• Title/Summary/Keyword: Fluorescence of droplet

Search Result 21, Processing Time 0.02 seconds

Impinging Atomization of Intermittent Gasoline Sprays (간헐 가솔린 분무의 충돌에 의한 미립화 촉진)

  • 원영호;임치락
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.174-181
    • /
    • 1998
  • Experimental and analytical studies are presented to characterize the break-up mechanism and atomization processes of the intermittent- impinging-type nozzle. Gasoline jets passing through the circular nozzle with the outlet diameter of 0.4mm and the injection duration of 10ms are impinged on each other. The impingement of fuel jets forms a thin liquid sheet, and the break-up of the liquid sheet produces liquid ligaments and droplets subsequently. The shape of liquid sheets was visualized at various impinging velocities and angles using the planer laser induced fluorescence (PLIF) technique. Based on the Kelvin-Helmholtz wave instability theory, the break-up length of liquid sheets and the droplet diameter are obtained by the theoretical analysis of the sheet disintegration. The mean diameter of droplet is also estimated analytically using the liquid sheet thickness at the edge and the wavelength of the fastest growing wave. The present results indicate that the theoretical results are favorably agreed with the experimental results. The size of droplets decreases after the impingement as the impinging angle or the injection pressure increase. The increment of the injection pressure is more effective than the increment of the impinging angle to reduce the size of droplets.

  • PDF

An Experimental Study on Droplet Size Characteristics of Liquid Jets in Subsonic Crossflow (수직분사제트에서 액적크기특성에 대한 실험적 연구)

  • Kim, Min-Ki;Song, Jin-Kwan;Kim, Jin-Ki;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.59-63
    • /
    • 2006
  • A direct photograph measurement technique was used to determine the spatial distribution of the spray droplet diameter in subsonic crossflow and it also obtain that SMD distribution by using PLLIF technique. The injector internal flow was classified as three modes such as a normal, cavitation, and hydraulic flip. The objectives of this research are getting a droplet distribution and drop size measurement of normal flow and compare with the other flow effects. Although the study showed visually that drop size were spatially dependent of Air-stream velocity, fuel injection velocity, and normalized distance from the injector exit length.(x/d, y/d) There are also difference characteristics between cavitation, hydraulic flip and the normal flow.

  • PDF

Measurement of Insoluble Mineral Particles in a Saturated Atmosphere

  • Ma, Chang-Jin;Choi, Sung-Boo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.E1
    • /
    • pp.44-53
    • /
    • 2008
  • This study was undertaken to measure the properties of individual mineral particles in an artificially saturated atmosphere at a vertical extinct mine with 430 m height. By synchrotron radiation X-ray fluorescence (SR-XRF) microprobe analysis, it was possible to determine the elemental composition of residual insoluble particles on individual cloud droplet replicas formed on the Collodion film. The XRF visualized elemental maps enabled us not only to presume the chemical mixing state of particles retained in cloud droplet, but also to estimate their source. Details about the individual mineral particles captured by artificial cloud droplets should be helpful to understand about the removal characteristics of dust particles such as interaction with clouds. Nearly all individual particles captured in cloud droplets are strongly enriched in Fe. Mass of Fe is ranged between 41 fg and 360 fg with average 112 fg. There is a good agreement between single particle analysis by SR-XRF and bulk particle analysis by PIXE.

Spray Charaeteristics and Exhaust Emission Tests far a Diesel Engine Using Emulsified Fuels (에멀젼 연료를 이용한 디젤엔진의 분무 및 배기특성 연구)

  • 서희준;오승묵;허환일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.60-68
    • /
    • 2002
  • Experiments have been conducted to investigate the effects of emulsified fuels on the spray characteristics and exhaust emissions in a diesel engine. Four different fuels were examined : diesel, emulsified fuels with water contents which were varied with 13, 15, and l7wt%. Characteristics of fuel spray were measured by an optical method, PLLIF(planar liquid laser induced fluorescence). Compared to diesel fuel, emulsified fuels which had relatively high kinematic viscosity showed smaller spray angle and longer spray tip penetration. The qualitative droplet distributions of emulsified fuels showed worse atomization process than that of diesel fuel. As the water contents were increased, PM and NOx could be reduced simultaneously. It was specially noted that the emulsified fuel with l7wt% water content was found to be the best in reducing rates, NOx 30% and PM 40%.

Spray Structures and Vaporizing Characteristics of a GDI Fuel Spray

  • Park, Dong-Seok;Park, Gyung-Min;Kim, Duck-Jool
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.7
    • /
    • pp.999-1008
    • /
    • 2002
  • The spray structures and distribution characteristics of liquid and vapor phases in non-evaporating and evaporating Gasoline Direct Injection (GDI) fuel sprays were investigated using Laser Induced Exciplex Fluorescence (LIEF) technique. Dopants were 2% fluorobenzene and 9% DEMA (diethyl-methyl-amine) in 89% solution of hexane by volume. In order to study internal structure of the spray, droplet size and velocity under non-evaporating condition were measured by Phase Doppler Anemometry (PDA). Liquid and vapor phases were visualized at different moments after the start of injection. Experimental results showed that the spray could be divided into two regions by the fluorescence intensity of liquid phase: cone and mixing regions. Moreover, vortex flow of vapor phase was found in the mixing region. About 5㎛ diameter droplets were mostly distributed in the vortex flow region. Higher concentration of vapor phase due to vaporization of these droplets was distributed in this region. Particularly, higher concentration of vapor phase and lower one were balanced within the measurement area at 2ms after the start of injection.

Vaporizing Characteristics of Spray from Two Different GDI Injectors (분무각이 다른 GDI인젝터에 대한 증발특성)

  • Choe, Dong-Seok;Kim, Deok-Jul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.688-696
    • /
    • 2001
  • Vaporizing characteristics of two GDI injectors with different spray angles were investigated using exciplex fluorescence method. Injector I has narrower spray angle, while injector II has wider one. The exciplex system of fluorobenzene and DEMA in a non-fluorescing base fuel of hexane was employed. In quantifying concentration of fuel vapor, quenching of concentration and temperature was corrected. Droplet size and velocity were also measured by PDPA under non-vaporizing condition. From obtaining the images of liquid and vapor phases, vaporizing GDI sprays could be divided as two regions: cone and mixing regions. For injector I, vortex region was not developed. High concentration of fuel vapor due to vaporization of many fine droplets was distributed near the spray axis. For injector II, droplets with the diameter of about 10 $\mu$m were distributed in the vortex region. The vortex region had high concentration of fuel vapor due to vaporization of these droplets. Particularly, higher and lower concentrations of fuel vapor were balanced at 2ms after the start of injection for injector II.

Preparation of Fluorescence Particles by Spray Pyrolysis (분무열분해법에의한 형광체 입자의 제조)

  • Kang, Yun-Chan;Jung, Kyeong-Youl;Park, Seung-Bin
    • Korean Chemical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.235-242
    • /
    • 2006
  • Spray pyrosysis is a process to prepare particles and films by evaporating and decomposing droplets of precursor solutions in the order of 1-10 micrometer in diameter. Key elements of the spray pyrolysis process include precursor, solvent, droplet generator, and reactor. Various combination of these 4 elements produces wide range of particles and films. In general. the current status of the spray pyrolysis technology is not quite promising for commercial success. However, this process will be feasible to produce multicomponent functional materials of controlled morphology. In this paper, current status of the spray pyrolysis technology is introduced with the emphasis of production of fluorescence particles.

Experimental and Numerical Study on Behavior of Impinging Spray according to Ambient Temperature (분위기 온도에 따른 충돌 분무의 거동에 대한 실험 및 수치적 연구)

  • Shim, Young-Sam;Choi, Gyung-Min;Kim, Duck-Jool
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.124-131
    • /
    • 2007
  • The numerical study on behavior of impinging spray from high-pressure swirl injector under various ambient temperatures was performed by using spray vaporization model and spray-wall impingement model implemented in modified KIVA code, and these spray models were estimated by comparison with experimental results. To compute the spray-wall impingement process, the Gosman model, which is based on the droplet behavior after impingement determined by experimental correlations, was used. The modified Abramzon and Sirignano model, that includes the effects of variable thermodynamic properties and non-unitary Lewis number in the gas film, was adapted for spray vaporization process. The exciplex fluorescence measurements were also conducted for comparison. The experimental and numerical analysis were carried out at the ambient pressures of 0.1 MPa and at the ambient temperature of 293 K and 473 K, and the spray characteristics, such as spray-wall impingement process, gas velocity field, SMD and vapor concentration, were acquired. It was found that the impinging spray develops active and SMD is small at vaporization conditions.

A Proposal for Diesel Spray Model Using a TAB Breakup Model and Discrete Vortex Method

  • Yeom, Jeong-Kuk;Lee, Myung-Jun;Chung, Sung-Sik;Ha, Jong-Yul;Jiro Senda;Hajime Fujimoto
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.532-548
    • /
    • 2002
  • A hybrid model consisting of a modified TAB (Taylor Analogy Breakup) model and DVM (Discrete Vortex Method) is proposed for numerical analysis of the evaporating spray phenomena in diesel engines. The simulation process of the hybrid model is divided into three steps. First, the droplet breakup of injected fuel is analyzed by using the modified TAB model. Second, spray evaporation is calculated based on the theory of Siebers'liquid length. The liquid length analysis of injected fuel is used to integrate the modified TAB model and DVM. Lastly, both ambient gas flow and inner vortex flow of injected fuel are analyzed by using DVM. An experiment with an evaporative free spray at the early stage of its injection was conducted under in-cylinder like conditions to examine an accuracy of the present hybrid model. The calculated results of the gas jet flow by DVM agree well with the experimental results. The calculated and experimental results all confirm that the ambient gas flow dominates the downstream diesel spray flow.

Numerical Study on Wall Impingement Process of GDI Spray According to Wall Cavity Angle (벽면 캐비티 각에 따른 GDI 분무의 벽 충돌 과정에 대한 수치적 연구)

  • Shim, Young-Sam;Kim, Duck-Jool;Choi, Gyung-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.12
    • /
    • pp.971-978
    • /
    • 2007
  • A spray-wall impingement process of a hollow-cone fuel spray from the high-pressure swirl injector in the Gasoline Direct Injection (GDI) engine were experimented and calculated at various wall geometries. The Linearized Instability Sheet Atomization (LISA) & the Aerodynamically Progressed Taylor Analogy Breakup (APTAB) model and the Gosman model were applied to model the breakup and the wall impingement process of the hollow-cone fuel spray. The numerical modelings were implemented in the modified KIVA code. The calculation results of spray characteristics, such as a spray development process and a radial distance after wall impingement, compared with the experimental results by the Laser Induced Exciplex Fluorescence (LIEF) technique. The droplet size distribution and the ambient gas velocity field, which are generally difficult to obtain by the experimental methods, were also calculated and discussed. It was found that the radial distance after wall impingement and Sauter Mean Diameter (SMD) decreased with increasing a cavity angle.