• 제목/요약/키워드: Flow artifact

검색결과 26건 처리시간 0.018초

적응 SFLC(Scaled Fourier Linear Combiner)를 이용한 활동 중의 PPG 신호의 잡음 감소 (Noise Reduction of PPG Signal During Free Movements Using Adaptive SFLC(Scaled Fourier Linear Combiner))

  • 김성민;차은종;김덕원;유재하;김동연;김수찬
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권3호
    • /
    • pp.138-141
    • /
    • 2006
  • Blood flow is one of vital signals related to human physiological information. Photoplethysmograph (PPG) has been used to measure indirectly heart rate, blood oxygen saturation ($SpO_2$), and so on. Because PPG signal is weak and sensitive to motion artifacts, it is very important to continuously obtain stable PPG signal during free movement. In this study, we applied the scaled Fourier linear combiner (SFLC) using both the adaptive filter and FLC to remove effectively the motion artifacts as well as background noise in the real time without additional signal correlated with motion from a accelerometer. The proposed method would be useful to reduce the movement and background noise which are not synchronized with heart rate.

혈관조영영상에서 고화질 혈관가시화를 위한 영상정합 (Image Registration for High-Quality Vessel Visualization in Angiography)

  • 홍헬렌;이호;신영길
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2003년도 추계학술대회 및 정기총회
    • /
    • pp.201-206
    • /
    • 2003
  • In clinical practice, CT Angiography is a powerful technique for the visualziation of blood flow in arterial vessels throughout the body. However CT Angiography images of blood vessels anywhere in the body may be fuzzy if the patient moves during the exam. In this paper, we propose a novel technique for removing global motion artifacts in the 3D space. The proposed methods are based on the two key ideas as follows. First, the method involves the extraction of a set of feature points by using a 3D edge detection technique based on image gradient of the mask volume where enhanced vessels cannot be expected to appear, Second, the corresponding set of feature points in the contrast volume are determined by correlation-based registration. The proposed method has been successfully applied to pre- and post-contrast CTA brain dataset. Since the registration for motion correction estimates correlation between feature points extracted from skull area in mask and contrast volume, it offers an accelerated technique to accurately visualize blood vessels of the brain.

  • PDF

1.5 Tesla 기기에서 중심주파수 조정과 송 신호강도(Transmission Gain)값 변화에 따른 인공물이 있는 자기공명영상의 질 보상에 관한 연구 (A Study on Compensation for Imaging Qualities Having Artifact with the Change of the Center Frequency Adjustment and Transmission Gain Values at 1.5 Tesla MRI)

  • 이재승;구은회;박철수;이선엽;이한주
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.244-252
    • /
    • 2009
  • 자화율(susceptibility) 및 강자성체(ferromagnetic body)에 의한 인공물(artifact) 영향을 줄이기 위하여 중심주파수(center frequency) 정렬과 송 신호강도(transmission gain)값의 변화로 영상의 질을 보상하고자 한다. 본원에 내원한 환자 중 총 30명에 대하여 두 경부(head and neck)질환을 의심한 환자 중 남자 15명, 여자 15명으로 평균나이는 45세이었다. 사용된 장비는 GE 1.5T unit (GE, General Electric medical system, High Density)를 사용하여 Transmission gain (TG) 값을 평균 몸무게 60 kg을 기준으로 70, 90, 110, 130, 150까지 변환하여 검사를 하였다(p<0.05). 본 연구의 결과로서, 조영제 주입 전과 후의 지방소거 결과는 TG (70, 90, 110, 130, $150=3.23{\pm}0.35$, $4.31{\pm}0.02$, $4.23{\pm}0.21$, $5.12{\pm}0.25$, $7.13{\pm}0.72$, $8.31{\pm}0.01$, $5.21{\pm}0.15$, $6.14{\pm}0.08$, $5.23{\pm}0.72$, $5.91{\pm}0.06$)값에 다른 점수 분포를 나타났다(p<0.05). 절대값 대조도대 잡음비는 (TG, CNRpre, CNRpost, 70: $-1.44{\pm}0.11$, $-2.7{\pm}0.04$, 90: $-2.18{\pm}0.42$, $-4.41{\pm}0.43$, 110: $-2.89{\pm}0.43$, $-5.23{\pm}0.02$, 130: $-2.34{\pm}0.05$, $-5.26{\pm}0.01$, 150: $-2.09{\pm}0.08$, $-3.87{\pm}0.12$)을 얻었다(p<0.05). 본 실험에서 중심주파수 조정과 송 신호강도(transmission gain)값의 변화에 따라 인공물이 있을 때 영상의 질을 보상할 수 있다는 것을 확인하였다.

  • PDF

Rheogram으로 본 실혈시 신장혈액유통 변화 (Rheographic View of the Change in the Renal Blood Flow in Acute Hemorrhage)

  • 장세구;신동훈
    • The Korean Journal of Physiology
    • /
    • 제5권1호
    • /
    • pp.59-69
    • /
    • 1971
  • Studies were undertaken on the changes in the renal blood flow by relating them with the alterations in the amplitudes in the rheogram of rabbits. The changing pattern of the electrical conductivity was recorded by means of the needle electrodes inserted into the kidney and the surrounding aluminium foil which was grounded. The Impedance Rheograph manufactured by the Narco Company was used. The small artifact which persisted after ligation of the renal vessels was subtracted from the value obtained in each pulsatile wave in the rheogram. The animals were nembutalized intravenously, 30 mg/kg. A plastic canule was inserted into the carotid artery and the arterial blood pressure was monitored continuously with the pressure transducer connected to the physiograph. Stepwise bleedings were performed on the animal. The first bleeding was between 13 to 18 ml in the amount, and it was folowed by consecutive hemorrhages, 5 or 10 ml each time. The total amount of bleeding was summed as much as 1.5-2% of the body weight. Two minutes fter each bleeding th arterial blood pressure, ECG and the rheogram were taken. That was the necessary time to obtain the stabilized picture of each parameter. After closing the bleeding process, the shed blood was retransfused into the animal and the response in the renal blood flow was observed as well as the arterial blood pressure. Particularly the presence or absence of the autoregulatory mechanism in the situation of the hemorrhage was also studied. The results obtained were as follows: 1. In 7 cases out of 22, that was about one third of the total number of experiments, the autoregulatory mechanism of the renal blood flow persisted even in acute hemorrhage, and the decreases in the renal blood flow were less than 10% of the control values even when the arterial blood pressure dropped to 66-87% of the original value obtained before the bleeding. 2. Because of the stepwise bleeding the exact blood pressure at which the renal blood flow reduced as much as one third of the control value could not be obtained. However, the results revealed that the approximate pressure, expressed as percentage of the control value, was 50-60% in 3 cases, 61-70% in 4 cases and 71-80% in 8 cases. In one case the decrease in the renal blood flow exceeded one third of the control value before the pressure dropped to 80% of the control. 3. In 19 cases the decreases in the renal blood flow exceeded one half of the control values by hemorrhage. Then the arterial blood pressure revealed less than 40% of the control value in 6-cases. In 2 cases the pressure was 51-60% of the control pressure. In 5 cases the range of bleed pressure was 61-70%, and in e remaining 6 cases the pressure ranged from 71 to 80% of e control value. 4. Out of 15 cases of retransfusion after definite decreases in the renal blood flow loller·ing the hemorrhage, 9 cases restored their renal blood flow. On the contrary 6 cases showed low values even when the shed blood was retransfused. 5. Theories concerning the mechanism of the autoregulation of the renal blood flow were reviewed for the purpose of explanation of the results obtained. However, there are much to be done before greater satisfaction

  • PDF

에어로졸 중화기의 성능이 고하전 입자의 크기분포 측정에 미치는 영향 (Effect of Performance of Aerosol Charge Neutralizers on the Measurement of Highly Charged Particles Using a SMPS)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1498-1507
    • /
    • 2003
  • A SMPS(scanning mobility particle sizer) system measures the number size distribution of particles using electrical mobility detection technique. An aerosol charge neutralizer, which is a component of the SMPS, is a bipolar charger using a radioactive source to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. In this study, the effect of the particle charging characteristics of two aerosol charge neutralizers on the measurement using a SMPS system was experimentally investigated for highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0.5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.3 to 3.0 L/min. The results show that the non-equilibrium character in particle charge distribution appears as the air flow rate increases although the particle number concentration is relatively low in the range of 1.5∼2x10$^{6}$ particles/㎤. The low neutralizing efficiency of the $^{85}$ Kr aerosol charge neutralizer for highly charged particles can cause to bring an artifact in the measurement using a SMPS system. However, the performance of the $^{210}$ Po aerosol charge neutralizer is insensitive to the air flow rate.

컴퓨팅 사고 실천 분석도구 개발 및 이의 활용에 대한 기초연구 (The preliminary study of developing computational thinking practice analysis tool and its implementation)

  • 박영신;황진경
    • 대한지구과학교육학회지
    • /
    • 제10권2호
    • /
    • pp.140-160
    • /
    • 2017
  • 본 연구의 목적은 컴퓨팅 사고(Computational Thinking, 이하 CT)의 실천을 분석하는데 사용할 컴퓨팅 사고 실천 분석 도구(Computational Thinking_STEAM_Analyzing Tool, 이하 CT_STEAM_AT)를 개발하는 것이다. 먼저, STEAM 프로그램에 반영되어 나타나는 CT의 실천이 무엇인지에 대해 조작적 정의를 내리고, 이를 바탕으로 CT가 STEAM 수업에서는 어떠한 특징으로 나타나는지를 파악하여 CT실천을 관찰할 수 있는 CT_STEAM_AT를 개발하는 것이다. 또한, 이를 바탕으로 모범적인 STEAM 수업을 분석하였을 때 얼마나 다양한 CT실천이 포함되어 있는지를 탐색하는 것이 연구의 목적이라 할 수 있겠다. 먼저, CT_STEAM_AT 개발연구에서는 '과학교육에서의 CT란 무엇인가?'라는 질문을 시작으로 CT의 실천 구성요소에 대해 정의하기 위해 3가지의 중요한 자료를 주요 연구자료로 이용하고 분석하여 CT_STEAM_AT를 개발하였다. 첫 번째 개발연구에서는 CT_STEAM_AT의 CT의 실천 구성요소를 크게 5가지로 구분하였다. (1) 현실문제와 컴퓨팅 연결하기, (2) 컴퓨팅 산출물(artifact)을 개발하기 위한 도구나 컴퓨터 사용하기, (3) 추상화 과정, (4) 컴퓨팅 실천과정 및 산출물을 분석하고 평가하기, 그리고 (5) 의사소통하고 협력하기이다. 또한, 연구를 진행하던 중 CT의 구성요소들 사이의 상호작용으로 인하여 일정한 흐름이 존재한다고 해석하여 CT실천 흐름도를 개발하였다. 두 번째 CT 적용연구에서는 CT_STEAM_AT를 모범적인 STEAM 프로그램에 적용하였다. 먼저, 모범적인 STEAM 프로그램을 선정하기 위해서 4가지의 선정조건을 고려하여 선정하였다. 이런 과정을 통해 선정된 STEAM 프로그램에 CT_STEAM_AT를 적용시켜 CT가 반영된 정도를 파악하고, 더 나아가 부족하거나 제한적으로 나타난 CT의 실천 부분을 보완할 수 있는 방안을 제안해보았다. 본 연구의 결과, 개발된 CT_STEAM_AT를 통해 STEAM 프로그램에 반영된 CT 종류 및 수준을 파악하는데 효율적임을 알 수 있었고, 기술과 공학 부분을 보충하고, 실제적으로 나타나는 CT의 실천을 정의함으로 인해 STEAM 교육의 활성화를 기대할 수 있을 것이다.

프로젝션 타입 고속 스핀 에코 영상 (Projection-type Fast Spin Echo Imaging)

  • 김휴정;김치영;김상묵;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권1호
    • /
    • pp.42-51
    • /
    • 2000
  • 목적: Projection-type Fast Spin Echo (PFSE) 영상 기법은 일반적인 Fast Spin Echo (FSE) 기법과 비교하여 환자의 움직임과 혈류에 강한 장점이 있는 반면. $T_2$ 대조도(contrast)를 조절하기가 어려운 단점이 있다. 본 연구에서는 PFSE의 대조도를 이론적으로 분석하였고 컴퓨터 모의실험을 통하여 다양한 effective echo time (TE) 을 갖는 일반적인 FSE와 비교, 분석하였다. 또한 인체 실험을 통하여 제안한 PFSE 영상기법으로 움직 임과 혈류에 강인한 $T_2$ 강조 영상을 얻을 수 있음을 보였다. 대상 및 방법: 본 연구에서는 1.OT 전신 MRI 시스템에서 새로운 k-space의 배치를 갖는 PFSE 펠스 시권스를 구현하여, PFSE와 FSE 방식의 $T_2$ 대조도를 컴퓨터 모의설험과 인체 실험을 통하여 비교, 분석하였다. 컴퓨터 모의실험에서는 서로 다른 $T_2$ 값을 갖는 팬텀을 구현하여 다양한 effective TE에 대한 FSE 영상과 PFSE 영상을 재구성하여 대조도를 비교하였다. 인체 설험에서는 multi-slice $T_2$ 강조 두부 영상을 PFSE와 FSE로 얻어 영상기법간의 $T_2$ 대조도를 비교하였다. 결과: 이론적인 분석에서 PFSE의 $T_2$ 대조도는 effective TE가 80-l00ms 정도의 FSE 영상과 등가하게 나타나 $T_2$ 강조 영상을 얻을 수 있을 것으로 판단되었다. 컴퓨터 모의실험에서 PFSE 재구성 영상은 effective TE가 96ms인 FSE 영상과 대조도가 비슷하게 나타났다. 인체 실험에 서도 PFSE 영상은 effective TE가 96ms인 FSE 영상과 비슷하게 나타났으며. PFSE 방법이 FSE 방법에 비하여 움직 엄과 혈류와 관련한 artifact에 강인함을 확인 할 수 었었다. 결론: PFSE 기법은 k-space의 극좌표계에서 서로 다른 각도를 갖는 여러 line틀을 다중 스핀 에코 기법으로 측정하는 방식이다. PFSE기법은 FSE와 비교하여 환자의 움직임과 혈류에 강한 장점이 있는 반면, $T_2$ 대조도를 조절하기가 어려운 단점이 있다. 본 연구에서는 PFSE 방식으로 FSE와 대등한 $T_2$ 대조도 ($T_2$ 강조 영상)를 얻을 수 있음을 이론과 컴퓨터 모의실험 밝히고, 인체 실험을 통하여 확인하였다.

  • PDF

대기오염의 확산 연구를 위한 산성 오염물질의 연속 측정법의 개발 (Development of Continuous Monitoring System of Acidic Pollutants for The Studies of Their Diffusion in The Atmosphere)

  • 정형근;피.케이. 다스쿱타;이대운
    • 분석과학
    • /
    • 제5권3호
    • /
    • pp.269-276
    • /
    • 1992
  • An ion-exchange/conductometric method is applied for the determination of total acidity in simulated atmospheric samples. Non-$H^+$ cations and strong acid anions are enriched by the preconcentrator columns in series and eluted through the corresponding parallel suppressor units. The conductivities from each channel correspond to the concentrations of the resulting ionized species in equivalents per unit volume. The difference is the measure of acidity due to strong acids. With 5-min sampling at a flow rate of 0.3 mL/min, the detection limits for ${NH_4}^+$ and ${SO_4}^{2-}$ are 0.3 and $0.1{\mu}equiv/L$, respectively. The acidity for samples composed of various ions can be determined without significant error, usually less than 5%. The proposed method discriminates against the artifact from the $CO_2$ dissolution. Principles of acidity measurements are also presented.

  • PDF

Hypointensity on Susceptibility-Weighted Images Prior to Signal Change on Diffusion-Weighted Images in a Hyperacute Ischemic Infarction: a Case Study

  • Kim, Dajung;Lee, Hyeonbin;Jung, Jin-Man;Lee, Young Hen;Seo, Hyung Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권2호
    • /
    • pp.131-134
    • /
    • 2018
  • Susceptibility-weighted imaging (SWI) is well known for detecting the presence of hemorrhagic transformation, microbleeds and the susceptibility of vessel signs in acute ischemic stroke. But in some cases, it can provide the tissue perfusion state as well. We describe a case of a patient with hyperacute ischemic infarction that had a slightly hypodense, patchy lesion at the left thalamus on the initial SWI, with a left proximal posterior cerebral artery occlusion on a magnetic resonance (MR) angiography and delayed time-to-peak on an MR perfusion performed two hours after symptom onset. No obvious abnormal signals at any intensity were found on the initial diffusion-weighted imaging (DWI). On a follow-up MR image (MRI), an acute ischemic infarction was seen on DWI, which is the same location as the lesion on SWI. The hypointensity on the initial SWI reflects the susceptibility artifact caused by an increased deoxyhemoglobin in the affected tissue and vessels, which reflects the hypoperfusion state due to decreasing arterial flow. It precedes the signal change on DWI that reflects a cytotoxic edema. This case highlights that, in some hyperacute stages of ischemic stroke, hypointensity on an SWI may be a finding before the hyperintensity is seen on a DWI.

심장 자기공명영상 (Cardiac MRI)

  • 이종민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권1호
    • /
    • pp.1-9
    • /
    • 2007
  • 심장의 영상화에 장애가 되는 요인은 심장 운동, 호흡, 심장 내 혈류 등에 의한 인공물(artifact) 과 심장 조직의 용적이 작음으로 인한 낮은 신호 대 잡음비 등이 있다. 심장 운동에 의한 화질 저하를 막기 위해 신속영상기법(fast imaging technique) 을 이용하여 심장 운동의 특정 위상(phase) 에서만 영상을 얻는 심장동기(cardiac gating) 방법을 이용하고 있다. MRI를 이용한 심장의 검사는 심장의 형태, 심실 기능, 심근 관류, 심근 대사, 관상동맥 영상 등을 대상으로 한다. 심장의 형태적 진단에 있어서 심근내 수분의 정도와 지방조직을 보기 위해 이중(double) 혹은 삼중역전회복기법(triple inversion recovery technique) 을 사용한다. 심근관류검사를 위해서는 조영증강신속경사에코법(contrast-enhanced fast gradient echo technique)을 사용하여 일차통과조영증강(first-pass enhancement) 을 검사한다. 또한 10-15분 지연영상을 얻어 심근내 조영제의 재분포를 검사하여 만성심근경색 등의 심근파괴부위를 확인한다. 심실기능 평가를 위해서는 신속경사에 코법을 이용한 영화영상(cine image) 이 사용되며 심실의 국소적 운동이상 및 심실기능의 정량적 검사가 가능하다. MRI는 관상동맥영상을 제외한 포괄적 심장검사에 실용성이 있다. 특히 지연영상은 다른 검사장비에선 얻을수 없는 유용한 정보이다.

  • PDF