• 제목/요약/키워드: Flow-Visualization

검색결과 1,522건 처리시간 0.029초

Time-resolved PIV와 POD기법을 이용한 단일노즐 버블링 유동 특성에 관한 연구 (Characteristics of Bubble-driven Flow by Using Time-resolved PIV and POD Technique)

  • 이승재;김종욱;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제6권1호
    • /
    • pp.41-46
    • /
    • 2008
  • In this paper, the recirculation flow motion and mixing characteristics driven by air bubble stream in a rectangular water tank is studied. The time-resolved PIV technique is adopted for the quantitative visualization and analysis. 488 nm Ar-ion CW laser is used for illumination and orange fluorescent ($\lambda_{ex}=540nm,\;\lambda_{em}=560nm$) particle images are acquired by a PCO 10bit high-speed CCD camera (1280$\times$1024). To obtain clean particle images, 545 nm long pass optical filter and an image intensifier are employed and the flow rates of compressed air is 3 l/min at 0.5 MPa. The recirculation and mixing flow field is further investigated by time-resolved POD analysis technique. It is observed that the large scale recirculation resulting from the interaction between rising bubble stream and side wall is the most dominant flow structure and there are small scale vortex structures moving along with large scale recirculation flow. It is also verified that the sum of 20 modes of velocity field has about 67.4% of total turbulent energy.

PIV와 LDV를 이용한 냉각수 토출구 주위의 와류 가시화 연구 (Visualization of Vortex Flow around Coolant Outlets Using PIV and LDV)

  • 홍지우;신수용;안병권
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.136-142
    • /
    • 2021
  • Submerged and semi-submerged vehicles expel cooling water through an outlet. In this process, induced noise and vibration by the flow around the outlet have been reported, and it may cause problems directly related to survivability of the navy vessels. The coolant outlet has a net-type structure and circular columns are mostly used. In this study, flow measurements using PIV and LDV were performed for different type outlets; conventional (flat plate with round bar) and improved (flat and flat plate) configurations. Experiments were conducted at a cavitation tunnel where pressure and steady flow rate conditions are ensured for sufficient time to measure the flow. The average velocity field of the outlets were measured and compared through LDV measurements, and instantaneous vorticities were evaluated through PIV measurements. The results show that the improved type of the outlet is advantageous in terms of flow stability compared to the conventional type of the outlet.

대용량 유동해석 데이터에서의 중요도 기반 스트림라인 생성 방법 (Method for Importance based Streamline Generation on the Massive Fluid Dynamics Dataset)

  • 이중연;김민아;이세훈
    • 한국콘텐츠학회논문지
    • /
    • 제18권6호
    • /
    • pp.27-37
    • /
    • 2018
  • 스트림라인 생성은 유동해석 데이터에서 유동의 흐름을 해석하기 위한 대표적인 가시화 기법이다. 그러나 효과적인 스트림라인 배치를 위한 씨드 포인트의 위치를 결정하는 것은 매우 어려운 문제이다. 한편, 대용량의 유동해석 데이터에서 씨드 포인트 결정과 스트림라인 생성 계산은 매우 오랜 시간을 필요로 한다. 본 논문에서는 효과적인 스트림라인 배치를 위해 유동해석 데이터의 중요도를 기반으로 한 씨드 포인트 결정 방법과 분산병렬 가시화 시스템 환경에서의 병렬 처리 기법을 제안한다. 또한, GLOVE 가시화 시스템에서 실제 유동해석 데이터를 이용한 구현 결과를 소개하고 이를 통해 본 논문의 제안 방법을 검증하고자 한다.

루버 핀을 지나는 공기의 유동특성에 대한 기초적 연구 (A Basic Study on Air Flow Characteristics in Louvered Fins)

  • 강창수;최태민
    • 대한기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.1276-1293
    • /
    • 1993
  • 본 연구는 위에서 언급된 모델보다 훨씬 폭이 큰 23.5mm 루버 핀형 방열기용 열교환기를 모델로 삼고, 레이놀즈수가 500 이하인 저 레이놀즈수(100, 300, 500), 루버 각(22˚,24˚,28˚) 및 핀 피치 와 루버 피치의 비 Fp /Lp(1.23, 1.5) 등의 변화 에 따른 핀 내부의 유동, 전열 특성 및 압력분포등의 영향을 유한차분법으로 수치해석 하였다. 또한 동일한 루버 핀에대해 13:1 모델을 제작하여 염료주입법에의한 유동의 가시화 실험을 하였으며, 그 결과를 수치해석 결과와 비교 검토하였다.

제상모드에 대한 실차 내부 환기유동의 정량적 가시화 연구 (Quantitative Visualization of Ventilation Flow for Defrost Mode in a Real Passenger Car)

  • 이진평;이상준
    • 한국가시화정보학회지
    • /
    • 제8권2호
    • /
    • pp.40-44
    • /
    • 2010
  • Thermal comfort inside a passenger car has been receiving large attention in automobile industries. Especially, the performance of windshield defroster is important in the design of a car to ensure passenger comport and safety. Thereby, better understanding on the ventilation flow along the vehicle windshield is essential to evaluate the performance of windshield defroster. However, most previous studies dealt with the defrost flow using CFD (computational fluid dynamics) calculations or scale-down model experiments. In this study, a real commercial automobile was used to investigate the flow discharged from the vehicle defroster and the ventilation flow along the windshield using a PIV velocity field measurement technique. The experimental data would be useful to understand the flow characteristics in detail and also can be used to validate numerical predictions.

PIV를 이용한 Uni-flow 소기방식 프리피스톤 수소기관의 실린더내 유동가시화 (Flow visualization used PIV of hydrogen fueled free piston engine with uni-flow scavenging)

  • 조형욱;윤재성;이종태;임희수
    • 한국수소및신에너지학회논문집
    • /
    • 제19권3호
    • /
    • pp.182-188
    • /
    • 2008
  • In order to improve scavenging performance of free piston hydrogen fueled engine, this study estimate compatibility of uni-flow scavenging. The scavenging flow characteristics in the cylinder is investigated by flow visualization and PIV method. Consequently it has been found that the scavenging performance decreased with abnormal expansion of piston and delay of the exhaust valve opening timing. And the scavenging performance of exhaust valve located center in cylinder head is better than that of exhaust valve located side in cylinder head.

Flow Field Analysis inside Intake Nozzles of a Household Vacuum Cleaner

  • Daichin Daichin;Lee Sang Joon
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.733-736
    • /
    • 2002
  • The inside configuration of intake nozzle of vacuum cleaner greatly affects the dust-collection efficiency and acoustic-noise effect generated from flow separation Interaction between high-speed flow and internal structure. In order to improve the performance of the vacuum cleaner, flow fields inside the intake nozzles were investigated using flow visualization and FIV (Particle Image Vetocimetry) technique. The measurement to aerodynamic power, suction efficiency and noise level were also carried out. Valuable information was obtained from the experiments, revealing how to modify the intake nozzle. In this paper, the results of visualization, velocity distribution of flow fields, aerodynamic power, suction efficiency and noise level are discussed.

  • PDF

사각용기에서 발생하는 고점성 유체의 슬로싱 유동 (Sloshing Flow of Highly-Viscous Fluid in a Rectangular Box)

  • 박준상
    • 한국가시화정보학회지
    • /
    • 제17권3호
    • /
    • pp.39-45
    • /
    • 2019
  • A study on the sloshing flow of highly-viscous fluid in a rectangular box was made by both of theoretical approach and experimental visualization method. Assuming a smallness of external forcing to oscillate the container, it was investigated a linear sloshing flow of highly-viscous fluid utilizing asymptotic analysis by Taylor-series expansion as a small parameter Re (≪1) in which Re denotes Reynolds number. The theory predict that, during all cycles of sloshing, a linear shape of free surface will prevail in a bulk zone and it has confirmed in experiment. The relevance of perfect slip boundary condition, adopted in theoretical approach, to the bulk zone flow at the container wall was tested in experiment. It is found that quasi-steady coated thin film, which makes a lubricant layer between bulk flow and solid wall, is generated on the wall and the film makes a role to perfect slip boundary condition.

PIV를 이용한 파형채널 입구영역의 유동특성에 관한 연구 (A Study on Flow Characteristics of the Entrance Region of Wavy Channel by PIV)

  • 이철재;조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.912-917
    • /
    • 2009
  • An experimental flow visualization study of the entrance section of channels formed with wavy plates was made. The experiments were conducted in a water channel and a laser illuminated particle tracking was used as the technique of flow visualization. The flow region that were found in the experiments are steady, unsteady and significantly-mixed flows. Instabilities of the flow first appear near the exit of the channel. As the Reynolds number increases, the flows are characterized by the appearance of flow separation and the growth of recirculation region.

Visualization Analysis of Correlation between Fiber Orientation Angles and Flow Patterns by Gate-Magnetization Method

  • Miyauchi, Hidekazu;Imade, Masaaki;Okada, Saburo;Yokoi, Hidetoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.86.4-86
    • /
    • 2001
  • This paper presents the results of a visualization analysis of the correlation between the fiber orientation and flow pattern in injection molding using the Gate-magnetization method developed for the precise visualization of melt flow. The results of the comparisons of the fiber orientation angles with the flow patterns by the Gate-Magnetization method for GPPS mixed with glass fibers show the strong correlation between the flow patterns and fiber orientation angles. According to forward movement of the flow, the fiber orientation patterns move toward the side walls following the flow patterns. These results elucidate that fibers are oriented in the expansion process of the melt, and ...

  • PDF