• Title/Summary/Keyword: Fluid Power

Search Result 2,844, Processing Time 0.029 seconds

Development of a Machine Control Technology and Productivity Evaluation for Excavator (굴착기 머신 콘트롤 기술 개발 및 생산성 향상 평가)

  • Lee, Min Su;Shin, Young Il;Choi, Seung Joon;Kang, Han Byul;Cho, Ki Yong
    • Journal of Drive and Control
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 2020
  • An intelligent excavator can be divided into Machine Guidance (MG), semi-automatic, and unmanned by technology. The MG technology excavator is equipped with a tilt sensor on each link of the excavator and a GPS is installed on the excavator body to inform the user of the position of the excavator bucket end. Machine control (MC) technology that assists the user's work can be divided into semi-automatic and fully automatic technology. The semi-automatic MC equipment has already been commercialized by Komatsu and Caterpillar. The MC excavator is equipped with an electro-hydraulic system, sensors and controllers to control the excavator bucket end according to the user's needs. In this study, the semi-automated excavator modified based on manual excavator, is equipped with an electro-hydraulic system, a controller system, multi-sensors and a control algorithm is developed to assist in excavation work such as leveling and grading. By applying the developed technology, it was possible to confirm productivity improvement compared to manual digging and leveling work. In the future, further research to improve the accuracy of the hydraulic precision control and collaborative work with heterogeneous construction equipment such as dump truck and automated collaboration tasks technology could be developed.

A New Flow Control Technique for Handling Infinitesimal Flows Inside a Lab-On-a-Chip (랩온어칩 내부 미세유동제어를 위한 새로운 유동제어기법)

  • Han, Su-Dong;Kim, Guk-Bae;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.110-116
    • /
    • 2006
  • A syringe pump or a device using high electric voltage has been used for controlling flows inside a LOC (lab-on-a-chip). Compared to LOC, however, these microfluidic devices are large and heavy that they are burdensome for a portable ${\mu}-TAS$ (micro total analysis system). In this study, a new flow control technique employing pressure regulators and pressure chambers was developed. This technique utilizes compressed air to control the micro-scale flow inside a LOC, instead of a mechanical actuator or an electric power supply. The pressure regulator controls the output air pressure by adjusting the variable resistor attached. We checked the feasibility of this system by measuring the flow rate inside a capillary tube of $100{\mu}m$ diameter in the Re numbers ranged from 0.5 to 50. In addition, the performance of this flow control system was compared with that of a conventional syringe pump. The developed flow control system was found to show superior performance, compared with the syringe pump. It maintains automatically the: air pressure inside a pressure chamber whether the flow inside the capillary tube is on or off. Since the flow rate is nearly proportional to the resistance, we can control flow in multiple microchannels precisely. However, the syringe pump shows large variation of flow rate when the fluid flow is blocked in the microchannel.

Parametric Study of 2.5 kW Class Propeller Type Micro Hydraulic Turbine (2.5 kW 급 프로펠러형 마이크로 수차 매개변수 연구)

  • MA, SANG-BUM;KIM, SUNG;CHOI, YOUNG-SEOK;CHA, DONG-AN;KIM, JIN-HYUK
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.4
    • /
    • pp.387-394
    • /
    • 2020
  • A parametric study of a 2.5 kW class propeller type micro hydraulic turbine was performed. In order to analyze the internal flow characteristics in the hydraulic turbine, three dimensional Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model were used and the hexahedral grid system was used to construct computational domain. To secure the reliability of the numerical analysis, the grid dependency test was performed using the grid convergence index method based on the Richardson extrapolation, and the grid dependency was removed when about 1.7 million nodes were used. For the parametric study, the axial distance at shroud span (L) between the inlet guide vane and the runner, and the inlet and outlet blade angles (β1, β2) of the runner were selected as the geometric parameters. The inlet and outlet angles of the runner were defined in the 3 spans from the hub to tip, and a total of 7 geometric parameters were investigated. It was confirmed that the outlet angles of the runner had the most sensitive effect on the power and efficiency of the micro hydraulic turbine.

ANALYSIS OF HEAT TRANSFER ON SPENT FUEL DRY CASK DURING SHORT-TERM OPERATIONS (사용후핵연료 건식 용기의 단기운영공정 열전달 평가)

  • Kim, H.;Lee, D.G.;Kang, G.U.;Cho, C.H.;Kwon, O.J.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.54-61
    • /
    • 2016
  • When spent fuel assemblies from the reactor of nuclear power plants(NPPs) are transported, the assemblies are exposed to short-term operations that can affect the peak cladding temperature of spent fuel assemblies. Therefore, it needs to perform the analysis of heat transfer on spent fuel dry cask during the operation. For 3 dimensional computational fluid dynamnics(CFD) simulation, it is proposed that the short-term operation is divided into three processes: Wet, dry, and vacuum drying condition. The three processes have different heat transfer mode and medium. Metal transportation cask, which is Korea Radioactive Waste Agency(KORAD)'s developing cask, is evaluated by the methods proposed in this work. During working hours, the boiling at wet process does not occur in the cask and the peak cladding temperatures of all processes remain below $400^{\circ}C$. The maximum peak cladding temperature is $173.8^{\circ}C$ at vacuum drying process and the temperature rise of dry, and vacuum drying process occurs steeply.

A Study on the Boiling Heat Transfer of R-113 in a Concentric Annular Tube (환상이중원관에서 R-113의 비등열전달에 관한 연구)

  • Kim, M.H.;Kim, C.H.;Oh, C.;Yoon, S.H.;Kim, K.K.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.5
    • /
    • pp.12-23
    • /
    • 1994
  • The two-phase flow is observed in power plants, chemical process plants, and refrigeration systems etc., and it is very important to solve the heat transfer mechanism of a boiler, an automic reactor, a condenser and various types of evaporators. Recently, the problem of two phase heat transfer is braught up in many regions with development of energy saving technique. In flow boiling system it is necessary to store data in each condition because the heat transfer characteristics of flow boiling region vary by the change of flow pattern and the magnetude of heat flux to tube length, and be subtly affected by the flow and heating condition. So basic study for knowing flow pattern in heat transfer region and the relation between heat transfer characteristic and flow condition is desired to accumulate data in wide variety of liquid and flow system in the study of heat transfer of two phase flow. In this study R-113 was selected as working fluid whose properties were programmed by least square method, and experiment was conducted in the region of mass flow $1.628{\times}10^6$~$4.884{\times}10^6$/kg/$m^2$hr with inlet subcooling 10~3$0^{\circ}C$, sustaining test section inlet pressure to 1.5kg$_f$/$cm^2$abs.

  • PDF

Optimizing the Configurations of Cooling Channels with Low Flow Resistance and Thermal Resistance (냉각유로 형상변화에 따른 유동 및 열저항 최적화 연구)

  • Cho, Kee-Hyeon;Ahn, Ho-Seon;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this study, we investigated the hydrodynamic and thermal performance of constructal architectures on the basis of the mass flow rates for a given pressure drop, and we determined the thermal resistance and flow uniformity. The five flow configuration used in this study were the first construct with optimized hydraulic diameter, the second construct with optimized hydraulic diameter, the first construct with non-optimized hydraulic diameter, second construct with non-optimized hydraulic diameter, and a serpentine configuration. The results of our study suggest that the best fluid-flow structure is the second constructal structure with optimized constructal configurations. We also found that in the case of the optimized structure of cooling plates, the heat transfer was remarkably higher and the pumping power was significantly lower than those of traditional channels.

Experimental Study on Heat Transfer Characteristics of Thermosyphon Using Nanofluids (나노유체를 이용한 써모사이폰의 열전달 성능 특성에 관한 실험적 연구)

  • Lee, Moo-Yeon;Cho, Chung-Won;Lee, Ho-Seong;Won, Jong-Phil;Lim, Taek-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.11
    • /
    • pp.1073-1079
    • /
    • 2012
  • This study aims to experimentally investigate the heat transfer characteristics of a thermosyphon using nanofluids. A thermosyphon with three individual pipes, which share the internal volume of the evaporator section, was designed, and its performance was tested for various charge amounts, input powers of the evaporator section's heater, and concentrations of working fluids. The optimized charge amount of the thermosyphon using distilled water was 30%, and the thermal resistance of the thermosyphon with $TiO_2$ nanofluid was 18.1% lower than that with Ag nanofluid. In addition, the heat transfer performance of the thermosyphon with $TiO_2-1%$ was optimized at an input power of 300 W at the evaporator section's heater and a charge amount of 30%.

A Comparison Study of CFD Analysis and Flow Visualization on Behavior of Liquid Water in Cathode Channels of PEM Fuel Cells (PEM 연료전지 공기극 유로에서 물의 거동에 대한 CFD 해석과 가시화 실험의 비교 연구)

  • Kim, Hyun-Il;Nam, Jin-Hyun;Shin, Dong-Hoon;Chung, Tae-Yong;Kim, Young-Gyu;Seo, Won-Seok;Lee, Jung-Woon
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.101-108
    • /
    • 2008
  • Polymer electrolyte membrane (PEM) fuel cells are promising power generation devices which are ideal for residential and automobile applications, thanks to their fast transient characteristics. However, liquid water produced in PEM fuel cells should be properly managed to enhance the performances and durabilities of the cells. In this study, a visualization experiment was conducted to investigate the flow behavior of water droplets in cathode channels. The visualization experiment was done with four different model flow channels which were made by varying the material (Acrylic and Teflon) and the channel width (1 mm and 2 mm). Acrylic is hydrophilic (contact angle is about $80^{\circ}$) while Teflon is hydrophobic (contact angle is about $120^{\circ}$). A computational fluid dynamics (CFD) analysis was also performed to compare the observed and the simulated two-phase water/air flow characteristics in cathode channels. The computational models were made to be consistent with the geometries and surface properties of the model flow channels. Both the experimental and numerical results showed that the Teflon cathode channel with 1 mm width has the best water management performance among four model flow channels considered. A close correlation was found between the experimental visualization results and the numerical CFD simulation results.

  • PDF

Performance Evaluation of Vibration Control of Adjacent Buildings According to Installation Location of MR damper (인접건축물의 진동제어를 위한 MR감쇠기의 위치 선정에 관한 연구)

  • Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.91-99
    • /
    • 2012
  • In recently, the vibration control of adjacent buildings have been studied and magneto-rheological(MR) fluid dampers have been applied to seismic response control. MR dampers can be controlled with small power supplies and the dynamic range of this damping force is quite large. This MR damper is one of semi-active dampers as a new class of smart dampers. In this study, vibration control effect according to the installation location of the MR damper connected adjacent buildings has been investigated. Adjacent building structures with different natural frequencies were used as example structures. Groundhook control model is applied to determinate control force of MR damper. In this numerical analysis, it has been shown that displacement responses can be effectively controlled as adjacent buildings are connected at roof floors by MR damper. And acceleration responses can be effectively reduced when two buildings are connected at the mid-stories of adjacent buildings by MR damper. Therefore, the installation floor of the MR damper should be selected with seismic response control target.

Remediation of Electroplating Contaminated Soil by a Field Scale Electrokinetic System with Stainless Steel Electrodes

  • Yuan, Ching;Tsai, Chia-Ren;Hung, Chung-Hsuang
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.5
    • /
    • pp.26-34
    • /
    • 2014
  • A $1.5m(L){\times}1.0m(W){\times}1.1m(H)$ polypropylene (PP) field scale electroniketic system coupled with stainless steel electrodes was designed to examined metal removal performance applied 0.2-0.35 V/cm potential gradient and 0.05-0.5M lactic acid for 20 day. Electroosmosis permeabilities of $2.2{\times}10^{-5}cm^2/V-s$ to $4.8{\times}10^{-5}cm^2/V-s$ were observed and it increased with the potential gradient increased. The reservoir pH controlled at $7.0{\pm}1.0$ has been effectively diminished the clogging of most metal oxides. The best removal efficiency of Zn, Pb, and Ni was 78.4%, 84.3%, and 40.1%, respectively, in the field scale EK system applied 0.35 V/cm and 0.05M lactic acid for 20 days. Increasing potential gradient would more effectively enhance metal removal than increasing concentration of processing fluid. The reservoir and soil temperatures were majorly related to potential gradient and power consumptio. A $4-16^{\circ}C$ above room temperature was observed in the investigated system. It was found that the temperature increase in soil transported the pore water and metals from bottom to the topsoil. This vertical transport phenomenon is critical for the electrokinetic process to remediate in-situ deep pollution.