• Title/Summary/Keyword: Flow characteristic

검색결과 1,942건 처리시간 0.031초

Investigation of characteristic values in TDR waveform using SHapley Additive exPlanations (SHAP) for dielectric constant estimation during curing time

  • Won-Taek Hong;WooJin Han;Yong-Hoon Byun;Hyung-Koo Yoon
    • Smart Structures and Systems
    • /
    • 제34권1호
    • /
    • pp.25-32
    • /
    • 2024
  • As materials cure, the internal electrical flow changes, leading to variations in the dielectric constant over time. This study aims to assess the impact of voltage values extracted from time domain reflectometry (TDR) waveforms, measured during the curing of materials, on predicting the dielectric constant. The experiments are conducted over a curing period ranging from 60 to 8640 minutes, with 30 TDR trials. From the measured waveforms, values of V0, V1, V2, Vf, and Δt are deduced. Additionally, curing time is included as an input variable. Groups A and B are distinguished based on the presence or absence of Δt, indicating a physical relationship between Δt and the dielectric constant. The dielectric constant is set as the output variable. The SHapley Additive exPlanations (SHAP) algorithm is applied to the compiled data. The results indicate that Δt and V1 are the most influential input variables in both Group-A and Group-B. The study also presents the distribution of SHAP values and interacts SHAP values to infer the interrelationships among the input variables. To validate the reliability of these findings, the partial dependence (PD) algorithm is applied to estimate the marginal effects of each input variable, with outcomes closely aligning with those of the SHAP algorithm. This research suggests that understanding the contributions and proportional relationships of each input variable can aid in interpreting the relationships among various material properties.

지방첨가원에 따른 젖소의 반추위 발효성상 미생물 합성 효율 및 영양소 소화율 영향 연구 (Effects of Different Fat Sources on Fermentative Characteristics and Microbial Efficiency in the Rumen, and Nutrients Digestibility of Dairy Cows)

  • 최낙진;맹원재;김현진;이홍구;하종규
    • Journal of Animal Science and Technology
    • /
    • 제46권3호
    • /
    • pp.347-354
    • /
    • 2004
  • 사료 지방의 종류에 따른 반추위 내 발효성상, 미생물 합성 효율 및 영양소 소화율을 조사하기 위하여 반추위와 십이지장에 누관이 설치된 4마리의 홀스타인 젖소를 4 ${\times}$ 4 라틴 방각법 대사실험을 수행하였다. 공시축들은 조사료 60% 및 농후사료 40% 비율의 완전혼합사료 형태로 급여하였다. 농후사료 내 지방원으로써 Megalac(MEG), 포름알데히드 처리 아마 종실(LIN), 어유와 포름알데히드 처리 아마종실 혼합(MIX; 50 : 50, oil basis), 그리고 농후사료 내 지방을 첨가하지 않고 아마유를 십이지장에 하루 500g 주입한 것(OIL)을 포함하여 총 4개의 처리구를 두었다. 반추위 pH는 OIL 처리구에서 가장 낮았으나(P < 0.05), Ammonia N 농도는 처리구들간 통계적 유의차가 없었다. Total VFA, acetate, propionate, iso-butyrate 및 iso-valerate 농도 또한 처리구들간 통계적 유의차이가 없었다. 반면에 butyrate와 valerate는 OIL 처리구에서 가장 높았고, MEG 처리구에서 가장 낮았다(P < 0.05). DM, OM, NDF 및 ADF 섭취량은 OIL 처리구에서 가장 낮았다(P < 0.01). 그러나, 십이지장으로의 영양소들의 flow, 반추위와 전장 소화율은 처리구들간에 통계적 유의차이가 없었다. 질소 (N) 섭취량은 OIL 처리구에서 가장 낮았다(P < 0.01). 십이지장으로의 total N, nonammonia N 및 microbial N flow는 처리구들간 통계적 유의차이가 없었다. 그리고, 미생물합성효율, ammonia N 및 total N의 반추위 및 전장 소화율 또한 처리구들간에 통계적 유의차이가 없었다. 따라서, 본 실험결과는 사료 내 6% 정도의 지방원료 첨가는 형태와 종류에 상관없이 반추위 발효성상, 미생물 합성 효율, 반추위 및 전장 내 영양소 이용효율을 감소 시키지 않음을 나타내고 있다.

기류 가역성 평가에 있어서 최대호기유속 측정의 유용성 (Validity of Peak Expiratory Flow for Assessing Reversible Airflow Obstruction)

  • 최원일;곽진호;권두영;한승범;전영준
    • Tuberculosis and Respiratory Diseases
    • /
    • 제48권4호
    • /
    • pp.522-529
    • /
    • 2000
  • 목 적 : 최대호기유속 측정도 $FEV_1$과 함께 기도폐색의 정도를 평가할 수 있으며 기도폐색의 가역성을 평가하는 것은 기도폐쇄질환 환자들의 진단 및 치료에 중요하다. 최대호기유속은 $FEV_1$에 비해 측정이 간단하며 쉽고 빠르게 검사할 수 있는 장점이 있어 1차 진료기관에서도 쉽게 이용할 수 있다. 그러나 최대호기유속으로 기류 가역성을 평가한 연구는 매우 적다. 이에 천식 및 만성폐쇄성폐질환 환자들에게서 최대호기유속과 $FEV_1$으로 기류 가역성올 비교 평가하여 1차 진료기관에서 최대호기유속을 측정함으로써 기류 가역성을 평가하는데 기준을 마련하고자 본 연구를 시행하였다. 방 법 : 본 연구는 호흡곤란, 기침 및 천명을 주소로 계명대학교 동산병원 호흡기내과를 방문한 환자들 중 천식 및 만성폐쇄성폐질환으로 진단 받은 80명의 환자들을 대상으로 조사하였다. 베타-2 교감신경작용제(salbutamol) 흡입 직전과 15분 후 측정한 $FEV_1$의 추정정상치가 12% 이상 증가하고 노력성폐활량 또는 $FEV_1$의 절대값이 200ml 이상 증가한 경우를 기류가역성이 있는 것으로 정의하였다. 최대호기유속의 가역성은 베타-2 교감신경작용제 사용 후 절대값의 변화(1/min)로 표현하였으며 최대호기유속의 절대값의 변화에 따른 기류폐색의 가역성 평가에 대한 민감도, 특이도, 양성예측율과 음성예측율을 구하였다. 결 과 : 대상환자 80명중 36명(45%)에서 기류 가역성이 있었다. 폐활량측정법으로 기류 가역성이 증명된 환자에서 최대호기유속으로 기류 가역성을 평가하여서 최대호기유속의 민감도, 특이도, 양성예측을 그리고 음성예측율을 구하였을때 기저치보다 30 l/min 이상 증가한 경우에 가장 높게 관찰되었고 민감도 72.2%, 특이도 72.7%, 양성예측율 68.4% 그리고 음성예측율은 76.2%로 관찰되었다. 결 론 : 이상의 결과로 베타-2 교감신경작용제 사용 후 최대호기유속의 절대값의 변화는 기류 가역성을 평가하는데 간편하고 효율적인 방법으로 생각된다.

  • PDF

설비공학 분야의 최근 연구 동향: 2011년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2011)

  • 한화택;이대영;김서영;최종민;백용규;김수민
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.521-537
    • /
    • 2012
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2011. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of fluid machinery and fluid flow, thermodynamic cycle, and new and renewable energy. Various topics were presented in the field of fluid machinery and fluid flow. Research issues mainly focused on the rankine cycle in the field of thermodynamic cycle. In the new and renewable energy area, researches were presented on geothermal energy, fuel cell, biogas, reformer, solar water heating system, and metane hydration. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, nanofluids and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer above liquid helium surface in a cryostat, methane hydrate formation, heat and mass transfer in a liquid desiccant dehumidifier, thermoelectric air-cooling system, heat transfer in multiple slot impinging jet, and heat transfer enhancement by protrusion-in-dimples. In the area of pool boiling and condensing heat transfer, researches on pool boiling of water in low-fin and turbo-B surfaces, pool boiling of R245a, convective boiling two-phase flow in trapezoidal microchannels, condensing of FC-72 on pin-finned surfaces, and natural circulation vertical evaporator were actively performed. In the area of nanofluids, thermal characteristics of heat pipes using water-based MWCNT nanofluids and the thermal conductivity and viscosity were measured. In the area of industrial heat exchangers, researches on fin-tube heat exchangers for waste gas heat recovery and Chevron type plate heat exchanger were implemented. (3) Refrigeration systems with alternative refrigerants such as $CO_2$, hydrocarbons, and mixed refrigerants were studied. Heating performance improvement of heat pump systems were tried applying supplementary components such as a refrigerant heater or a solar collector. The effects of frost growth were studied on the operation characteristic of refrigeration systems and the energy performance of various defrost methods were evaluated. The current situation of the domestic cold storage facilities was analyzed and the future demand was predicted. (4) In building mechanical system fields, a variety of studies were conducted to achieve effective consumption of heat and maximize efficiency of heat in buildings. Various researches were performed to maximize performance of mechanical devices and optimize the operation of HVAC systems. (5) In the fields of architectural environment and energy, diverse purposes of studies were conducted such as indoor environment, building energy, and renewable energy. In particular, renewable energy and building energy-related researches have mainly been studied as reflecting the global interests. In addition, various researches have been performed for reducing cooling load in a building using spot exhaust air, natural ventilation and energy efficiency systems.

도로변 공원의 공간조성유형에 따른 초미세먼지 분포 특성 - 부산시 송상현광장을 사례로- (Characteristics of Particulate Matter 2.5 by Type of Space of Urban Park - Focusing on the Songsanghyeon Plaza in Busan -)

  • 안로사;홍석환
    • 한국조경학회지
    • /
    • 제49권6호
    • /
    • pp.37-48
    • /
    • 2021
  • 본 연구는 도심 내 주요 초미세먼지(PM2.5) 발생원인 도로 인근에 조성된 도시공원을 대상으로 도시공원 내부 공간조성유형에 따라 PM2.5의 농도변화를 분석하여 특성을 살펴보고자 하였다. 연구대상지는 부산시 진구 도심 내 12차선의 도로 중심부에 광장형 공원형태로 조성된 송상현광장으로 선정하였으며, 공원의 공간조성유형은 토지피복유형과 식생구조에 따라 도로변 광장(A), 선큰광장(B), 도로 경계부 다층식재지(C), 교목 하부(D), 잔디광장(E)으로 총 5가지로 구분하였다. PM2.5는 초미세먼지 등급별 국가예보에 따라 좋음일, 보통일, 나쁨일 3일씩 총 9회 측정한 결과를 바탕으로 평균비교 분석을 수행하였다. PM2.5 좋음일 기준으로 송상현광장 내 공간조성유형별 농도는 D, E < B, C < A 순으로 통계적 유의성이 있었다. PM2.5 보통일과 나쁨일 기준은 D, E < A, B, C 순으로 유의하였다. 공간조성유형별 송상현광장 내 PM2.5 농도 특성은 인근 차도로부터 확산되는 PM2.5의 대기의 흐름의 영향이 큰 것으로 판단되었다. 차도와 15m 거리에 위치해 있는 A와 C의 경우 PM2.5 농도가 높았으나, B는 도로로부터 40m 거리에 떨어져 있는 PM2.5 농도가 높았다. 이는 B는 외벽구조로 둘러싸여 공간 내부의 공기순환이 느려 상대적으로 대기가 확산되지 못하는 것으로 판단되었다. D와 E의 경우 C의 공간조성유형을 통해 대기의 흐름이 차단된 후 공원 내부에서 대기의 흐름이 원활한 구조여서 PM2.5 농도가 상대적으로 낮은 것으로 판단하였다.

토양중(土壤中) 비소(砒素)의 행동(行動)과 수도(水稻)의 비소흡수(砒素吸收)에 의(依)한 피해(被害) 생리(生理) 생태(生態)에 관한 연구(硏究);IV. 수경시험(水耕試驗)에서 비소처리(卑小處理)가 수도(水稻)의 증산(蒸散), 기공저항성(氣孔抵抗性) 및 엽(葉)의 온(溫), 습도(濕度)에 미치는 영향(影響) (Behaviors of Arsenic in Paddy Soils and Effects of Absorbed Arsenic on Physiological and Ecological Characteristic of Rice Plant;IV. Effect of As content in water on transpiration, stomatal resistance, temperature and humidity in the leaves of rice plant)

  • 이민효;임수길;김복영
    • 한국환경농학회지
    • /
    • 제6권2호
    • /
    • pp.39-45
    • /
    • 1987
  • 비소처리(砒素處理)에 의(依)한 수도(水稻)의 수분흡수양상(水分吸收樣相)을 구명(究明)하기 위하여 배양액(培養液)에 비소(砒素)를 0, 1, 5, 10, 15ppm 처리(處理)하고 수도(水稻)를 수경재배(水耕栽培)하여 비소처리별(砒素處理別) 수도(水稻)의 증산량(蒸散量)과 엽(葉)의 기공저항성(氣孔抵抗性), 공기유량(空氣流量), 엽(葉)의 온(溫), 습도(濕度) 및 식물체(植物體)의 비소함량등(砒素含量等)을 조사(調査)하여 얻어진 결과(結果)는 다음과 같다. 1. 증산량(蒸散量)은 배양액중(培養液中) 비소농도(砒素濃度)가 높아질수록 현저히 감소(減少)되었다. 2. 배양액중(培養液中) 비소농도(砒素濃度)가 높아질수록 엽(葉)의 기공저항성(氣孔抵抗性) 및 엽온(葉溫)은 높아지나 공기유량(空氣流量), 증산율(蒸散率) 및 엽내습도(葉內濕度)는 낮아졌다. 3. 엽(葉)의 공기유량(空氣流量), 증산율(蒸散率) 및 기공저항성(氣孔抵抗性)은 뿌리 및 경엽중(莖葉中) 비소함량(砒素含量)과 높은 상관(相關)을 나타내었으며 이들중 공기유량(空氣流量) 및 증산율(蒸散率)은 뿌리중 비소함량(砒素含量)과 기공저항성(氣孔抵抗性)은 경엽중(莖葉中) 비소함량(砒素含量)과 더 높은 상관(相關)을 나타내었다. 4. 수도(水稻)의 초장(草長), 분벽수(分蘗數), 엽폭(葉幅), 호중(蒿重) 및 근중(根重)은 배양약중(培養液中) 비소농도(砒素濃度)가 높아질수록 현저히 감소(減少)되었다. 5. 수도(水稻)에 대(對)한 비소피해증상(砒素被害症狀)은 뿌리가 갈변(褐變)하고 잎이 말리며 엽(葉)의 선단(先端)과 가장자리가 괴사(壞死)되었다.

  • PDF

말뚝으로 지지된 성토지반의 파괴형태 (Failure Modes in Piled Embankments)

  • 홍원표;윤중만;서문성
    • 한국지반공학회논문집
    • /
    • 제15권4호
    • /
    • pp.207-220
    • /
    • 1999
  • 성토지지말뚝으로 지지된 연약지반상 성토지반의 파괴형태를 조사하기 위하여 실내모형실험이 실시되었다. 성토지지말뚝은 성토하중의 지지효과를 증대시키기 위하여 줄말뚝의 형태로 설치하였으며 줄말뚝의 두부는 지중보 형태의 말뚝캡보로 서로 연결시켰다. 이 말뚝캡보는 성토지반의 장축방향에 직각이 되도록 연결시켰다. 사용모래로는 주문진 표준사를 사용하였으며 성토지반의 변형거동을 관찰하기 위하여 흑연가루로 채색한 모래층과 원래의 모래층을 서로 3mm두께로 번갈아 성토하여 줄무늬를 만들었다. 실험중 촬영한 사진분석으로 부터 성토지반의 파괴형태는 지반아칭파괴와 펀칭전단파괴의 두가지임을 알 수 있다. 성토지반내 어떤 파괴형태가 발생될 것인가는 성토고와 말뚝캡보 사이의 간격에 의존함을 알 수 있다. 즉 성토고가 말뚝캡보사이 간격에 비하여 충분히 높으면 지반아칭파괴가 발생되며 그 반대의 경우는 펀칭전단파괴가 발생된다. 지반아칭파괴는 말뚝캡보 폭과 같은 두께를 가지는 반원통형 아치형태로 성토지반내에 발생한다. 그리고, 말뚝캡보 위에는 쐐기영역이 발생하며 이 쐐기영역은 지반아칭파괴나 펀칭전단파괴가 발달하는 동안에도 변형되지 않은 상태로 남아있다. 펀칭전단파괴시 변형토괴의 경계형상도 실험중 촬영한 사진분석에 근거하여 밝혀질 수 있다.

  • PDF

P-q-t chart 분석기법을 이용한 그라무팅 신뢰성 향상 방안에 관한 실험적 연구 (An experimental study on the improving reliability of grouting by using p-q-t chart analyzing technique)

  • 천병식;최동찬;김진춘
    • 한국터널지하공간학회 논문집
    • /
    • 제10권4호
    • /
    • pp.383-395
    • /
    • 2008
  • 연약지반개량 기술 중의 하나인 그라우팅이 차수 보강 목적으로 다양한 건설공사에서 널리 활용되고 있지만 그라우팅공법이 지반내부에서 시행되는 기술적 특성상 그 시공과정의 적합성 및 시공 후 효과확인 방법에 대한 문제점이 많다. 본 연구 대상의 그라우팅 p-q-t chart는 주입속도(q)와 주입압(p)의 경시변화(t)에 대한 관계를 나타내는 지표로서 그라우팅 시공과정을 모니터링하여 시공인자의 적합성을 평가하여 조정할 수 있는 유일한 수단이다. 본 연구에서는 시험 및 시공과정을 일괄적으로 관리할 수 있는 자동 주입관리 시스템(AGS; automatic grouting system)를 이용하여 정밀한 p-q-t chart를 검출할 수 있었으며, 검출된 p-q-t chart의 유형을 표준유형과 비교분석을 통해서 대상지반의 주입특성에 대한 정보를 추정할 수 있었다. 향후 본 연구에서 적용한 자동 주입관리 시스템을 이용하여 도출된 p-q-t chart를 활용한다면 주입재료, 주입공법, 주입속도 및 주입압 등 시공인자의 적합성을 판정하고 조정하는 객관적 지표로 활용하여 그라우팅 시공의 신뢰성을 획기적으로 향상시킬 수 있을 것으로 기대된다.

  • PDF

원발성 담관성 간경변과 동반된 문맥폐고혈압 1예 (A Case of Portopulmonary Hypertension Associated with Primary Biliary Cirrhosis)

  • 김세중;이은주;정기환;강은해;이승룡;임홍의;임형준;이상엽;김제형;신철;심재정;인광호;강경호;유세화
    • Tuberculosis and Respiratory Diseases
    • /
    • 제62권5호
    • /
    • pp.421-426
    • /
    • 2007
  • 진행성 간질환의 합병증으로 발생하는 문맥폐고혈압은, 이차성 폐동맥고혈압 중에서 진행성 간질환에 의한 문맥고혈압과 연관된 폐동맥고혈압으로 분류되며, 독특한 임상적, 병태생리학적 특징을 보인다. 임상양상은 점진적인 운동성 호흡곤란, 흉통 등을 호소하지만, 증상 없이 우연히 발견되는 경우도 있다. 심초음파 검사를 통해 예비적으로, 우심장 도관삽입으로 직접 우심실 및 평균 폐동맥압을 측정하여 진단할 수 있다. 치료는 칼슘통로차단제, 프로스타노이드 등을 사용하지만, 근본적인 치료를 위해서는 간 및 폐이식을 고려해야 한다. 저자들은 53세 여자로 20년 전에 간경변을 진단받은 후 호흡곤란으로 내원한 환자에게서, 간경변의 원인으로 원발성 담관성 간경변을 진단하고, 호흡곤란의 원인으로 문맥폐고혈압을 진단하여 치료하였기에 문헌고찰과 함께 보고한다.

도심재생하천 내 수리적 특성이 열환경 변화에 미치는 영향 평가: 청계천을 대상으로 (Impact Assessment on the Change of Thermal Environment, According to the Hydraulic Characteristic Urban Regeneration Stream: Cheonggyecheon Case Study)

  • 김정호;이주승;윤용한
    • 환경정책연구
    • /
    • 제14권2호
    • /
    • pp.3-25
    • /
    • 2015
  • 도심재생하천 내부의 수리적 특성이 열환경 변화에 미치는 영향을 알아보고자 하천의 물리적 구조와 수리적 특성, 기상요소, 온열환경을 분석하였다. 연구 대상지는 복원된 도시하천으로서 큰 의의를 가지는 청계천을 선정하였다. 유형은 물리적 구조별 녹피율의 차이에 따라 유형 I(0.0%)과 유형 II(20.2%)로 구분하였다. 여울이 끝나는 Ba지점에서 수온은 $0.2^{\circ}C$ 감소, 유속은 0.7~0.9m/s 증가, 용존산소량은 0.5~0.6mg/L 증가하였으며, 기온은 평균 $1.1{\sim}1.4^{\circ}C$ 감소, 상대습도는 평균 6.6~8.7% 증가, 풍속은 불규칙한 변화를 보였다. 습구흑구온도지수 분석결과, 유형에 따른 상류부의 하천 내부와 수면 외부의 값의 차이는 미비하였으나, 유형 I의 하류부에서 감소폭은 $0.3{\sim}0.6^{\circ}C$, 유형 II는 $0.8^{\circ}C$ 등이었다. 기온저감의 효과는 수직높이로 유형 I의 경우 120cm, 유형 II는 140cm까지 영향이 있었으며, 거리별 기온저감의 효과는 유형 I의 경우 여울이 끝나는 Ba지점 이후로 증가하였고, 유형 II의 경우 지속해서 감소하였다.

  • PDF