충돌제트의 유량분포 및 혼합특성에 관한 실험적 연구 (An experimental study on flow distribution and mixing in impinging jets)

  • 이충훈;정영호;정석호
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.99-112
    • /
    • 1997
  • Mixing process of impinging jets of liquid oxidizer and liquid fuel is simulated by using water and sodium carbonate (Na$_{2}$CO$_{3}$) solution. The shapes of liquid sheets are visualized and flowrate distributions are measured by collecting droplets using measuring cells. Mixing charateristics are studied by using acid-base titration. Stable liquid sheets are formed and two liquid jets are well mixed for symmetric impinging jets. Similarity in flowrate distribution for various measuring heights is observed. For asymmetric impinging jets, liquid sheets become unstable as the difference in the velocities of jets increases. In some extreme cases, liquid sheets are not formed and the jets are separated. Dimensionless variables are adopted demonstrating similarly in flowrate distribution. Mixing characteristics vary significantly with experiment conditions.

소수력발전소의 출력특성 분석 (Output Characteristic Analysis of Small Hydropower Plant)

  • 박완순;이철형
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.81-85
    • /
    • 2006
  • The output performance characteristics for surveyed sites were analyzed, using developed model. It consists of two main parts, the deciding flow duration characteristic of river and performance prediction model to estimate the output characteristics of small hydropower plants. As a result, It was found that the flowrate concerning with 25% of time ratio on flow duration curve can be selected to design flowrate of small hydropower plants, and the output characteristics of small hydropower plants having overflow dam are different from large scale hydropower plants.

  • PDF

프란시스수차의 수력학적 성능특성 분석 (Hydraulic Performance Analysis of Francis Type Turbine)

  • 이철형;박완순
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.664-667
    • /
    • 2009
  • The Francis type hydro turbine with vertical axis has been designed and analized for hydraulic performance verification. The guide vane angle of turbine casing were designed to be varied according to the condition of head and flowrate. When the changes in flowrate and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed hydro turbine in this study will be suitable for small hydro power stations with medium and high head such as agricultural reservoirs and large dam.

  • PDF

프란시스수차의 국산화개발 연구 (R&D of Francis Type Hydro Turbine for Domestic Production)

  • 이철형;박완순
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.302-305
    • /
    • 2009
  • The Francis type hydro turbine with vertical axis has been designed and analized for hydraulic performance verification. The guide vane angle of turbine casing were designed to be varied according to the condition of head and flowrate. When the changes in flowrate and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed hydro turbine in this study will be suitable for small hydro power stations with medium and high head such as agricultural reservoirs and large dam.

  • PDF

소수력발전입지의 수계별 설계변수 특성(I) (Design Parameters of Small Hydro Power Sites for River Systems(I))

  • 박완순;이철형
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.86-91
    • /
    • 2010
  • The characteristics of hydrologic design parameters for small hydro power(SHP) sites located in four major river systems have been studied. The model, which can predict flow duration characteristic of stream, was developed to analyze the variation of inflow. And another model to predict hydrologic performance for SHP plants is established. The results from hydrologic performance analysis for SHP sites located on five major river systems based on the models developed in this study show that the specific design flowrate and specific output of SHP site have large difference between the river systems. The load factor, however, have small difference compared with specific design flowrate and specific output for all river systems. Also, it was found that the models developed in this study can be used to predict the primary design specifications of SSHP plants effectively.

프란시스수차의 국산화 실증 연구 (Performance Verification of Francis Type Hydro Turbine for Domestic Production)

  • 이철형;박완순
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.167-171
    • /
    • 2008
  • The Francis type hydro turbine with vertical axis has been designed and analized for hydraulic performance verification. The guide vane angle of turbine casing were designed to be varied according to the condition of head and flowrate. When the changes in flowrate and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed hydro turbine in this study will be suitable for small hydro power stations with medium and high head such as agricultural reservoirs and large dam.

  • PDF

냉매충전량이 모세관 팽창장치를 가진 공기조화기의 성능에 미치는 영향 (The Effects of the Refrigerant Charge on the Performance of an Air Conditioner with Capillary Tube Expansions)

  • 최은수;김종배
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.359-364
    • /
    • 2002
  • A popular type of residential air conditioner is the split system which has two separate units: indoor and outdoor units During field installation of the split system, the potential exists for not setting the charge exactly to the manufacturer´s specifications. The objective of this study is to investigate the effects of the refrigerant charge on the performance of the air conditioner. An air conditioner with capillary tube expansions was tested for various refrigerant charges. The results indicated that the more charge resulted in the more flowrate of the refrigerant. The flowrate of the refrigerant was one of the most important factors to understand the e(sects of the charge on the performance of the air conditioner with capillary tube expansions. Under-charge results in wide region of superheated vapor of the refrigerant in the evaporator, while over-charge results in high temperature of the liquid refrigerant in the evaporator.

Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger

  • Kim, Byung-Jo;Choi, Young-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권2호
    • /
    • pp.61-70
    • /
    • 2005
  • This study treats the numerical analysis of performance and design for plume abatement wet/dry cooling tower with a dry type heat exchanger. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. The Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parametric simulations such as the relative flowrate of air and attachment length of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of cooling capacity and the additional cost are reduced and the plume is abated.

하수관거 유량자료의 보정방법에 관한 연구 (A Study on the Modification Method of Flow Data in the Sewage System)

  • 김대근;공민근
    • 상하수도학회지
    • /
    • 제17권4호
    • /
    • pp.495-502
    • /
    • 2003
  • In order to modify incorrect flow data in the sewage system, the method using the stage-discharge relation and hydraulic characteristic curve of sewer pipe are applied. The modified data were verified with field measured data and the infiltration analysis using the modified data was carried out. When flowrate were measured using the flow-meter in fair weather, the stage data were comparatively consistent but velocity data were very poor for the most part. Therefore, it was recommended that sewage flowrate variation characteristic curve and infiltration were computed using the modified data on the basis of stage data. Especially, in the case of using the hydraulic characteristic curve, extrapolation results of the rainy season flowrate using regression curve on the basis of the data in fair weather were also reasonable.

AN ANALYSIS OF PERFORMANCE CHARACTERISTICS FOR SMALL HYDRO POWER PLANTS

  • Park, Wan-Soon;Lee, Chul-Hyung;Jeong, Sang-Man
    • Water Engineering Research
    • /
    • 제2권1호
    • /
    • pp.11-19
    • /
    • 2001
  • A performance prediction model for Small Hydro Power(SHP) sites has been studied and developed. Twelve SHP sites were selected and the performance characteristics were analyzed by using the developed model. Also, primary design specifications such as design flowrate, plant capacity, operational rate were suggested and feasibility for small hydro power sites were estimated. It was found that the design flowrate is most important parameter to exploit SHP plant and the methodology developed in this study can be a useful tool to analyze the performance of SHP sites.

  • PDF