• Title/Summary/Keyword: Flux-Flow

Search Result 1,677, Processing Time 0.027 seconds

A numerical study of flow and heat transfer characteristics varied by impingement jet in turbine blade cooling (터빈블레이드의 냉각에서 충돌제트에 의해 변화되는 유동 및 열전달 특성에 관한 수치해석적 연구)

  • Lee, Jeong-Hui;Kim, Sin-Il;Yu, Hong-Seon;Choe, Yeong-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.12
    • /
    • pp.4013-4026
    • /
    • 1996
  • A numerical simulation has been carried out for the jet impinging on a flat plate and a semi-circular concave surface. In this computation finite volume method was employed to solve the full Navier-Stokes equation based on a non-orthogonal coordinate with non staggered variable arrangement. The standard k-.epsilon. turbulent model and low Reynolds number k-.epsilon. model(Launder-Sharmar model) with Yap's correction were adapted. The accuracy of the numerical calculations were compared with various experimental data reported in the literature and showed good predictions of centerline velocity decay, wall pressure distribution and skin friction. For the jet impingement on a semi-circular concave surface, potential core length was calculated for two different nozzle(round edged nozzle and rectangular edged nozzle) to consider effects of the nozzle shape. The result showed that round edged nozzle had longer potential core length than rectangular edged nozzle for the same condition. Heat transfer rate along the concave surface with constant heat flux was calculated for various nozzle exit to surface distance(H/B) in the condition of same jet velocity. The maximum local Nusselt number at the stagnation point occurred at H/B = 8 where the centerline turbulent intensity had maximum value. The predicted Nusselt number showed good agreement with the experimental data at the stagnation point. However heat transfer predictions along the downstream were underestimated. This results suggest that the improved turbulence modeling is required.

The Effect of the Fill Charge Ratio on the Heat Transfer Characteristics of a Two-Phase Closed Thermosyphon (충전율의 변화가 밀폐형 2-상 열사이폰의 열전달 특성에 미치는 영향에 관한 연구)

  • Park, Yong-Joo;Hong, Sung-Eun;Kim, Chul-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.12
    • /
    • pp.1646-1654
    • /
    • 2002
  • A two-phase closed thermosyphon was one of the most effective devices in the removing heat because of its simple structure, thermal diode characteristics, wide operating temperature range and so on. In this study, a two-phase closed thermosyphon(working fluid PFC(C6F14), container copper(inner grooved surface)) was fabricated with a reservoir which can change the fill charge ratio. The experiments were performed in the range of 50~600W heat flow rate and 10~70% fill charge ratio. The results were compared with some correlations that were presented by Rohsenow and Immura et al. in the evaporator, by Nusselt, Gross and Uehara et al. in the condenser and by Cohen and Bayley, Wallis, Kutateladze and Faghri et al. in heat transfer limitation etc.. The heat transfer coefficient at the evaporator increased with the input power. However the effect of the fill charge ratio was nearly negligible. At the condenser, it showed an opposite trend to the evaporator and with increase of the fill charge ratio, showed some enhancement of heat transfer. The heat transport limitation was occurred by the dry-out limitation for small fill charge ratio(10%) and presented about 100W. For the case of large fill charge ratio(Ψ$\geq$40%), it was occurred by the flooding limitation at about 500W.

Numerical Analysis of Heat Transfer in Multichannel Volumetric Solar Receivers (다채널 체적식 태양열 흡수기에서 열전달 수치해석)

  • Lee, Hyun-Jin;Kim, Jong-Kyu;Lee, Sang-Nam;Kang, Yong-Heack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1383-1389
    • /
    • 2011
  • The current study focuses on the consistent analysis of heat transfer in multichannel volumetric solar receivers used for concentrating solar power. Changes in the properties of the absorbing material and channel dimensions are considered in an optical model based on the Monte Carlo ray-tracing method and in a one-dimensional heat transfer model that includes conduction, convection, and radiation. The optical model results show that most of the solar radiation energy is absorbed within a very small channel length of around 15 mm because of the large length-to-radius ratio. Classification of radiation losses reveals that at low absorptivity, increased reflection losses cause reduction of the receiver efficiency, notwithstanding the decrease in the emission loss. As the average temperature increases because of the large channel radius or small mass flow rate, both emission and reflection losses increase but the effect of emission losses prevails.

Resistance Development in Au/YBCO Thin Film Meander Lines under High-Power Fault Conditions (과도 사고 시 Au/YBCO 박막 곡선의 저항 거동)

  • Kim, H.R.;Sim, J.;Choi, I.J.;Yim, S.W.;Hyun, O.B.
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.81-86
    • /
    • 2006
  • We investigated resistance development in $Au/YBa_2Cu_3O_7(YBCO)$ thin film meander lines during high-power faults. The meander lines were fabricated by patterning 300 nm thick YBCO films coated with 200 nm thick gold layers into meander lines. A gold film grown on the back side of the substrate was also patterned into a meander line. The front meander line was connected to a high-power fault-test circuit and the back line to a DC power supply. Resistance of both lines was measured during the fault. They were immersed in liquid nitrogen during the experiment. Behavior of the resistance development prior to quench completion could be understood better by comparing resistance of the front meander lines with that of the back. Quench completion point could be determined clearly. Resistance and temperature at the quench completion point were not affected by applied field strength. The experimental results were analyzed quantitatively with the concept of heat transfer within the meander lines/substrate and to the surrounding liquid nitrogen. In analysis, the fault period was divided into three regions: flux-flow region, region prior to quench completion, and region after quench completion. Resistance was calculated for each region, reflecting the observation for quench completion. The calculated resistance in three regions was joined seamlessly and agreed well with data.

  • PDF

Domination of glassy and fluctuation behavior over thermal activation in vortex state in $MgB_2$ thin film ($MgB_2$ 박막에서의 열적 활성화에 비해 두드러진 볼텍스 유리화 및 열적 요동현상의 연구)

  • Kim, Heon-Jung;W. N. Kang;Kim, Hyeong-Jin;Park, Eun-Mi;Kim, Kijoon H. P.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.23-27
    • /
    • 2001
  • We have investigated the mixed-state magnetoresistance of high quality c-axis-oriented MgB2 thin film for magnetic field from 0.5 T to 5.0 T, applied normal to ab-plane. The temperature dependence of magnetoresistance was well described by vortex glass and fluctuation theories for different temperature regimes. We observed glassy exponent of v(z-1)~3 and upper critical field of $H_{c2}$(0)~35 T, which is consistent with previous data obtained from direct $H_{c2}$(0) measurements. Interestingly, the thermally activated flux flow region was observed to be very narrow, suggesting that the pinning strength of this compound is very strong. This finding is closely related to the recent reports that the bulk pinning is dominant in $MgB_2$and the critical current density of $MgB_2$ thin film is very high, comparable to that of cuprate superconductor. The present results further suggest that $MgB_2$is beneficial to technical applications.ons.

  • PDF

A Study on Film Boiling Heat Transfer in a Forced Convective Flow System (강제대류계(强制對流系)에 있어서 막비등열전달(膜沸騰熱傳達)에 관한 연구(硏究))

  • Kim, Y.T.;Kwon, S.S.;Jung, D.I.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.51-60
    • /
    • 1991
  • The aim of this study is to investigate the heat transfer characteristics in the transient cooling process of a high temperature wall. The slow transient cooling experiment was carried out with a copper block of high thermal capacity. The results of these experiments are as follows. 1. Temperature histories measured by the thermocouple, which is 0.99, 2.00, 2.99mm from the heat transfer surface showed monotonous during the cooling process. These variation are the curves of typical temperature histories in film-boiling, transition-boiling, and nucleate-boiling regions. 2. The temperature histories were measured by thermocouple installed in the copper block. The variations of the surface heat fluxes and surface temperature were computed from the numerical solution method TDMA from the measured temperature histories for radial position one dimensional heat transfer inverse problem. The boiling curves were found by the computed temperature histories. 3. The rewetting point which starts to change from film boiling to nucleate boiling is not connected with the mass velocity and it were found that the temperature of rewetting point indicated about $100^{\circ}C$. 4. The heat flux of rewetting point was about $10^5Kcal/m^2h$, at that time, the heat transfer coeficient indicated about $1000Kcal/m^2h^{\circ}C$ irrelevent to mass velocity. 5. The wall superheat decreases as the pressure increases. But I found that rewetting point appeared under higher condition in the wall temperature.

  • PDF

Particle and NOM Fouling in Ultrafiltration with Softening Pretreatment (연수화 전처리를 적용한 한외여과에서 입자상 물질 및 자연유기물 막오염)

  • Kweon, Ji-Hyang;Lawler, Desmond F.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.534-541
    • /
    • 2003
  • Membrane processes are now frequently considered for application in drinking water treatment. The biggest impediment for applying membrane processes is fouling that comes from mass flux (such as particle and organic matter) to the membrane surface and its pores due to convection flow through the membrane. Natural organic matter (NOM) has been reported as the most detrimental foulant. Some research also indicated that particles were often the dominant cause of fouling. Therefore, both NOM and particle fouling need to be examined to better understand fouling in ultrafiltration. Two waters from natural sources, Lake Austin water and Missouri River water, were selected. Both waters are relatively hard waters but has significantly different particle concentrations, which will elucidate effects of particles on membrane fouling. Precipitative softening is traditionally designed to remove hardness ions in hard waters but it can also remove particles and organic matter. Therefore, the integrated water treatment with softening and ultrafiltration is proposed as a promising option for hard waters. The three levels of softening were used to represent different degrees of pretreatment to ultrafiltration in terms of organic matter (i.e., NOM fouling) and precipitates (i.e., particle fouling by further precipitation). Results showed that natural particles in Missouri River water was detrimental foulants of ultrafiltration. As the levels of softening were increased, NOM and particle removal was increased, and thus fouling was decreased. Direct images of the surface of the membranes by scanning electron microscopy allowed observation of the different properties of particles caught in fibril networks of natural organic matter.

Three-Dimensional Natural Convection from a Single Module on the Wall of a Vertical Parallel-Plate Channel (수직평행채널의 벽면에 부착된 단일모듈로부터의 3차원 자연대류 열전달)

  • Riu, K.J.;Lee, J.H.;Kim, H.W.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.29-41
    • /
    • 1999
  • Three-dimensional natural convective heat transfer in a vertical channel with a protruding single module was investigated experimentally. The particular interest was in the removal of thermal energy from the module by convective heat transfer. Hence radiative and conductive heat losses were estimated by using thermocouples and heat flux sensor respectively. The flow fields in the channel were visualized by means of a smoke-method. Also, local temperatures were measured by thermocouples inside the channel, along the vertical wall and module surface. It is found that convective heat transfer was promoted at the lower comer of the module and was decreased at the upper comer due to a recirculation zone. A general correlation of the critical channel ratios was found as a function of Rayleigh number. For the range of $8.28{\times}10^3<Ra^*_c<3.48{\times}10^6$, a useful correlation for the mean Nusselt number was proposed as a function of modified channel Rayleigh number.

  • PDF

Preparation and Performance of Low Pressure PVDF Nano-composite Hollow Fiber Membrane Using Hydrophilic Polymer (친수화 고분자 소재를 이용한 저압용 PVDF 나노복합중공사막의 제조 및 성능 연구)

  • Park, Cheol Oh;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.28 no.5
    • /
    • pp.361-367
    • /
    • 2018
  • In this study, the nanofiltration (NF) composite membranes for the low pressure use were prepared using polyvinylidene fluoride (PVDF) hollow fiber membrane as a supporter. Poly styrene sulfonic acid (PSSA) and polyethyleneimine (PEI) were coated onto the PVDF membrane by both layer-by-layer and salting-out methods. To characterize the prepared NF membranes in terms of the flux and salt rejection, 100 mg/L feed solutions of NaCl, $MgCl_2$, and $CaSO_4$ were used at the flow rate of 1 L/min and the operating pressure of 2 bar at room temperature. The NF membranes coated with 20,000 ppm PSSA (ionic strength 1.0) solution for 3 minutes and then 30,000 ppm (ionic strength 0.1) solution for 1 minute were observed the best performance. The permeability and salt rejection were 38.5 LMH, 57.1% for NaCl, 37.9 LMH and 90.2% for $MgCl_2$ and 32.4 LMH and 54.6% for $CaSO_4$, respectively.

The heat transfer characteristics of a desorber for 150 RT absorption heat pump (150 RT급 흡수식 열펌프용 고온재생기의 열전달 특성)

  • 박찬우;정종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.369-376
    • /
    • 1999
  • Experiments were carried out to study the heat transfer characteristics of a disrober for 150 RT LiBr-water absorption heat pump. An experimental apparatus was divided into four sections, a combustion chamber area, two bare-tube areas, and finally a finned-tube area to quantify the heat transfer rate of each section by measuring the generation rate of vapor. Dividing plates was installed at the upper inside part of deserter to prohibit the moving of vapor generated at heating tubes of a section to another section near. In the first bare-tube area, the generation rate of vapor was the largest among the four sections. The finned-tube area only contributed to give sensible heat increase of solution to the saturation temperature. The heat transfer area of the finned-tube area was 52.2%, which absorbed only 9.2% of the total heat from the combustion gas. On the contrary, the heat transfer area of the first bare-tube area was 16.6%, but it absorbed 52.4% of the total absorbed heat. The temperature of the solution at upper part at the finned-tube area was lower than that of the lower part, because weak solution came in upper part of the finned-tube area. But, this tendency was changed at the first and second bare-tube area due to the vigorous heat transfer and fluid flow enhanced by vapor generation through heating tubes. The overall heat transfer coefficient and heat flux were the largest at the first bare-tube area among the other sections.

  • PDF