• Title/Summary/Keyword: Flux-Flow

Search Result 1,677, Processing Time 0.028 seconds

SgrA* 22GHz KaVA(+TAK) observation and its Amplitude Calibration

  • CHO, ILJE;JUNG, TAEHYUN;ZHAO, GUANG-YAO;KINO, MOTOKI;SOHN, BONGWON
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.52.2-52.2
    • /
    • 2015
  • SgrA* located in the center of the Milky Way is of great interest to understand the physics of supermassive black hole(SMBH) and the interaction of the G2 cloud around SgrA* with the accretion flow which was expected since 2013. In order to seize this rare opportunity, KVN and VERA Array (so called, KaVA) has started an intensive monitoring program of SgrA* at 22/43 GHz where scatter broadening is reduced compared to lower frequency VLBI observations. We present the results of KaVA SgrA* observation together with Takahagi (32m) and Yamaguchi (32m) telescopes at 22 GHz on March 24, 2013. We have tested both a standard amplitude calibration methods using the Tsys and antenna gain information and a template amplitude calibration method which uses a peak of H2O maser line of nearby maser source (SgrB2), and found that the latter method is useful when an accuracy of Tsys measurement or antenna gain of a telescope is poor. In our comparison, the difference between the two methods is around 20% (~5% for the KVN and ~15% for the VERA when the elevation is above $20^{\circ}$). We also imaged SgrA* with a total flux of ~0.7 Jy at 22GHz, and fitted an elliptical Gaussian model which has a size of ~2.5mas for major axis and ~1.7mas for minor axis, respectively.

  • PDF

A Comparative Study of Two-Dimensional Numerical Models for Surface Discharge of Heated Water into Crossflow Field (가로흐름 수역으로 방출되는 2차원 표면온배수 수치모형 비교연구)

  • 이남주;최흥식;이길성
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.6 no.1
    • /
    • pp.40-50
    • /
    • 1994
  • For an accurate prediction of the temperature field induced by heated water discharged into a shallow crossflow, a two-dimensional near-field numerical model is developed. It is based on a 4-equation turbulence model in which the transport equations for mean of the temperature fluctuation squared and its dissipation rate are added to those of a 2-equation turbulence model which cannot give the information of the thermal time scale ratio. Vertical diffusion is also considered by including buoyancy production and turbulence heat flux terms. The developed model is applied to a steady flow in an open channel with simple geometry and the results are compared with existing experimental data and those of the already established 2-equation turbulence model. Numerical results of the model agree with the experimental data better than those of the 2-equation model. The present model also simulates quite adequately the physical characteristics of thermal discharge in the jet entrainment and stable regions.

  • PDF

Validations of a Numerical Model of Solute Transport in a Snowpack (눈 속에서 용질이동을 모사하기 위한 수치모델의 검증)

  • Lee, Jeonghoon
    • Economic and Environmental Geology
    • /
    • v.45 no.5
    • /
    • pp.525-533
    • /
    • 2012
  • Snowmelt from seasonal snow covers can be significant in many environments of northern and alpine areas. Water flow and chemical transport resulting from snowmelt have been studied for an understanding of contributions to watersheds or catchments. A Mobile-Immobile water Model (MIM) was developed to describe the movement of ionic tracers through a snowpack by Lee et al. (2008a) and Lee et al. (2008b). To validate the model used in the studies, mass balance calculations of the model were conducted and comparisons were made between model results and analytical solutions in this work. Mass balance was calculated based on the fact that change in total mass within a snowpack with time is equal to sum of any change in the flux of water or ionic tracers into and out of the snowpack. Calculations of both water and ionic mass show almost perfect agreement between changes of two water and solute mass fluxes. Comparisons between model results and analytical solutions including wave velocity and effective saturation show almost perfect agreement.

Design of a Wind Tunnel for Plug Seedlings Production under Artificial Light and Aerodynamic Characteristics above Plug Stand (인공광하의 공정육묘용 풍동 설계 및 공정묘 개체군상의 공기역학적 특성)

  • 김용현;고재풍수
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.429-435
    • /
    • 1996
  • A wind tunnel consisting of two air flow conditioners with polycarbonate pipes, a plant growth room, a suction fan and fan controller, and fluorescent lamps, was designed to investigate the interactions between the growth of plug seedlings under artificial light and their Physical environments. Light transmissivities in the plant growth room based on the photosynthetic photon flux density and photosynthetically active radiation was appeared to be 96.3% and 96.8%, respectively. Measurement showed a uniformity in the vertical profiles of air current speed at the middle and rear regions of plug trays in wind tunnel. This result indicated that the development of a wind tunnel based on the design criteria of the American Society of Mechanical Engineers was adequate. Air current speed inside the plug stand was significantly decreased due to the resistance by the leaves of plug seedlings and boundary layer developed over and below the plug stand. Driving force to facilitate the diffusion of gas inside the plug stand might be regarded as extremely low. Aerodynamic characteristics above the plug stand under artificial light were investigated. As the air current speed increased, zero plane displacement decreased but roughness length and frictional velocity increased. Zero plane displacement linearly increased with the average height of plug seedlings. The wind tunnel developed in this study would be useful to investigate the effects of air current speed on the microclimate over and inside the plug stand and to collect basic data for a large-scale plug production under artificial light in a semi-closed ecosystem.

  • PDF

Introduction of KIER Pyrolysis Process and 3,000 ton/yr Demonstration Plant (KIER의 열분해유화 공정 기술과 실증플랜트 소개)

  • Shin, Dae-Hyun;Jeon, Sang-Gu;Kim, Kwang-Ho;Lee, Kyong-Hwan;Roh, Nam-Sun;Lee, Ki-Bong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.479-482
    • /
    • 2008
  • Since late of 2000, KIER has developed a novel pyrolysis process for production of fuel oils from polymer wastes. It could have been possible due to large-scale funding of the Resource Recycling R&D Center. The target was to develop an uncatalyzed, continuous and automatic process producing oils that can be used as a fuel for small-scale industrial boilers. The process development has proceeded in three stages bench-scale unit, pilot plant and demonstration plant. As a result, the demonstration plant having capacity of 3,000 tons/year has been constructed and is currently under test operation for optimization of operation conditions. The process consisted of four parts ; feeding system, cracking reactor, refining system and others. Raw materials were pretreated via shredding and classifying to remove minerals, water, etc. There were 3 kind of products, oils(80%), gas(15%), carbonic residue(5%). The main products i.e. oils were gasoline and diesel. The calorific value of gas has been found to be about 18,000kcal/$m^3$ which is similar to petroleum gas and shows that it could be used as a process fuel. Key technologies adopted in the process are 1) Recirculation of feed for rapid melting and enhancement of fluidity for automatic control of system, 2) Tubular reactor specially-designed for heavy heat flux and prevention of coking, 3)Recirculation of heavy fraction for prevention of wax formation, and 4) continuous removal & re-reaction of sludge for high yield of main product (oil) and minimization of residue. The advantages of the process are full automation, continuous operation, no requirement of catalyst, minimization of coking and sludge problems, maximizing the product(fuel oil) yield and purity, low initial investment and operation costs and environment- friendly process. In this presentation, background of pyrolysis technology development, the details of KIER pyrolysis process flow, key technologies and the performances of the process will be discussed in detail.

  • PDF

Effect of Mixed Treatment of Urea Fertilizer and Zeolite on Nitrous Oxide and Ammonia Emission in Upland Soil

  • Park, Jun-Hong;Park, Sang-Jo;Seo, Young-Jin;Kwon, Oh-Heun;Choi, Seong-Yong;Park, So-Deuk;Kim, Jang-Eok
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.5
    • /
    • pp.368-373
    • /
    • 2014
  • Ammonia loss from urea significantly hinders efficient use of urea in agriculture. The level of nitrous oxide ($N_2O$) a long-lived greenhouse gas in atmosphere has increased mainly due to anthropogenic source, especially application of nitrogen fertilizers. There are reports in the literature showing that the addition of zeolite to N sources can improve the nitrogen use efficiency. This study was conducted to evaluate nitrous oxide ($N_2O$) and ammonia ($NH_3$) emission by mixed treatment of urea and zeolite in upland crop field. Urea fertilizer and zeolite were applied at different rates to study their effect on $N_2O$ emission during red pepper cultivation in upland soils. The $N_2O$ gas was collected by static closed chamber method and measured by gas chromatography. Ammonia concentration was analyzed by closed-dynamic air flow system method. The total $N_2O$ flux increased in proportion to the level of N application. Emission of $N_2O$ from the field increased from the plots applied with urea-zeolite mixture compared to urea alone. But urea-zeolite mixture treatment reduced about 30% of $NH_3$-N volatilization amounts. These results showed that the application of urea and zeolite mixture had a positive influence on reduction of $NH_3$ volatilization, but led to the increase in $N_2O$ emission in upland soils.

A Convergent Investigation on the thermal and stress analyses of CPU Cooler (CPU 쿨러의 열 및 응력 해석에 관한 융합 연구)

  • Choi, Kye-Kwang;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.8
    • /
    • pp.153-158
    • /
    • 2020
  • In this study, the thermal and stress analyses were performed by applying a temperature condition of 100℃ at CPU cooler model. The value of heat flux value is shown to be the most at the lower rod area. The upper part becomes, the smaller the heat flow rate. The highest temperature is shown at the bottom of the CPU cooler model. Overall, the upper part becomes, the smaller the temperature becomes. Based on the temperature analysis, the thermal deformation caused by expansion, the deformation becomes smaller as the upper part of the overlapping plates. The great deformation happens at the bent area of the small rod as the lower part of model and the least deformation is shown at the lowest floor of model. In addition, the maximum thermal stress of 570.63 MPa happens at the floor below model. The stress is shown to decrease as the upper part of the overlapping plates becomes. But the stress is shown to increase somewhat at the middle part of model. By applying the study result on the thermal and stress analyses of CPU cooler, this study is seen to be suitable for the aesthetic convergence.

Heat transfer characteristics of the heat pipe using simplified heat transfer model (단순 열전달 모델을 이용한 히트파이프의 열전달 성능특성에 관한 연구)

  • Seo, Jae-Hyeong;Bang, Yu-Ma;Seo, Lee-Soo;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • The objective of this study was to examine numerically the heat transfer and flow characteristics of the heat pipe with a wick using the simplified heat transfer model to enhance the cooling effects of high heat flux devices and minimizing the energy consumption for electric vehicles. The heat pipe with a wick was analyzed using commercial software with COMSOL and water was used as the working fluid. The velocity and temperature characteristics of the heat pipe were simulated numerically along the heat pipe and the local and average Nusselt numbers were calculated. As a result, the driving force occurred because of the temperature difference between the hot side and the cold side. The heat transfer of the heat pipe occurred from the hot side to the cold side and increased toward the center position. In addition, the average Nusselt numbers were 1.88 for the hot side and 0.1 for the cold side, and the maximum Nusselt number was 4.47 for the hot side and 0.7 for the cold side.

The Effect of Thermal Buoyancy on Air Flow and Temperature Distribution in a Slot-Ventilated Livestock Building (환기중(換氣中)인 축사(畜舍)의 열부력(熱浮力)이 공기유동 및 온도분포에 미치는 영향)

  • Choi, H.L.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.2
    • /
    • pp.144-157
    • /
    • 1993
  • 환기중인 실험축사내에서 가축의 현열과 환기공기의 온도차에 의한 열부력(熱浮力)(thermal buoyancy)이 공기유동 및 온도분포에 미치는 영향을 구명(究明)하기 위하여 TEACH 컴퓨터프로그램($k-{\varepsilon}$ 난류모형 및 SIMPLE계열 Algorithm)을 Curvilinear Coordinates에 맞게 변형하였다. 계산한 축사내 공기유통 및 온도분포의 유의성(有意性) 검증은 Boon(1978)의 실험결과를 이용하였다. 열부력의 크기에 따른 유동의 변화를 관찰하기 위하여 유입공기의 온도를 $17^{\circ}C$$10^{\circ}C$ 두 수준으로 입력하였으며, 가축의 현열플릭스(flux)는 실내온도에 따라 변화하므로 유압공기의 온도가 $17^{\circ}C$일 때는 130W/$m^2$, $10^{\circ}C$일 때는 170W/$m^2$을 경계조건으로 입력하였다. 예측한 공기유동의 형태는 실험값(Boon, 1978)과 비교하여 대체로 만족할만한 결과를 얻었다. 그러나 유입공기의 온도가 $10^{\circ}C$인 경우, 예측 공기유동은 실험 유동형태와 차이가 있었다. 즉, 실험에서는 수평슬롯으로 유입된 공기가 바로 아래로 굴절되어 유동(流動)하였으나, 계산의 결과는 일정 거리로 수평방향으로 유동하다가 아래로 굴절하였다. 이런 유동의 차이는 경험적으로 열부력(熱浮力)에 민감하게 반응하지 않는 k-${\varepsilon}$ 난류(亂流)모형의 적용이 원인이 되거나 실험의 부적절한 수행이 원인이 될 수도 있다. 이 유동(流動)의 Reynolds 수(數) (Re)는 약 3,300, 수정Ar수(修正Ar數)(Corrected Archimedes Number : $Ar_c$)64로써, $Ar_c$ <30 이거나 $Ar_c$ >75이면 유입공기의 제트는 수평유동한다는 Randall & Battams(1979)의 연구결과와는 일치하였다. 그러나 공기제트의 굴절은 유동의 특성이 같다하더라도 유체의 성질, 축사의 기하학적 형태에 따라서 매우 민감하게 반응하므로 실제 실험을 통한 재검정과정을 거쳐야 할 것으로 판단된다. Fig. 9와 Fig. 10의 기하학적 형태의 지점별 예측온도와 측정온도(Boon, 1978)와의 편차는 대부분의 지점에서는 $1^{\circ}C$ 미만으로 상당히 정확하였으며, 최대의 온도차는 Fig. 10의 지점 13에서 $1.7^{\circ}C$이었다.

  • PDF

Systems Engineering Approach to the Heat Transfer Analysis of PLUS 7 Fuel Rod Using ANSYS FEM Code

  • Park, Sang-Jun;Mutembei, Mutegi Peter;Namgung, Ihn
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.13 no.1
    • /
    • pp.33-39
    • /
    • 2017
  • This paper describes the system engineering approach for the heat transfer analysis of plus7 fuel rod for APR1400 using, a commercial software, ANSYS. The fuel rod is composed of fuel pellets, fill gas, end caps, plenum spring and cladding. The heat is transferred from the pellet outward by conduction through the pellet, fill gas and cladding and further by convection from the cladding surface to the coolant in the flow channel. The goal of this paper is to demonstrate the temperature and heat flux change from the fuel centerline to the cladding surface when having maximum fuel centerline temperature at 100% power. This phenomenon is modelled using the ANSYS FEM code and analyzed for steady state temperature distribution across the fuel pellet and clad and the results were compared to the standard values given in APR1400 SSAR. Specifically the applicability of commercial software in the evaluation of nuclear fuel temperature distribution has been accounted. It is note that special codes have been used for fuel rod mechanical analysis which calculates interrelated effects of temperature, pressure, cladding elastic and plastic behavior, fission gas release, and fuel densification and swelling under the time-varying irradiation conditions. To satisfactorily meet this objective we apply system engineering methodologies to formulate the process and allow for verification and validation of the results acquired. The close proximity of the results obtained validated the accuracy of the FEM analysis of the 2D axisymmetric model and 3D model. This result demonstrated the validity of commercial software instead of proprietary in-house code that is more costly to develop and maintain.