• Title/Summary/Keyword: Flow-rate Coefficient

Search Result 933, Processing Time 0.029 seconds

Dynamic characteristics of the compressor-combined condenser system (압축기 계가 결합된 응축기의 동특성)

  • Kim, Jae-Dol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.7
    • /
    • pp.1001-1012
    • /
    • 1998
  • This paper reports the analysis of dynamic characteristics of air-cooled condenser. At first, there is an assumption that the superheated vapor flows into the condenser inlet. And in order to consider the effect of pressure change in the dynamic characteristics of the condenser the combined system of condenser and compressor was used. By using the equation of energy balance and the equation of mass balance, the basic equation for describing the dynamic characteristics of condenser can be derived. The transfer function for describing dynamic response of the condenser to flow rate change outlet can be obtained from using linearizations and Laplace transformations of the equation. From this transfer function, analytical investigation which affects the frequency responses of condenser has been made. Through this study, it became possible that the information about the dynamic characteristics of air-cooled condenser is offered. While the average heat transfer coefficient of the refrigerant side necessary for the theoretical calculation of the dynamic characteristics is given by calculation method for the tube length and pressure drop of air-cooled condenser.

Removal Characterics of $SO_x$ by CuO Impregnated ${\gamma}-Alumina$ (${\gamma}-Alumina$에 담지된 산화구리에 의한 $SO_x$가스의 제거 특성)

  • 이창선;윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.29-35
    • /
    • 1996
  • Numerical solutions were obtained to the model equations for various parameters characterizing the pore structure, effective internal diffusion and the chemical reaction constant. The conversion was decreased with the cause of pore closure at the surface of reacting particles, reduction of porosity, surface area of reaction and effective diffusion coefficient in the solid with the progress of reaction. Total conversion was strongly depend on the local conversion at surface. According to the decreasing of impregnated concentration of the copper oxide and the increase of the flue gases concentration, total conversion was increased. And the conversion were affected by gas flow rate and pore size distribution of the reacting solid.

  • PDF

The Characteristic of Floating Ring Seal with Modified Geometry Configuration (기하학적 형상 변경에 따른 플로팅 링 실의 특성 연구)

  • Kim, Kyoung-Wook;Kim, Chang-Ho;Ha, Tae-Wong;Lee, Yong-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1142-1148
    • /
    • 2006
  • The floating ring seal which is used in the high pressure turbo pump is frequently used in the oxidizer pump and the fuel pump of the turbo pump of the liquid propulsion rocket, because it is able to minimize clearance to decrease the leakage flow rate. But, floating ring seal has a tendency to increase the force which caused instability of system as the eccentricity ratio increases. In this paper, we devised design of floating ring seal which decrease contact area between floating and supporting ring. Modified floating ring seal has a tendency to decrease the eccentricity ratio compare with original floating ring seal. The whirl frequency ratio which is able to distinguish stability of system decrease compare with original floating ring seal

  • PDF

Griseofulvin-Phenobarbital Interaction(II) -Effects of Phenobarbital Pretreatment on Enterohepatic Recirculation of Griseofulvin in Rats- (그리세오풀린-페노바르비탈 상호작용(II) -Rat에 있어서 페노바르비탈 전처리가 그리세오풀빈의 장.간순환에 미치는 영향-)

  • Koh, Ik-Bae;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.17 no.1
    • /
    • pp.15-21
    • /
    • 1987
  • Effects of phenobarbital pretreatment on the pharmacokinetics of enterohepatic recirculating griseofulvin were investigated by comparing normal to bile duct cannulated rats and also the effects of enhanced endogeneous bile flow on the absorption of griseofulvin were studied by means of in situ recirculation method in phenobarbital-pretreated rats. Phenobarbital was administered orally for five days at the dose of 75 mg/kg/day. The influence of phenobarbital pretreatment on the absorption rate constant, area under the plasma concentration-time curve, maximum plasma concentration of orally administered griseofulvin was not found in bile duct cannulated rats. Decreased absorption clearance and apparent partition coefficient of griseofulvin in accordance with the amount of endogeneous bile juice seemed to be due to the decrease of thermodynamic activity of griseofulvin as bile forms the micelle with griseofulvin.

  • PDF

A study on the heat transfer of the turbocharged gasoline engine (터보과급 가솔린기관의 열전달에 관한 연구)

  • 최영돈;홍진관
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.69-82
    • /
    • 1988
  • Heat transfer experiment is carried out during the performance test of the 4-cylinder 4-stroke cycle turbo-charged gasoline engine. Cycle simulation employing the measured pressure in cylinder, the cooling water temperature and flow rate and others is carried out in order to calculate the gas temperature in cylinder. In this simulation combustion process was simulated by Annand's two zone model and suction, compression, and other processes are calculated completely. From this simulation, we can obtain not only the heat transfer coefficient but also the flame speed, turbulent burning velocity, flame factor and the boiling condition of cooling passage. The results are investigated with engine speed, equivalence ratio and spark advance.

  • PDF

Simultaneous Determination of Cinnamaldehyde and Coumarin in Oryeong-san using HPLC with Photodiode Array Detector

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.18 no.2
    • /
    • pp.251-257
    • /
    • 2010
  • Objectives : To develop and validate High-performance liquid chromatography-photodiode array methods for simultaneous determination of two constituents in Oryeong-san(ORS). Methods : Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array(PDA) detection at 280 nm, were used for quantification of the two marker components of ORS. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was $H_2O$ and solvent B was acetonitrile. Results : Calibration curves were acquired with correlation coefficient ($r^2$)>0.9999, and the relative standard deviation(RSD) values(%) for intra- and inter-day precision were not exceed 1.0%. The recovery rate of each compound was in the range of 93.01-104.16%, with an RSD less than 2.0%. The contents of two compounds in ORS were 1.10-3.72 mg/g. Conclusions : The established HPLC method will be helpful to improve quality control of ORS.

An Experimental Study on the Heat Transfer for a Packed Bed (충전내(充塡內)에서의 열전달특성(熱傳達特性)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Yoo, Ji-Oh;Yang, Han-Ju;Seo, Jeong-Yun
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.31-36
    • /
    • 1986
  • In this paper heat transfer characteristics in air-solid packed bed with spherical steel particles are studied experimentally. The effect of particle sizes (${\phi}1.5,\;{\phi}2.5,\;{\phi}3.96,\;{\phi}4.75,\;{\phi}5.95,\;{\phi}7.15$), bed sizes (${\phi}50,\;{\phi}60,\;{\phi}70,\;{\phi}80$) and mass flow rate are investigated. Also heat transfer effect of the bed with particles and without particles is compared in terms of heat transfer coefficient. As a result of this experiments, the following relation is obtained in the range of the Reynolds numbers 40 between 1500. $Nu= 0.8755\;Re^{0.6367}$ (40

  • PDF

Nose Landing Gear Drop-test Simulation using Numerical Analysis about Orifice (오리피스 유량해석을 통한 전륜 착륙장치의 착륙성능평가)

  • Hwang, Jaeup;Bae, Jaesung;Hwang, Jaihyuk;Hong, Yehsun;Park, Sangjoon;Chung, Taekyong
    • Journal of Aerospace System Engineering
    • /
    • v.8 no.1
    • /
    • pp.18-23
    • /
    • 2014
  • This thesis is simulated a aircraft nose landing gear drop-test. flow rate-to-pressure difference characteristics of damping orifices for a nose landing gear is investigated by CFD analyses. Orifice is kind of poppet valve type. it is simulated pressure drop with variable orifice area. it is simulated landing gear model by using ADAMS with CFD result. It's performance evaluated landing gear drop-test and analyzed the results.

이젝터가 부착된 냉동시스템의 성능실험

  • 이원희;김윤조;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.993-1001
    • /
    • 2001
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were performed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one evaporator) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flaw rate ratio of suction fluid to motive fluid increases. The COP of dual-evaporator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

  • PDF

Thermal Energy Extraction from Phase Change Material - by Means of Finned Thermosyphon - (상변화 물질로부터의 열에너지 추출에 관한 연구 - 핀이 부착된 열싸이폰 이용에 관하여 -)

  • Mok, Jai-Kyun;Yoo, Jai-Suk;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.8 no.1
    • /
    • pp.5-12
    • /
    • 1988
  • One of the effective means to transfer the heat into and from the energy storage medium is thermosyphon. In this study, a two-phase closed thermosyphon with circular fins was used to extract the thermal energy stored in paraffin wax (Sunoco p-116). Heat transfer characteristics along the heat flow path were investigated as well as the overall performance. Some of the important results are as follows: (1) The temperature distribution of the wax in the radial direction was always maintained fairly uniformly; (2) Compared with bare thermosyphon, the heat transfer rate was vastly improved in the early stage of the experiment; and (3) Heat transfer coefficient between the wax and evaporating section of thermosyphon remained nearly constant during the experiment.

  • PDF