• 제목/요약/키워드: Flow distribution

검색결과 5,471건 처리시간 0.039초

용접흄 폭로 근로자들의 폐기능에 관한 연구 (Study on the Pulmonary Function in Welding Fume Exposed Workers)

  • 홍영습;김병권;김성률;담도온;김정만;정갑열;김준연
    • Journal of Preventive Medicine and Public Health
    • /
    • 제28권1호
    • /
    • pp.43-57
    • /
    • 1995
  • In order to study the effect of welding fume exposure upon the pulmonary function test, we examined 131 shielded arc welding workers, and 152 $CO_2$ arc welding workers as cases and 177 control workers for their general characteristics, and forced vital capacity (FVC), forced expiratory volume in one second $(FEV_{1.0})$, forced expiratory volume in one second as a percent of FVC $(FEV_{1.0}%)$, and maximal mid-expiratory flow (MMF) were obtained from the spirogram. In shielded arc welding group and $CO_2$ arc welding group, FVC, $FEV_{1.0},\;FEV_{1.0}%$, and MMF were significantly decreased than control group, especially marked in the MMF finding. The distribution of workers below normal range was as follows. in the shielded arc welding group, 2 workers(1.5%) for FVC, 17 workers(13.0%) for $FEV_{1.0}$, 5 workers(3.8%) for $FEV_{1.0}%$, 28 workers(21.4%) for MMF, and in the $CO_2$ arc welding group, 3 workers(2.0%) for FVC, 25 workers(16.4%) for $FEV_{1.0}$, 8 workers(5.3%) for $FEV_{1.0}%$, and 37 workers(24.3%) for MMF, and significant increase by exposure duration was found in MMF. The distribution of workers who had ventilation impairment was as follows: 5 workers(3.8%) for obstructive type, 2 workers(1.5%) for restrictive type in the shielded arc welding group, and 7 workers(4.6%) for obstructive type, 2 workers(1.3%) for restrictive type, and 1 worker(0.6%) was combined type of the $CO_2$ arc welding group. In the respect of these results, the significant pulmonary function and ventilatory impairment were observed in welding fume exposed workers who had not abnormal finding in chest X-ray, and MMF considered as the most sensitive pulmonary function index by welding fume exposure. Therefore even if it is hard to doing pulmonary function test in the first health examination of workers according to the Industrial Safety Health Act in the welding fume exposure workers, it is desirable to consider doing PFT. Also evaluating the ventilation impairment, it is necessary, to observe the change of MMF that marker of effort-independent portion.

  • PDF

상지(上肢) 외전위(外轉位)에서 시행(施行)한 쇄골상(鎖骨上) 상완신경총차단(上腕神經叢遮斷) (Supraclavicular Brachial Plexus block with Arm-Hyperabduction)

  • 임권;임화택;김동권;박오;김성열;오흥근
    • The Korean Journal of Pain
    • /
    • 제1권2호
    • /
    • pp.214-222
    • /
    • 1988
  • With the arm in hyperabduction, we have carried out 525 procedures of supraclavicular brachial plexus block from Aug. 1976 to June 1980, whereas block with the arm in adduction has been customarily performed by other authors. The anesthetic procedure is as follows: 1) The patient lies in the dorsal recumbent position without a pillow under his head or shoulder. His arm is hyperabducted more than a 90 degree angle from his side, and his head is turned to the side opposite from that to be blocked. 2) An "X" is marked at a point 1 cm above the mid clavicle, immediately lateral to the edge of the anterior scalene muscle, and on the palpable portion of the subclavian artery. The area is aseptically prepared and draped. 3) A 22 gauge 3.5cm needle attached to a syringe filled with 2% lidocaine (7~8mg/kg of body weight) and epineprine(1 : 200,000) is inserted caudally toward the second portion of the artery where it crosses the first rib and parallel with the lateral border of the muscle until a paresthesia is obtained. 4) Paresthesia is usually elicited while inserting the needle tip about 1~2 em in depth. If so, the local anesthetic solution is injected after careful aspiration. 5) If no paresthesia is elicited, the needle is withdrawn and redirected in an attempt to elicit paresthesia. 6) If, after several attempts, no paresthesia is obtained, the local anesthetic solution is injected into the perivascular sheath after confirming that the artery is not punctured. 7) Immediately after starting surgery, Valium is injected for sedation by the intravenous route in almost all cases. The age distribution of the cases was from 11 to 80 years. Sex distribution was 476 males and 49 females (Table 1). Operative procedures consisted of 103 open reductions, 114 skin grafts combined with spinal anesthesia in 14, 87 debridements, 75 repairs, i.e. tendon (41), nerve(32), and artery (2), 58 corrections of abnormalities, 27 amputations above the elbow (5), below the elbow (3) and fingers (17), 20 primary closures, 18 incisions and curettages, 2 replantations of cut fingers. respectively (Table 2). Paresthesia was obtained in all cases. Onset of analgesia occured within 5 minutes, starting in the deltoid region in almost all cases. Complete anesthesia of the entire arm appeared within 10 minutes but was delayed 15 to 20 minutes in 5 cases and failed in one case. Thus, our success rate was nearly 100%. The duration of anesthesia after a single injection ranged from $3\frac{1}{2}$ to $4\frac{1}{2}$, hours in 94% of the cases. The operative time ranged from 0.5 to 4 hours in 92.4% of the cases(Table 3). Repeat blocks were carried out in 33 cases when operative times which were more than 4 hours in 22 cases and the others were completed within 4 hours (Table 4). Two patients of the 33 cases, who received microvasular surgery were injected twice with 2% lidocaine 20 ml for a total of $13\frac{1}{2}$ hours. The 157 patients who received surgery on the forearms or hands had pneumatic tourniquets (250 torrs) applied without tourniquet pain. There was no pneumothorax, hematoma or phrenic nerve paralysis in any of the unilateral and 27 bilateral blocks, but there was hoarseness in two, Horner's syndrome in 11 and shivering in 7 cases. No general seizures or other side effects were observed. By 20ml of 60% urcgratin study, we confirm ed the position of the needle tip to be in a safer position when the arm is in hyperabduction than when it is in adduction. And also that the humoral head caused some obstraction of the distal flow of the dye, indicating that less local anesthetic solution would be needed for satisfactory anesthesia. (Fig. 3,4).

  • PDF

프랜차이즈 기업의 지식경영 전략 : 파리바게뜨 사례를 중심으로 (Knowledge Management Strategy of a Franchise Business : The Case of a Paris Baguette Bakery)

  • 조준상;김보영
    • 유통과학연구
    • /
    • 제10권6호
    • /
    • pp.39-53
    • /
    • 2012
  • 기업에 경쟁우위를 가져다주는 많은 자원들 중에서 특히 지식(knowledge)은 생산 활동을 위해 다른 자원을 변화시키거나 확보할 수 있도록 만드는 중요한 자원으로 알려져 있다. 이러한 조직 내 지식은 다양한 형태로 존재하고, 다양한 장소나 개인에게 산재해 있기 때문에, 이를 통합하고 체계적으로 활용하기 위한 기업의 전사적 관리 활동이 필요하다. 특히 지식관리시스템(KMS: knowledge management systems)은 조직 내 지식을 창조하고, 공유하고, 적절히 사용함으로써 지식관리 프로세스를 지원하고 조직이 가진 지식자원의 가치를 극대화하여 기업의 학습조직화와 성과 증진을 이끌 수 있다. 이에 본 연구는 국내 대표적인 프랜차이즈 기업인 파리바게뜨의 성공적인 지식관리시스템운영 사례를 분석하여 프랜차이즈 기업들의 지식경영을 강화 및 지식관리시스템(KMS) 구축과 개선을 위한 구체적인 시사점을 제안하고자 하였다. 결과적으로 최고경영층의 관심과 지원, 능동적인 지식 공유와 활용을 위한 학습조직 문화, 네트워크 활성화를 통한 지식의 변환, 정보기술, 지식경영의 내재화를 위한 촉진제도와 보상이라는 5가지 주요 요인이 프랜차이즈 기업의 지식관리시스템의 성공적 운영을 위해 반드시 고려되어야 하는 요인임을 밝혀낼 수 있었다.

  • PDF

보 개방 후 노출된 금강 모래톱에서 하천 식생의 공간 분포와 천이 (Spatial Distribution and Successional Changes of Riparian Vegetation on Sandbars Exposed after Watergate-Opening of Weirs in the Geumgang River, South Korea)

  • 이철호;김휘래;조강현
    • Ecology and Resilient Infrastructure
    • /
    • 제9권3호
    • /
    • pp.194-205
    • /
    • 2022
  • 하천에서 유사의 이동 및 퇴적으로 형성된 모래톱은 특이한 생물의 서식과 심미적 경관 측면에서 중요한 서식처이다. 본 연구는 보 상류에서 수문 개방에 의하여 노출된 모래톱에서 초기 식생의 발달과 그 분포를 확인하여 시간 경과에 따른 식생변화 과정을 파악하고자 하였다. 보 수문 개방 시기가 다른 금강의 3개 보 개방 구간과 보 운영에 영향을 받지 않는 대조 구간에서 보 개방 후 노출된 모래톱에서 식물군집 구조와 공간 분포의 변화를 파악하고 모래톱의 노출 기간에 따른 식물 군집 구조의 변화를 조사하였다. 금강의 보 상류구간에서 수문 개방으로 기존 홍수터 면적의 33% 이상의 면적에 해당하는 모래톱이 새롭게 형성되었다. 노출된 모래톱에는 1년생 중생식물, 다년생 수생식물, 다년생 습생식물, 아교목, 교목 군집에 속하는 9개 식물군집이 분포하였다. 모래톱의 노출 기간이 길어 짐에 따라서 나지 모래톱, 1년생 초본식물, 다년생 수생식물 군집의 면적은 감소하였고, 다년생 습생식물, 아교목, 교목 군집의 면적은 증가하였다. 하천 모래톱에서 시간 경과에 따른 식생의 변화는 수위 하강 전 수중 서식처의 조건과 물 흐름에 의한 물리적 교란의 정도에 따라서 3가지 천이 유형으로 구분할 수 있었다. 즉 모래톱의 천이과정은 1) 수생식물로부터 시작하는 '정수지 천이', 2) 일년생 습생 초본식물로부터 시작하는 '유수지 천이', 3) 버드나무류로 시작하는 '버드나무류 천이'로 구분할 수 있었다. 따라서 금강의 보 구간에서 하천 서식처 및 경관의 변화를 체계적으로 관리하기 위하여 모래톱에서의 식생 천이계열을 반영하여야 할 것으로 판단된다.

하천 관리를 위한 원격탐사 자료 기반 식생 분류 기법 (Vegetation classification based on remote sensing data for river management)

  • Lee, Chanjoo;Rogers, Christine;Geerling, Gertjan;Pennin, Ellis
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.6-7
    • /
    • 2021
  • 하천에서의 식생 활착은 지형, 생태, 수리학 등의 학문 분야 뿐만 아니라 하천 관리 실무에서도 중요한 이슈 중에 하나로서 하천 식생 문제는 홍수 관리와 생태계 보전이라는 상반되는 가치의 조화에 직결된다. 국내에서는 2000년대 이후 댐 하류 조절하천, 부영화된 소규모 지류하천, 4대강 사업 대상지 고수부지 등 다양한 조건에서 하천 식생 활착과 육역화 문제가 지속적으로 제기되어 왔다. 이러한 배경에서 본 연구에서는 하천 내의 식생 분포를 원격탐사 자료를 기반으로 분류하는 기법을 제안하고 이를 내성천에 적용한 결과를 제시하였다. 내성천은 2014년부터 최근까지 지속적으로 식생 활착이 발생하여 하천 경관이 변화한 대표적인 사례 하천이다. 원격탐사 자료는 유럽항공우주국(ESA)에서 운영 중이며, Google Earth Engine에서 제공하는 Sentinel 1, 2 위성 영상을 사용하였다. 지상 참값(ground truth)으로는 수역, 사주, 초본, 목본 등을 포함한 8가지 유형으로 구분되어 있는 2016년 내성천 지표 피복 자료를 사용하였다. 분류를 위한 방법은 머신러닝 알고리듬의 하나인 랜덤 포레스트 분류 기법을 사용하였으며, 미리 선정된 10개 폴리곤 영역으로부터 1,000개의 표본을 추출하여 1/2씩 나누어 훈련 및 검증 자료로 사용하였다. 검증 자료 기반의 정확도는 82~85 %로 나타났다. 훈련을 통해 수립한 모형을 2016~2020년 자료에도 적용하여 연도에 따른 식생역의 변화 과정을 제시하였다. 본 논문의 기술적 한계와 개선 방안을 고찰하였다. 이 기법은 정량적인 식생 분포를 제공함으로써 하천에서의 홍수위 계산, 식생-수리모델링 등의 기술 분야 뿐만 아니라 간벌이나 하천 식생 회춘 유도(rejuvenation)과 같은 식생의 실무적 관리 측면에서도 활용도가 클 것으로 판단된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교 (Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung)

  • 이재호;정희순;심영수
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권4호
    • /
    • pp.555-568
    • /
    • 1995
  • 연구배경: 폐확산능은 산소를 이용하여 측정하는 것이 가장 생리적이지만 폐모세혈의 산소분압측정이 어려워 임상에서는 일산화탄소를 이용하여 측정하고 있으며, 단회호흡(single-breath)폐확산능검사법이 가장 널리 사용되고있는 방법이다. 그러나 총폐용량까지 흡기한후 10초간 숨을 참는 과정을 기침, 호흡곤란 등이 있는 환자로선 수용하기 곤란하므로 이러한 과정없이 낮은 유량의 일회호기만을 필요로 히는 호흡내(intra-breath)폐확산능검사법이 고안되었다. 본 연구에서는 단회호흡법과 호흡내법으로 측정한 폐확산능간에 유의한 차이가 있는지 그리고 차이가 있다면 어떤 인자가 영향을 미치는지를 알아보고자 하였다. 방법: 특정질환과 무관하게 임의로 73명을 선택하고 유량-용적곡선 검사를 3회 시행한후 노력성 폐활량(FVC)과 1초간 노력성호기량($FEV_1$)의 합이 가장 큰 검사에서 노력성폐활량, 1초간 노력성호기량, 1초간 노력성호기량의 노력성 폐활량에 대한 비($FEV_1$/FVC)를 구했다. 폐확산능은 5분간격으로 각각 3회씩 단회호흡법과 호흡내법으로 측정하였으며, 선형적 상관분석으로 어떤 인자가 두 방법간의 폐확산능의 차[단회호흡법과 호흡내법에 의한 각각의 폐확산능의 차이의 평균치(mL/min/mmHg)]에 영향을 미치는지를 평가하여 다음과 같은 결과를 얻었다. 결과: 1) 단회호흡법 및 호흡내법 모두 검사내 재현성은 우수하였다. 2) 단회호흡법과 호흡내법으로 측정한 폐확산능간에는 전체적으로 유의한 상관관계가 있었지만, 두 방법의 측정치간에는 의미있는 치아가 있었다($1.01{\pm}0.35ml/min/mmHg$, p<0.01). 3) 단회호흡법과 호흡내법간의 폐확산능의 차이는 노력성폐활량과는 상관관계가 없었지만, 1초간 노력성호기량, $FEV_1$/FVC 및 환기배분의 지표인 메탄농도의 기울기와는 유의한 상관관계가 있었고 다중상관분석결과 $FEV_1$/FVC에 의한 영향이 가장 컸다(r=-0.4725, p<0.01). 4) 단회호흡법과 호흡내법간의 폐확산능의 차이와 $FEV_1$/FVC를 도식화하면 두 방법간의 폐확산능의 차이는 $FEV_1$/FVC가 50~60%인 구간에서 두 군으로 분리됨을 알수 있으며, $FEV_1$/FVC가 60% 이상에서는 두방법간에 유의한 차이가 없으나($0.05{\pm}0.24ml/min/mmHg$, p>0.1) 60% 미만에서는 유의한 차이가 있었다($-4.65{\pm}0.34ml/min/mmHg$, p<0.01). 5) 메탄농도의 기울기가 정상범위인 2%/L이내에선 단회호흡법과 호흡내법의 폐확산능이 모두 $24.3{\pm}0.68ml/min/mmHg$로 측정방법에 따른 차이가 없지만 2%/L를 초과한 경우에는 단회호흡법에 의한 폐확산능이 $15.0{\pm}0.44ml/min/mmHg$ 호흡내법에 선 $11.9{\pm}0.51ml/min/mmHg$로 두 방법간에 유의한 차이가 있었다(p<0.01). 따라서 $FEV_1$/FVC가 60% 미만일때는 호흡내법으로 측정한 폐확산능이 단회호흡법보다 의미있게 낮은 값을 보이는데, 그 이유는 주로 환기배분의 장애로 추정되지만 폐확산능 이 단회호흡법에서 과대평가되거나 폐확산능의 감소가 호흡내법에서 더 예민하게 나타 났을 가능정도 배제할수 없다. 결론: 73명을 대상으로 폐확산능을 단회호흡법과 호흡내법으로 측정해본 결과 호흡내법은 검사의 재현성도 우수하고 폐기능이 정상이거나 제한성 장애, 그리고 경도의 폐쇄성장애가 있는 경우에는 단회호흡법을 대체해서 사용할수 있지만, 중등도 이상의 폐쇄성장애가 있는 경우에는 단회호흡법보다 유의하게 낮은 검사치를 보였다. 호흡내법과 단회호흡법에 의한 폐확산능의 차이가 호흡내법이 단회호흡법에 비해 폐확산능의 감소를 예민하게 나타내주는 것인지 혹은 환기의 불균형에 의한 영향을 많이 받아서인지는 연구가 더 필요할 것이다.

  • PDF

영산강 하구의 방류와 강우의 규모 및 빈도 상관성 분석 (Relationships on Magnitude and Frequency of Freshwater Discharge and Rainfall in the Altered Yeongsan Estuary)

  • 류호상;이관홍
    • 한국해양학회지:바다
    • /
    • 제16권4호
    • /
    • pp.223-237
    • /
    • 2011
  • 하구둑으로 인해 담수의 공급이 간헐적으로 발생하는 영산강 하구에서는 담수의 방류가 하구의 유동패턴, 염분농도의 변이, 영양염 공급 등 하구환경과 생태계 반응을 주도하는 요인이다. 담수의 방류는 유역의 강우조건에 영향을 받으므로 담수의 방류시기 및 규모를 파악하기 위해서는 담수방류를 유발하는 강우조건과 강우-방류간 상관관계에 대한 이해가 필요하다. 또한 담수방류가 하구에 미치는 영향을 평가하기 위해서는 방류의 규모와 더불어 빈도에 대한 고려가 필수적이다. 이 연구는 영산강 하구역의 담수방류를 예측하고 평가하는 도구로서 영산강 하구둑의 담수 방류자료를 대상으로 강우에 보다 직접적으로 반응하는 극치방류의 확률분포함수를 파악하고 극치방류를 유발하는 강우조건을 판별하여 극치방류를 유발하는 강우와 극치방류 간의 빈도-규모 관계식을 도출하는 데 목적을 두었다. 13.7년(1997.1.1-2010.8.31)간의 일방류량 자료에 대하여 일연속방류를 분석의 기본단위인 방류이벤트로 정의하되 4일 이상의 일연속방류의 경우는 방류패턴에 토대를 둔 이벤트 분리 알고리듬을 적용하여 개별 이벤트를 식별하였다. 총 529건의 방류 이벤트에 대하여 14년간의 연 최고치 중 최솟값에 해당하는 133,656,000 $m^3$을 기준으로 극치방류이벤트를 선별하고 부분시계열 빈도분석법을 적용하여 극치방류의 확률분포함수가 Weibull(k=1.4)함수를 따름을 확인하였다. 극치방류를 기준으로 대비되는 강우 l일전 3일합 강우량이며 최솟값은 50.98 mm인 것으로 나타났다. 이 기준에 따라 추출된 방류유발기능 강우군은 총 102건으로 극치방류이벤트의 수보다 많았다. 정준판별분석을 통해 3일합 강우량 이외에 관리수위대비(-1.35 m EL.) 하구호 수위가 방류유발 강우를 규정하는 중요한 요소라는 점과 방류유발가능 강우군을 선별하는 임계값을 104mm로 재조정할 경우 3일합 강우량만으로 방류유발 강우를 규정할 수 있음을 확인하였다. 극치방류 유발 강우만을 대상으로 강우-방류 관계식을 수립한 결과 3일합-강우량($\overline{r_{3day}}$), 3일합-강우량 재현주기($T_{r3}$), 방류량(Discharge, D), 방류량 재현주기($T_d$)의 관계는 $D=1.111{\times}10^8+1.677{\times}10^6{\overline{r_{3day}}$, (${\overline{r_{3day}}{\geqq}104$), $T_d=1.326T^{0.683}_{r3}$, $T_d=0.117{\exp}[0.0155{\overline{r_{3day}}]$로 나타났다. 100년 주기 3일합 강우(357mm)에 의해 유발되는 방류량은 영산강 하구둑 방류량의 재현주기는 30.8년 정도이며 그 양은 $7.0979{\times}10^8m^3$이다. 담수방류의 재현주기 및 재현주기에 기초한 강우-방류 관계식은 영산강 하구역을 비롯하여 인위적으로 담수의 방류가 조절되는 하구역에서 담수의 영향을 평가하고 예측하는 데 기여할 수 있을 것이다.

남극 브랜스필드 해협 중앙분지의 지체구조 및 석유부존 가능성 (Tectonic Structures and Hydrocarbon Potential in the Central Bransfield Basin, Antarctica)

  • 허식;김예동;정대교;진영근;남상헌
    • 한국석유지질학회지
    • /
    • 제5권1_2호
    • /
    • pp.9-15
    • /
    • 1997
  • 남극 브랜스필드 해협 중앙분지에서 획득한 다중채널 탄성파탐사 자료를 중심으로 자료처리를 수행하여 전반적인 해저지형, 지층 및 지체구조를 해석하였다. 브랜스필드 중앙분지는 확장중심축을 경계로 해저지형, 화산분출물 및 단층분포, 기반암의 형태가 크게 달라진다. 급격한 경사를 보이는 북쪽 대륙붕은 낙차가 크고 연속성이 좋은 한 개의 긴 정단층 (북동-남서 방향)으로 구성되는 반면, 완만한 경사의 남쪽 대륙붕은 여러 개의 정단층들이 거의 일정한 간격으로 조밀하게 배열된 분포를 보여, 분지가 북서-남동 방향의 확장성 지구조운동에 의해 형성되었음을 나타낸다. 화산분출물 분포를 보면 확장중심과 그 근처에 선형의 대규모 분출물이 형성되어 있고, 양쪽 대륙붕 상단에는 소규모 분출물들이 존재한다. 이들 단층과 분출물은 지하 깊숙이 존재하는 트랜스퍼 (transfer)단층의 영향을 받아 북서-남동 방향으로 수평이동 되었으며 기반암의 형태 및 퇴적 양상을 변화시키고 있다. 퇴적층은 확장중심축 근처에서는 얇게 피복되어 있으나 분지 중심에서 대륙붕단까지는 쐐기 형태로 두껍게 퇴적되어 있고, 대륙붕에서는 화산분출물이 있는 곳을 제외하고는 대체로 평행하게 퇴적되어 있다. 이와 같이 분지의 형태와 퇴적층의 분포는 밀접한 관련성을 보이며 확장중심축을 경계로 퇴적환경에 커다란 변화가 있었음을 알수 있다. 브랜스필드 분지는 신생대 후기에 형성된 젊은 분지이지만 유기물이 풍부한 지질환경과 활발한 지구조운동에 결부된 높은 지열류량으로 인해 탄화수소를 충분히 성숙시킬 수 있는 조건을 가지고 있을 것으로 사료된다./투스칼루사(Tuscaloosa) 사암층, 테일러(Taylor) 나바로(Navarro) 사암층과 오스틴(Austin) 백악 및 탄산염암층이 있다. 이 저류암층에 탄화수소를 공급했던 근원암층으로는 경사방향 하부의 셰일층이, 그리고 덮개암층은 경사방향 상부의 계일층이 그 역할을 담당했던 것으로 해석된다. 뗘악기 하부와 상부 퇴적층의 주요 트랩(trap)으로는 완만한 기둥형(pillow)으로부터 복잡한 다이아피어(diapir) 형태의 암염층 관련 배사구조와 하단 단층블록위에 놓여 있으며 롤오버(rollover) 배사구조를 갖는 성장단층이 있다. 투수 장애(permeability barrier), 상부 경사방향으로 첨멸하는 사암체(up-dip pinch-out sand body깥 침식부정합면(unconformity truncation)도. 걸프만 석유부존에 중요한 역할을 한 트랩들이다. 백악기의 주요한 저류암층들은 범세계 해수면곡선의 하강시기와 잘 일치하고 있는데 이는 백악기동안 형성된 걸프만의 퇴적층서가 범세계 해수면곡선을 전반적으로 잘 반영하고 있음을 의미한다. 즉 퇴적작용을 주로 지배하는 세 즌요 변수인 지구조적인 분지의 침강운동,퇴적물의 공급,해수면 변동오그÷중에서 해수면 변동요소가 이 시기동안 가장 중요한 역할을 했음을 의미한다.

  • PDF