• Title/Summary/Keyword: Fluorescence immunoassay

Search Result 42, Processing Time 0.017 seconds

Bioactive characteristics of an implant surface coated with a pH buffering agent: an in vitro study

  • Pae, Hyung-Chul;Kim, Su-Kyoung;Park, Jin-Young;Song, Young Woo;Cha, Jae-Kook;Paik, Jeong-Won;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.6
    • /
    • pp.366-381
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the effectiveness of conventional sandblasted, large-grit, acid-etched (SLA) surface coated with a pH buffering solution based on surface wettability, blood protein adhesion, osteoblast affinity, and platelet adhesion and activation. Methods: Titanium discs and implants with conventional SLA surface (SA), SLA surface in an aqueous calcium chloride solution (CA), and SLA surface with a pH buffering agent (SOI) were prepared. The wetting velocity was measured by the number of threads wetted by blood over an interval of time. Serum albumin adsorption was tested using the bicinchoninic acid assay and by measuring fluorescence intensity. Osteoblast activity assays (osteoblast adhesion, proliferation, differentiation, mineralization, and migration) were also performed, and platelet adhesion and activation assays were conducted. Results: In both the wetting velocity test and the serum albumin adsorption assay, the SOI surface displayed a significantly higher wetting velocity than the SA surface (P=0.000 and P=0.000, respectively). In the osteoblast adhesion, proliferation, differentiation, and mineralization tests, the mean values for SOI were all higher than those for SA and CA. On the osteoblast migration, platelet adhesion, and activation tests, SOI also showed significantly higher values than SA (P=0.040, P=0.000, and P=0.000, respectively). Conclusions: SOI exhibited higher hydrophilicity and affinity for proteins, cells, and platelets than SA. Within the limits of this study, it may be concluded that coating an implant with a pH buffering agent can induce the attachment of platelets, proteins, and cells to the implant surface. Further studies should be conducted to directly compare SOI with other conventional surfaces with regard to its safety and effectiveness in clinical settings.

Quantitative Analysis of Methotrexate using Hitach-7600 P-module (Hitach-7600 P-module을 이용한 Methotrexate 정량분석 평가)

  • Kim, Min-Eui;Cha, Kyong-Ho;Kim, Seung-Hee;Kim, Nam-Joo;Chae, Hyo-Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.4
    • /
    • pp.167-172
    • /
    • 2009
  • Methotrexate (MTX) in one of the antineoplastic drug and it is known to effective to management of acute lymphoblastic leukemia in children, management of choriocarcinoma and related trophoblastic tumors in women, management of carcinomas of the breast, tongue, pharynx, and tests, maintenance of remission in leukemia and treatment of serve, debilitating psoriasis. Intermediate to high-dose methotrexate administration followed by leucovorin rescue is effective in treatment of carcinoma of the lung and osteogenic sarcoma. Intrathecal administration is effective in treating meningeal leukemia or lymphoma. There are FPIA (Fluorescence polarization immunoassay) and EMIT (Enzyme multiplied immunotechique) methods that measure for MTX. We evaluated the FPIA and EMIT methods. MTX were measured by Hitachi-7600 P-module using EMIT and FPIA using TDX in the sera 60 patients. The performance characteristics evaluated were, light influence, linearity, comparison with FPIA. Also, precision evaluated were three level controls through put following CLSI evaluation protocols (EP10-A). When the MTX value of $4.16{\pm}5.78{\mu}{\mu}mol/L$ (mean, SD) by the Hitachi-7600 P-module was compared with that of $4.05{\pm}5.47{\mu}{\mu}mol/L$ by FPIA, coefficients of correlation of 0.988 was obtained. The regression equation was Y (Hitachi-7600 P-module) = 0.9408 x (FPIA) + 0.1316 (r=0.9885, n=60). CVs of MTX measured by Hitachi 7600 P-module was 6.78% at $0.33{\mu}{\mu}mol/L$, 0.96% at $1.16{\mu}{\mu}mol/L$, and 0.96% at $8.04{\mu}{\mu}mol/L$. The precision was excellent in each group. The linearity was acceptable. We evaluated that MTX is light-sensitive on prolonged exposure to direct sunlight. Comparing with the FPIA using TDX, the Hitachi-7600 P-module using EMIT showed good coefficient of correlation and precision. Therefore the Hitachi-7600 P-module can replace the FPIA for quantitative analysis of MTX.

  • PDF