• Title/Summary/Keyword: Flue gas desulfurization

Search Result 97, Processing Time 0.023 seconds

Performance Enhancement of Flue Gas Desulfurization System with Structural Constraints in 500 MW Coal Fired Power Plants (구조적 제약조건을 갖는 500 MW 석탄화력발전소 탈황설비의 성능개선)

  • Kim, Jong-Sung;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.30-35
    • /
    • 2019
  • To meet both increasing social demand for reduction of fine dust and the strengthened air pollutant emission standards, this paper indicated performance enhancement of FGD with structural constraints in 500 MW coal fired thermal power plant's. Through modifying internal facilities for flue gases to make swirl in the absorption tower, it made turbulence and increased the efficiency of material transfer, the reaction area and time with the limestone slurry. Therefore, it could reduce dust and enhance the performance of collecting the SO2. As a result, desulfurization efficiency was improved from 91.61% to 98.43% and dust removal efficiency was improved from 77.4% to 87.08%. Emission density is 7.85 ppm of SO2 and 4.67 mg/㎥ of dust. This is a level that satisfies emission limit of 25 ppm of SO2 and 5 mg/㎥ of dust which are the air pollutant emission standards of 2023. The performance enhancement method of this study is expected to be effectively applied to other coal-fired power plants with similar constraints.

Variation of Liquid to Gas Ratio and Sulfur Oxide Emission Concentrations in Desulfurization Absorber with Coal-fired Thermal Power Plant Outputs (석탄화력 발전설비의 출력에 따른 탈황 흡수탑 액기비와 황산화물 배출농도 변화에 대한 연구)

  • Kim, Kee-Yeong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.39-47
    • /
    • 2018
  • In this research, when the output of the standard coal-fired thermal power plant operating continuously at the rated output of 500 MW is changed to operate at 300 to 500 MW, the amount of sulfur oxide produced and the amount of sulfur oxide in the absorption tower of desulfurization equipment and proposed an extra liquid to gas ratio improvement inversely proportional to the output. In order to calibrate the combustion efficiency at low power, the ratio of sulfur oxides relative to the amount of combustion gas is increased as the excess air ratio is increased. When the concentration of sulfur oxide at the inlet of the desulfurization absorber was changed from 300 to 500 ppm along with the output fluctuation. The liquid to gas ratio of limestone slurry and combustion gas was changed from 10.99 to 16.27. Therefore, if the concentration of sulfur oxides with output of 300 MW is x, The following correlation equation is recommended for the minimum required flow rate of slurry for the reduction of surplus energy due to the increase of the liquid weight at low load. $y1[m^3/sec]=0.11x+3.74$

  • PDF

Desirable pH of Slurry in the Desulfurization Absorber for a 200 MW Anthracite Power Plant (200 MW급 무연탄 발전용 탈황 흡수탑에서 적정 슬러리pH)

  • Choi, Hyun-Ho;Yoo, Hoseon
    • Plant Journal
    • /
    • v.16 no.1
    • /
    • pp.38-43
    • /
    • 2020
  • In this study, Seochon Thermal Power Plant No.1 for anthracite coal was tested to find the proper operation range of limestone slurry pH in the absorber tower which can be operated continuously in compliance with the Air Quality Preservation Act and Seocheon Thermal Power Division's internal regulation, sulfur dioxide average emission regulation. When operating the sulfur dioxide concentration [ppm] in the combustion gas flowing into the desulfurization absorption tower at 370, 400, 460 and 550 ppm while the main operating elements such as the flow rate of the combustion gas were fixed, the proper slurry pH Were 4.4, 4.5, 4.8 and 5.1, respectively. Therefore, it is recommended to operate with the correlation equation, RpH=0.004×Cin+2.93 derived using sulfur dioxide and the appropriate slurry pH.

Evaluation of SO2 Absorption Efficiency for Calcined Oyster Shell Slurry Using a Simulated Spray Type-flue Gas Desulfurization (FGD) System: A Comparative Study with Limestone Slurry (모사 Spray Type 배연탈황설비를 이용한 소성패각 슬러리의 SO2 흡수능 평가: 석회석과의 비교연구)

  • Kim, Seok-Hwi;Hong, Bum-Uh;Lee, Jin-Won;Cha, Wang-Seok;Kim, Kangjoo;Moon, Bo-Kyung
    • Economic and Environmental Geology
    • /
    • v.52 no.2
    • /
    • pp.119-128
    • /
    • 2019
  • About 300,000 tones of oyster shell are annually produced in Korea and, thus, a massive recycling plan is required. Many desulfurizing studies using oyster shells with chemical composition of $CaCO_3$ have been performed so far; however, most of them have focused on dry desulfurization. This study investigates the possibility of using oyster shells for wet desulfurization after calcination. For this, a simulated wet desulfurization facility of spray type was devised and compared the SOx-stripping characteristics of calcined oyster shell with those of limestone. The calcined oyster shell slurry indicate a better desulfurizability than the slurries of raw shell or limestone because the oyster shell transformed to a more reactive phase ($Ca(OH)_2$) by the calcination and hydration. Because of this reason, when the calcined oyster shell slurries were used, the reaction residue showed the higher gypsum ($CaSO_4{\cdot}2H_2O$) contents than any other cases. In the continuous desulfurization experiments, calcined oyster shell slurry showed a wider pH variation than limestone or raw oyster shell slurries, another clear indication of high reactivity of calcined oyster shells for $SO_2$ absorption. Our study also shows that the efficiency of wet desulfurization can be improved by the use of calcined oyster shells.

Model Development of Spray Dryer Absorber FGD Process (Spray Dryer Absorber 배연탈황공정의 모델 개발)

  • Jang, Sun-Hee;Oh, Eui-Kyung;Lee, Hyung-Keun;Kim, Sun-Geon
    • Clean Technology
    • /
    • v.2 no.1
    • /
    • pp.80-95
    • /
    • 1996
  • A mathematical model has been developed for simulating the spray dryer absorber (SDA) used in semi-dry flue gas desulfurization process. Fundamental equations include the component mass and heat balances in both gas and droplet phases and the equation of motion for a single droplet. The model developed described the pilot-plant data much better than the existing SPRAYMOD-M model. The effect of the process variables, whose values were chosen within the operation limits of the actual pilot plants, on % $SO_2$ removal or conversion of the sorbent were calculated, and discussed in terms of $SO_2$ absorption rate, the residence time of flue gas, the velocity and drying time of droplets. Finally, the % $SO_2$ removal was calculated with two independent process variables and the results were shown on three-dimensional or two-dimensional diagrams with the lines of constant % $SO_2$ removal, so that they can be easily applied to preliminary design of the SDA.

  • PDF

Estimation of Washing Duration of Desulfurized Absorber in a Heavy Oil Power Plant (중유화력발전소 탈황 흡수탑 세정시기예측)

  • Jang, Yeong Gi;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.24-28
    • /
    • 2016
  • In desulfurization facilities of oil-fired power plant, gypsum scale is attached in the absorber inner surface as the operating time increases. For this reason, the maximum possible load of the power generation is set down, resulting in further generation stop. Cleaning of absorber for scale removal can be determined at the time of setting down of the maximum possible load. In this study, 6 weeks before the maximum possible load of the power generation was down set, at the same time and desulfurization facilities outlet $SO_2$ concentration value was more than 130ppm, absorber differential pressure exceeded $380mmH_2O$, it was confirmed to be the time that has elapsed 44 weeks after the previous absorber cleaning. Cleaning time of the absorber was predicted to be a time which has elapsed 50 weeks from the previous cleaning time.

  • PDF

SO$_2$ and NOx Reaction Characteristics of Waste Clam Sorbent in Fixed Bed Reactor

  • Jung, Jong-Hyeon;Shon, Byung-Hyun;Yoo, Kyung-Sun;Kim, Hyun-Gyu;Lee, Gang-Woo;Kim, Young-Sik
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.152-156
    • /
    • 2003
  • Air pollution problems due to the emission of pollutants from the various industrial facilities become serious issues and lots of air pollution control processes have been developed. To remove the SO$_2$ and NOx emitted from the solid waste incinerator and coal fired power plants, we studied the Ca-based sorbent which was prepared by waste clam and limestone. The objectives of this study were to develop a clam-based sorbent for removal of SO$_2$ and NOx, and to investigate the physicochemical properties of the waste clam sorbent. In order to determine acid gas removal capacity of sorbent, the batch study on SO$_2$ and NOx removal was performed with the Ca-based sorbent in the fixed bed reactor. Results of the research revealed that clam-based sorbent can be used as the iron-manufacturing industry and chemical adsorbents for the removal of acid gases because the lime content of the waste calm was more than 53.92%. From physicochemical analysis and gas reaction experiments, it could be concluded that clam is good sorbent for the removal of SO$_2$ and NOx in waste incinerator and flue gas desulfurization processes.

  • PDF

Flue Gas Desulfurization System For Reducing SOx Emission In Thermal Power Plant (황산화물 저감을 위한 배연탈황설비 설치 사례)

  • 조승원;황영호;전상기
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.451-452
    • /
    • 1999
  • 석탄이나 석유와 같은 화석연료의 연소 시 대기 중에 발생되는 황산화물의 배출저감 방법으로서 사용연료의 황 함유량을 감소시키는 연소 전 처리방법과 연소과정 중 제거방법, 연소 후 제거하는 방법으로 구분할 수 있다. 본 논문에서는 전기 생산능력 40만 kW 급 중유화력 발전소의 연료 연소 후 배기가스 중 황 성분을 제거하는 방법으로 석회석 슬러리와 배기가스를 효과적으로 접촉시켜 SOx 와 먼지 등의 환경오염물질을 제거하고 부산물로 재활용 가능한 고순도의 석고를 생산하게 되는 JBR (Jet Bubbling Reactor) 형식의 습식 석회석-석고법 배연탈황 시스템을 소개하고자 한다.(중략)

  • PDF

Reliability Evaluation of a Slurry Pump (슬러리 펌프의 신뢰성 향상)

  • Jung, Dong Soo
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.263-271
    • /
    • 2016
  • Purpose: A slurry pump for flue gas desulfurization system performs a role that discharges the slurry of a plaster shape in a thermal power plant. Since a slurry pump transfers the slurry by the centrifugal force, it has the friction wear in the impeller and liner because of the slurry. Methods: In this study, failure analysis and test evaluation on the slurry pump have been proposed and the process that reliability of the product improves through design improvement has been presented. And failure cause of typical failure case has been investigated and improvement design has been presented. Results: Reliability improvement is established by analysis of the test results of before and after acceleration test. Conclusion: This study can be provided to improve the product reliability through failure analysis of a slurry pump.

Flow Analysis of the Wet Flue Gas Desulfurization System for 800MW Power Plant (800MW 습식배연탈황설비 홉수탑 유동특성 해석)

  • 정석용;김중석;문길호;김성원;이호경
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.467-468
    • /
    • 2003
  • 국내 최초 800MW급 석탄화력발전소로서 국제환경 규제 기준치를 능가하는 최첨단 환경 설비를 모두 갖춘 최신 발전소로 건설되고 있는 한국남동발전(주) 영흥화력 1,2호기가 2004년 7월과 12월에 완공을 목표로 보일러 및 습식배연탈항설비의 공사가 진행되고 있다. 이에 당사는 본 공사의 주계약자로서 국내 최대 규모의 최첨단 발전소 건설을 위해 최선의 노력을 경주하고 있다. 영흥화력 1,2호기 습식배연탈황설비는 800MW 2호기로 구성되어 있으며 용량 및 시스템 배열 면에 있어서 기존의 설비들과는 상이하므로 시스템 성능 예측 및 평가와 그에 파생되는 설계개선을 위한 새로운 접근방법이 필요하다. (중략)

  • PDF