• 제목/요약/키워드: Fluid Leakage

검색결과 485건 처리시간 0.031초

방사성핵종 뇌조조영술의 조기 동적 영상으로 뇌척수액 누출을 증명한 자발성 두개 내 저압 1예 (A Case of Spontaneous Intracranial Hypotension: Detection of Cerebrospinal Fluid Leakage by Early Dynamic Radionuclide Cisternography)

  • 김재수;양대웅;박석건
    • 대한핵의학회지
    • /
    • 제33권2호
    • /
    • pp.184-188
    • /
    • 1999
  • Although cerebrospinal fluid leakage is suggested as one of the causes of spontaneous intracranial hypotension, only a few cases with direct evidence of cerebrospinal fluid leakage on radionuclide cisternography have been reported in the literature. Indirect evidences of cerebrospinal fluid leakage such as early visualization of the soft tissue and bladder or delayed migration of radiotracer have been observed in most patients with spontaneous intracranial hypotension. We report a case of spontaneous intracranial hypotension in which cerebrospinal fluid leakage was directly demonstrated by early dynamic imaging of spine on radionuclide cisternography. We suggest that early dynamic imaging of spine is an important adjunctive procedure in detecting cerebrospinal fluid leakage in patients with spontaneous intracranial hypotension.

  • PDF

발전용 밸브 유체누설 측정 데이터의 통계적 평가 및 누설량 예측 연구 (Study on Statistical Analysis of Measured Fluid Leakage Data and Estimation of the Leakage Rate for Power Plant Valve)

  • 이상국;김대웅;김양석;박종혁;정훈
    • 동력기계공학회지
    • /
    • 제13권5호
    • /
    • pp.59-66
    • /
    • 2009
  • High temperature and pressure valves in power plant have been used for fluid flowing and leakage occurred owing to valve internal damage such as disc wear, crack and inserting of foreign objects etc. in these valves. Recently, multi-measuring technique applied both ultrasonic and acoustic method have been used for evaluation of valve internal leakage in order to raise measurement reliability. Therefore, we have performed various leakage tests using ultrasonic and acoustic measuring system and acquired leakage data for the various leakage conditions. In this study, we developed the estimation method of regression model through leakage data, and expectation method for valve opening ratio, which is directly proportion to leakage rate, using the established estimation model from the measured data, valve size and fluid pressure so as to enhance data reliability. As a result of this study, it was founded that expectation method of leakage rate by statistical analysis method is appropriate to valve leakage evaluation.

  • PDF

Subarachnoid Hemorrhage Presenting with Seizure due to Cerebrospinal Fluid Leakage after Spinal Surgery

  • Bozkurt, Gokhan;Yaman, Mesut Emre
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권1호
    • /
    • pp.62-64
    • /
    • 2016
  • Cerebrospinal fluid leakage may commonly occur during spinal surgeries and it may cause dural tears. These tears may result in hemorrhage in the entire compartments of the brain. Most common site of such hemorrhages are the veins in the cerebellar region. We report a case of hemorrhage, mimicking aneurysmal subarachnoid hemorrhage due to a cerebrospinal fluid leakage following lumbar spinal surgery and discuss the possible mechanisms of action.

Investigation of Leakage Characteristics of Straight and Stepped Labyrinth Seals

  • Kim, Tong-Seop;Kang, Soo-Young
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권3호
    • /
    • pp.253-259
    • /
    • 2010
  • Leakage characteristics of two labyrinth seals with different configurations (straight vs stepped) were investigated. Leakage flows were predicted by computational fluid dynamics (CFD) for the two configurations and compared with test data. A semi-analytical leakage prediction tool was also tried to predict the leakage. It was confirmed that the CFD gives quite good agreements with test data. The analytical tool also yielded similar leakage behaviors with test results, but the overall agreement with test data was not as good as that of the CFD. The effect of flow direction in the stepped seal on leakage flow was examined. The dependence of leakage performance, in terms of flow function, on the seal clearance size was investigated. Flow function decreased with decreasing clearance in the straight seal, while the trend was reversed in the stepped seal.

CFD를 사용한 터보기계 비접촉식 실의 누설량 예측 (Prediction of Non-Contact-Type Seal Leakage Using CFD)

  • 하태웅
    • 한국유체기계학회 논문집
    • /
    • 제9권3호
    • /
    • pp.14-21
    • /
    • 2006
  • Leakage reduction through annular type seals of turbomachinery is necessary for enhancing their efficiency and the precise prediction method of seal leakage is needed. The analysis based on Bulk-flow concept has been mainly used in predicting seal leakage. However, full Navier-Stokes Equations with turbulent model derived in the seal flow passage have to be solved for improving the prediction of seal leakage. FLUENT 6 which is commercial CFD(Computational Fluid Dynamics) code based on FVM(Finite Volume Method) and SIMPLE algorism has been used to analyze leakage of various non-contact-type seals in this presentation. Comparing with the results of Bulk-flow model analysis and experiment, the result of CFD analysis shows good agreement with that of existing theoretical analysis for the incompressible grooved seal and compressive plain and staggered seal. The CFD analysis also shows improvement on the leakage prediction of the incompressible plain seal and compressive see-through-type labyrinth seal.

중수로 냉각재 펌프용 미케니컬 페이스 실의 성능 해석 (Performance Analysis of Mechanical Face Seal Used for Primary Heat Transport Pump in Heavy Water Reactor)

  • 김정훈;김동욱;김경웅
    • Tribology and Lubricants
    • /
    • 제27권5호
    • /
    • pp.240-248
    • /
    • 2011
  • Mechanical face seal installed in primary heat transport pump used for heavy water reactor prevents leakage of working fluid using thin working fluid film between primary seal ring and mating ring. If the leakage of working fluid exceeds the allowable volume, serious accident can be happened by the trouble of primary heat transport pump. The thinner fluid film exists between primary seal ring and mating ring, the less working fluid leaks out. On the other hand, if the thickness of fluid film is not enough, the life of mechanical face seal will be reduced by friction and wear. Therefore appropriate design is necessary to maximize the performance and life of mechanical face seal. In this study, numerical analysis using finite volume method was conducted to investigate the performance of mechanical face seals which have same deep straight groove and 11 different net coning values. As results, equilibrium clearance between primary seal ring and mating ring, leakage volume of working fluid, friction torque on sealing surface and stiffness of working fluid film were obtained. With increasing net coning value, equilibrium clearance and leakage volume increase, and friction torque and stiffness of fluid film decrease.

보일러 급수 펌프용 미케니컬 페이스 실의 정특성 해석 (Static Characteristic Analysis of Mechanical Face Seal Used for Boiler Feedwater Pump)

  • 김동욱;진성식;김준호;김경웅
    • Tribology and Lubricants
    • /
    • 제26권4호
    • /
    • pp.230-239
    • /
    • 2010
  • Mechanical face seal installed in boiler feedwater pump prevents leakage of working fluid using thin fluid film between stator and rotor. If the leakage of working fluid exceeds the allowable volume, serious malfunction of boiler feedwater pump will be happen. The thinner fluid film exists between stator and rotor, the less working fluid leaks out. However, if the thickness of fluid film is not enough, the wear of seal face will be increased. And it causes the decrease in life of mechanical face seal. Therefore appropriate design is necessary to maximize the performance and life of mechanical face seal. In this study, numerical analysis using finite volume method was conducted to investigate the static characteristics of wavy mechanical face seals which have 4 different wavy surface profiles on rotor. As a result, opening force, leakage volume of working fluid and friction torque were obtained. For the same minimum film thickness, the static characteristics of mechanical face seal were affected by the wavy surface profile which can change the thickness of working fluid film and pressure distribution.

다중계측기법을 이용한 원전 주증기배수밸브의 현상태 누설진단에 관한 연구 (A Study on the As-Built Leakage Diagnosis of Main Steam Drain Valves for Nuclear Power Plants by Multi-measuring Technique)

  • 김성영;김영범;김도형;이상국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2606-2611
    • /
    • 2008
  • The high energy fluid leakage from the high temperature and high differential pressure drop system of NPPs (Nuclear Power Plants) decreases efficiency and consequently leads to considerable economic loss due to less power production. Also, the leakage possibly damages critical parts of components such as valve and trim with the effect of cavitation, flashing, and erosion, etc. and deteriorates its performance. Thus, in this study, we diagnosed the as-is leakage for four (4) main steam drain valves and two (2) steam traps of Yonggwang 1,2 units during normal operation by using multi-measuring technique and observed the occurrence of fine leakage. In the course of measuring fluid leakage, the sign of fine leakage is estimated to be the leakage from orifice. By converting the leakage to energy loss, it is equivalent to the amount of several hundred thousand won per each unit, which supports the basis for the justification of fine leakage.

  • PDF

Diffusion Range and Pool Formation in the Leakage of Liquid Hydrogen Storage Tank Using CFD Tools

  • Kim, Soohyeon;Lee, Minkyung;Kim, Junghwan;Lee, Jaehun
    • 공업화학
    • /
    • 제33권6호
    • /
    • pp.653-660
    • /
    • 2022
  • In liquid hydrogen storage tanks, tank damage or leakage in the surrounding pipes possess a major risk. Since these tanks store huge amounts of the fluid among all the liquid hydrogen process facilities, there is a high risk of leakage-related accidents. Therefore, in this study, we conducted a risk assessment of liquid hydrogen leakage for a grid-type liquid hydrogen storage tank (lattice-type pressure vessel (LPV): 18 m3) that overcame the low space efficiency of the existing pressure vessel shape. Through a commercially developed three-dimensional computational fluid dynamics program, the geometry of the site, where the liquid hydrogen storage tank will be installed, was obtained and simulations of the leakage scenarios for each situation were performed. From the computational flow analysis results, the pool formation behavior in the event of liquid hydrogen leakage was identified, and the resulting damage range was predicted.

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • 유공압시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF