustness against the variation of the electrical parameters of the motor and the superiority in the dynamic characteristics. In the proposed method, the stator currents and the rotor fluxes are observed on the stationary reference frame using the sliding mode concept. And the rotor speed is estimated using the current estimation errors and the observed rotor fluxes based on the Lyapunov stability theory. Also a design method of the observer gain is proposed to minimize the effect of the speed estimation error on the rotor flux observation. The experimental results are shown to verify that the proposed method shows the excellent performances under the variations of motor resistance and inductance.

Epithermal Neutron Flux Enhancement Using SMA in Designing a Cf-Based Neutron Beam for BNCT

  • Kim, Do-Heon;Kim, Jong-Kyung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.937-942
    • /
    • 1995
  • Great interest has prompted Boron Neutron Capture Therapy (BNCT) as a new treatment for brain tumors. The use of $^{252}$Cf as a neutron source for BNn makes the in-hospital treatments of tumors to be possible. Newly proposed subcritical multiplying assemblies (SMA) are explored to improve relatively tow neutron fluxes of the source and construct the feasibilities of $^{252}$Cf as a neutron source. The MCNP code has been used to evaluate the effective multiplication factor of the entire system and the intensities and percentages of epithermal neutron flux at the patient-end surface of the system. The neutron beam using SMA shows the epithermal neutron flux enhancement of about 13 times as large as the beam without using SMA. It is expected that the neutron beam proposed in this research will be more effective for treatment of tumors due to the increased therapeutic neutron fluxes.

  • PDF

농림생태계와 대기간의 상호 작용 연구를 위한 에디 공분산 방법의 사용에 관하여 (On Using the Eddy Covariance Method to Study the Interaction between Agro-Forest Ecosystems and the Atmosphere)

  • 최태진;김준;윤진일
    • 한국농림기상학회지
    • /
    • 제1권1호
    • /
    • pp.60-71
    • /
    • 1999
  • The micrometeorological tower flux network is the cornerstone of the global terrestrial vegetation monitoring. The eddy covariance technique used for tower fluxes is derived from the conservation of mass and is most applicable for steady-state conditions over flat, extended, and uniform vegetation. This technique allows us to obtain surface fluxes of energy budget components, greenhouse and trace gases, and other pollutants. The quality-controlled flux data are invaluable to validate various models with temporal scales ranging from minutes to years and spatial scales ranging from a few meters to hundreds of kilometers. In this paper, we review the theoretical background of this important eddy covariance technique, examine the measurement criteria and corrections, and finally suggest some measurement strategies that may facilitate coordinated flux measurements among different disciplines and provide a strong infrastructure for the global flux network.

  • PDF

턴디쉬용 MgO Coating 재의 손상에 미치는 Flux의 영향 (Effect of Fluxes on the Wear of MgO Coating Materials for Tundish)

  • 홍기곤;박재원;김효준
    • 한국세라믹학회지
    • /
    • 제34권7호
    • /
    • pp.677-684
    • /
    • 1997
  • The effects of fluxes on MgO coating materials for tundish were investigated. As the number of charge in continuous casting was increased, the basicity of tundish slag was decreased due to the increase of silica formed by dissolution from rice hull. As a result, the wear of magnesia lining was increased. In aggregates of MgO coating materials, magnesioferrite was formed by the reaction between magnesia and ferric oxide formed by the oxidation of molten steel, while matrix parts of MgO coating materials were worn by CaO-Al2O3-SiO2 compounds. Silica in rice hull extracted to the molten slag reduced basicity of slag and formed forsterite in the result of its reaction with magnesia lining. Also, fayalite was formed from the reaction between silica and ferric oxide and it caused the increment of magnesia lining's wear. The wear of magnesia lining by flux of CaO-SiO2 was larger than that of Cao-Al2O3 and calcia in the flux increased the wear of magnesia lining through the formation of rankinite.

  • PDF

Host galaxy of tidal disruption object, Swift J1644+57

  • Yoon, Yongmin;Im, Myungshin;Lee, Seong-Kook;Pak, Soojong
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.48.2-48.2
    • /
    • 2014
  • We present long-term optical to NIR data of the tidal disruption object, Swift J1644+57. The data were obtained with CQUEAN, UKIRT WFCAM observations. We analyze the morphology of the host galaxy of this object and decompose the bulge component using high resolution HST WFC3 images. We conclude that the host galaxy is bulge dominant. We also estimate the multi-band fluxes of the host galaxy through the light curves based on the long-term observational data. We fit the SED models to the multi-band fluxes of the host galaxy and determine its stellar mass. Finally, we estimate the mass of the central super massive black hole which is responsible for the tidal disruption event. The estimated stellar mass and black hole mass are ${\sim}10^{9.1}M_{\odot}$, ${\sim}10^{6.8}M_{\odot}$, respectively. We compare our results to other previous estimates.

  • PDF