• Title/Summary/Keyword: Fluid

Search Result 20,029, Processing Time 0.053 seconds

Relationship between the Oral Cavity and the Stomach of Helicobacter pylori (구강과 위내 Helicobacter pylori의 상호관련성)

  • Kang, Seung-Woo;Ryu, Ji-Won;Yoon, Chang-Lyuk;Ahn, Jong-Mo
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.2
    • /
    • pp.101-110
    • /
    • 2010
  • Helicobacter pylori(H. pylori) is bacterial infection, with more than half of the world population infected and oral cavity is considered second reservoir of H. pylori infection. The purpose of this study was to evaluate role of oral cavity in H. pylori infection by comparison of the mode H. pylori infection in oral cavity and stomach. We recruited 100 subjects without systemic disease including gastrointestinal disease. Samples in oral cavity taken on gingival sulcus fluid(GSF) of lower left central incisor and 1st molar, area of buccal mucosa, dorsum of the tongue, palatal and saliva. We analyzed by Nested polymerase chain reaction(PCR) for oral infection and Urea Breath Test(UBT) for gastric infection. The results were as follows : 1. Among these 100 subjects, 36(36%) were positive by Nested PCR and 33(33%) were positive by UBT(p>0.05). 2. In detection rate of H. pylori in sites taken sample, 11(11%), 8(8%), 9(9%), 3(3%), 9(9%), 7(7%) were positive on GSF of lower left central incisor and 1st molar, area of buccal mucosa, dorsum of the tongue, palatal and saliva, respectively. Statical significance was observed in samples of GSF of lower left central incisor and area of dorsum of the tongue(p<0.05). 3. In comparison of the mode of H. pylori infection in oral cavity and stomach by analytic method, positive in oral cavity and stomach was 10(10%), negative in oral cavity and positive in stomach was 23(23%), positive in oral cavity and negative in stomach was 26(26%) and negative in oral cavity and stomach was 41(41%)(p>0.05). Conclusively, we can guess that oral H. pylori is not associated with gastric H. pylori infection and normal flora.

Viscosity and Wettability of Carboxymethylcellulose(CMC) solutions and Artificial Saliva (Carboxymethylcellulose(CMC) 용액과 인공 타액의 점도와 습윤성)

  • Park, Moon-Soo;Kim, Young-Jun
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 2007
  • Destruction of oral soft and hard tissues and resulting problems seriously affect the life quality of xerostomic patients. Although artificial saliva is the only regimen for xerostomic patients with totally abolished salivary glands, currently available artificial salivas give restricted satisfaction to patients. The purpose of this study was to contribute to the development of ideal artificial saliva through comparing viscosity and wettability between CMC solutions and human saliva. Commercially-available CMC is dissolved in simulated salivary buffer (SSB) and distilled deionized water (DDW). Various properties of human whole saliva, human glandular saliva, and a CMC-based saliva substitutes known as Salivart and Moi-Stir were compared with those of CMC solutions. Viscosity was measured with a cone-and-plate digital viscometer at six different shear rates, while wettability on acrylic resin and Co-Cr alloy was determined by the contact angle. The obtained results were as follows: 1. The viscosity of CMC solutions was proportional to CMC concentration, with 0.5% CMC solution displaying similar viscosity to stimulated whole saliva. Where as a decrease in contact angle was found with increasing CMC concentration. 2. The viscosity of human saliva was found to be inversely proportional to shear rate, a non-Newtonian (pseudoplastic) trait of biological fluids. The mean viscosity values at various shear rates increased as follows: stimulated parotid saliva, stimulated whole saliva, unstimulated whole saliva, stimulated submandibular-sublingual saliva. 3. Contact angles of human saliva on the tested solid phases were inversely correlated with viscosity, namely decreasing in the order stimulated parotid saliva, stimulated whole saliva, unstimulated whole saliva, stimulated submandibular-sublingual saliva. 4. Boiled CMC dissolved in SSB (CMC-SSB) had a lower viscosity than CMC-SSB (P < 0.01 at shear rate of $90s^{-1}$). 5. For human saliva, contact angles on acrylic resin were significantly lower than those on Co-Cr alloy (P < 0.01). 6. Comparing CMC solutions with human saliva, the contact angles between acrylic resin and human saliva solutions were significantly lower than those between acrylic resin and CMC solutions, including Salivart and Moi-Stir (P <0.01). The effectiveness of CMC solutions in terms of their rheological properties was objectively confirmed, indicating a vital role for CMC in the development of effective salivary substitutes.

A Pressure Adjustment Protocol for Programmable Valves

  • Kim, Kyoung-Hun;Yeo, In-Seoung;Yi, Jin-Seok;Lee, Hyung-Jin;Yang, Ji-Ho;Lee, Il-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.370-377
    • /
    • 2009
  • Objective : There is no definite adjustment protocol for patients shunted with programmable valves. Therefore, we attempted to find an appropriate method to adjust the valve, initial valve-opening pressure, adjustment scale, adjustment time interval, and final valve-opening pressure of a programmable valve. Methods : Seventy patients with hydrocephalus of various etiologies were shunted with programmable shunting devices (Micro Valve with $RICKHAM^{(R)}$ Reservoir). The most common initial diseases were subarachnoid hemorrhage (SAH) and head trauma. Sixty-six patients had a communicating type of hydrocephalus, and 4 had an obstructive type of hydrocephalus. Fifty-one patients had normal pressure-type hydrocephalus and 19 patients had high pressure-type hydrocephalus. We set the initial valve pressure to $10-30\;mmH_2O$, which is lower than the preoperative lumbar tapping pressure or the intraoperative ventricular tapping pressure, conducted brain computerized tomographic (CT) scans every 2 to 3 weeks, correlated results with clinical symptoms, and reset valve-opening pressures. Results : Initial valve-opening pressures varied from 30 to $180\;mmH_2O$ (mean, $102{\pm}27.5\;mmH_2O$). In high pressure-type hydrocephalus patients, we have set the initial valve-opening pressure from 100 to $180\;mmH_2O$. We decreased the valve-opening pressure $20-30\;mmH_2O$ at every 2- or 3-week interval, until hydrocephalus-related symptoms improved and the size of the ventricle was normalized. There were 154 adjustments in 81 operations (mean, 1.9 times). In 19 high pressure-type patients, final valve-opening pressures were $30-160\;mmH_2O$, and 16 (84%) patients' symptoms had nearly improved completely. However, in 51 normal pressure-type patients, only 31 (61%) had improved. Surprisingly, in 22 of the 31 normal pressure-type improved patients, final valve-opening pressures were $30\;mmH_2O$ (16 patients) and $40\;mmH_2O$ (6 patients). Furthermore, when final valve-opening pressures were adjusted to $30\;mmH_2O$, 14 patients symptom was improved just at the point. There were 18 (22%) major complications : 7 subdural hygroma, 6 shunt obstructions, and 5 shunt infections. Conclusion : In normal pressure-type hydrocephalus, most patients improved when the final valve-opening pressure was $30\;mmH_2O$. We suggest that all normal pressure-type hydrocephalus patients be shunted with programmable valves, and their initial valve-opening pressures set to $10-30\;mmH_2O$ below their preoperative cerebrospinal fluid (CSF) pressures. If final valve-opening pressures are lowered in 20 or $30\;mmH_2O$ scale at 2- or 3-week intervals, reaching a final pressure of $30\;mmH_2O$, we believe that there is a low risk of overdrainage syndromes.

Heating Performance of Hot Water Supplying System in Greenhouse (온수배관을 이용한 온실의 난방성능)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Kim, Hyeon-Tae;Bae, Seoung-Beom;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2012
  • This research was conducted to obtain basic data with regard to the heating performance that would be produced by installing an aluminum hot water pipe inside the greenhouse with the goal of reducing the heating energy in greenhouse. The research results are summarized as follows. The degree of difference in relation to the temperature by height within the greenhouse during the entire experiment was significant - within the range of 4.0~$7.0^{\circ}C$. The temperature difference between incoming and outgoing water was about $3.3^{\circ}C$ greater when FCU was activated compared to when it was not activated. Meanwhile, the amount of energy consumed increased about 36.2~40.1%. The amount of pyrexia per hour also increased by 44.6~52.0%. During the experiment period, circulated flux was within the range of 0.48~$0.49L{\cdot}s^{-1}$ while average fluid speed was 1.53~$1.56m{\cdot}s^{-1}$. The average temperature difference between incoming and outgoing water was 6.24~$11.50^{\circ}C$. The amount of heating value by each set temperature within the minimum outdoor temperature range of -14.0~$-0.6^{\circ}C$ was 135,930~307,150 kcal, and the range was within the 9,610~$19,630kcal{\cdot}h^{-1}$ per hour. This demonstrated that about 23~53% heating energy of the maximum heating load could be supplied. Total radiating value and amount of energy consumed were 2,548,306 kcal and 3,075.7 kWh, respectively. When heating takes place using oil, which is a fossil fuel, the total amount of light oil consumed was 281.6 L while the cost was 321,000 won. When the electricity cost for farms is applied, the total cost was about 110,730 won, which is about 33.5% of the cost required compared to oil consumption. The temperature at in the experiment area was about 8.3~$14.6^{\circ}C$ higher compared to that of the control area.

Simulation and Measurement of Signal Intensity for Various Tissues near Bone Interface in 2D and 3D Neurological MR Images (2차원과 3차원 신경계 자기공명영상에서 뼈 주위에 있는 여러 조직의 신호세기 계산 및 측정)

  • Yoo, Done-Sik
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.33-40
    • /
    • 1999
  • Purpose: To simulate and measure the signal intensity of various tissues near bone interface in 2D and 3D neurological MR images. Materials and Methods: In neurological proton density (PD) weighted images, every component in the head including cerebrospinal fluid (CSF), muscle and scalp, with the exception of bone, are visualised. It is possible to acquire images in 2D or 3D. A 2D fast spin-echo (FSE) sequence is chosen for the 2D acquisition and a 3D gradient-echo (GE) sequence is chosen for the 3D acquisition. To find out the signal intensities of CSF, muscle and fat (or scalp) for the 2D spin-echo(SE) and 3D gradient-echo (GE) imaging sequences, the theoretical signal intensities for 2D SE and 3D GE were calculated. For the 2D fast spin-echo (FSE) sequence, to produce the PD weighted image, long TR (4000 ms) and short TE$_{eff}$ (22 ms) were employed. For the 3D GE sequence, low flip angle (8$^{\circ}$) with short TR (35 ms) and short TE (3 ms) was used to produce the PD weighted contrast. Results: The 2D FSE sequence has CSF, muscle and scalp with superior image contrast and SNR of 39 - 57 while the 3D GE sequence has CSF, muscle and scalp with broadly similar image contrast and SNR of 26 - 33. SNR in the FSE image were better than those in the GE image and the skull edges appeared very clearly in the FSE image due to the edge enhancement effect in the FSE sequence. Furthermore, the contrast between CSF, muscle and scalp in the 2D FSE image was significantly better than in the 3D GE image, due to the strong signal intensities (or SNR) from CSF, muscle and scalp and enhanced edges of CSF. Conclusion: The signal intensity of various tissues near bone interface in neurological MR images has been simulated and measured. Both the simulation and imaging of the 2D SE and 3D GE sequences have CSF, fat and muscle with broadly similar image intensity and SNR's and have succeeded in getting all tissues about the same signal. However, in the 2D FSE sequence, image contrast between CSF, muscle and scalp was good and SNR was relatively high, imaging time was relatively short.

  • PDF

Pseudoradial Tear of the Medial Meniscus: A Relatively Common Potential Pitfall (내측반월상 연골의 가성방사파열: 비교적 흔한 진단상 함정)

  • You, Woo Young;Choi, Jung-Ah;Oh, Kyoung Jin;Min, Seon Jeong;Choi, Jae Jeong;Chang, Suk Ki;Hwang, Dae Hyun;Kang, Ik Won
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.219-224
    • /
    • 2014
  • Purpose : To determine the incidence of truncated triangle appearance of anterior horn (AH) to body of medial meniscus (MM) and determine its clinical significance. Materials and Methods: IRB approval was obtained, and informed consent waived for this study. The criteria of "pseudoradial tear" was truncated triangle appearance of the tip of AH to body of MM on one or more coronal images with adjacent fluid signal intensity at the blunted tip. Two musculoskeletal radiologists retrospectively evaluated 485 knee MR images independently for the presence and number of sections with "pseudoradial tear" of AH to body of MM using proton density-weighted coronal MR images. Inter-and intraobserver agreement was calculated using kappa coefficients. Medical records were reviewed for arthroscopic correlation. Results: A pseudoradial tear in the AH to body of MM was present in 381 (78.6%) patients. Locations were 112 in AH (29.4%), 143 in AH to body (37.5%), and 126 in body (33.1%). Number of consecutive sections of pseudoradial tear were 1 in 100 (26.2%), 2 in 164 (43.0%), 3 in 94 (24.7%), 4 in 21 (5.5%), and 5 in 2 (0.5%). Interobserver agreement was 0.99 for presence and 0.43 for number of sections of pseudoradial tear. Arthroscopies were performed in 96 patients and none of the pseudoradial tears were proven as true radial tears on arthroscopy. Conclusion: Pseudoradial tears are frequently seen in AH to body of MM on coronal MR images and may be another pitfall that a radiologist needs to be aware of and be able to differentiate from true radial tear.

Characterization of Laccase Purified from Korean Pycnoporus cinnabarinus SCH-3 (한국산 주걱송편버섯(Pycnoporus cinnabarinus) SCH-3로부터 정제 된 Laccase의 특성)

  • Park, Eun-Hye;Yoon, Kyung-Ha
    • The Korean Journal of Mycology
    • /
    • v.31 no.2
    • /
    • pp.59-66
    • /
    • 2003
  • Laccase produced by Pycnoporus cinnabarinus SCH-3 isolated from Korea was partially purified using ultrafiltration, anion exchange chromatography and affinity chromatography, The laccase was produced as the predominant extracellular phenoloxidase during primary metabolism. Neither lignin peroxidase nor manganese-dependent peroxidase were detected in the culture fluid. In order to examine the effect of inducers in laccase production, 2,5-xylidine was added in the culture of Pycnoporus cinnabarinus SCH-3. Addition of 2,5-xylidine enhanced 25-fold laccase production. Purified laccase was a single polypeptide having a molecular mass of approximately 66 kDa, as determined by SDS-polyacrylamide gel electrophoresis, and carbohydrate content of 9%. $K_{m}\;and\;V_{max}$ values for laccase with ABTS [2,2-azinobis (3-ethylbenzthiazoline 6-sulfonic acid)] as a substrate (Lineweaver-Burk plot) was determined to be $44.4{\mu}M\;and\;56.0{\mu}mole$, respectively. The optimal pH for laccase activity was found to be 3.0. The enzyme was very stable for 1 hour at $60{\circ}C$. Half-life ($t_{1/2}$) of the enzyme was about 10 min at $80{\circ}C$. Spectroscopic analysis of purified enzyme indicated that the enzyme was typical of copper-containing protein. Substrate specificity and inhibitor studies for laccase also indicated to be a typical fungal laccase. The N-terminal amino acid sequence of the P. cinnabarinus SCH-3 laccase showed 94% of homology to the N-terminal sequences of laccases from P. cinnabarinus PB and P. coccineus.

Mineralogy and Geochemistry of Quaternary Fault Gouges in the Southeastern Korean Peninsula (한반도 동남부 제4기 단층 비지의 광물학적 및 지구화학적 연구)

  • 손승완;장태우;김영규
    • Journal of the Mineralogical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.85-94
    • /
    • 2002
  • XRF, XRD, EPMA have been used to investigate microstructures and mineralogical changes caused by the faulting and fluids associated with faulting in the Quaternary fault gouge zones at the Sangchon, Ipsil and Wangsan faults located at the southeastern part of the Korean Peninsula. The chemical compositions of faulted rocks and protoliths analyzed by XRF show that the fault gouges are relatively enriched in TiO$_2$, P$_2$O$_{5}$, MgO, and Fe$_2$O$_3$) compared with protoliths, indicating that the fluids associated with faulting were highly activated. XRD results show that the fault gouges predominantly consist of quartz, feldspar, calcite and clay minerals. Clay minerals formed in the gouge zones are mainly composed of smectite characterized by a dioctahedral sheet. Based on EPMA analyses various kinds of sulfide, carbonate, phosphate minerals were identified in the gouge zones and protoliths. Xenotime of grey fault gouge of the Sangchon fault and sulfide minerals of contact andesitic rock of Ipsil fault and contact grey andesitic rock of Wangsan fault were probably formed by inflow of hydrothermal solution associated with faulting prior to the Quaternary. Carbonate minerals of contact andesitic rock and gouge zone of the Ipsil fault were formed by inflow of fluid associated with faulting prior to the Quaternary. They are heavily fractured and have reaction rim on their edge, indicating that faultings and inflow of fluids were highly activated after carbonate minerals were formed. Calcites of Wangsan fault seemed to be formed in syntectonic or posttectonic Quaternary faulting.g.

The risk factors and prognosis associated with neonatal pulmonary hemorrhage (신생아 폐출혈 발생에 영향을 미치는 위험 인자 및 예후에 관한 고찰)

  • Park, Su-Jin;Yun, Ki-Tae;Kim, Won-Duck;Lee, Sang-Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.4
    • /
    • pp.503-509
    • /
    • 2010
  • Purpose : Although neonatal pulmonary hemorrhage is rare, it is associated with high mortality. We aimed to evaluate the risk factors associated with pulmonary hemorrhage in preterm infants and to describe the clinical course, including neonatal morbidity, of infants who developed pulmonary hemorrhage. Methods : We performed a retrospective case-control study of 117 newborn infants aged less than 37 gestational weeks admitted to the neonatal intensive care unit of Daegu Fatima Hospital between January 1995 and December 2008. Control group infants without pulmonary hemorrhage were matched according to the gestational age, duration of mechanical ventilation, and birth weight range (${\leq}100g$). Pulmonary hemorrhage was defined as the presence of hemorrhagic fluid in the trachea and severe respiratory decompensation. Results : Pulmonary hemorrhage occurred in 17 cases of very low birth weight infants (VLBW; birth weight < 1,500 g; median age, 3 days) and 22 cases of low birth weight infants (LBW; $1,500g{\leq}$ birth weight < 2,500 g; median age, 1 day). Antenatal maternal glucocorticoid treatment significantly reduced the incidence of pulmonary hemorrhage in VLBW infants. Low APGAR score (${\leq}3$ at 1 min) and acidosis at birth were associated with significantly high incidence of pulmonary hemorrhage in LBW infants. Conclusion : Antecedent factors and timing of pulmonary hemorrhage of LBW infants were different from those of VLBW infants. The mortality rates of VLBW and LBW infants were 88.2% and 45.5%, respectively. Pulmonary hemorrhage was the principal cause of death in 66.6% VLBW infants and 40.0% LBW infants.

Characteristics of Micro-Particle Separation according to HRT Changes (HRT 변화에 따른 미세입자 분리 특성)

  • Ahn, Kwangho;Ahn, Jaehwan;Kim, I-Tae;Kim, Seoggu;Kang, Sungwon;Park, Eunzoo;Lee, Youngsup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.937-942
    • /
    • 2013
  • Fluid generated within the sonic or ultrasonic waves are reflected by the wall, while the opposite direction forming a predetermined sound wave to the acoustic standing wave is referred to. In this study, the frequency of 1.0 MHz and 2.0 MHz acoustic standing wave generation module is installed in a continuous particle separation device, the laminar flow of influent, taking into account the hydraulic retention time (HRT) in accordance with changes in particle separation characteristics investigated. Operation of a standing wave in the particle separation device about $1.3{\sim}2.8^{\circ}C$ temperature is increased, but did not significantly affect the formation of standing waves. During operation, the HRT 1 hr frequency 1.0 MHz 2 hr, 4 hr longer as the particle separation efficiency (turbidity) were 64.1%, 70.0%, 74.3% and, 2.0 MHz has 58.0%, respectively, depending on HRT, 61.8%, 70.7% in the respectively. That is, the same frequency, the HRT treatment efficiency is 10% or more, depending on differences in generation and, 1.0 MHz frequency, 2 hr, 2.0 MHz 4 hr at about 70% or more of the processing efficiency can be maintained. Frequency of 1.0 MHz and 2.0 MHz operation at the same time, as a result, HRT 1 hr, 2 hr, 4 hr particle separation efficiency of 63.8%, respectively, 70.6%, 77.6%, rather than the generation of standing waves appear continuous HRT is affecting a lot of particles to separate could know.