• 제목/요약/키워드: Fluent code

검색결과 389건 처리시간 0.024초

Experimental and Numerical Study on Slamming Impact

  • Kwon, Sun Hong;Yang, Young Jun;Lee, Hee Sung
    • 한국해양공학회지
    • /
    • 제27권1호
    • /
    • pp.1-8
    • /
    • 2013
  • This paper presents the results of experimental and numerical research on the slamming phenomenon. Two experimental techniques were proposed in this study. The traditional free drop tests were carried out. However, the free drop tests done in this study using an LM guide showed excellent repeatability, unlike those of other researchers. The coefficients of variation for the drop test done in this experiment were less than 0.1. The other experimental technique proposed in this study was a novel concept that used a pneumatic cylinder. The pneumatic cylinder could accelerate the specimen over a very short distance from the free surface. As a result, high rates of repeatability were achieved. In the numerical study, the development of in-house code and utilization of commercial code were carried out. The in-house code developed was based on the boundary element method. It is a potential code. This was mostly applied to the computation of the wedge entry problem. The commercial code utilized was FLUENT. Most of the previous slamming research was done under the assumption of a constant body velocity all through the impact process, which is not realistic at all. However, the interaction of a fluid and body were taken into account by employing a user-defined function in this study. The experimental and numerical results were compared. The in-house code based on BEM showed better agreement than that of the FLUENT computation when it cames to the wedge computation. However, the FLUENT proved that it could deal with a very complex geometry while BEM could not. The proposed experimental and numerical procedures were shown to be very promising tools for dealing with slamming problems.

상용 및 오픈소스 CFD 코드를 이용한 EFD-CFD 워크샵 Case 3 해석 (CFD Analysis of EFD-CFD Workshop Case 3 using Commercial and Open Source CFD codes)

  • 김종록
    • 한국항공우주학회지
    • /
    • 제45권3호
    • /
    • pp.241-251
    • /
    • 2017
  • EFD-CFD 워크샵 중 Case3인 RAE Wing A 형상에 대해 전산유체역학 해석을 수행하였다. 해석자로 3개의 상용 CFD 해석 코드(Star-CCM+, Fluent, CFX)와 오픈 소스 CFD 코드(SU2)를 사용하였다. 격자는 상용 격자 생성 코드인 Pointwise를 이용하여 격자의 수에 따라 4가지를 생성하였다. 마하수 0.4, 0.8에서 는 받음각 2도, 마하수 0.9에서 받음각 1도에서 해석하였다. coarse격자부터 fine 격자까지는 압력계수 곡선과 수직력 계수는 비슷한 결과를 보였으나 항력 계수에서는 차이가 있었다. Star-CCM+과 Fluent의 해석에서 차분법의 차수가 높을수록 충격파의 위치를 앞으로 예측하였다. 수렴에 다다르는 계산시간은 Fluent, Star-CCM+, CFX의 순으로 나타났고 SU2는 이에 비해 수렴하는데 많은 시간이 들었다.

오일러리언 접근법을 이용한 기류제트에 의한 가스-입자 2상 난류 유동특성 모델링 연구 (A Study on Numerical Modeling of Turbulent Gas-Particle Flows in a rectangular chamber Using Eulerian-Eulerian Method)

  • 김태국;민동호;윤경범;장희철
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.202-208
    • /
    • 2006
  • The purpose of this research is to model numerically the turbulent gas-particle flows in a rectangular chamber using Eulerian-Eulerian Method. A computer code using the ${\kappa}-{\varepsilon}-Ap$ two-phase turbulence model is developed for the numerical study. This code and the Eulerian multiphase model in FLUENT were used for the numerical simulations of the two-phase flow in a rectangular chamber. The numerical results calculated by the two different turbulent gas-particle codes have shown that the ${\kappa}-{\varepsilon}-Ap$ model results in a stronger diffusion of the flow momentum in the gas-particle turbulence interaction than the Eulerian multiphase model in FLUENT.

  • PDF

FLUENT 코드를 이용한 타 단면의 점성 유동 해석 (Viscous Flow Analysis for the Rudder Section Using FLUENT Code)

  • 부경태;한재문;송인행;신수철
    • 대한조선학회논문집
    • /
    • 제40권4호
    • /
    • pp.30-36
    • /
    • 2003
  • Lately, the cavitation and erosion phenomena in the rudder have been increased for high-speed container ships. However, cavitation is not prone to occur in model experiments because of low Reynolds number. In order to predict the cavitation phenomena, the - analysis of the viscous flow in the rudder gap is positively necessary In this study, numerical calculation was applied to the two-dimensional flow around the rudder gap using FLUENT code. The velocity and pressure field were numerically acquired and cavitation phenomena could be predicted. And the case that the round bar was installed in the rudder gap was analyzed. For reducing the acceleration force when fluid flow through the gap, modified rudder shape is proposed, It is shown that modified rudder shape restrain the pressure drop at the entrance of the gap highly both in the computational results and in the model experiment, and reduce the cavitation bubbles.

수직축 풍력터빈 블레이드의 공기역학적 특성 (Aerodynamic characteristics of a vertical axis wind turbine blade)

  • 신지영;손영석;차득근;이철균;황이철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권8호
    • /
    • pp.877-884
    • /
    • 2006
  • The objective of this study is to investigate the aerodynamic characteristics of a vertical axis wind turbine blade as the basic study of a design of a vertical axis wind turbine. The lift and drag coefficients of the various shape of the vortical axis wind turbine blades are analyzed and compared using the CFD code Fluent. To validate the numerical analysis, the predicted results of the Fluent are compared with those of the Xfoil code and the experimental results. We conclude that the program Fluent can be used to predict the aerodynamics of the wind turbine blade. By comparing the predicted results of the aerodynamic characteristics of the different shape of the blades, an appropriate shape of the blade is suggested to design the vortical axis wind turbine blade.

FLUENT 5.4 코드를 이용한 양방향 유동 튜브에 대한 유동해석 (Flow Analyses using FLUENT 5.4 Code for the Bi-directional Flow Tube)

  • 강경호;윤병조;백원필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.934-938
    • /
    • 2003
  • Flow analyses using FLUENT 5.4 code were performed to validate the application of the local bidirectional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the bi-directional flow tube which can be applied for the various experimental conditions. 2-dimensional axisymmetric steady state flow analyses have been performed. By calculating the differential pressure at both the front and the rear hole of the flow tube, K values were evaluated. The K values show good linearity regardless of the tube sizes and the Re numbers in both water and air flow. And system pressure and water subcooling didn’'t affect the K values. Under the elevated pressure of 80bar with 80K water subcooling, the K value indicates a similar trend with the case of 2bar with 80K water subcooling.

  • PDF

평균 양방향 튜브의 설계 최적화를 위한 FLUENT 코드해석 (FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube)

  • 강경호;윤병조;어동진;백원필
    • 한국유체기계학회 논문집
    • /
    • 제8권4호
    • /
    • pp.14-19
    • /
    • 2005
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the average bi-directional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the average bi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

평균 양방향 튜브의 설계 최적화를 위한 FLUENT코드해석 (FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube)

  • 강경호;윤병조;어동진;백원필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.180-186
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the averagebi-directional flow tube in case of water and air flow In this study, sensitivity studies have been performed to optimize the design features of the average hi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

  • PDF

재연소를 이용한 NOx 저감의 실험적 연구 및 FLUENT를 이용한 수치적 연구 (Experimental Study for NOx Reduction Using Reburning and Numerical Study with FLUENT)

  • 김재관;김학영;백승욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.1967-1972
    • /
    • 2008
  • Reburning is an efficient combustion technology to reduce nitrogen oxide by injecting hydro-carbon fuel to the downstream of the main combustion. In this paper LPG has been used not only as main fuel but also as reburn fuel and air was used as an oxidizer with 15kW swirl burner. Experimental studies have been done to evaluate effect of reburning for NOx reduction. Also to examine the effect of the amount of burnout air for complete combustion by reburn fuel on NOx reduction, test was conducted by reducing the amount of burnout air. Computational fluid dynamic (CFD) simulation was performed using the commercial CFD code FLUENT 6.3 to simulate experimental results and investigate the thermo-chemical characteristics. An evaluation of reaction models for swirl burner has been carried out for propane-air with two step finite-rate eddy-dissipation model in FLUENT.

  • PDF