Ammonia Flux from Cow Manure in Relation to the Environmental Factors in Livestock Facilities (축산분뇨에서 발생하는 암모니아 플럭스에 대한 환경인자의 영향에 관한 연구)

  • Sa, Jae-Hwan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.4
    • /
    • pp.432-442
    • /
    • 2010
  • Ammonia is a very important constituent of the atmospheric environment because it is the most dominant gaseous alkaline species present in the atmosphere. Ammonia is known to affect ecosystems at relatively low concentration. Ammonia flux from livestock facilities can be regulated by a number of environmental factors (pH, ammonium ion, temperature, wind speed, etc). The increases in wind speed above manure from 0.0 m/s to 1.0 7m/s resulted in 2.5 times increases in ammonia flux. Wind speed and ammonia flux showed 0.982. A linear relationship with a correlation coefficient (r=0.982). When manure temperature increased from $3^{\circ}C$ to $36^{\circ}C$, the manure pH decreased approximately 0.30 to 0.46. As wind speed above the manure increased from 0.0 m/s to 1.07 m/s, ammonia flux increased approximately 2.5 times. The increasing manure temperature from $3^{\circ}C$ to $10^{\circ}C$, raised ammonia flux from 2.0 to 3.6 times (2.6 times in average similarly). The increases of manure temperature from $3^{\circ}C$ to $25^{\circ}C$ increased ammonia flux from 5.7 to 12.9 times (8.5 times in average). In this study, the correlation coefficient between ammonia flux and manure temperature was found from 0.972 to 0.989. Results of our research showed that ammonium ion concentration, pH of manure and wind speed were important factors in controlling the ammonia flux from manure livestock facilities.

Analysis of Fault Current limiting Characteristics According to Fault Type in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current limiting (사고종류에 따른 삼상 일체화된 자속구속형 SFCL의 사고전류제한특성 분석)

  • Park, Chung-Ryul;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.54-56
    • /
    • 2005
  • In this paper, we investigated the quench characteristics of HTSC elements in the integrated three-phase flux-lock type SFCL according to fault types such as the single-line-to-ground fault, the double-line-to-ground fault, the line-to-line fault and the three-line-to-ground fault. The integrated three-phase flux-lock type SFCL was the upgrade version of the single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase. It was observed that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF

A study on the Measurement of Residual Flux for Transformer (변압기 잔류자속 측정에 관한 연구)

  • Kim, Young-Hak
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.5
    • /
    • pp.133-138
    • /
    • 2022
  • In previous studies to obtain the residual magnetic flux of the transformer using the leakage magnetic flux, a transfer function was used. The transfer function was consisted with the leakage magnetic flux measured outside the transformer and the residual magnetic flux measured at the moment passing through the two ± residual points. In this study, a method of calculating the ratio of the maximum operating leakage flux to the residual leakage flux was proposed The advantage of this method is to avoid the uncertainty of the transfer function due to current noise. Then, the noise of the sensor was measured to investigate the effect of the drift of the noise on the measurement results. Comparing the residual leakage magnetic flux density with 80nT of the drift noise, 66 times or more at a distance of 10 mm and 5 times or more at a distance of 100 mm were obtained. 100mm was the maximum measurement distance to obtain the residual magnetic flux.

A Study on Wettability and Defects Behavior of Flow-soldered Joint using Low Residue Flux (저잔사 플럭스를 사용한 플로우 솔더링부의 젖음성 및 결함거동에 관한 연구)

  • 최명기;이창열;정재필;서창제;신영의
    • Journal of Welding and Joining
    • /
    • v.16 no.6
    • /
    • pp.77-85
    • /
    • 1998
  • Effects of non-cleaning and cleaning fluxes on the wetting properties and defects at flow soldered joints were investigated. Non-cleaning flux (R-type of 3.3% solid content) and cleaning flux (RMA-type of 15% solid content) were used. Wetting test was accomplished by wetting balance method with changing surface state of wetting specimen, CU. Sn-37%Pb solder was used for wetting test and flow soldering. As experimental results, the wetting time for vertical force from the surface tension being zero was mainly affected by surface state of the wetting specimen. Non-cleaning flux had a good wettability compared with cleaning flux. In case of non-cleaning flux, conveyor speed had a great affection to defects of bridge, icicle, and poor solder.

  • PDF

SATELLITE-DERIVED SENSIBLE HEAT FLUX OVER THE OCEAN

  • .Kubota Masahisa;Ohnishi Keisuke;Iwasaki Shinsuke;Tomita Hiroyuki
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.30-33
    • /
    • 2005
  • Though sensible heat flux is one of heat flux components, it is generally considered that the importance is low compared with other components because of the small value. Actually sensible heat flux over the tropical ocean is extremely small, less than $100\;W/m^2$ .. However, it should be noted that sensible heat flux in boreal winter over the western boundary current regions is considerably large, about $100\;W/m^2$, and not neglected. In this study we carry out intercomparison of various global sensible heat flux data including not only satellite-derived data but also reanalysis data in order to clarify the characteristics of those data.

  • PDF

Surface Heat Budget of the Northern Sea of Cheju Island for June-August 1993 and 1994 (제주도 북부해역의 표면 열수지 해석 -1993년과 1994년 하계의 경우-)

  • 김해동;양성기
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.197-206
    • /
    • 1995
  • Surface heat balance of the northern sea of Cheju Island for summer in 1993 and 1994 is analyzed using the observation data obtained by Marine Research Institute, Cheju National University. Each flux elements at the sea surface is derived from the marine meteorological reports with application of an aerodynamical bulk method for the turbulent heat fluxes, and empirical formulae for the long-wave radiation heat fluxes. The flux divergence of oceanic heat transport and the rate of heat storage in the ocean are estimated as residual. The features of the surface heat balance are mainly decided by the solar radiation flux and the latent heat flux for 199B. But the Bowen Ratios were large for 1993. This means that the sensible heat fluxes were nearly equal to the latent heat fluxes for 1993. In this period, mean flux divergence of oceanic heat transport is about 130 W/$m^2$.

  • PDF

Maximum Torque Operating Strategy based on Stator Flux Analysis for Direct Torque and Flux Control of a SPMSM (고정자 자속의 해석을 통한 직접 토크 제어 SPMSM의 최대 토크 운전)

  • Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.463-469
    • /
    • 2014
  • This paper proposes a maximum torque operation strategy for the direct torque control of a surface-mounted permanent-magnet synchronous motor (SPMSM). The proposed method analyzes the available operation region of the stator flux of the SPMSM under voltage and current constraints. Based on this analysis, the optimal stator flux trajectory that yields the maximum torque is obtained across the entire operation region, including constant torque and constant power regions. The proposed strategy is also applicable in the flux-weakening region II operation of the SPMSM, which has no speed limit. The validity of the proposed method is verified through experiments conducted on an 800 W SPMSM drive system.

A Study on Back EMF of BLDC Motor Using Numetical Analysis Method (수치해석 방법을적용한 BLDC 전동기의 역기전력 연구)

  • Kim, Hyun-Cheol
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.36-41
    • /
    • 2008
  • This report describes the analytical solution of back EMF for BLDC motor using numerical analysis of air gap flux density. The analysis of air gap flux density is the key to expect the performance of back EMF for the design of brushless motor. The numerical analysis and FEM analysis are performed to vary attachment of stator side or rotor side, radial flux magnetization or parallel flux magnetization, magnet arc angle in the condition of constant air gap. This results have more reliable data comparing with test result of the back EMF for 7 phase BLDC motor.

Effect of flux on low temperature sintering for PNN-PT-PZ piezoelectric ceramics (PNN-PT-PZ계 압전세라믹스의 저온소결에 미치는 flux의 영향)

  • 이기태;남효덕
    • Electrical & Electronic Materials
    • /
    • v.6 no.6
    • /
    • pp.537-544
    • /
    • 1993
  • 기본조성이 0.5[Pb(Ni$_{1}$3/Nb$_{2}$3/)O$_{3}$]-0.5[0.65PbTiO$_{3}$ -0.35PbZrO$_{3}$] (PNN-PT-PZ)인 압전세라믹스를 NaCl-KCI를 사용한 flux의 양 및 소결온도에 따른 생성반응과 소결특성, 유전 및 압전특성을 조사하였다. 이때 1몰의 산화물에 대한 flux의 양은 0.1, 2 및 5mole로 하였으며 소결온도는 1000-1200.deg.C로 하였다. 본 연구의 flux법은 고상반응법에 비해 낮은 하소온도에서 pyrochlore상을 현저히 줄일수 있었으며 고상반응법보다 낮은 온도에서 치밀화가 이루어질뿐 아니라 유전 및 압전특성을 개선할 수 있었으며 소결온도도 낮출 수 있었다. Flux의 양이 증가할수록 결정의 입성장이 빨랐으며 유전 및 압전특성이 가장 좋은 flux의 첨가량의 조건은 1mole이었다.

  • PDF

COMPARISON OF FLUX AND RESIDENT CONCENTRATION BREAKTHROUGH CURVES (BTCs) IN STRUCTURED SOIL COLUMNS

  • Kim, Dong-Ju
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1997.05a
    • /
    • pp.25-29
    • /
    • 1997
  • In many solute transport studies, either flux or resident concentration has been used. Choice of the concentration mode was dependent on the monitoring device in solute displacement experiments. It would be questionable, however. to accept the equivalency in the solute transport parameters between flux and resident concentrations in structured soils exhibiting preferential movement of solute. In this study, we investigate how they differ in the monitored breakthrough curves (BTCs) and transport parameters for a given boundary and flow condition by performing solute displacement experiments on a number of undisturbed soil columns. Both flux and resident concentrations have been simultaneously obtained by monitoring the effluent and resistance of the Horizontally-positioned TDR probes. The study reveals that soil columns having relatively high flux densities exhibited great differences in the degree of peak concentration and travel time of peak between flux and resident concentrations. The peak concentration in flux mode was several times higher than that in resident one. This was mainly due to the bypassing of solute through soil macropores.

  • PDF