• 제목/요약/키워드: Fluid Effect

검색결과 3,867건 처리시간 0.032초

Fluid Bounding Effect on Natural Frequencies of Fluid-Coupled Circular Plates

  • Jhung, Myung-Jo;Park, Young-Hwan;Jeong, Kyeong-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제17권9호
    • /
    • pp.1297-1315
    • /
    • 2003
  • This study deals with the free vibration of two identical circular plates coupled with a bounded or unbounded fluid. An analytical method based on the finite Fourier-Bessel series expansion and Rayleigh-Ritz method is suggested. The proposed method is verified by the finite element analysis using commercial program with a good accuracy The case of bounded or unbounded fluid is studied for the effect on the vibration characteristics of two circular plates. Also, the effect of gap between the plates on the fluid-coupled natural frequencies is investigated.

마황(麻黃), 계지(桂枝), 세신(細辛), 부자(附子)와 관련 처방의 의미(意味)에 대(對)한 소고(小考) (Literature investigation on the meaning of Mahwang, Gyeji, Sesin, Buja and Related Prescriptions)

  • 이태희
    • 대한한의학방제학회지
    • /
    • 제26권3호
    • /
    • pp.261-265
    • /
    • 2018
  • Objective : This discussion was performed in order to find a meaning of Mahwang, Gyeji, Sesin, Buja and Related Prescriptions connected to the distribution problem of body fluid caused by inflammation. Methods : The pharmacological effects of the prescriptions including Mahwang, Gyeji, Sesin, Buja and these herbs which are used as an individual case were investigated literally. Results : Mahwang, Gyeji, Sesin, Buja and the prescriptions including these herbs have the effect of strengthening heart and increasing cardiac output. Therefore it can be thought that the effect of distributing body fluid is included in the Mahwang, Gyeji, Sesin, Buja and Related Prescriptions. And especially the effect of mahwang could not be restricted to the diaphoretic effect. The effect of Mahwang could be interpreted as the distributing body fluid effect through the stimulation of sympathetic nervous system and inhibition of parasympathetic system. Conclusion : Mahwang, Gyeji Sesin and Buja and related prescriptions have the effect of distributing body fluid via stimulation of sympathetic system.

시추 안정액 배합설계에 따른 공벽 붕괴방지 효과에 관한 실험적 연구 (Experimental Study on the Effect of Drilling Fluid with Different Mix Designs for Bore Hole Collapse Prevention)

  • 유충식;최정혁;한윤수
    • 한국지반공학회논문집
    • /
    • 제31권1호
    • /
    • pp.15-24
    • /
    • 2015
  • 본 논문에서는 지반 시추시 공벽붕괴 방지를 위해 적용되는 시추 안정액(drilling fluid)의 다양한 배합설계에 따른 공벽붕괴 방지 효과에 대한 실험적 연구 결과를 다루었다. 이를 위해 먼저 벤토나이트 계열 안정액의 공벽 붕괴 방지 메카니즘을 검토하였으며 아울러 벤토나이트계 안정액의 배합(conditioning)에 따른 안정액의 성능지표 변화에 대한 실험결과를 간략히 기술하였다. 또한 지반시추(굴착) 및 안정액 투입을 간략히 모사하는 토조 장치를 구축하여 세립분이 20% 포함된 화강풍화토 및 모래지반을 대상으로 다양한 배합으로 조성된 벤토나이트계 안정액에 대한 실험을 수행하고 안정액 투입량, 수평 침투범위, 굴착가능 깊이 등을 측정하여 공벽붕괴 방지 효과를 고찰하였다. 그 결과 벤토나이트에 폴리머를 추가할 경우 안정액 투입량 및 수평 침투범위가 굴착가능 깊이가 증가하는 것으로 나타났으며 폴리머의 공벽유지 기능 향상 정도는 모래층보다 화강풍화토 지반에서 보다 뚜렷하게 발휘되는 것으로 검토되었다. 본 논문에서는 도출된 연구결과가 실무적 차원에서 지니는 의미에 대한 내용을 기술하였다.

부분적으로 유체가 채워진 원통형 관내의 외팔보 진동해석 (Vibration Analysis of an Cantilever Beam in Partially Liquid-Filled Cylindrical Pipe)

  • 권대규;유계형;방두열;이성철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1073-1078
    • /
    • 2003
  • This paper presents the vibration characteristics of a cantilever beam in contact with a fluid using a PZT actuator and PVDF film. dynamic behaviors of a flexible beam-water interaction system are examined. The effect of the liquid level on free vibration of the composite beam in a partially liquid-filled circular cylinder is investigated. The coupled system is subject to an undisturbed boundary condition un the fluid domain. In the vibration analysis of a wetted beam. the decoupled analyses between beam and fluid have been conventionally employed by considering first the composite beam vibration in the all and secondly Performing the correction taking account for surrounding fluid effects. That is, this investigation was to look at how natural frequencies, mode shapes. and damping are affected by liquid level variations. The signals from the sensor according to the applied input voltage are digitalized and filtered in order to obtain the dynamic characteristics of the composite beam in contact with fluid. It was found that the coupled natural frequencies decreased with the fluid level for the identical composite beam due to added mass effect. In case of the free-free boundary condition, the natural frequency gently decreased at fluid water level between 20% and 80% in the first tending mode and we found out the bends of stair shape for added mass effect of the fluid.

  • PDF

효과적인 VFX 수중 폭발효과 구현을 위한 유체 시뮬레이션 제어 (Fluid Simulation Control for Effective VFX Underwater Explosion Effects)

  • 황민식;이현석
    • 한국멀티미디어학회논문지
    • /
    • 제20권9호
    • /
    • pp.1606-1618
    • /
    • 2017
  • The explosion effect of computer graphics Visual Effects(VFX) used in films and animations is an important element that determines the completeness of the film, and its usage is getting extended. The realistic explosion effect of VFX should be made according to observations and analysis of various factors of actual explosion in real world. This experimental research would suggest the efficient production guideline for the technical characteristics of underwater explosion of VFX. For this research process, first, the comparison of actual explosion and VFX explosion effect, classification of actual explosion, and characteristics of underwater explosion effect will be addressed. Second, based on the literature reviews, the four steps of experimental production analysis tool will be derived. Third, the experimental research will be processed in along with technical factors four steps of the underwater explosion effect, (1)realistic creation and emission of fluid, (2)fluid expansion control by water pressure, (3)bubble effect, and (4)motion of bubble & dissipation of fluid. The effective method of fluid simulation production will be verified through experimental studies based on the characteristics of the actual explosion process. This experimental study suggested the VFX production technique is expected to be used as the basic data for related research field.

밸브 후단 피팅에 따른 밸브 용량계수의 영향 평가 (Evaluation of the Effect on the Valve Flow Coefficient by Attached Fitting)

  • 강승규;이원식;윤준용;민경화
    • 한국유체기계학회 논문집
    • /
    • 제6권4호
    • /
    • pp.29-37
    • /
    • 2003
  • This study was undertaken to verify the effect of flow coefficient when a globe control valve was attached by different type of fitting. The valve flow coefficient is usually determined by measuring the flow rate and the pressure drop with the connection of straight pipe through the valve. The effect of different fitting that is mounted on the downstream of the valve is studied. Four types of fittings and three distances between the valve and a downstream fitting are compared parametrically to investigate the effect on the flow coefficient of it. Measured flow coefficient and numerically predicted value by using computational fluid dynamics were compared in detail. It is concluded that the flow coefficient is reduced if the fitting is attached after a valve, but the effect of different type of fitting is not crucial.

배플을 갖는 원통형 유체저장 탱크의 연성진동해석 (Coupled Vibration Analysis of Cylindrical Fluid-storage Tanks with a Baffle)

  • 김영완
    • 한국소음진동공학회논문집
    • /
    • 제15권1호
    • /
    • pp.96-104
    • /
    • 2005
  • The coupled vibration characteristics for the fluid-structure interaction systems are investigated through the finite element method. The present paper is focused on vibration characteristics of the cylindrical fluid-storage tank with a baffle. The tank is partially filled with an inviscid and irrotational fluid having a free surface. A baffle is assumed here to have the shape of a thin annular plate and a conical shell, attached to the cylindrical tank and positioned below the fluid surface. The liquid domain is limited by a rigid flat bottom. As the effect of free surface waves is taken into account in the analysis, the bulging and sloshing modes are studied. To demonstrate the validity of present results, they are compared with the published ones. The effect of positions and inner-to-outer radius ratio of annular baffle and setting angles of conical baffle on coupled vibration characteristics is investigated.

A Feasibility Study on the 3-Dimensional Flow of the Jet under the Static Electromagnetic Field

  • Cho I. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.144-145
    • /
    • 2003
  • A feasibility study on the alternating jet flow under the static electromagnetic field was carried out. When a fluid with electrical conductivity lies in the static electromagnetic field and moves electric current occurs in the fluid. Due to the electromagnetic field and the electric current, lorentz force generates in the fluid, which undergo the 'breaking' effect to the fluid. In order to simulate the complex fluid flow in the magnetic field, electromagnetic and fluid flow analysis need to be solved simultaneously. In the present study, a SOLA (SOLution Algorithm) scheme was used in order to calculate electromagnetic and fluid flow field. Jet flow without an electromagnetic field was compared with analytical solution in order to validate the flow analysis scheme. Effect of jet velocity on the flow pattern down the jet was investigated.

  • PDF

MR유체 엔진마운트의 성능해석 (Performance Analysis of a Magneto-Rheological Fluid Engine Mount)

  • 안영공;김원철;양보석
    • 소음진동
    • /
    • 제8권3호
    • /
    • pp.457-466
    • /
    • 1998
  • This paper evaluates the performance of a Magneto-Rheological (MR) fluid mount. The mount incorporates MR fluid in a conventional fluid mount to open and closed the inertia track between the fluid chambers of the mount. It is shown that such switching of the inertia track improves the mount's isolation effect, by eliminating the large transmissibility peak that commonly exists at frequencies higher than the notch frequency for conventional fluid mounts. The switching frequencies of the MR mount is evaluated, based on the parameters of the mount. A simple control scheme for switching the mount between the open and closed states is proposed, and the performance of the controlled mount is compared with conventional mounts. A sensitivity analysis is conducted to evaluate the effect of parameter errors in estimating the switching frequencies and mount performance. The results show that the switching frequencies can be accurately determined from mount parameters that are easily measured or estimated.

  • PDF