• Title/Summary/Keyword: Flow-induced Vibration

Search Result 441, Processing Time 0.03 seconds

Numerical Analysis of Flow-Induced Noise in Suction Nozzle of a Vacuum Cleaner with a Rotary Fan (팬이 장착된 진공청소기 흡입 노즐내 유로 유동 소음해석)

  • Park, I-Sun;Lee, Sung-Cheol;Oh, Jang-Keun;Sohn, Chae-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.208-211
    • /
    • 2006
  • Flow resistance induced by each element in suction nozzle of a vacuum cleaner with a rotary fan is investigated numerically and its relation with flow-induced noise is examined. Flow resistance and vorticity in suction nozzle are calculated and it is found that they are closely related with flow-induced noise. From numerical results, it is suggested that reduction of flow resistance effectively increases all-suction performance and decreases sound pressure level of noise generated in the suction nozzle.

  • PDF

Study on Characteristics of Flow-Induced Vibrations of Two Circular Cylinders (두 원기둥의 유동에 기인한 진동 특성에 관한 연구)

  • Kim, Sang Il;Lee, Seung Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.359-366
    • /
    • 2013
  • This study aims to investigate the characteristics of the flow-induced vibrations of two circular cylinders. The characteristics of the flow-induced vibrations are examined for various flow velocities and spaces between the two cylinders when they are arranged in tandem, staggered, and side-by-side positions. The results are as follows: (i) Seven flow-induced vibration patterns are observed when the two circular cylinders are placed in either tandem, staggered, or side-by-side positions. (ii) The two cylinders induce a vibration because they affect each other. (iii) The easiest way to induce a vibration of the two cylinders is by placing them in the side-by-side position among the three arrangements (tandem, staggered, and side-by-side). (iv) The change in the maximum flow-induced vibration of the two cylinders depends strongly on the fluctuating lift forces of each of them.

Phenomenon Examination on High Vibration of NG Boiler in 320MW Thermal Power Plant (320MW 화력발전소 가스 보일러 고 진동 현상 규명)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Hyun;Kim, Hee-Soo;Lee, Doo-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1034-1039
    • /
    • 2006
  • Large-amplitude, combustion-induced oscillations are observed in most systems involving continuous flow, such as aeroengine afterburners, gas boilers and rocket motors. Strong furnace vibration is typically characterized by the presence of well developed standing waves in the furnace, generating high pressure pulsation and causing structural vibration of the furnace walls. 320MW NG boilers have been experienced high vibration frequently since reconstruction works. Excessive furnace vibration was encountered when a burner air rate is suddenly reduced during load zone changed from 270MW to 300MW. An investigation showed that the primary cause of the vibration was induced by combustion low air flow rate. This paper describes phenomenon examination on strong furnace vibration due to the change of boiler operating conditions.

  • PDF

Experimental investigation of vortex-induced aeroelastic effects on a square cylinder in uniform flow

  • Huang, Dongmei;Wu, Teng;He, Shiqing
    • Wind and Structures
    • /
    • v.30 no.1
    • /
    • pp.37-54
    • /
    • 2020
  • To investigate the motion-induced aeroelastic effects (or aerodynamic feedback effects) on a square cylinder in uniform flow, a series of wind tunnel tests involving the pressure measurement of a rigid model (RM) and simultaneous measurement of the pressure and vibration of an aeroelastic model (AM) have been systematically carried out. More specifically, the aerodynamic feedback effects on the structural responses, on the mean and root-mean-square wind pressures, on the power spectra and coherence functions of wind pressures at selected locations, and on the aerodynamic forces were investigated. The results indicated the vibration in the lock-in range made the shedding vortex more coherent and better organized, and hence presented unfavorable wind-induced effects on the structure. Whereas the vibration in the non-lock-in range generally showed insignificant effects on the flow structures surrounding the square cylinder.

FLUID-ELASTIC INSTABILITY OF ROTATED SQUARE TUBE ARRAY IN AN AIR-WATER TWO-PHASE CROSSFLOW

  • CHUNG HEUNG JUNE;CHU IN-CHEOL
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.69-80
    • /
    • 2006
  • Fluid-elastic instability in an air-water two-phase cross-flow has been experimentally investigated using two different arrays of straight tube bundles: normal square (NS) array and rotated square (RS) array tube bundles with the same pitch-to-diameter ratio of 1.633. Experiments have been performed over wide ranges of mass flux and void fraction. The quantitative tube vibration displacement was measured using a pair of strain gages and the detailed orbit of the tube motion was analyzed from high-speed video recordings. The present study provides the flow pattern, detailed tube vibration response, damping ratio, hydrodynamic mass, and the fluid-elastic instability for each tube bundle. Tube vibration characteristics of the RS array tube bundle in the two-phase flow condition were quite different from those of the NS array tube bundle with respect to the vortex shedding induced vibration and the shape of the oval orbit of the tube motion at the fluid-elastic instability as well as the fluid-elastic instability constant.

Numerical investigation on vortex-induced vibration response characteristics for flexible risers under sheared-oscillatory flows

  • Xue, Hongxiang;Yuan, Yuchao;Tang, Wenyong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.923-938
    • /
    • 2019
  • Surge motion of top-end platform induced by periodic wave makes marine flexible riser encounter equivalent sheared-oscillatory flow, under which the Vortex-induced Vibration (VIV) response will be more complicated than pure sheared flow or oscillatory flow cases. Based on a time domain force-decomposition model, the VIV response characteristics under sheared-oscillatory flows are investigated numerically in this paper. Firstly, the adopted numerical model is validated well against laboratory experiments under sheared flow and oscillatory flow. Then, 20 sheared-oscillatory flow cases with different oscillation periods and top maximum current velocities are designed and simulated. Under long and short oscillation period cases, the structural response presents several similar features owing to the instantaneous sheared flow profile at each moment, but it also has some different patterns because of the differently varying flow field. Finally, the effects and essential mechanism of oscillation period and top maximum current velocity on VIV response are discussed systematically.

Reduction of Flow-Induced Noise in Suction Nozzle of a Vacuum Cleaner by Adopting a Cross-Flow Fan (횡류팬을 적용한 진공청소기 흡입노즐내 유동 소음 저감에 관한 연구)

  • Park, I-Sun;Sohn, Chae-Hoon;Lee, Sung-Cheol;Oh, Jang-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.935-938
    • /
    • 2007
  • In suction nozzle of a vacuum cleaner, where flow-induced noise is generated mainly by flow resistance, several ideas to reduce noise are investigated. To increase fan performance, blade number is optimized and a centrifugal fan is replaced by a cross-flow fan, In addition, gear ratio of fan to drum brush is changed. It is found that fan performance is increased by adopting these methods. Next, the blade height of the fan is decreased to reduce sound pressure level, which causes inevitably decrease in fan performance. Eventually, flow-induced noise is reduced by 6.3 dBA in its overall level with the fan performance maintained.

  • PDF

Flow Induced Vibration and Suppression of Inclined Cylinder (유체유동에 의한 경사원주의 진동과 제진에 관한 연구)

  • 양보석;복정희일랑;암호탁삼
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1381-1390
    • /
    • 1992
  • This paper presents a dynamic characteristics of flow induced vibration of circular cylinder set with inclined angle against flow direction. The effect of the cylinder bounded by spiral fin and wire on the damping of flow induced vibration is investigated, i.e., inclined angle, spiral pitch angle and number of spiral thread are studied. As the results, the cylinder with spiral fin is most effective for the damping. Also the cylinder bounded by pitch angle 50.deg. and 2 spiral thread is most effective.

Analyzing for Refrigerant Induced Noise for Split Type Air Conditioner Indoor Unit (분리형 에어컨의 실내기 냉매 소음 저감 분석)

  • Aoyama Shigeo;Mo, Jin-Yong;Lee, Jae-Kwon;Song, Yong-Jae;Han, Hyung-Suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.3 s.108
    • /
    • pp.240-246
    • /
    • 2006
  • In the air-conditioner, refrigerant induced noise and vibration can be increased when the airflow rate is reduced in order to decrease the noise at the low mode. Through the test and analysis of this kind of noise, it can be verified that the main reasons of refrigerant induced noise are the velocity and flow Induced force of the refrigerant at the inlet of the evaporator, So, in order to reduce this velocity, quality at the evaporator inlet should be minimized. And, in order to reduce flow induced force of the refrigerant, sudden change of fluid flow must not be occurred. So, in this paper, we will review the characteristics of refrigerant cycle and find how the quality and flow induced force can be minimized.