• Title/Summary/Keyword: Flow-rate Coefficient

Search Result 933, Processing Time 0.026 seconds

Assessing Groundwater Vulnerability Using DRASTIC Method and Groundwater Quality in Changwon City (DRASTIC과 지하수 수질에 의한 창원시 지하수 오염취약성 평가)

  • Hamm Se-Yeong;Cheong Jae-Yeol;Kim Moo-Jin;Kim In-Soo;Hwang Han-Seok
    • Economic and Environmental Geology
    • /
    • v.37 no.6 s.169
    • /
    • pp.631-645
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in industrial and residential/commercial areas of the city of Changwon, using DRASTIC technique and groundwater data. The DRASTIC technique was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. Mostly the industrial area has higher DRASTIC indices than the residential/commercial area. However, a part of the residential/commercial area having much groundwater production and great drawdown is more contaminated in groundwater than other industrial and the residential/commercial areas even if it has lowest DRASTIC indices in the study area. It indicates that groundwater contamination in urban areas can be closely related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is as low as 0.40. On the other hand, the correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well distribution density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other human-made factors such as groundwater withdrawal rate and well distribution density per unit area as well as the existing seven DRASTIC factors.

Simultaneous Determination of Triterpenoid Saponins from Pulsatilla koreana using High Performance Liquid Chromatography Coupled with a Charged Aerosol Detector (HPLC-CAD)

  • Yeom, Hye-Sun;Suh, Joon-Hyuk;Youm, Jeong-Rok;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1159-1164
    • /
    • 2010
  • Several triterpenoid saponins from root of Pulsatilla koreana Nakai (Ranunculaceae) were studied and their biological activities were reported. It is difficult to analyze triterpenoid saponins using HPLC-UV due to the lack of chromophores. So, evaporative light scattering detection (ELSD) is used as a valuable alternative to UV detection. More recently, a charged aerosol detection (CAD) has been developed to improve the sensitivity and reproducibility of ELSD. In this study, we developed and validated a novel method of high performance liquid chromatography coupled with a charged aerosol detector for the simultaneous determination of four triterpenoid saponins: pulsatilloside E, pulsatilla saponin H, anemoside B4 and cussosaponin C. Analytes were separated by the Supelco Ascentis$^{(R)}$ Express C18 column (4.6 mm ${\times}$ 150 mm, 2.7 ${\mu}m$) with gradient elution of methanol and water at a flow rate of 0.8 mL/min at $30^{\circ}C$. We examined various factors that could affect the sensitivity of the detectors, including various concentrations of additives, the pH of the mobile phase, and the CAD range. Linear calibration curves were obtained within the concentration ranges of 2 - 200 ${\mu}g$/mL for pulsatilloside E, anemoside $B_4$ and cussosaponin C, and 5 - 500 ${\mu}g$/mL for pulsatilla saponin H with correlation coefficient ($R^2$) greater than 0.995. The limit of detection (LOD) and quantification (LOQ) were 0.04 - 0.2 and 2 - 5 ${\mu}g$/mL, respectively. The validity of the developed HPLC-CAD method was confirmed by satisfactory values of linearity, intra- and inter-day accuracy and precision. This method could be successfully applied to quality evaluation, quality control and monitoring of Pulsatilla koreana.

Thermal and Mechanical Properties of a N2 Doped Porous 3C-SiC Thin Film (질소가 도핑된 다공질 3C-SiC 박막의 열적, 기계적 특성)

  • Kim, Kang-San;Chung, Gwiy-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.8
    • /
    • pp.651-654
    • /
    • 2010
  • This paper describes the thermal and mechanical properties of doped thin film 3C-SiC and porous 3C-SiC. In this work, the in-situ doped thin film 3C-SiC was deposited by using atmospheric pressure chemical vapor deposition (APCVD) method at $120^{\circ}C$ using single-precursor hexamethyildisilane: $Si_2(CH_3)_6$ (HMDS) as Si and C precursors. 0~40 sccm $N_2$ gas was used as doping source. After growing of doped thin film 3C-SiC, porous structure was achieved by anodization process with 380 nm UV-LED. Anodization time and current density were fixed at 60 sec and 7.1 mA/$cm^2$, respectively. The thermal and mechanical properties of the $N_2$ doped porous 3C-SiC was measured by temperature coefficient of resistance (TCR) and nano-indentation, respectively. In the case of 0 sccm, the variations of TCR of thin film and porous 3C-SiC are similar, but TCR conversely changed with increase of $N_2$ flow rate. Maximum young's modulus and hardness of porous 3C-SiC films were measured to be 276 GPa and 32 Gpa at 0 sccm $N_2$, respectively.

Development Cut-off Value for Yin-deficiency Questionnaire and Diagnostic Ability of Yin-deficiency in Xerostomia (구강건조증 환자에서 음허 측정 설문지 절단점 개발 및 진단능 평가)

  • Jang, Seung-Won;Kim, Jin-Sung
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.483-497
    • /
    • 2014
  • Objectives: The aims of study were developing cut-off value of Yin-deficiency questionnaire (YDQ) for diagnosis of Yin-deficiency (YD) and compare diagnostic ability between YDQ and Yin-deficiency scale score (YDS) in xerostomia patients. Methods: We recruited 58 xerostomia patients. They were diagnosed YD or non-YD by 3 Korean medicine doctors (KMD). We assessed YD using YDQ and YDS. We evaluated xerostomia using VAS, Dry Mouth Symptom Questionnaire (DMSQ), Salivary Flow Rate (SFR), oral moisture on buccal mucosa and tongue surface (OMB and OMT). We surveyed tongue coatings using Winkel Tongue Coating Index (WTCI). Results: We diagnosed 23 patients YD and 35 patients non-YD. There were no significant differences of age, sex and body mass index between the YD and non-YD groups. Using receiver operating characteristic curve analysis, the optimal cut-off value of YDQ was defined as 304. Sensitivity, specificity and Youden index of YDQ were 86.96%, 71.43% and 1.5839 respectively. Using Cohen's coefficient of agreement, we found that degree of agreement between KMD and YDQ diagnosis was moderate (${\kappa}$=0.524, p<0.001). Using Pearson's correlation analysis, we found concurrent validity of YDQ and YDS were significant correlated. Using area under curve value, we found diagnostic ability between YDQ and YDS were not significantly different (p=0.505), but there were more strong correlations between DMSQ-symptoms and YDQ (r=0.731, p<0.001) than correlations between DMSQ-symptoms and YDS (r=0.418, p<0.01). Conclusions: The cut-off value of YDQ can diagnose YD in xerostomia and diagnostic ability of YDQ in xerostomia is better than YDS.

Study on the performance improvement of a Main Oxidizer shut-off Valve (CC 산화제 개폐밸브 성능향상에 관한 연구)

  • Bae, Young-Woo;Kim, Do-Hyung;Hong, Moon-Geun;Lee, Soo-Yong;Jang, Ki-Won
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.63-72
    • /
    • 2010
  • MOV(Main Oxidizer shut-off Valves) control the combustion of launch vehicle systems by the supply and the isolation of liquid oxygen to a main combustion chamber in launch vehicle systems. Moreover, the MOV should secure a constant flow rate of liquid oxygen for combustion instability in the steady operational state. Although it has been showed that a EM(Engineering Model) with a high discharge coefficient value compared with the TM(Technology Model) fills the overall performance requirements, additional design modifications in some critical parts of the EM were conducted to improve the performance. The configurations of the pressure-control body, the middle flange, and the rips of the inlet body of the EM were modified and the performance tests have been performed with test models. Consequently, the intended improvements have been verified by the performance tests.

Characteristics of conductive rubber belt on the abdomen to monitor respiration (호흡 감지를 위한 복부 부착형 전도성 고무소자의 계측특성)

  • Kim, Kyung-Ah;Kim, Sung-Sik;Cho, Dong-Wook;Lee, Seung-Jik;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.24-32
    • /
    • 2007
  • Conductive rubber material was molded in a belt shape to measure respiration. Its resistivity was approximately $0.03{\;}{\Omega}m$ and the resistance-displacement relationship showed a negative exponent. The temperature coefficient was approximately $0.006{\;}k{\Omega}/^{\circ}C$ negligible when practically applied on the abdomen. The conductive rubber belt was applied on a normal male's abdomen with the dimensional change measured during resting breathing. The abdominal signal was differentiated ($F_{m}$) and compared with the accurate standard air flow rate signal ($F_{s}$) obtained by pneumotachometry. $F_{m}$ and $F_{s}$ differed in waveform, but the start and end timings of each breaths were clearly synchronized, demonstrating that the respiratory frequency could be accurately estimated before further processing of $F_{m}$. $F_{m}-F_{s}$ loop showed a nonlinear hysteresis within each breath period, thus 6 piecewise linear approximation was performed, leading to a mean relative error of 14 %. This error level was relatively large for clinical application, though customized calibration seemed feasible for monitoring general variation of ventilation. The present technique would be of convenient and practical application as a new wearable respiratory transducer.

Quantitative Determination and Antioxidant Effects of Cheonwangbosimdan (LC-MS/MS를 이용한 천왕보심단(天王補心丹)의 함량분석 및 항산화 효능 연구)

  • Seo, Chang-Seob;Kim, Ohn Soon;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.45 no.4
    • /
    • pp.300-314
    • /
    • 2014
  • An ultra-performance liquid chromatography-electrospray ionization-mass spectrometer (UPLC-ESI-MS) method was established for the simultaneous quantification of eighteen marker compounds in traditional Korean formula, Cheonwangbosimdan (CWBSD). In addition, we evaluated the antioxidant effects of CWBSD. Eighteen marker components were separated on a UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}m$) and kept at $45^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as mobile phase. The flow rate was 0.3 mL/min and the injection volume was $2.0{\mu}L$. The antioxidant activities of CWBSD were assessed by measuring free radical scavenging activities on 2,2'-azinobis-3-ethylbenzothiazoline-6-sulfonic acid (ABTS) and 1-1-diphenyl-2-picrylhydrazyl (DPPH). The calibration curves of all analytes showed good linearity (correlation coefficient ${\geq}0.9937$) within the test ranges. The limits of detection and quantification for the 18 marker compounds were 0.01-4.71 ng/mL and 0.03-14.13 ng/mL, respectively. The contents of the 18 compounds in CWBSD extract ranged from none to $1701.00{\mu}g/g$. The CWBSD showed the radical scavenging activity in a dose-dependent manner. The concentration required for 50% reduction ($RC_{50}$) against ABTS and DPPH radicals were $149.42{\mu}g/mL$ and $339.24{\mu}g/mL$.

Quantitative Analysis of the Fifteen Constituents in Hyangso-San by LC-MS/MS (LC-MS/MS를 이용한 향소산 중 15종 성분의 정량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.4
    • /
    • pp.381-388
    • /
    • 2016
  • Hyangso-san is a traditional herbal medicine that consists of the seven herbal medicines, Cyperi Rhizoma, Perillae Folium, Atractylodis Rhizoma, Citri Unshius Pericarpium, Glycyrrhizae Radix et Rhizoma, Zingiberis Rhizoma Crudus, and Allii Fistulosi Bulbus. Hyangso-san has long been clinically used to treat the influenza, including headache, ferver, chills, and pantalgia. In this study, we were performed the simultaneous analysis of the 15 marker compounds (liquiritin apioside, liquiritin, ferulic acid, naringin, hesperidin, rosmarinic acid, liquiritigenin, kaempferol, glycyrrhizin, nobiletin, 6-gingerol, elemicin, atractylenolide III, nootkatone, and atractylenolide I) in Hyangso-san using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS). Column for the separation of the 15 ingredients was used a Waters Acquity UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}m$) at $45^{\circ}C$ by using a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile with gradient condition. Identifications of all analytes were performed using a Waters ACQUITY TQD LC-MS/MS system. The flow rate and injection volume were 0.3 mL/min and $2.0{\mu}L$, respectively. Correlation coefficient of the calibration curve was ${\geq}0.9958$. The values of limits of detection and quantification of the 15 components were 0.002-4.29 and 0.01-12.88 ng/mL, respectively. The result of an analysis using the established LC-MS/MS method, kaempferol and atractylenolide I were not detected, while other 13 compounds were 0.08-56.87 mg/g in lyophilized Hyangso-san sample.

Runoff Characteristics of Heavy Metals from a Parking Lot by Rainfall (주차장 지역의 강우에 의한 Pb와 Zn의 유출 특성)

  • Im, Jong-Kwon;Son, Hyun-Seok;Kim, Sung-Keun;Zoh, Kyung-Duk
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.926-933
    • /
    • 2010
  • Runoff from a parking lot can be highly contaminated nonpoint source due to the impermeability of rainwater. This study presented runoff characteristics of heavy metals especially Zn and Pb from a parking lot during total 17 rain events. Monitoring results showed the first flush phenomenon within 30 min was observed in all rain events, but the event mean concentration (EMC) did not clearly show the characteristics of runoff. The ranges of Pb and Zn was $4{\sim}201{\mu}g/L$ and $131{\sim}672{\mu}g/L$, respectively, and the runoff mass of Zn and Pb was highly to related with the flow rate, and runoff coefficient of rain. The runoff mass of Zn was greater than that of Pb in all events. The runoff mass of Pb was highly correlated with the amount of TSS, and TSS and DOC were was related with the mass of Zn. This result implies that Pb and Zn are mainly existed in the particulate form. The results can be used to as meaningful data in the management of nonpoint source, and in the management in the runoff catchment in the parking lot.

Intercomparison of vacuum standards of Korea, United Kingdom, and Japan (진공표준의 국제비교 연구)

  • 홍승수;신용현;임종연;이상균;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.308-313
    • /
    • 1997
  • TDS (Thermal Lkso~ption Spectroscopy)system, for diagnosis of CRT manufacturing process, was designed and constructed. Outgassings and themla1 desorptions from the part or materials of CRT can be measured and analysed with this system at various temperatures. The system is consisted of 3 pirrts. vacuum chamher and pumping system with variable conductance, sample heating stages & their controller, and outgassing measurement devices, like as ion gauge or quadrupole mass spectrometer. The ultimate pressure of the system was under $1\times10^{-7}$ Pa. With the variable conductance system, the effective pumping speed of the chamber could he controlled from sub 11s to 100 11s. The effective pumping speed values were determined by dynamic flow measurement principle. The temperatures and ramp rate of sample were controlled by tungsten heater and PID controller up to $600^{\circ}C$ within t $\pm 1^{\circ}C$$difference to setting value. Ion gauge & QMS were calibrated for quantitative measurements. Some examples of TDS measurement data ;ind application on the CRT process analysis were shown.

  • PDF