• 제목/요약/키워드: Flow level

검색결과 4,333건 처리시간 0.04초

LNG 운반선의 자유수면을 포함한 자항상태 난류유동장의 수치해석 (RANS Computation of Turbulent free Surface Flow around a Self Propelled KLNG Carrier)

  • 김진;박일룡;김광수;반석호
    • 대한조선학회논문집
    • /
    • 제42권6호
    • /
    • pp.583-592
    • /
    • 2005
  • The turbulent free surface flow around a self-propelled KRISO 138K LNG Carrier is numerically simulated using the finite volume based multi-block RANS code, WAVIS developed at HRISO. The realizable k-$\varepsilon$ turbulence model with a wail function is employed for the turbulence closure. The free surface is captured with the Level-Set method and body forces are used to model the effects of a propeller without resolving the detail blade flow. In order to obtain an accurate free surface solution and stable convergence, the computations are executed with a proper fine grid refinement around the free surface and with an adoption of implicit discretization scheme for the Level-Set formulation. The computed velocity vectors at the several stations and wave patterns show a good agreement with the experimental results measured at the KRISO towing tank.

FESWMS-2DH를 이용한 하천의 흐름 해석 (Flow Analysis of Rivers by using FESWMS-2DH)

  • 이철응;심재욱;박동헌
    • 산업기술연구
    • /
    • 제29권A호
    • /
    • pp.111-122
    • /
    • 2009
  • In this study, flood stage was computed by HEC-RAS, 1-D numerical analysis model and FESWMS-2DH, 2-D numerical model. Flood stages computed by two different models were compared for straight line, dot axle watercourse, dead-zone watercourse, section sudden-changing watercourse, and curved watercourse. From the results, flow velocity and water level were similar in straight watercourse and dot-reduction watercourse. However, there was difference of flow velocity and water level in dead-zone watercourse, sudden expansion, dot-reduction, and curve-watercourse. This result might be influenced by rapid change of watercourse due to dead-zone, the angle of inflow and outflow, and the curvature. Especially in this study, numerical model was applied to Wol-Song-Cheon at Chuncheon in order to analyze the effect of flood stage by two different models. By flowing properties around the bridge and confluence of rivers, it was found that flow velocity and water level was changed. Therefore, it was concluded that a lot of uncertainties are contained in the present bank.

  • PDF

발전소 급수펌프 구동용 소형 터빈 제어시스템 소개 (An Introduction to Speed Control System of Small Steam Turbine for Feed Water Supply in Power Plant)

  • 최인규;김종안
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1603-1604
    • /
    • 2007
  • The load of power plants changes every from time to time according to which steam flow of boiler changes. the feed water control is very important for the power plant to be operated in its stability conditions. In case of circulation type boiler, the instability of feed water control leads to instability of drum level control. The higher level of drum water can induce bad quality steam to go into turbine which means the possibility of damage. The lower level of drum water can induce the tubes of boiler water wall to be overheated. In case of once through type boiler, the instability of feed water control leads to bad cooling of superheaters. The less the feed water flow is, the more heated the superheater is. It is necessary for the turbine driving feed water pump to be controlled for the optimal feed water flow in the large capacity power plant. The speed of turbine is controled for the feed water flow. By the way, the optimal control of steam valve is necessary for the speed control of turbine. Therefore, the various kinds of the steam valve structures are introduced in this paper

  • PDF

로봇제어기 냉각시스템분석을 위한 열유동 해석 (Flow and Thermal Analyses for Evaluation of a Robot Controller Cooling System)

  • 조기주;박성원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.414-418
    • /
    • 2001
  • Flow and thermal characteristics of cooling system for the robot controller were numerically as well as experimentally investigated. To obtain the overall flows within controller, the system level solutions were analysed at first and then the board level solutions were pursued to understand the detailed flow and temperature fields near the main board which have a significant influence on the cooling of electronic components. The evaluation for a performance of the heat exchanger was conducted on the basis of the obtained flow and temperature patterns. The results showed that the heat exchanger made a small contribution to the cooling of controller and caused an increase of the temperature in CPU.

  • PDF

고속유동장내 액체분열현상 (Phenomena of Liquid Jet Breakup in High Speed Gas Stream)

  • 박용국;석지권;이충원
    • 한국분무공학회지
    • /
    • 제1권2호
    • /
    • pp.66-73
    • /
    • 1996
  • The present study investigates experimentally the characteristics of liquid jet, which is, the spray flow in the normal direction of the air stream under the flow conditions of air velocity $110\sim125m/s$. The present study adopts with the flow visualization technique using a short duration light bulb and the image processing analyse with CCD camera. Two types of injector were used: one is a flat plate type, and the other is backward facing step type, which height are 5, 8, 10mm. Dispersion of liquid jet can be represented by gray level of CCD camera. In the upstream of liquid jet, the backward facing step shows better liquid jet penetration. However, in the downstream. mean droplet size for backward facing step injector is smaller than that for flat plate injector

  • PDF

3차원 유동해석을 통한 차량 배기소음 예측에 관한 연구 (Prediction of Vehicle Exhaust Noise using 3-Dimensional CFD Analysis)

  • 진봉용;이상호;조남효
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.148-156
    • /
    • 2001
  • Computational Fluid Dynamics (CFD) analysis was carried out to investigate exhaust gas flow and acoustic characteristics in the exhaust system of a passenger car. Transient 3-dimensional flow field in the front and rear mufflers was simulated by CFD and far-field sound pressure was modeled by a simple monopole source method. Engine performance simulation was also performed to obtain the boundary condition of instantaneous fluid flow variation at the inlet of the exhaust system. Detailed exhaust gas flow characteristics such as velocity and pressure distribution inside the mufflers were presented and the pulsating pressure amplitude was compared at several positions in the exhaust system to deduce sound pressure level. The present method of the acoustic analysis coupled with CFD techniques would be very effective for the prediction of sound noise from vehicle exhaust systems although the effects of the inlet boundary condition and heat transfer on the accuracy of the prediction have to be validated through further studies.

  • PDF

Water Masses and Flow Fields of the Southern Ocean Measured by Autonomous Profiling Floats (Argo floats)

  • Park, Young-Gyu;Oh, Kyung-Hee;Suk, Moon-Sik
    • Ocean and Polar Research
    • /
    • 제27권2호
    • /
    • pp.183-188
    • /
    • 2005
  • Using data from Argo floats collected in the Southern Ocean, we describe water mass prop erties and flow fields at intermediate levels (1000m and 2000m levels). Water mass properties from Argo floats, which are consistent with those from previous hydrographic surveys, reflect the movement of the floats well even without quality control on the Argo data. Since the flow fields from the Argo floats do not cover the entire Southern Ocean, we could not obtain a general circulation pattern, especially at the 2000m level. We, however, can confirm the general eastward tendency due to ACC largely following the topography.

SPH 기법을 이용한 주조공정 용탕 주입 유동 해석 (Molten Metal Flow Analysis of Casting Process Using SPH Method)

  • 박병래;이상욱
    • 한국가시화정보학회지
    • /
    • 제16권1호
    • /
    • pp.54-60
    • /
    • 2018
  • It is important to develop more efficient and productive casting processes for an automated high precision molten-metal casting system. Detailed analysis of molten-metal flow in the casting process by the numerical approach will help to optimize the control of a ladle. In this study, the smoothed particle hydrodynamics method was applied to analyze casting flow characteristics with different tilting angular speed and initial molten-metal level. The smoothed particle hydrodynamics technique has advantages to easily handle non-linear free surface behavior with the absence of a computational mesh. We found that tilting angular speed has relatively greater effect on the casting flowrate and that the effect of the initial molten-metal level is only minor. Further extensive study will be necessary to find an optimal condition for high efficient casting system.

고속회전 육각형 디스크의 유동기인 소음저감에 관한 연구 (A Study on the ]Reduction of Flow induced Acoustic Noise for a High-speed Rotating Hexagonal Disk)

  • 한지민;임윤철
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.71-74
    • /
    • 2005
  • The present study describes the prediction of the flow induced noise level of a high-speed rotating hexagonal disk and proposes the way how to reduce it. Since a hexagonal disk, which is used in the laser printer and named a Polygon mirror, has six sharp corners, there are low and high pressure regions on each of six edges when it rotates. Therefore, the pressure difference generates three dimension flow field and causes aerodynamic noise. The Ffowcs-Williams and Hawkings (FWH) method is employed for the analysis. We have measured the sound pressure levels and compared them with the computational results. The calculated sound pressure levels agree well with the experimental results. We modified the shape of the edges of a hexagonal disk to reduce the noise level and confirm their effects through numerical computation.

  • PDF

공기 양정(air lift) 펌프를 응용한 슬러지 배출장치에 대한 연구 (Application of Air Lift Pump for Sludge Discharger)

  • 안갑환;박영식
    • 한국환경과학회지
    • /
    • 제13권10호
    • /
    • pp.929-938
    • /
    • 2004
  • Sludge discharger applied the principle of the air lift pump was investigated experimentally for the different design( diameter of discharge pipe, diameter and height of the inside and outside wall) and operating parameters(air flow rate, water level). And it was conducted that performance comparison about sludge discharger and conventional air lift pump. The result indicated that discharged liquid were increased with the increase of air flow rate and water level and decrease distance between inside and outside wall. The discharge pressure was increased with an increase of air flow rate and a decrease of the diameter of the discharge pipe, for both the sludge discharger and the airlift pump. The discharge pressures of the sludge discharger were 3-6 times higher than those of the air lift pump.