• Title/Summary/Keyword: Fluent Model

Search Result 434, Processing Time 0.024 seconds

Parametric comparative study of Rocket Nozzle Convective Heat Transfer Coefficient Application of Combustion gas characteristic and Method of Analysis (해석방법 및 연소가스특성 적용에 따른 로켓 노즐 대류열전달계수의 매개변수적 비교 고찰)

  • Kim, Yonggu;Bae, Joochan;Kim, Jinok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.651-663
    • /
    • 2017
  • Experimental results of $30^{\circ}-15^{\circ}$ nozzles were compared with numerically calculated convective heat transfer coefficients using FLUENT, Boundary Layer Integration Method and Bartz predictions. Also, the convective heat transfer coefficients were calculated by using FLUENT and boundary layer integration method for NASA HIPPO nozzles according to the characteristics of combustion gas and the correlation between pressure and pressure was compared. Finally, thermal analysis of NASA HIPPO nozzle was performed to compare the ablation thickness and char depth according to the combustion gas characteristics.

  • PDF

A Study on the Spray Characteristics of Swirl Injectors Using ANSYS Fluent (ANSYS Fluent를 이용한 와류형 분사기의 분무특성 연구)

  • Yoon, Wonjae;Lee, Bom;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.22 no.4
    • /
    • pp.159-168
    • /
    • 2017
  • Numerical studies on the spray characteristics of closed-type and open-type swirl injectors were conducted using ANSYS Fluent. By changing injection pressures, discharge coefficient and spray angle were calculated using the Reynolds stress BSL turbulent model. The numerical results were compared with previous experimental data to examine their accuracy. For a closed-type swirl injector, spray angles matched well with experimental results and discharge coefficients showed approximately 8% differences. On the contrary, discharge coefficients of an open-type swirl injector were similar with experimental result but its spray angles presented around 15% differences. Though the numerical results were not perfectly consistent with experimental data, it is thought that they could be sufficiently used for analyzing spray characteristics, specially which is hard to be measured from experiments. Numerical simulation with different turbulent models was also performed to examine their effects on the numerical results.

Transient Heat Transfer and Structural Analyses for the Turbopump Turbine of a Liquid Rocket Engine (액체 로켓 터보 펌프 터빈의 천이 열전달 및 구조 해석)

  • Yoo, Jae-Han;Choi, Ji-Hoon;Lee, In;Han, Jae-Hung;Jeon, Seong-Min;Kim, Jin-Han
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.58-65
    • /
    • 2004
  • Thermal and structural finite element analyses were performed for the turbopump turbine bladed disk model with shroud of a liquid rocket engine. The only 1/80 part model was analyzed which consists of 3D eight node isoparametric solid elements. The applied loading history consists of a startup condition with a thermal spike and a steady state. Heat transfer coefficient on the blade was predicted using the commercial Navier-Stokes solver, Fluent. Transient thermal responses during startup and steady states were calculated using a 3D finite element code developed. Maximum stress and shroud tip displacement under the influence of centrifugal and thermal loading were also determined.

A Study on the Flow Characteristics and Noise Predictions around the Shroud Fan using the Aero-acoustic Noise Model (공력소음 모델을 이용한 슈라우드 팬 주위의 유동특성 및 소음예측에 관한 연구)

  • Mo, Jang-Oh;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.3
    • /
    • pp.19-25
    • /
    • 2009
  • InThe purpose of this work is to analyze the flow characteristics and aerodynamic noise generated from a shroud fan at a constant 2,100 rpm using LES and FW-H noise model provided in the commercial code, FLUENT. Velocity distributions around the shroud fan obtained by using FLUENT code show good agreement with experimental results. The sound pressure level is decreased by about 6 dB as the distance from the fan increases twice. The directivity at 1st BPF shows a tendency of increasing SPL toward the axis of rotation.

Prediction of Rotordynamic Coefficients for High-Performance-Pump Seal Using CFD Analysis (CFD를 사용한 고성능 펌프 실의 동특성 계수 예측)

  • Choe, Bok-Seong;Ha, Tae-Woong
    • Tribology and Lubricants
    • /
    • v.26 no.1
    • /
    • pp.37-43
    • /
    • 2010
  • Precise prediction of rotordynamic coefficients for annular type seal of turbomachinery is necessary for enhancing their vibrational stability and various prediction methods have been developed. As the seal passage is designed complicatedly, the analysis based on Bulk-flow concept which has been mainly used in predicting seal dynamics is limited. In order to improve the seal rotordynamic prediction, full Navier-Stokes Equations with turbulent model derived in the seal flow passage have to be solved. In this study, 3D CFD(Computational Fluid Dynamics) analysis has been performed for predicting rotordynamic coefficients of non-contact type annular plain seal using FLUENT. Comparing with the results of Bulk-flow model analysis, the result of 3D CFD analysis shows good agreement.

ANALYSIS OF THE MIXING BEHAVIOR OF THE HEATED WATER FROM THERMAL DIFFUSER

  • Seo Il Won;Jeon Tae Myoung;Son Eun Woo;Kwon Seok Jae
    • Water Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.1-15
    • /
    • 2005
  • The numerical model, FLUENT, was employed to investigate the effect of the heated water discharged from the diffuser of Boryung Power Plant. Temperature patterns of the thermal effluent discharged from two proposed types of the diffusers was evaluated for maximum flood and maximum ebb tide. The hydraulic model experiments were also performed in the reduced scale of 1/150 to verify the numerical simulation results. The buoyant jets discharged from the diffusers were found to be significantly affected by the ambient flows beyond the region where the effluent momentum was dissipated. Both the numerical and experimental results showed that the area of the excess isotherm for Type 1 diffuser was larger than that for Type 2 diffuser. Type 2 diffuser system was observed to be a more effective diffuser design than Type 1 diffuser system based on the temperature reduction and excess isotherm obtained from the numerical simulation in the ambient flows.

  • PDF

Prediction of Non-Contact-Type Seal Leakage Using CFD (CFD를 사용한 터보기계 비접촉식 실의 누설량 예측)

  • Ha Tae-Woong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.3 s.36
    • /
    • pp.14-21
    • /
    • 2006
  • Leakage reduction through annular type seals of turbomachinery is necessary for enhancing their efficiency and the precise prediction method of seal leakage is needed. The analysis based on Bulk-flow concept has been mainly used in predicting seal leakage. However, full Navier-Stokes Equations with turbulent model derived in the seal flow passage have to be solved for improving the prediction of seal leakage. FLUENT 6 which is commercial CFD(Computational Fluid Dynamics) code based on FVM(Finite Volume Method) and SIMPLE algorism has been used to analyze leakage of various non-contact-type seals in this presentation. Comparing with the results of Bulk-flow model analysis and experiment, the result of CFD analysis shows good agreement with that of existing theoretical analysis for the incompressible grooved seal and compressive plain and staggered seal. The CFD analysis also shows improvement on the leakage prediction of the incompressible plain seal and compressive see-through-type labyrinth seal.

Prediction of Annular Type Seal Leakage Using 3D CFD (3차원 CFD를 사용한 환상 실의 누설량 예측)

  • Seok, Hee-Soo;Ha, Tae-Woong
    • Tribology and Lubricants
    • /
    • v.25 no.3
    • /
    • pp.150-156
    • /
    • 2009
  • Precise leakage prediction for annular type seals of turbomachinery is necessary for enhancing their efficiency and various prediction methods have been developed. As the seal passage is designed intricately, the analysis based on Bulk-flow concept which has been mainly used in predicting seal leakage is limited. In order to improve the seal leakage prediction, full Navier-Stokes Equations with turbulent model derived in the seal flow passage have to be solved. In this study, 3D CFD (Computational Fluid Dynamics) analysis has been performed for predicting leakage of various non-contact type anular seals using FLUENT. Compared to the results by Bulk-flow model analysis, experiment, and 2D CFD analysis, the result of 3D CFD analysis shows improvement in predicting seal leakage, especially for the parallel grooved pump seal.

A Study on Internal Flow of Mixing Tank by CFD (CFD를 이용한 가향 탱크 내부 유동에 관한 연구)

  • Chung, Han-Joo;Cho, Sung-Eel;Yang, Jin-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.32 no.2
    • /
    • pp.63-69
    • /
    • 2010
  • In the chemical, mineral and electronics, mechanically stirred tanks are widely used for complex liquid mixing processes. The paper present results from a computational fluid dynamics (CFD) model for the mixing tank in casing process. We used CFD software, FLUENT(Fluent, Inc, Lebanon, NH, version 6.2). A species transport model was used to model the problem. The flow patterns in a mixing tank, 1.6 m in diameter and 2.0 m in height, were studied using CFD. Numerical analysis results show that improved mixing tank was reduced low speed flow region and turbulent region in internal flow of mixing tank.

Comparative Study of Commercial CFD Software Performance for Prediction of Reactor Internal Flow (원자로 내부유동 예측을 위한 상용 전산유체역학 소프트웨어 성능 비교 연구)

  • Lee, Gong Hee;Bang, Young Seok;Woo, Sweng Woong;Kim, Do Hyeong;Kang, Min Ku
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1175-1183
    • /
    • 2013
  • Even if some CFD software developers and its users think that a state-of-the-art CFD software can be used to reasonably solve at least single-phase nuclear reactor safety problems, there remain limitations and uncertainties in the calculation result. From a regulatory perspective, the Korea Institute of Nuclear Safety (KINS) is presently conducting the performance assessment of commercial CFD software for nuclear reactor safety problems. In this study, to examine the prediction performance of commercial CFD software with the porous model in the analysis of the scale-down APR (Advanced Power Reactor Plus) internal flow, a simulation was conducted with the on-board numerical models in ANSYS CFX R.14 and FLUENT R.14. It was concluded that depending on the CFD software, the internal flow distribution of the scale-down APR was locally somewhat different. Although there was a limitation in estimating the prediction performance of the commercial CFD software owing to the limited amount of measured data, CFX R.14 showed more reasonable prediction results in comparison with FLUENT R.14. Meanwhile, owing to the difference in discretization methodology, FLUENT R.14 required more computational memory than CFX R.14 for the same grid system. Therefore, the CFD software suitable to the available computational resource should be selected for massively parallel computations.