• Title/Summary/Keyword: Fluorescence Materials

Search Result 504, Processing Time 0.027 seconds

The Visualization of Temperature Field for Nanoporous Thin Film using Laser-Induced Fluorescence. (형광 나노포러스 박막의 온도장 가시화)

  • Oh, Young-Su;Baek, In-Gi;Jeon, Pil-Soo;Kim, Hyun-Jung;Yoo, Jai-Suk
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2459-2464
    • /
    • 2007
  • In present study, a temperature field of specimens which was coated with fluorescence dye such as Rhodamine-B(Rh-B) has been measured, based on the fluorescence intensity. Silica(SiO2) nano porous structure with 1um thickness was constructed on a cover glass, and fluorescence dye was digested into these porous thin films. To optimize manufacturing coating process, various solvents, Rh-B concentration, and other chemical materials were applied to fabricate the specimen and all specimens were measured on the various temperature conditions. For the measurement, a 14 bit cooled CCD camera with 1600 by 1200 spatial resolution is equipped with epifluorescence microscope to obtain only fluorescence intensity from 1.2 mm by 0.9 mm field of view of the illuminated coated specimen.

  • PDF

Study on the Detachment of Fluorescent Whitening Agents from White Waster Papers (인쇄용지 재활용을 위한 형광증백제 탈착에 대한 기초연구)

  • Lee, Ji Young;Kim, Chul Hwan;Kim, Eun Hea;Park, Tae Ung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.48 no.2
    • /
    • pp.5-12
    • /
    • 2016
  • White waste papers are very important resources in the paper industry, but their use is limited because of the residual of fluorescent whitening agent (FWA). So the removal of FWAs from waste paper is an important task in the recycling process to improve the use of recycled resources. In this study, we focused on the FWAs used for surface treatments and carried out physical and chemical treatments to remove them from white waste papers. The white waste papers were disintegrated with a surfactant in different pH and temperature conditions, and then handsheets were made for the measurement of the fluorescence index, which is proportional to the amount of FWAs on papers. The effect of the flotation process on the removal of FWAs after disintegration was also investigated. The fluorescence index decreased as the disintegration time increased, but over a relatively long time, the fluorescence index increased again, which indicated the readsorption of the FWAs detached from the cellulosic fibers of the white waste papers. The lowest fluorescence index was shown when the waste papers were disintegrated with a 0.3% surfactant addition at pH 10 and at $45^{\circ}C$. However, the flotation treatment was not effective, because the flotation induced contact between the detached FWAs and the cellulosic fibers, and re-adsorption occurred.

Detection of proximal caries using quantitative light-induced fluorescence-digital and laser fluorescence: a comparative study

  • Yoon, Hyung-In;Yoo, Min-Jeong;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.432-438
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the in vitro validity of quantitative light-induced fluorescence-digital (QLF-D) and laser fluorescence (DIAGNOdent) for assessing proximal caries in extracted premolars, using digital radiography as reference method. MATERIALS AND METHODS. A total of 102 extracted premolars with similar lengths and shapes were used. A single operator conducted all the examinations using three different detection methods (bitewing radiography, QLF-D, and DIAGNOdent). The bitewing x-ray scale, QLF-D fluorescence loss (${\Delta}F$), and DIAGNOdent peak readings were compared and statistically analyzed. RESULTS. Each method showed an excellent reliability. The correlation coefficient between bitewing radiography and QLF-D, DIAGNOdent were -0.644 and 0.448, respectively, while the value between QLF-D and DIAGNOdent was -0.382. The kappa statistics for bitewing radiography and QLF-D had a higher diagnosis consensus than those for bitewing radiography and DIAGNOdent. The QLF-D was moderately to highly accurate (AUC = 0.753 - 0.908), while DIAGNOdent was moderately to less accurate (AUC = 0.622 - 0.784). All detection methods showed statistically significant correlation and high correlation between the bitewing radiography and QLF-D. CONCLUSION. QLF-D was found to be a valid and reliable alternative diagnostic method to digital bitewing radiography for in vitro detection of proximal caries.

Rhodamine 6G Based New Fluorophore Chemosensor Toward Hg2+

  • Son, Young-A;Park, June-Min
    • Textile Coloration and Finishing
    • /
    • v.24 no.3
    • /
    • pp.158-164
    • /
    • 2012
  • Rhodamine dyes belong to xanthene family has excellent photostability and photophysical properties. In rhodamine dyes, Rhodamine 6G and its precursors also have xanthene chromophore and it shows high fluorescent quantum yield. Rhodamine 6G derivates are simple to synthesis and its high sensitivity and water solubility are suitable as good chemosensor. In this regard, Rhodamine 6G derivates which have selectivity to specific metal cation can used to detect various heavy metal ions. In this study, rhodamine 6G derivatives were synthesized by reaction of rhodamine 6G hydrazide and glyoxal and 4-phenyl thiosemicarbazide and it showed colorimetric and fluorescence sensing toward $Hg^{2+}$ ion. This novel chemosensor was analyzed and measured on UV-Vis and fluorescence spectrophotometer. HOMO/LUMO values were also calculated by computational calculation.

Thermally activated delayed fluorescence (TADF) from $Sn^{4+}$-porphyrin complexes and their application to organic light emitting diodes - novel pathway for high efficiency electroluminescence

  • Endo, Ayataka;Ogasawara, Mai;Takahashi, Atsushi;Kato, Yoshimine;Adachi, Chihaya
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1411-1413
    • /
    • 2008
  • We developed $Sn^{4+}$-porphyrin complexes that show thermally activated delayed fluorescence (TADF). TADF intensities increased with an increase of temperature because of an acceleration of the reverse intersystem crossing from triplet to singlet excited states by heat activation. TADF component provides a novel pathway for high efficiency OLEDs.

  • PDF

The Role of Vibrational Coherency in Ultrafast Reaction Dynamics of PYP

  • Chosrowjan, Haik;Mataga, Noboru;Taniguchi, Seiji;Shibata, Yutaka;Hamada, Norio;Tokunaga, Fumio;Imamoto, Yasushi;Kataoka, Mikio
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.122-125
    • /
    • 2002
  • Coherent oscillations in is fluorescence dynamics of W.-t. PYP and its site-directed mutants have been observed. Two oscillatory modes coupled with the ultrafast fluorescence due to the twisting of the excited chromophore were identified, a high ftequency mode (∼135 cm$\^$-1/) with ∼550 is damping time and a low frequency overdamped mode (-45 cm$\^$-1/) with ∼250 is damping time, respectively. Both modes disappear in the fluorescence dynamics of denatured PYP emphasizing the important role of the protein nanospace as the environment for photoreaction. The qualitative picture of fluorescence dynamics in site-directed mutants was rather similar to that in W.-t. PYP, i.e., similar oscillatory modes (∼130-140 cm$\^$-1/ and ∼40-70 cm$\^$-1/) have been observed. This indicates that the vibrational modes and electron-vibration couplings do not change dramatically due to the mutation though the damping time of low frequency mode a little decreases as the protein nanospace structure becomes looser and more disordered by mutation. On the other hand, in the case of some PYP analogues, the qualitative picture of fluorescence dynamics changes, showing the familiar picture of solvation effect whereas the oscillations are almost damped. Comparative analyses of these observations are presented.

  • PDF

Aqueous-Based Photocurrent Generation by Fluorescence Resonance Energy Transfer between Conjugated Oligoelectrolytes and Erythrosin B (전도성 올리고전해질과 에리스로신 B간 형광공명 에너지전달에 의한 수용액 기반 광전류 생성)

  • Kang, Insung;Park, Jonghyup;Jo, Hyunjin;Park, Juhyun
    • Polymer(Korea)
    • /
    • v.39 no.2
    • /
    • pp.353-358
    • /
    • 2015
  • Aqueous-based, environmentally friendly photocurrent generation has been highlighted to produce electricity by mimicking photosynthesis in nature. We fabricated a photocurrent generation system using a conjugated oligoelectrolyte (COE) assembled in lipid vesicles and a fluorescence dye, and investigated the fluorescence resonance energy transfer (FRET) between two species and the influence of FRET on the photocurrent generation. The FRET efficiency from the electron donor, COE, to the electron acceptor, the dye, increased with the dye concentrations, but the photocurrent increased and then decreased with the dye concentrations. We discussed about the role of FRET and electron shuttles over the variation of photocurrent.

Hyperspectral Fluorescence Imaging for Mouse Skin Tumor Detection

  • Kong, Seong G.;Martin, Matthew E.;Vo-Dinh, Tuan
    • ETRI Journal
    • /
    • v.28 no.6
    • /
    • pp.770-776
    • /
    • 2006
  • This paper presents a hyperspectral imaging technique based on laser-induced fluorescence for non-invasive detection of tumorous tissue on mouse skin. Hyperspectral imaging sensors collect image data in a number of narrow, adjacent spectral bands. Such high-resolution measurement of spectral information reveals contiguous emission spectra at each image pixel useful for the characterization of constituent materials. The hyperspectral image data used in this study are fluorescence images of mouse skin consisting of 21 spectral bands in the visible spectrum of the wavelengths ranging from 440 nm to 640 nm. Fluorescence signal is measured with the use of laser excitation at 337 nm. An acousto-optic tunable filter (AOTF) is used to capture images at 10 nm intervals. All spectral band images are spatially registered with the reference band image at 490 nm to obtain exact pixel correspondences by compensating the spatial offsets caused by the refraction differences in AOTF at different wavelengths during the image capture procedure. The unique fluorescence spectral signatures demonstrate a good separation to differentiate malignant tumors from normal tissues for rapid detection of skin cancers without biopsy.

  • PDF

IN VITRO STUDY ON EXOTHERMIC REACTION OF POLYMER-BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS MEASURED BY DIFFERENTIAL SCANNING CALORIMETRY

  • Ko, Mun-Jeung;Pae, Ahran;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.6
    • /
    • pp.690-698
    • /
    • 2006
  • Statement of problems. The heat produced during polymerization of polymer-based provisional materials may cause thermal damage to the vital pulp. Purpose. This study was performed to evaluate the exotherm reaction of the polymerbased provisional materials during polymerization by differential scanning calorimetry and to compare the temperature changes of different types of resins. Material and methods. Three dimethacrylate-based materials (Protemp 3 Garant, Luxatemp Plus, Luxatemp Fluorescence) and five monomethacrylate- based material (Snap, Alike, Unifast TRAD, Duralay, Jet) were selected. Temperature changes of polymer-based provisional materials during polymerization in this study were evaluated by D.S.C Q-1000 (TA Instrument, Wilmington, DE, USA). The following three measurements were determined from the temperature versus time plot: (1) peak temperature, (2) time to reach peak temperature, (3) heat capacity. The data were statistically analyzed using one-way ANOVA and multiple comparison Bonferroni test at the significance level of 0.05. Results. The mean peak temperature was $39.5^{\circ}C({\pm}\;1.0)$. The peak temperature of the polymer-based provisional materials decreased in the following order: Duralay > Unifast TRAD, Alike > Jet > Luxatemp Plus, Protemp 3 Garant, Snap, Luxatemp Fluorescence. The mean time to reach peak temperature was 95.95 sec $({\pm}\;64.0)$. The mean time to reach peak temperature of the polymer-based provisional materials decreased in the following order: Snap, Jet > Duralay > Alike > Unifast TRAD > Luxatemp Plus, Protemp 3 Garant, Luxatemp Fluorescence. The mean heat capacity was 287.2 J/g $({\pm}\;107.68)$. The heat capacity of the polymer-based provisional materials decreased in the following order: Duralay > TRAD, Jet, Alike > Snap, Luxatemp Fluorescence, Protemp 3 Garant, Luxatemp Plus. Conclusion. The heat capacity of materials, determined by D.S.C., is a factor in determining the thermal insulating properties of restorative materials. The peak temperature of PMMA was significantly higher than others (PEMA, dimethacrylate). No significant differences were found among PEMA (Snap) and dimethacrylate (P >0.05). The time to reach peak temperature was greatest with PEMA, followed by PMMA and dimethacrylate. The heat capacity of PMMA was significantly higher than others (PEMA, dimethacrylate). No significant differences were found among PEMA and dimethacrylate (P >0.05).

Synthesis, Crystal Structure, Spectra Characterization and DFT Studies on a Di-Cycle Pyrazoline Derivative

  • Song, Jie;Zhao, Pu Su;Zhang, Wei Guang
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1875-1880
    • /
    • 2010
  • A dicycle pyrazoline derivative, 1-phenyl-5-(p-fluorophenyl)-3,4-($\alpha$-p-fluoro-tolylenecyclohexano) pyrazoline, was synthesized and characterized by elemental analysis, IR, UV-vis, fluorescence spectra and X-ray single crystal diffraction. Density function theory (DFT) calculations were performed by using B3LYP method with 6-$311G^{**}$ basis set. The optimized geometry can well simulate the molecular structure. Vibrational frequencies were predicted, assigned and compared with the experimental values, which suggest that B3LYP/6-$311G^{**}$ method can well predict the IR spectra. Both the experimental electronic absorption spectra and the predicted ones by B3LYP/6-$311G^{**}$ method reveal three electron-transition bands, with the theoretical ones having some red shifts compared with the experimental data. Natural bond orbital analyses indicate that the absorption bands are mainly derived from the contribution of n $\rightarrow\pi^*$ and $\pi\rightarrow\pi^*$ transitions. Fluorescence spectra determination shows that the title compound can emit blue-light at about 478 nm. On the basis of vibrational analysis, the thermodynamic properties of title compound at different temperature have been calculated, revealing the correlations between $C^0_{p,m}$, $S^0_m$, $H^0_m$ and temperature.