• Title/Summary/Keyword: Fluid Intake

Search Result 291, Processing Time 0.028 seconds

Fluid intake, hydration status and its association with cognitive function among adolescents in Petaling Perdana, Selangor, Malaysia

  • Tung, Serene En Hui;Ch'ng, Yi Zhang;Karnan, Thaneswary V;Chong, Pei Nee;Zubaidah, Jamil Osman;Chin, Yit Siew
    • Nutrition Research and Practice
    • /
    • v.14 no.5
    • /
    • pp.490-500
    • /
    • 2020
  • BACKGROUND/OBJECTIVES: A cross-sectional study was undertaken to evaluate fluid intake and hydration status in association with cognitive function among 230 adolescents (10-14 years of age) in Petaling Perdana, Selangor, Malaysia. SUBJECTS/METHODS: Urine color was used to measure hydration status, while fluid intake was assessed using the 15-item beverage intake questionnaire. Cognitive function was assessed using the Wechsler Intelligence Scale for Children, Fourth Edition. RESULTS: More than half of the adolescents were mildly or moderately dehydrated (59.6%) and only one-third (33.0%) were well hydrated. Among the daily fluid types, intakes of soft drinks (r = -0.180; P = 0.006), sweetened tea (r = -0.184; P = 0.005) and total sugar-sweetened beverages (SSBs) (r = -0.199; P = 0.002) were negatively correlated with cognitive function. In terms of hydration status, cognitive function score was significantly higher (F-ratio = 4.102; P = 0.018) among hydrated adolescents (100.38 ± 12.01) than in dehydrated (92.00 ± 13.63) counterparts. Hierarchical multiple linear regression analysis, after adjusting for socio-demographic factors, showed that soft drinks (β = -0.009; P < 0.05) and sweetened tea (β = -0.019; P < 0.05) negatively predicted cognitive function (ΔR2 = 0.044). When further control for sources of fluid, hydration status (β = -2.839; P < 0.05) was shown to negatively predict cognitive function (ΔR2 = 0.021). The above variables contributed 20.1% of the variance in cognitive function. CONCLUSIONS: The results highlight the links between fluid intake (soft drinks, sweetened tea, total SSBs) and hydration status with cognitive function in adolescents. Interventions aimed at decreasing the consumption of SSBs and increasing hydration status through healthy fluid choices, such as water, could improve cognitive performance in adolescents.

Measuring Fluid Balance in Patients with Cancers: Comparison between Cumulative Intake and Output Records and Body Weight Change (암환자의 수분 균형 상태 사정 방법 비교: 수분 섭취 및 배설량 측정법과 체중측정법)

  • Lee, Jin-Hong;Park, Hee-Jung;Kim, Jeong-Hwa;Suh, Eun-Young
    • Asian Oncology Nursing
    • /
    • v.11 no.3
    • /
    • pp.247-253
    • /
    • 2011
  • Purpose: The purpose of the study was to evaluate the accuracy of two different fluid intake measurement methods (fluid only vs. all dietary intake) in measuring fluid balance compared to body weight change among patients with cancers. Methods: A total of 60 cancer patients in an urban cancer center in South Korea participated in the study. Adult patients who were over 18 years old; having 24-hour I&O order; and taking either normal regular diet or soft blend diet were included. Demographic information and disease related information were also gathered. The data were analyzed using SPSS 18.0 program. Results: Measuring 'fluid only' for oral intake was a more accurate measure than measuring 'all dietary intake' (p=.026 vs. p=.094). Both methods had positive correlations with the amount of weight change (r=.329, p=.010; r=.303, p=.019). Measuring body weight was a more accurate and efficient way of evaluating the fluid balance than 24 hour cumulative I&O. Conclusion: Developing clinical manual for selecting proper patients who needs fluid balance monitoring is imperative. Administering weight check and/or 24 hour cumulative I&O should be considered thoroughly based on solid nursing evidence in future.

Influence of intake runner cross section design on the engine performance parameters of a four stroke, naturally aspirated carbureted SI engine

  • Singh, Somendra Pratap;Kumar, Vasu;Gupta, Dhruv;Kumar, Naveen
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 2015
  • The current scenario of the transportation sector reflects the urgent need to address issues such as depletion of traditional fuel reserves and ever growing pollution levels. Researchers around the world are focussing on alternatives as well as optimisation of currently employed devices to reduce the pollution levels generated by the commonly used fuels. One such optimisation involves the study of air flow within the intake manifolds of SI engines. It is a well-known fact that alterations in the air manifolds of engines have a significant impact on the engine performance parameters, fuel consumption and emission levels. Previous works have demonstrated the impacts of runner lengths, diameter, plenum volume, taper angle of distribution manifolds and other factors on in-cylinder fluid motion and engine performance. However, a static setup provides an optimal configuration only at a specific engine speed. This paper aims to investigate the variations in the same parameters on a four stroke, naturally aspirated single cylinder SI engine through varying the cross section design over the intake runner with the aid of Computational Fluid Dynamics. The system consists of segments that form the intake runner with projections on the inside that allow various permutations of the intake runner segments. The various configurations provide the optimised fluid flow characteristics within the intake manifold at specific engine speed intervals. The variations such as turbulence, air fuel mixing are analysed using the three dimensional CFD software FLUENT. The results can be used further for developing an automated or manually adjustable intake manifold.

Reduction of Aeroacoustic Noise from Intake Head of a Vacuum Cleaner (진공청소기 흡입유로의 공력소음 개선)

  • Koo, Jeong-Su;Hwang, Won-Gul;Oh, Il-Kwon;Oh, Jang-Guen;Song, Hwa-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.202-207
    • /
    • 2006
  • The aeroacoustic noise from intake head of a vacuum cleaner is caused by complicated transient pressure fluctuation and it greatly affects the overall SPL of the vacuum cleaner. In this study, we intended to decrease the overall SPL by reducing the aeroacoustic noise from intake head. In the first the place, we analyzed the aeroacoustic noise from the unsteady fluid analysis of intake head. And then, we grasped the dominant frequency band from the aeroacoustic noise by comparing the spectrum distributions between examinations and analyses. Also, we systematically investigated the aeroacoustic noise sources from each part composing the intake head. Consequently, we redesigned each part of the dominant noise sources and suggested the modified intake head, resulting in the reduction ortho overall SPL by 3.6dB(A).

  • PDF

Analysis of difference in body fluid composition and dietary intake between Korean adults with and without type 2 diabetes mellitus (한국성인의 제2형 당뇨병 유무에 따른 체액 조성 차이 및 영양소 섭취량 분석)

  • Yu-Gyeong Kim;Ha-Neul Choi ;Jung-Eun Yim
    • Journal of Nutrition and Health
    • /
    • v.56 no.4
    • /
    • pp.377-390
    • /
    • 2023
  • Purpose: Diabetes mellitus (DM) causes body fluid imbalance because of hyperglycemia, but there is a lack of research on the relationship between DM and body fluid imbalance in the Korean population. This study compared the differences in body fluid composition and dietary intake between individuals with type 2 DM (T2DM) and a normal control (NC) group without the disease. Methods: In this study, 36 subjects with T2DM and 21 without diabetes were divided into the T2DM and NC groups. The subjects were divided into four subgroups to assess differences in body fluid volume according to sex: men T2DM group (n = 24), men NC group (n = 9), women T2DM group (n = 12), and women NC group (n = 12). The body fluid composition was measured using bioelectrical impedance analysis, including intracellular water (ICW), extracellular water (ECW), total body water (TBW), ECW/ICW, and ECW/TBW. Nutrient intake was evaluated using their dietary records. Results: The results showed that the ECW/ICW and the ECW/TBW were significantly higher in the T2DM group compared to the NC group. Both men and women in the T2DM group showed significantly higher ECW/ICW and ECW/TBW than the respective NC group. The T2DM group had a higher carbohydrate, dietary fiber, vitamin A, vitamin C, sodium, and potassium intake per 1,000 kcal and lower total daily energy, fat, and cholesterol intake per 1,000 kcal than the NC group. Conclusion: These results suggest a positive association between T2DM and body fluid imbalance. This study can be used widely as basic data for the evaluation and diagnosis of diabetic complications in the future.

Nurses' Perception and Practice of Fluid Intake and Output Measurement (간호사의 수분 섭취배설량 측정에 대한 인식도와 수행도)

  • Kang, Nam-Yi;Ahn, Sukhee
    • Journal of muscle and joint health
    • /
    • v.23 no.2
    • /
    • pp.84-94
    • /
    • 2016
  • Purpose: This research aimed to identify levels of nurses' perception and practice of fluid intake and output (I & O) measurement and to explore the relationship between perception and practice of it. Methods: Using a cross-sectional survey design, 195 nurses who practiced fluid I & O measurement were recruited from a general hospital. Nurses who agreed to participate in this study completed a structured study questionnaire to assess their levels of perception and practice of fluid I & O measurement. Results: A level of perception of I & O measurement was high (3.46 points out of 5), and scores for 3 subdomains of I & O (importance, accuracy, and efficacy) were evenly high. The level of practice of I & O was fairly high (3.76 points out of 5). Perception and practice of I & O were highly correlated (r=.73, p<.001). Conclusion: Nurses seem to have higher levels of perception and do practice fluid I & O measurement correctly. In order to have reliable and valid I & O measures, nurses need to have continuous education on I & O measurement based on clinical guideline to utilize it as an invaluable clinical instrument.

A Study on Fluid Flow in the Intake Manifold for an Engine (엔진 흡기관내의 유체유동에 관한 연구)

  • 성낙원;이응석;강건용;엄종호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.295-307
    • /
    • 1988
  • In order to predict performance of the intake manifold, which is dependent on the length and diameter of a resonance pipe, the Fluid Dynamic Model for 4-cylinder diesel engine is developed using two step Lax-Wendroff method to solve the governing equations of air flow in the intake system. Boundary conditions at the intake valve, branch at the manifolds, and pipe end are also modeled. The results of the models are compared with the experimental results of a motored engine. The model is capable of predicting the real phenomena satisfactorily with reasonable computing time.

Numerical Analysis on the Flow Vortex in a Multi Pump Intake using a Pump Sump Model (다중 펌프 흡수정에서 발생하는 Vortex 수치 해석에 관한 연구)

  • Park, No-Suk;Kim, Seong-Su;Hyun, Sang-Rak;Park, Jong-Ho;Ahn, Young-Seog
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.211-217
    • /
    • 2010
  • In order to suggest the methodology for achieving anti-vortex within multi pump intake well, the field test and CFD(Computational Fluid Dynamics) simulation were conducted. The filed test were carried out for domestic W_multi pump intake well according to usual operation condition through the naked observation. From the results, operating #4, #5, #8 and 9# pumps, the vortex and swirl occurred above #4 and #9 intake pipe within two wells. For qualitative analysis, a commercial CFD code, using sump model, was used to predict the vortex generation within the selected pump intake facility accurately. The analysed results by CFD show that the vortex structure and location are in accordance with the results of the field test.

Measurement of Nonlinear Time-variant Source Characteristics of Intake and Exhaust Systems in Fluid Machines

  • Jang Seung-Ho;Ih Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3E
    • /
    • pp.87-89
    • /
    • 2005
  • The acoustical sources of intake and exhaust systems in fluid machines are often characterized by the source impedance and strength using linear frequency-domain modeling. In the case of the sources which are nonlinear and time-variant, however, the source parameters were sometimes incorrectly obtained. In this paper, the source model and direct measurement technique are modified in order to evaluate the effect due to nonlinear and periodically time-varying source character as well as the linear property of the reflectivity of in-duct fluid machine source. With a priori known kinematical information of the source, the types of nonlinear time-variant terms can be presumed by a simple physical model, in which there is practically no restriction on the form of the model. The concept of source impedance can be extendable by introducing the linear frequency response function for each nonlinear or time-variant input. Extending the conventional method and adapting the reverse MISO technique, it is possible to develop a direct method that can deal with the nonlinear time-variant source parameters. The proposed direct method has a novel feature that there is no restriction on the probability or spectral natures of the excited sound pressure data. The present method is verified by the simulated measurements for simplified fluid machines. It is thought that the proposed method would be useful in predicting the insertion loss or the radiated sound level from intake or exhaust systems.

Relationship between Intake and Output Balance and Body Weight Changes in Intensive Care Unit Patients (중환자의 체중변화와 섭취량과 배설량 균형과의 관계)

  • Kim, Hwa-Soon;Lee, Young-Whee;Lee, Ji-Soo;Lee, Jin-Young;Choo, Sang-Soon;Lee, Bo-Gyeong
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.2
    • /
    • pp.168-176
    • /
    • 2011
  • Purpose: The purpose of this study was to identify differences between intake and output balance and body weight changes and to identify factors related to differences in critically ill patients. Methods: The participants for this descriptive correlational study were 65 medical surgical ICU patients. The data were collected from patient medical records. Results: Mean age of the patients was 63.80 years (${\pm}15.21$). Body weight changes for 48 hours averaged 281.54g (${\pm}2210.48$). I&O balance for 48 hours corrected for insensible loss averaged 398.1ml. Differences ranged from 45mL to 7,535mL. In the distribution of absolute difference between body weight change and intake and output balance, only 40% of the patients were within less than 1,000 mL. Factors relating to accurate measure of intake and output were ventilation methods, respiration patterns, and edema status. Conclusion: Although mean values of weight change and I&O balance for all patients were very close, the range of differences was very wide indicating that, for many patients, intake and output is not an appropriate indicator of body fluid balance. Therefore, because of the frequency fever and/or hyperventilation, nurses need to use caution when using intake and output balance only to estimate current body fluid status for critically ill patients.