• 제목/요약/키워드: Flow and mass transfer

검색결과 974건 처리시간 0.027초

3차원 미세 구조물 제작을 위한 폴리머 유동 모델의 적용 (Application of the Polymer Behavior Model to 3D Structure Fabrication)

  • 김종영;조동우
    • 한국정밀공학회지
    • /
    • 제26권12호
    • /
    • pp.123-130
    • /
    • 2009
  • This study presents the application of a polymer behavior model that considers fluid mechanics and heat transfer effects in a deposition system. The analysis of the polymer fluid properties is very important in the fabrication of precise microstructures. This fluid behavior model involves the calculation of velocity distribution and mass flow rates that include the effect of heat loss in the needle. The effectiveness of the proposed method was demonstrated by comparing estimated mass fluid rates with experimental values. The mass fluid rates under various process conditions, such as pressure, temperature, and needle size, reflected the actual deposition state relatively well, and the assumption that molten polycaprolactone(PCL) is a non-Newtonian fluid was reasonable. The successful fabrication of three-dimensional microstructures demonstrated that the model is valid for predicting the polymer behavior characteristics in the microstructure fabrication process. The results of this study can be used to investigate the effect of various parameters on fabricated structures before turning to experimental approaches.

1열 원형 충돌수분류군에 의한 열전달의 실험적 연구 (제2보, 노즐-전열면간 거리의 영향) (Impingement heat transfer within 1 row of circular water jets: Part 2-Effects of nozzle to heated surface distance)

  • 엄기찬;이종수;김상필
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.59-66
    • /
    • 2000
  • In a previous paper, we have examined the effects of nozzle configuration and jet to jet spacing on the heat transfer of 1 row of circular water jets. In this paper, experiments have been conducted to obtain the effects of nozzle to target plate distances on the heat transfer of 1 row of 3 jets and 1 row of 5 jets. The nozzle configurations are Cone type, Reverse cone type and Vertical circular type. Nozzle to target plate distance H was varied from 16 mm(H/D=2) to 80mm(H/D=10). For fixed value of mass flow rate and nozzle to target plate distance, larger values of average Nusselt number were obtained for the smaller jet to jet spacing. For the array of water jets, the average heat transfer was decreased slightly with increasing nozzle to target plate distance at low jet velocity of $\textrm{V}_{o}$=3 m/s. However, except for $\textrm{V}_{o}$=8 m/s of 1 row of 5 jets, it was increased with increasing nozzle to target plate distance at high jet velocity of $\textrm{V}_{o}$$\geq$6m/s. We proposed to apply the nozzle configuration of maximum average heat transfer to each nozzle to target plate distance for 1 row of 3 jets, and, it was Reverse cone type nozzle for 1 row of 5 jets(Reynolds number$\geq$36000).

  • PDF

물 난류에서의 암모니아 흡수 거동 해석 (Interpretation of Ammonia Absorption Behavior in Water Turbulent Flow)

  • 이상룡;박진원
    • 유기물자원화
    • /
    • 제27권3호
    • /
    • pp.75-80
    • /
    • 2019
  • 본 연구는 난류로 흐르는 물에서 미세먼지 전구체 중 하나인 암모니아가 흡수되는 거동을 해석하였다. 물의 흐름이 층류보다 난류인 조건에서 암모니아의 침투 깊이가 더 깊으므로 레이놀즈 수가 $10^4$보다 큰 난류 조건이 고려된다. 거동 해석을 위하여, 무차원 물질전달 지배방정식과 상온 기준의 일정한 물성치들이 사용되었다. 물에서의 암모니아 확산계수와 물의 동점도계수는 각각 $2.45{\times}10^{-9}m^2/s$$1{\times}10^{-6}m^2/s$이었다. 물에서의 암모니아 농도 분포는 암모니아에 노출되기 시작하는 지점으로부터의 위치에 대하여 산출되었다. 혼합 깊이에 따른 정량적인 분포 또한 도출되었다. 이와 같은 정량적인 해석은 난류로 흐르는 물이 층류로 흐르는 것과 비교하여 얼마나 더욱 효율적으로 암모니아를 제거할 수 있는지에 대한 통찰력을 제시할 수 있다.

압력용기로부터 압력방출장치를 통한 가스 방출에 관한 포괄적 고찰 (Comprehensive Consideration on the Discharge of Gases from Pressurized Vessels through Pressure Relief Devices)

  • 정창복
    • 한국안전학회지
    • /
    • 제35권6호
    • /
    • pp.32-45
    • /
    • 2020
  • The problem of determining the discharge rates of gases from pressurized vessels through pressure relief devices was dealt with comprehensively. First, starting from basic fluid flow equations, detailed modeling procedures were presented for isentropic nozzle flows and frictional flows in a pipe, respectively. Meanwhile, physical explanations were given to choking phenomena in terms of the acoustic velocity, elucidating the widespread use of Mach numbers in gas flow models. Frictional flows in a pipe were classified into adiabatic, isothermal, and general flows according to the heat transfer situation around the pipe, but the adiabatic flow model was recommended suitable for gas discharge through pressure relief devices. Next, for the isentropic nozzle flow followed by adiabatic frictional flow in the pipe, two equations were established for two unknowns that consist of the Mach numbers at the inlet and outlet of the pipe, respectively. The relationship among the ratio of downstream reservoir pressure to upstream pressure, mass flux, and total frictional loss coefficient was shown in various forms of MATLAB 2-D plot, 3-D surface plot and contour plot. Then, the profiles of gas properties and velocity in the pipe section were traced. A method to quantify the relationship among the pressure head, velocity head, and total friction loss was presented, and was used in inferring that the rapid increase in gas velocity in the region approaching the choked flow at the pipe outlet is attributed to the conversion of internal energy to kinetic energy. Finally, the Levenspiel chart reproduced in this work was compared with the Lapple chart used in API 521 Standatd.

Evaluation Methods and Design for Bioartificial Liver Based on Perfusion Model

  • Park Yueng Guen;Ryu Hwa-Won
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제10권1호
    • /
    • pp.9-15
    • /
    • 2005
  • A bioartificial liver (BAL) is a medical device entrapping living hepatocytes or immortalized cells derived from hepatocytes. Many efforts have already been made to maintain the functions of the hepatocytes in a BAL device over a long term. However, there is still some uncertainty as to their efficacy. and their limitations are unclear. Therefore, it is important to quantitatively evaluate the metabolic functions of a BAL. In previous studies on in vitro BAL devices, two test methods, an initial bolus loading and constant-rate infusion plus initial bolus loading, were theoretically carried out to obtain physiologic data on drugs. However, in the current study, the same two methods were used as a perfusion model and derived the same clearance characterized by an interrelationship between the perfusate flow rate and intrinsic clearance. The interrelationship indicated that the CL increased with an increasing perfusate flow rate and approached its maximum value, i.e. intrinsic clearance. In addition, to set up an in vivo BAL system, the toxic plateau levels in the BAL system were calculated for both series and parallel circuit models. The series model had a lower plateau level than the parellel model. The difference in the toxic plateau levels between the parallel and series models increased with an increasing number of BAL cartridges.

온도 변화에 따른 수돗물 저장 저수조 내 잔류염소에 관한 수학적 모형 시뮬레이션 (Mathematical Model Simulations Assessing the Effects of Temperature on Residual Chlorine Concentrations in Water Storage Tanks)

  • 노유래;박준홍
    • 한국물환경학회지
    • /
    • 제33권2호
    • /
    • pp.187-196
    • /
    • 2017
  • To ensure hygienic safety of drinking water in a water storage tank, the concentrations of residual chlorine should be above a certain regulation level. In this study, we conducted model simulations to investigate the effects of temperature on residual chlorine in water storage tank conditions typically used in Seoul. For this, values of model parameters (decomposition rate constant, sorption coefficient, and evaporation mass transfer coefficient) were experimentally determined from laboratory experiments. The model simulations under continuous flow conditions showed that the residual chlorine concentrations were satisfied the water quality standard level (0.1 mg/L) at all the temperature conditions ($5^{\circ}C$, $10^{\circ}C$, $15^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$). Meanwhile, when the tanks had a no flow condition (i.e., no tap-water influent due to a sudden shut-down), the concentrations became lower than the regulatory level after certain periods. The findings from this modeling works simulating Seoul's water storage tanks suggested disappearance rate of residual chlorine could be reduced through the tanks design optimization with maintenance of low water temperature, minimization of air flow and volume, suppression of dispersion and the use of wall materials with low sorption ability.

HCCI 엔진의 실린더 내 유동에 대한 피스톤 보울 형상의 영향 (Influence of piston bowl geometry on the in-cylinder flow of HCCI Engine)

  • 남승만;이계복
    • 에너지공학
    • /
    • 제22권4호
    • /
    • pp.399-405
    • /
    • 2013
  • 엔진 실린더 내부의 난류유동 특성은 내연기관의 열효율을 결정하는 매우 중요한 역할을 한다. 실린더 내 난류유동은 복잡한 3차원 유동으로 유동특성에 대한 자세한 정보는 엔진설계의 최적화를 위해 필수적이다. 균일 예혼합 압축착화(HCCI) 엔진은 가솔린과 디젤엔진 사이의 하이브리드 연소개념이다. 실린더 내 기체의 난류유동은 운동량과 열의 혼합 및 전달률을 증가시키므로 벽면에서의 열전달에 관여하여 HCCI 연소 과정에 중요한 영향을 미치게 된다. 본 연구에서는 연소실 형상에 따른 연소실 내의 기체 난류유동을 LES 모델을 사용한 전산수치해석을 통해 분석하여 HCCI 엔진 연소과정에 미치는 영향을 확인하였고 연구결과는 HCCI 엔진에서 연소실 형상에 따른 연소 특성과 엔진 성능을 개선하기 위한 기본적인 지침에 활용될 수 있다.

마이크로채널 형상에 따른 PCHE 열유동 수치해석 (Numerical Simulation of Thermal Performance of Printed Circuit Heat Exchangers with Microchannels of Different Shapes)

  • 조연화;이규정;문동주;김윤호
    • 대한기계학회논문집B
    • /
    • 제35권1호
    • /
    • pp.61-66
    • /
    • 2011
  • 새롭게 제안된 형상의 마이크로채널 PCHE는 기존의 상용 열교환기에 비해 고성능, 고효율의 특성을 보이며 열교환을 수행한다. 본 연구에서는 I, Wavy, Beehive, Surf, I-Wavy, I-Beehive, I-Surf 의 형상을 갖는 다양한 마이크로채널을 모델링하였다. 질량유속 변화에 따른 다양한 마이크로채널 내 유체의 유동특성, 열전달, 압력강하를 살펴보았고 그 결과는 마이크로채널의 열전달 능력을 향상시키는데 이용된다. I 채널은 새롭게 적용된 채널 형상과의 성능비교를 위해 해석을 수행하였다. 다양한 레이놀즈수 변화 하에서 고온측과 저온측 유체는 대향류 형태로 열교환이 이루어지도록 하였다. 수치해석 결과 Surf 형상이 다른 형상들보다 열교환 성능이 우수함을 확인하였다.

Analysis of the Wet-end Dynamics in Paper Mills

  • 류재용;여영구;서동준;강홍
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2003년도 추계학술발표논문집
    • /
    • pp.306-330
    • /
    • 2003
  • The wet-end dynamics of a paper mill was analyzed to characterize its dynamic behavior during the grade change. The model representing the wet-end section is developed based on the mass balance relationships written for the simplified wet-end white water network. From the linearization of the dynamic model, higher-order Laplace transfer functions were obtained followed by the reduction procedure to give simple lower-order models in the form of $1^{st}$-order or $2^{nd}$-order plus dead times. The dynamic response of the wet-end is influenced both by the white water volume and by the level of wire retention. Effects of key manipulated variables such as the thick stock flow rate, the ash flow rate and the retention aid flow rate on the major controlled variables were analyzed by numerical simulations. The simple dynamic model developed in the present study can be effectively used in the operation and control.

  • PDF

알루미늄 다채널 평판관내 R22의 흐름응축 열전달 성능 비교 (A Comparison of Flow Condensation HTCs of R22 Alternatives in the Multi-Channel Tube)

  • 서영호;임대택;박기정;정동수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1270-1275
    • /
    • 2004
  • Flow condensation heat transfer coefficients(HTCs) of R22 and R134a were measured on horizontal aluminum multi-channel tube. The experimental apparatus was composed of three main parts ; a refrigerant loop, a water loop and a water-ethylene glycol loop. The test section in the refrigerant loop was made of aluminum multi-channel tube of 1.4 mm hydraulic diameter and 0.53 m length. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. The data scan vapor qualities $(0.1{\sim}0.9)$, mass flux ($200{\sim}400$ $kg/m^{2}s$) and heat flux ($7.3{\sim}7.7$ $kW/m^{2}$) at $40{\times}0.2^{\circ}C$ saturation temperature in small hydraulic diameter tube. It was found that some well-known previous correlations were not suitable for multichannel tube. So, It must develop new correlations for multi-channel tubes.

  • PDF