C-arm의 Tube 위치에 따른 거리 및 방향별 피폭선량 비교 (A Comparision of the Radiation dose by Distance and the Direction according to a Tube Position of the C-arm Unit)

  • 김진수;우봉철;김성진;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.21-26
    • /
    • 2009
  • In operation room, the use of the C-arm unit is increasing. So, the radiation dose of the person who work in operation room was even more increased than before. Thus, this study is shown the measurement of expose dose and the way for decrease of the radiation dose by using the C-arm unit. The experiment was performed with the C-arm unit and used a phantom which is similar to tissue of the human body and fluoro-glass dosimeter for dose measurement. The expose dose were measured by the tube position(over tube, under tube) of the C-arm unit, distance(50, 100$\sim$200cm), direction(I, II, III, IV), runtime(1min, 3min), wearing of the apron. The radiation dose was decreased twice and three times at under tube rather than over tube. The I direction was measured 20$\sim$30% more than the others. The biggest expose dose is 50cm from center on distance. The expose dose is decreased to far from center. In case of Wearing of the apron, the radiation dose was decreased 60$\sim$90% by the distance. But there weren't change of the radiation dose by C-arm tube position. In present, by increasing the usage of the C-arm unit, the radiation dose is inevitable. So, this study recommends us to use the under tube of the C-arm unit. Also, Wearing of the apron is required for minimum of the radiation exposure.

  • PDF

DAP(Dose Area Product)를 이용한 TLD와 PLD의 선량 측정 비교 (Comparison on the Dosimetry of TLD and PLD by Dose Area Product)

  • 최재호;강구준;장서구
    • 한국콘텐츠학회논문지
    • /
    • 제12권3호
    • /
    • pp.244-250
    • /
    • 2012
  • 본 연구는 현재 법령 개인선량계인 PLD와 TLD의 선량 분석을 통해 성능 차이를 알아보고자 하였다. 자동판독장치를 이용해 PLD와 TLD의 적산선량을 판독 후 선량 교정 과정을 거친 두 소자의 값은 70kVp, 200mA, 0.012sec와 42kVp, 100mA, 0.012sec의 각각의 촬영조건에서 TLD는 PLD 측정 시와 통계적 차이를 나타냈다(각각 p<0.001, p<0.001). DAP와 두 소자의 측정값 차이는 70kVp, 200mA, 0.012sec 촬영조건에서 TLD는 DAP 평균값보다 $44.2mGy{\cdot}cm^2$이 낮은 값이 나타났고, PLD는 DAP 평균값에 $15.5mGy{\cdot}cm^2$이 낮은 $246.8mGy{\cdot}cm^2$으로 나타났다. 42kVp, 100mA, 0.012sec 촬영조건에서는 TLD는 DAP 평균 값의 $17.9mGy{\cdot}cm^2$이 낮은 값을 보였으며, PLD는 DAP 평균값에 $7.6mGy{\cdot}cm^2$이 낮은 $82.6mGy{\cdot}cm^2$으로 나타나 PLD가 DAP에 더 근접한 값을 보였다. 또한 PLD에 비해 TLD는 10개의 각 소자마다 측정된 선량 값에서 소자 상호간의 편차가 크게 나타났고, 1개의 소자를 반복 측정한 재현성 실험에서 PLD는 ${\pm}1%$ 이내로 TLD ${\pm}2%$ 보다 낮게 나타났다. 따라서 PLD가 TLD에 비해 선량 측정 능력면에서 더 우수한 결과가 나타났고, 진단용 방사선영역에서 방사선작업종사자의 개인피폭 관리에 PLD가 더욱 적합하고 유리함을 확인할 수 있었다.