• Title/Summary/Keyword: Flow duration function

Search Result 55, Processing Time 0.025 seconds

Derivation of the Instantaneous Unit Hydrograph and Estimation of the Direct Runoff by Using the Geomorphologic Parameters (지상인자에 의한 순간단위도 유도와 유출량 예측)

  • 천만복;서승덕
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.87-101
    • /
    • 1990
  • The purpose of this study is to estimate the flood discharge and runoff volume at a stream by using geomorphologic parameters obtained from the topographic maps following the law of stream classification and ordering by Horton and Strahier. The present model is modified from Cheng' s model which derives the geomorphologic instantaneous unit hydrograph. The present model uses the results of Laplace transformation and convolution intergral of probability density function of the travel time at each state. The stream flow velocity parameters are determined as a function of the rainfall intensity, and the effective rainfall is calculated by the SCS method. The total direct runoff volume until the time to peak is estimated by assuming a triangular hydrograph. The model is used to estimate the time to peak, the flood discharge, and the direct runoff at Andong, Imha. Geomchon, and Sunsan basin in the Nakdong River system. The results of the model application are as follows : 1.For each basin, as the rainfall intensity doubles form 1 mm/h to 2 mm/h with the same rainfall duration of 1 hour, the hydrographs show that the runoff volume doubles while the duration of the base flow and the time to peak are the same. This aggrees with the theory of the unit hydrograph. 2.Comparisions of the model predicted and observed values show that small relative errors of 0.44-7.4% of the flood discharge, and 1 hour difference in time to peak except the Geomchon basin which shows 10.32% and 2 hours respectively. 3.When the rainfall intensity is small, the error of flood discharge estimated by using this model is relatively large. The reason of this might be because of introducing the flood velocity concept in the stream flow velocity. 4.Total direct runoff volume until the time to peak estimated by using this model has small relative error comparing with the observed data. 5.The sensitivity analysis of velocity parameters to flood discharge shows that the flood discharge is sensitive to the velocity coefficient while it is insensitive to the ratio of arrival time of moving portion to that of storage portion of a stream and to the ratio of arrival time of stream to that of overland flow.

  • PDF

Effectiveness of Exercise after Lung Cancer Surgery: A Systematic Review in PubMed Database (폐암 수술 후 운동의 효과: PubMed 내 연구에 대한 체계적 문헌고찰)

  • Jerng, Ui Min
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.31 no.1
    • /
    • pp.149-163
    • /
    • 2021
  • Objectives This study is to review the effectiveness of exercise after lung cancer surgery. Methods Relevant randomized controlled trials (RCTs) were searched in PubMed database. The systematic review was conducted through flow diagram. The risk of biases were assessed through the Cochrane guideline. Characteristics and outcomes were extracted from each study. Meta-analyses of forced expiratory volume in one second (FEV1), 6-minute walk test (6MWT), quality of life (QoL), pulmonary complications were conducted. Results 14 RCTs were selected. In meta-analysis, exercise improved FEV1 (mean difference [MD] 0.14; 95% confidence interval [CI] 0.04 to 0.25; p=0.009; I2=55%) and mean change of FEV1 (MD 0.11; 95% CI 0.02 to 0.20; p=0.02; I2=0%). Exercise increased the distance of 6MWT, but there was considerable heterogeneity (MD 45; 95% CI 21.16 to 68.83; p=0.0002, I2=89%). There was no differences in QoL scores by 2 questionnaires (European Organisation for Research and Treatment of Cancer quality of life questionnaire, short form-36). Exercise reduced the duration of hospital stay (MD -3.32; 95% CI -5.27 to -1.36; I2=0%; 2 studies) but not duration of chest tube intubation (MD -1.37; 95% CI -2.81 to 0.06; I2=0%) and incidence of pulmonary complications (pooled risk ratio 0.54; 95% CI 0.23 to 1.30; I2=0%). Conclusions Exercise might reduce the duration of hospital stay after lung surgery. There was not enough evidence to prove improvement of lung function, aerobic capacity, muscle strength, QoL, and decline of pulmonary complications. Low-quality risk of bias, different units or estimation of outcome, different exercise type and duration, heterogeneity among studies make the evidence of effectiveness weak. Future researches are required to redeem these defects.

Assessment of Climate Change Impact on Flow Regime and Physical Habitat for Fish (기후변화가 하천 유황과 어류 물리서식처에 미치는 영향 평가)

  • Hong, Il;Kim, Ji Sung;Kim, Kyu Ho;Jeon, Ho Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.33-44
    • /
    • 2019
  • Due to the recent climate change realization (timing, rainfall pattern changes), the flow regime is changing according to the watershed. The long-term change of flow regime is causing a significant change in structure and function of aquatic ecosystems. However, there is no analysis from the viewpoint of the aquatic ecosystem including flow rate alteration and ecological characteristics as well as the climate change connection in Korea yet. Therefore, We quantitatively assessed the impact of present-future flow regime alteration due to climate change on the Pseudopungtungia nigra habitat in the Mankyung river and floodplain area. As a result, it was confirmed that extreme hydrological conditions such as flood and drought are intensified in the future than the present. Especially, the changes of flow regime characteristics were clarified by comparing and analyzing the magnitude, frequency, duration, rate of change, and by linking flow regime characteristics with physical habitat analysis, it could be suggested that climate change would significantly increase the risk of future ecological changes.

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

Performance Characteristic Anaysis of Micro Hydropower Sites (Micro급 수력발전입지의 성능특성 분석)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.498-501
    • /
    • 2012
  • A methodology to evaluate the performance analysis for micro hydropower sites has been studied. It consists of two main parts; flow duration function which can describe micro hydropower sites and performance analysis to estimate the output characteristics of micro hydropower plants. The output performance characteristics for Magok stream was analyzed, using developed model. Also, primary design specifications such as design flowrate, installed capacity, operational rate and annual electricity production were estimated and dicussed. Additionally, it was found that the developed model in this study is useful tool to estimate feasibility assessment for micro hydropower sites.

  • PDF

Flame Propagation Characteristics of Propane-Air Premixed Mixtures (프로판-공기 예혼합기의 화염전파 과정에 관한 연구)

  • Bae, Choong-Sik
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.2
    • /
    • pp.21-29
    • /
    • 1996
  • Flame propagation characteristics of propane-air mixtures were experimentally investigated in constant-volume combustion chambers. Flame propagation process was observed as a function of mixture strength, initial mixture temperature and initial mixture pressure in quiescent mixtures. A cylindrical combustion chamber and a spherical combustion chamber contain a pair of parallel windows through which optical access into the chamber can be provided. Laser two beam deflection method was adopted to measure the local flame propagation, which gave information on the flame size and flame propagation speed. Pressure development was also measured by a piezoelectric pressure transducer to characterize combustion in quiescent mixtures. Burning velocity was calculated from flame propagation and pressure measurements. The effect of flow on flame propagation was also investigated under flowing mixture conditions. Laser two beam method was found to be feasible in measuring flame propagation of quiescent mixtures. Flame was observed to propagate faster with higher initial mixture temperature and lower initial pressure. Combustion duration was shortened in the highly turbulent flowing mixtures.

  • PDF

Estimation of Instream Flow in Han River (한강에서의 하천유지유량 산정)

  • 오규창;정상만
    • Water for future
    • /
    • v.24 no.1
    • /
    • pp.119-128
    • /
    • 1991
  • This study was focused on establishing the concepts of the instream flow to prevent the problems for the conceptual ambiguity and the difference in the instream flow estimation methods. The average drought flow is defined as the flow required to guarantee the minimum function of the river such as prevention of drying. The environmental control flow is defined as the flow required to control optimal river environment, the flow required for navigation, prevention of sea water-intrusion, protection of river management facilities, conservation of water Quality, fishing, prevention of river mouth closure, control of groundwater level, protection of animals and plants, and landscape. The average drought flow was obtained by flow duration analysis for the natural flows in the Han River at Indo-Bridge gaging station. When considering the 9 factors related to environment conservation, the conservation of water quality was proved to be most important. The pollutants for the river flows were estimated and the water qualities were forecasted. After comparing the water qualities in the future and water quality standards, there quired optimal dilution flow was estimated. The average drought flow and environmental control flow are all non-consumptive flows. Therefore larger flow between them, i.e., Max. (average drought flow, environmental control flow) can be the instream flow. The river management flow can be added to the flows for water utilization in the downstream. The results from this study are expected to be very helpful in the systematic river management on the other main rivers in Korea.

  • PDF

Isolated Working Canine Heart Perfusion Apparatus for Evaluation of Myocardial Protection Methods (심장기능 평가를 위한 견 적출심장 관류장치의 설계)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.246-253
    • /
    • 1988
  • An in vitro model providing with a recirculating perfusion apparatus using an isolated canine heart and its autogenous blood, which was prepared for study of myocardial protection method. This apparatus was easily used by quick connect system and maintained well heart function for about 2 hours. The Langendorff perfusion was initiated for a 10 minute period by introducing perfusate at 37` into the aorta from aortic reservoir located 100 cm above the heart. The isolated perfused working canine heart model was a left heart preparation in which oxygenated perfusion medium [at 37K] entered the cannulated left atrium at a constant flow rate [900ml/ min] under 20 mmHg overflow system and was spontaneously ejected[no electrical pacing] via an cannula against a hydrostatic pressure of 80 cm H2O. During this working period, various indices of cardiac function were measured. The cardiac functions were stable for over 2 hours with perfusion of Krebs-Henseleit solution and autologous blood[1:1] mixture in volume and maintained heart rate ]]3-122/bpm peak systolic pressure 109-113 mmHg, cardiac output 900 ml / min and left atrial mean pressure 8-9 mmHg. In this model, the efficiency of myocardia] protection could be easily measured by means of functional, enzymatic, biochemical and ultrastructural assessment. And also, we believe this model to be a useful assessment screening model of recovery state after long duration of myocardial preservation of donor heart without difficult transplantation procedures.

  • PDF

The Effects of Inspiratory Muscle Training with Chest Expansion on Pulmonary Function, Maximal Inspiratory Pressure, and Gait in Individuals with Stroke (흉곽확장을 병행한 흡기근훈련이 뇌졸중 환자의 폐기능과 최대흡기압력 및 보행지구력에 미치는 영향)

  • Back, Woon-Chang;Kim, Chang-Beom
    • PNF and Movement
    • /
    • v.16 no.3
    • /
    • pp.461-473
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate and compare the effects of inspiratory muscle training with chest expansion exercises on pulmonary function, maximal inspiratory pressure, and gait in individuals with stroke. Methods: The participants in this study included 36 stroke patients. These patients were randomly divided into three groups: an inspiratory muscle training (IMT) with chest expansion (CE) group (n=12), an IMT group (n=12), and a control group (n=12). Participants in the IMT with CE group underwent IMT and CE exercises 5 times per week for 30 minutes over 4 weeks, whereas those in the CE group and the control group received IMT and conventional physical therapy, respectively, for the same duration. The investigator measured the patients' pulmonary function, maximal inspiratory pressure, and gait endurance. Results: After the intervention, the change values for the forced vital capacity (FVC), forced expiratory volume in one second (FEV1), peak expiratory flow (PEF), maximal inspiratory pressure (MIP), and six-minute walk test (6MWT) in the IMT with CE group and the control group were significantly greater than those of the control group (p<0.05). Similarly, after the intervention, the change values of the FVC, FEV1, PEF, MIP, and 6MWT in the IMT with CE group were significantly greater than those in the IMT group (p<0.05). Conclusion: These findings suggest that IMT with CE could be used to increase pulmonary function, maximal inspiratory pressure, and gait endurance in stroke patients.

Long-Term Clinical and Radiologic Outcomes after Stent-Graft Placement for the Treatment of Late-Onset Post-Pancreaticoduodenectomy Arterial Hemorrhage (췌십이지장절제술 후 발생한 후기 출혈에서 스텐트-그라프트를 이용한 치료의 장기적 임상, 영상의학적 결과)

  • Woo Jin Kim;Chang Ho Jeon;Hoon Kwon;Jin Hyeok Kim;Ung Bae Jeon;Suk Kim;Hyung Il Seo;Chang Won Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.600-612
    • /
    • 2021
  • Purpose To evaluate the long-term radiologic and clinical outcomes of stent-graft placement for the treatment of post-pancreaticoduodenectomy arterial hemorrhage (PPAH) based on the imaging findings of stent-graft patency and results of liver function tests. Materials and Methods We retrospectively reviewed the medical records of nine consecutive patients who underwent stent-graft placement for PPAH between June 2012 and May 2017. We analyzed the immediate technical and clinical outcomes and liver function test results. Stent-graft patency was evaluated using serial CT angiography images. Results All stent-grafts were deployed in the intended position for the immediate cessation of arterial hemorrhage and preservation of hepatic arterial blood flow. Technical success was achieved in all nine patients. Eight patients survived after discharge, and one patient died on postoperative day 28. The median follow-up duration was 781 days (range: 28-1766 days). Follow-up CT angiography revealed stent-graft occlusion in all patients. However, serum aspartate aminotransferase or alanine aminotransferase levels in all patients were well below those observed in hepatic infarction cases. Conclusion Stent-graft placement is a safe and effective treatment method for acute life-threatening PPAH. Liver function and distal hepatic arterial blood flow were maintained postoperatively despite the high incidence of stent-graft occlusion observed on follow-up CT.