• 제목/요약/키워드: Flow velocity measurement

검색결과 743건 처리시간 0.038초

Measurement and estimation of transpiration from an evergreen broad-leaved forest in japan

  • Hirose, Shigeki;Humagai, Tomo′omi;Kumi, Atsushi;Takeuchi, Shin′ichi;Otsuki, Kyoichi;Ogawa, Shigeru
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2001년도 학술발표회 논문집(I)
    • /
    • pp.52-59
    • /
    • 2001
  • Methods to measure and estimate transpiration of a forest composed of evergreen broad-leaved trees (Pasania edulis Makino) are studied. Heat pulse velocity has been measured along with soil moisture and micrometeorological factors at the Fukuoka Experimental Forest, the Research Institute of Kyushu University Forests in Fukuoka, Japan (33$^{\circ}$38'N, 130$^{\circ}$31'E, alt. 75m). Tree cutting measurement was conducted to convert the heat pulse velocity into sap flow and transpiration. A big leaf model to calculate transpiration and Interception loss is examined and the estimated values are compared with the measured values obtained from the heat pulse measurement. The results show that 1) Pasania edulis Makino posessing radial pore structure had relatively high water content and high heat pulse velocity even within the central part of the stem near the pith, 2) the heat pulse velocity was well correspond to the water uptake in the tree cutting measurement, 3) the estimation of sap flow based on the heat pulse velocity is accurate, and 4) the big leaf model using the parameters obtained from measurement of a portable photosynthesis system in one day in summer gives reasonable estimation of transpiration independent of seasons and weather.

  • PDF

PIV measurement of roof corner vortices

  • Kim, Kyung Chun;Ji, Ho Seong;Seong, Seung Hak
    • Wind and Structures
    • /
    • 제4권5호
    • /
    • pp.441-454
    • /
    • 2001
  • Conical vortices on roof corners of a prismatic low-rise building have been investigated by using the PIV(Particle Image Velocimetry) technique. The Reynolds number based on the free stream velocity and model height was $5.3{\times}10^3$. Mean and instantaneous vector fields for velocity, vorticity, and turbulent kinetic energy were measured at two vertical planes and for two different flow angles of $30^{\circ}$ and $45^{\circ}$. The measurements provided a clear view of the complex flow structures on roof corners such as a pair of counter rotating conical vortices, secondary vortices, and tertiary vortices. They also enabled accurate and easy measurement of the size of vortices. Additionally, we could easily locate the centers of the vortices from the ensemble averaged velocity fields. It was observed that the flow angle of a $30^{\circ}$ produces a higher level of vorticity and turbulent kinetic energy in one of the pair of vortices than does the $45^{\circ}$ flow angle.

Measurement of suction air amount at reciprocating engine under stationary and transient operation

  • Kubota, Yuzuru;Hayashi, Shigenobu;Kajitani, Shuichi;Sawa, Norihiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1037-1042
    • /
    • 1990
  • The air-fuel ratio of an internal combustion engine must be controlled with accuracy for the improvements of exhaust emission and fuel consumption. Therefore, it is necessary to measure the exact instantaneous amounts of fuel and suction air, so we carried out the experiments for measuring the air flow velocity in a suction pipe of an internal combustion engine using three types of instantaneous air flowmeter. The results obtained can be summarized as follows: (1) The laminar-flow type flowmeter is able to measure both the average and the instantaneous flow rate, but it is necessary to rectify the pulsating air flow in the suction pipe. (2) The a spark-discharge type flow velocity meter is able to measure the instantaneous air velocity, but it is necessary to choose the suitable electrode form and the spark character. (3) The tandem-type hot-wire flow velocity meter indicates the instantaneous flow velocity and its flow direction.

  • PDF

Particle Image Velocimetry 기법을 이용하여, Chemical Mechanical Polishing 공정시 Slurry 유동장 측정 (Measurement of the Slurry Flow-Field during Chemical Mechanical Polishing)

  • 신상희;김문기;고영호;김호영;이재동;홍창기;윤영빈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.125-128
    • /
    • 2004
  • Chemical Mechanical Polishing(CMP) in semiconductor production is characterized its output property by Removal Rate(RR) and Non-Uniformity(NU). Some Previous works shows that RR is determined by production of pressure and velocity and NC is also largely affected by velocity of flow-field during CMP. This study is about the direct measurement of velocity of slurry during CMP and reconstruction whole flow-field by Particle Image Velocimetry(PIV) Techniques. Typical PIV system is tuned adequately for inspecting CMP and Slurry Flow-field is measured by changing both Pad RPM and Carrier RPM. The results show that velocity is majorly determined not by Carrier RPM, but by Pad RPM.

  • PDF

화상처리기법을 이용한 온도장 및 속도장 동시 측정기법 개발 (Simultaneous velocity and temperature measurement of thermo-fluid flows by using particle imaging technique)

  • 이상준;백승조;윤정환;도덕희
    • 대한기계학회논문집B
    • /
    • 제20권10호
    • /
    • pp.3334-3343
    • /
    • 1996
  • A quantitative flow visualization technique was developed to measure velocity and temperature fields simultaneously in a two-dimensional cross section of thermo-fluid flows. Thermochromic liquid crystal(TLC) particles are used as temperature sensor and velocity tracers. Illuminating a thermo-fluid flow with a thin sheet of white light, the reflected colors from the TLC particles in the flow were captured simultaneously by two CCD cameras; a 3-chip CCD color camera for temperature field measurement and a black and white CCD camera for velocity field measurement. Variations of temperature field were measured by using a HSI true color image processing system and TLC solution. The relationship between the hue values of TLC color image and real temperature was obtained and this calibration curve was used to measure the true temperature under the same camera and illumination condition. The velocity field was obtained by using a 2-frame PTV technique using the concept of match-probability to track true velocity vectors from two consecutive image frames. These two techniques were applied at the same time to the unsteady thermal-fluid flow in a Hele-Shaw cell to measure the temperature and velocity field simultaneously and some results are discussed.

산지하천의 전자파 표면유속 측정에 기반한 유량 및 유속 관측 오차 분석 (Error Analysis for Electromagnetic Surface Velocity and Discharge Measurement in Rapid Mountain Stream Flow)

  • 김동수;양성기;정우열
    • 한국환경과학회지
    • /
    • 제23권4호
    • /
    • pp.543-552
    • /
    • 2014
  • Fixed Electromagnetic Wave Surface Velocimetry (Fixed EWSV) has been started to be used to measure flood discharge in the mountain stream, since it has various advantages such that it works well to continuously measure stream discharge even in the night time as well as very strong weather. On the contrary, the Fixed EWSV only measures single point surface velocity, thus it does not consider varying feature of the transverse velocity profile in the given stream cross-section. In addition, a conventional value of 0.85 was generally used as the ratio for converting the measured surface velocity into the depth-averaged velocity. These aspects could bring in error for accurately measuring the stream discharge. The capacity of the EWSV for capturing rapid flow velocity was also not properly validated. This study aims at conducting error analysis of using the EWSV by: 1) measuring transverse velocity at multiple points along the cross-section to assess an error driven by the single point measurement; 2) figuring out ratio between surface velocity and the depth-averaged velocity based on the concurrent ADCP measurements; 3) validating the capacity of the EWSV for capturing rapid flow velocity. As results, the velocity measured near the center by the fixed EWSV overestimated about 15% of the cross-sectional mean velocity. The converting ratio from the surface velocity to the depth-averaged velocity was 0.8 rather than 0.85 of a conventional ratio. Finally, the EWSV revealed unstable velocity output when the flow velocity was higher than 2 m/s.

속도 계측형 호흡기류센서 설계를 위한 비균등 샘플링 기법 (Unequal Distance Sampling Technique to Design Velocity-Type Respiratory Air Flow Transducer)

  • 김경아;이태수;차은종
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권5호
    • /
    • pp.351-359
    • /
    • 2004
  • 속도계측형 호흡기류센서는 베르누이 원리에 의해 기류속도를 동압력으로 변환하여 호흡기류를 측정하는 센서로써 다수의 샘플링 구멍을 기류통과면 상에 설치해야 한다. 본 연구에서는 속도 샘플 구명들을 비균등하게 배치시킴으로써 단순하게 균등 배치하는 것보다 훨씬 정확한 기류 계측이 가능함을 이론적으로 입증하였다 컴퓨터 시뮬레이션 결과 기류통과면을 다수의 등면적 링으로 분한하고 각각의 링의 면적을 다시 2등분하는 위치에서 속도를 샘플링함으로써 균등 배치할 경우에 비해 계측오차가 약 1/5로 감소하였다. 또한 충 샘플개수가 4개 이상이면 상대오차 1% 이내의 매우 정확한 기류계측이 가능하였다. 기류 속도분포의 변화에 따른 영향을 비교한 결과 균등 샘플링에 비해 1/2 이하로 둔감하였다. 따라서 본 인구에서 제안하는 비균등 속도샘플링 기법은 속도 계측형 호흡기류센서의 설계시 매우 유용하게 적용될 것으로 판단된다.

배수갑문 물받이의 수리현상에 관한 연구 (A Study on the Hydroulic Phenomenon at the Douvstream Channel of the Drainage Sluice)

  • 이희영
    • 한국농공학회지
    • /
    • 제18권4호
    • /
    • pp.4218-4225
    • /
    • 1976
  • To insure the safety of the drainage sluice, topogrophical change due to erosion as well as capability of discharging the design flow in a very important factor. In consideration of the fact that the drainage sluice is built in the sea, its construction has many topographically restricted problems and naturally requires a completeness of research and experiment. This thesis is a comparative and analytic study of discharging flow acting on the erosion at the bottom of the structure on the basis of the measured velocity on the downstream channel of the drainage sluice. (1) The measured velocity shows a little higher values than the computed velocity, because the measured velocity was observed at the surface of the stream. There fore, it is reasonable that the compated velocity should be taken in this study. (2) The field observation was conducted to have the measurement of the flow velocity without surveying the area of flow. Therefore, the coefficient of discharge could not be computed. The survey of the area of flow is planned to be conducted along with the measurement of the flow velocity. (3) The apron of the drainage sluice is free discharging type and it was designed to be about 80m in length less than it should be. (4) The apron of free flow discharging type should have a solid foundation to protect the structure by preventing erosion damage to upstream and downstream channels against weathering of rock and strong torrent. Whether free flow discharging type or energy-dissipating type is best chosen depends on the topographical condition of the forage site, therefore, there would be a comparative study before the final decision was made about the protrection for the structure. (5) It is considered to be appropriate that the design and construction of the drainage sluice should have a complete study which is based on hydraulie model test before the type of protection is decided. (6) It is much requested that a variety of experiment equipments be installed and observed to study the protection for the drainage sluice.

  • PDF

Micro-PIV Measurements of In Vitro Blood Flow in a Micro-Channel

  • Park, Cheol-Woo;Lee, Sang-Joon;Shin, Se-Hyun
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제1권2호
    • /
    • pp.30-35
    • /
    • 2003
  • Flow characteristics of blood flow in a micro channel were investigated experimentally using a micro-PIV (Particle Image Velocimetry) velocity field measurement technique. The main objective of this study was to understand the real blood flow in micron-sized blood vessels. The Reynolds number based on the hydraulic diameter of micro-channel for deionized (DI) water was about Re=0.34. For each experimental condition, 100 instantaneous velocity fields were captured and ensemble-averaged to get the spatial distributions of mean velocity. In addition, the motion of RBC (Red Blood Cell) was visualized with a high-speed CCD camera. The captured flow images of nano-scale fluorescent tracer particles in DI water were clear and gave good velocity tracking-ability. However, there were substantial velocity variations in the central region of real blood flow in a micro-channel due to the presence of red blood cells.

  • PDF

전자기 토모그래피를 이용한 액체 금속 속도장 측정 (Measurement of velocity Pronto in Liquid Metal Flow Using Electromagnetic Tomography)

  • 안예찬;김무환;최상호
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1271-1278
    • /
    • 2004
  • In order to measure non-intrusively velocity profile in liquid metal flow, a modified electromagnetic flowmeter was designed, which was based on electromagnetic tomography technique. Under the assumption that flow is fully-developed, axisymmetric and rectilinear, the velocity profile was reconstructed after the flowmeter equation, the first kind of Fredholm integration equation, was linearized. In reconstruction process Tikhonov regularization method with regularization parameter was used. The reconstructed velocity profile had the nearly same as turbulent flow profile which was approximately represented as log law. In addition, flowmeter output fur a fixed magnet rotation angle was linearly proportional to flow rate. When magnet rotation angle was 54$^{\circ}$, axisymmetric weight function was nearly uniform so that the flowmeter gives a constant signal for any fully-developed, axisymmetric and rectilinear profile with a constant flow rate.