• 제목/요약/키워드: Flow injection analysis (FIA)

검색결과 45건 처리시간 0.023초

흐름주입분석법에 의한 주방용기로부터 용출된 알루미늄의 정량 (Determination of Aluminum Leached from Cooking Utensils by using Flow Injection Analysis)

  • 최용욱
    • 한국물환경학회지
    • /
    • 제20권3호
    • /
    • pp.281-289
    • /
    • 2004
  • Optimal analytical conditions have been established for mixing and reaction coil length, concentrations of ECR, CTAB, and acetate, reaction temperature and pH in the determination of aluminum by using flow injection analysis(FIA). Detection limit and repeatability for this system were $3{\mu}g/L$ and better than 1% of relative standard deviation, respectively. The interference from iron(III) was suppressed up to 6mg/L of iron(III) by $0.1{\mu}M$ ascorbic acid, and the interference from fluoride could be tolerated in absorption of Al/ECR/CTAB derivative by 10mM boric acid at pH 3.5 adjusted with nitric acid. This FIA system was applied to the determination of aluminum leached from cooking utensils by distilled and tap water containing fluoride ranged from 0.5 to 2mg/L by measurement of absorbance for Al/ECR/CTAB at 585nm. The leached aluminum content was increased with increasing concentration of fluoride. The aluminum contents leached from aluminum utensils by tap water were about 9 fold higher than those leached by distilled water, whereas aluminum contents leached by distilled water containing fluoride were about 2 fold higher compared to those leached by distilled water. That represented that other dissolved substances as well as fluoride in tap water contributed to liberation of aluminum from aluminum utensils. A comparison between FIA data and ICP-AES data by correlation and paired t test showed that the FIA system could be accepted as a good alternative method for the determination of aluminum in tap water.

FET형 용존 산소 센서의 유속에 의한 영향 조사와 감쇄 기법 (Investigation of the Flow Dependence of a FET-Type Dissolved Oxygen Sensor and Its Reducing Method)

  • 정훈;김영진;이영철;손병기
    • 센서학회지
    • /
    • 제10권3호
    • /
    • pp.180-186
    • /
    • 2001
  • 최근 전류 법적인 Clark형 센서의 단점을 극복하기 위해 FET형 용존 산소 센서가 제안되었다. 그러나 제안된 센서의 출력은 작업전극에서 발생하는 pH의 변화를 감지하기 때문에 유속에 대한 영향을 받는다. 본 논문에서는 FIA(flow injection analysis)를 이용하여 유속의 영향을 최소화 할 수 있는 방향을 결정하였다. 그리고 완충막을 작업전극과 감지막 위에 형성시켜 작업전극과 감지부가 측정용액에 직접 노출되어 용액의 유동에 의해 센서의 출력이 불안정한 문제를 개선하였다. TEOS(tetraethylorthosilicate)와 DEDMS(diethoxydimethylsilane)를 혼합하여 졸-겔법으로 완충막을 형성하였다.

  • PDF

흐름주입분석기술을 이용한 생물공정에서 암모니아 농도의 제어 (Control of Ammonium Concentration in Biological Processes Using a Flow Injection Analysis Technique)

  • 이종일
    • KSBB Journal
    • /
    • 제16권5호
    • /
    • pp.452-458
    • /
    • 2001
  • 생물공정에서 암모니아 농도를 제거하기 위해 NN 제어기를 개발하였고 기존의 PID 제어기와 비교하였다. 특히, 생물반응기내 암모니아 농도를 온라인 모니터링하기 위해 암모니아-FIA 장치를 사용하였으며, 이 장치의 분석 오차, 분석 시료의 체류 시간 등의 제어 특성에 대한 영향 computer simulation을 통해 비교, 고찰하였다. 또한 computer simulation에 의해 생물공정에 적합한 인공 신경망 제어구조를 고찰하였고, 3-2-1 구조의 NN 제어기가 PID 제어기보다 우수함을 알수 있었다. 3-2-1 구조의 NN 제어기를 이용하여 모사 생물공정 및 yeast 발효공정에서 암모니아 농도를 제어하여 그 특성을 고찰하였다. 본 연구로부터 미생물의 비선형성장 특성을 가진 생물공정에서 기질의 농도를 제어하기 위해서는 3-2-1 구조의 인공 신경망 제어기가 적합함을 알 수 있었다.

  • PDF

Determination of Ammonia-N in Environmental Water by Air-segmented FIA

  • Feng, Yong-Lai;Tian, Li-Ching;Wang, Wei;Wu, Qiao-Znen
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.787-792
    • /
    • 1995
  • A method for determination of ammonia-N in environmental water by air-segmented flow injection analysis using the colour reaction of phenol and sodium hypochlorite with ammonia was described in this paper. When the reaction temperature is $70^{\circ}C$ and the reaction residence time is 5 minutes, a sample frequency of $60-90h^{-1}$ can be achieved. The detection limit and relative deviation are $0.05mg.ml^{-1}$ and 4%, respectively. The recovery of this method is 96 - 110%, and the determination results of the method are greatly agreement with standard colorimetric method.

  • PDF

Pulsed Amperometric Detection of Metal Ions Complexing with EDTA in a Flow Injection System

  • 이준우;여인형;편종홍
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권3호
    • /
    • pp.316-318
    • /
    • 1997
  • A general and universal detection method, which can be used in high performance liquid chromatography (HPLC) and flow injection analysis (FIA) system for the determination of any metal ions complexing with ethylenediaminetetraacetic acid (EDTA), is demonstrated. Pulsed amperometric detection scheme is applied in a flow-through thin layer electrochemical cell at an Au working electrode. Fluctuation of peak current level at the same flow rate of carrier solution is minimized at this solid working electrode, whereas not at a dropping mercury electrode. Removal of dissolved oxygen can be omitted with this detection method, which is a required step for cathodic detection methods. Also, a group of metal ions can be determined selectively and indirectly with this detection scheme.

Fluorimetric Determination of Phosphate in Sea Water by Flow Injection Analysis

  • Motomizu, Shoji;Oshima, Mitsuko;Katsumura, Naoya
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.843-848
    • /
    • 1995
  • A sensitive method for the determination of trace amounts of phosphate by fluorescence-quenching detection / FIA is proposed. The fluorescence of Rhodamine B(RB) was quenched with the formation of the ion associate of molybdophosphate with RB;${\lambda}_{ex}$ and ${\lambda}_{em}$ were 560nm and 580nm, respectively. A calibration graph was linear over the ranges from $10^{-8}$ to $3{\times}10^{-6}M$ of phosphate (~0.3~93ppb of phosphorus). The relative standard deviation was 1.2% with $8{\times}10^{-7}M$ phosphate solution and sampling rate was 15 samples / h. The proposed method was applied to the determination of phosphate in sea and river water samples.

  • PDF

흐름주입 분석에 의한 아염소산 이온의 분광광도법 정량 (Photometric Determination of Chlorite ion by Flow Injection Analysis)

  • 최용욱;이수영;김미경;박성호
    • 대한화학회지
    • /
    • 제44권6호
    • /
    • pp.556-562
    • /
    • 2000
  • 간접 요오드화법의 UV 검출을 이용한 흐름주입분석에 의한 아염소산 이온의 정량에 관하여 연구하였다. 산성 조건하에서 아염소산은 요오드화 이온을 요오드로 산화시키고 자신은 염화 이온으로 환원된다. UV 370nm에서 노란 색으로 발색된 요오드의 흡광도를 측정하여 아염소산 이온을 간접적으로 정량 하였다. 흐름주입분석-UV검출 장치를 이용한 무기성 소독부산물인 아염소산 이온을 선택적으로 정량하기 위한 분석 인자로서 혼합 및 반응코일 길이, 산성 용리액의 pH, 요오드화 이온의 농도, 주입고리부피, 반응 온도, 유속을 최적화 하였다. 조제수로부터 산화제나 방해 물질들을 제거하기 위한 가리움제를 조사하였다. 아염소산 이온에 대한 0.002~0.2 mg/L의 선형 농도 범위에서 검정곡선은 0.999이상의 상관계수를 나타내였다. 아염소산 이온의 검출한계는 0.18 ${\mu}g/L$이었다.

  • PDF

전기화학적 방법을 이용한 다중 효소 전극 제작 및 글루코스 검출 특성에 관한 연구 (A Study on the Detection Characteristics in Glucose and Fabrication of Bi-Enzyme Electrode using Electrochemical Method)

  • 한경호;신인성;윤도영
    • 전기화학회지
    • /
    • 제23권3호
    • /
    • pp.66-72
    • /
    • 2020
  • 본 연구에서는 글루코스 검출을 위한 HRP (horseradish peroxidase)와 GOD (glucose oxidase)를 혼합한 형태의 다중 효소 반응 바이오센서 개발연구를 수행하였다. 바이오센서는 제작 시간 단축을 위하여 전기전착법을 이용하여 제작하였으며, 경제적인 센서 제작을 위하여 SPE (screen printed electrode)를 사용하였다. 다중 효소 바이오센서의 효과를 확인하기 위하여 단일 효소 바이오센서를 제작하여 비교 및 분석하였다. 센서의 특성을 평가하기 위해서 주사전자현미경(scanning electron microscopy, SEM), 순환전위법(cyclic voltammetry, CV), 전기화학적 임피던스 분광법(electrochemical impedance spectroscopy, EIS), 시간대전류법(chronoamperometry, CA), 흐름 주입분석법(flow injection analysis, FIA)를 수행하였다. SEM, CV, EIS의 분석결과로부터 효소가 전극 표면에 고정화가 잘 된 것을 확인하였고, CA로부터 제작된 다중 효소 바이오센서가 단일 효소 바이오센서에 비해 신호성능이 200% 향상된 것을 확인하였다. 이로부터 HRP와 GOD가 서로 촉매적으로 반응한다는 것을 설명할 수 있었다. 또한, FIA의 결과에서 동일한 농도의 글루코스 용액을 4회 나누어 주입하였을 때, 전류신호량이 일정함을 확인하였고, 농도에 따른 전류신호량을 분석하여 신호민감성, 재현성, 안정성 등이 우수함을 설명할 수 있었다.

A Sensitive Procedure for the Rapid Determination of Mandelic Acid by Flow Injection Analysis and Chemiluminescence Detection

  • Alam, Seikh Mafiz;Jeon, Chi-Wan;Karim, Mohammad Mainul;Lee, Sang-Hak;Wabaidur, Saikh Mohammad;Suh, Yeoun-Suk;Chung, Hye-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권1호
    • /
    • pp.102-106
    • /
    • 2009
  • A rapid and sensitive chemiluminescence (CL) method using flow-injection (FI) has been developed for the determination of mandelic acid which is based on the enhancement of mandelic acid to the CL intensity of ${Ru(bipy)_{3}}^{2+}$-Ce(IV) system. The enhancement effect was dependent on the concentration of mandelic acid, based on which, CL system was established for the determination of mandelic acid. The concentrations of ${Ru(bipy)_{3}}^{2+}$+, Ce(IV), and $H_2SO_4$ were optimized. Under the optimum experimental conditions, the linear range and detection limit are 1.46-342.0 ${\mu}g/ml$ and 0.072 ${\mu}g/ml$, respectively. The correlation coefficient (R) was 0.99732. The utility of this method was demonstrated by determining mandelic acid in capsules and human urine sample.

알콜증류폐액을 이용한 빵효모배양에서 Glucose와 Ammonium의 자동첨가에 의한 증균 : 온라인 FIA 시스템에 의한 Ammonium의 자동분석 및 제어 (Increase of Cell Concentration by the Automatic Addition of Glucose and Ammonium to an Alcohol Distillery Wastewater Reutilized for Cultivating a Baker's Yeast : Automatic Analysis and Control of Ammonium Concentration with an On-line Flow Injection Analysis System)

  • 이형춘
    • KSBB Journal
    • /
    • 제15권2호
    • /
    • pp.139-144
    • /
    • 2000
  • 알콜증류폐액에 빵효모를 배양하는 중에 glucose와 ammon-ium을 자동첨가하여 균체량을 효율적으로 증가시킴으로써 폐액의 재이용성을 향상시키고자 하였다. Glucose는 DO를 제어파라미터로 하는 제어방법을 사용하여 116 mg/L 이하로 자동제어하였다. Ammonium의 경우에는 FIA를 이용한 온라인 자동계측제어장치와 프로그램을 이용하여 배양액의 ammon-ium 농도를 자동분석하고 제어하였으며, ammonium 농도를 류.0~27.7 mM의 낮은 농도범위로 유지시킬 수 있었다. Ammo-nium 농도를 제어한 본 실험의 최대비증식속도는 0.21 hr-1이었고, 대당균체수율은 약 0.78 g/g 으로서 ammonium 농도를 제어하지 않은 경우에 비하여 대당균체수율은 약 1.4배, 최대비증식속도는 1.2배 더 높아졌으므로 ammonium 제어에 의하여 균의 glucose 이용효율이 더욱 향상되었다. 대암모늄균체수율은 약 11.3 g/g 이었다. Glucose와 ammonium을 첨가함으로써 균체량을 18.5 g/L 까지 높일 수 있었으며, 이는 첨가하지 않은 경우보다 7.1배 더 높은 균체량에 해당한다. Glucose와 ammonium의 농도를 낮게 유지시킬 수 있었으므로 두가지 영양성분의 경제적인 공급이 가능하였다.

  • PDF