• Title/Summary/Keyword: Flow Test

Search Result 6,497, Processing Time 0.042 seconds

The Inflow of the Creative-Class and Forming of Cultural Landscape on the Kyunglidan-Gil (경리단길 창조계급의 유입과정과 문화경관 형성요인)

  • Yang, Hee eun;Son, Yong-Hoon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.158-170
    • /
    • 2013
  • With the recent 'Creative economy' and 'Cultural prosperity' coming to the fore as a new code to build up a city or a region, it is necessary to focus on strengthening the regional creative capacity as well as developing spontaneous regional culture. In such trend this research aims to explore the Kyunglidan-gil, Seoul, Korea in which creative-class are appearing autogenously in clusters and forming new cultural landscape, to identify the factors of their accumulation and changing aspect of cultural landscape. This study has the following purposes: First, Investigating the historical context of the Kyunglidan-gil's landscape. Second, considering the process of the creative-class being flowed into the Kyunglidan-gil as the subject leading to the modification of the region. Third, their activity was analyzed to consider the unique aspect of forming the cultural landscape at the Kyunglidan-gil. Regarding why the creative-class should flow in, results of the study drew five factors including region in issue compared to inexpensive rents, coexistence with nature, quiet atmosphere seeming isolated from the urban confusion, location possible to test and share individual materials one likes, and a site with synergy effect of activity through the network with acquaintances. Also, five characteristics of cultural landscape forming by the people's activity were drawn - space of communication for increasing creativity, temporary and flexible spatial use, expression of one's identity and taste, distinguishing, and positive use of the existing facilities. Like this, by exposing the 'creative-class', a subject of the leader in changing process of the Kyunglidan-gil, this research identified the aspect of forming cultural landscape.

Gaussian Filtering Effects on Brain Tissue-masked Susceptibility Weighted Images to Optimize Voxel-based Analysis (화소 분석의 최적화를 위해 자화감수성 영상에 나타난 뇌조직의 가우시안 필터 효과 연구)

  • Hwang, Eo-Jin;Kim, Min-Ji;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.275-285
    • /
    • 2013
  • Purpose : The objective of this study was to investigate effects of different smoothing kernel sizes on brain tissue-masked susceptibility-weighted images (SWI) obtained from normal elderly subjects using voxel-based analyses. Materials and Methods: Twenty healthy human volunteers (mean $age{\pm}SD$ = $67.8{\pm}6.09$ years, 14 females and 6 males) were studied after informed consent. A fully first-order flow-compensated three-dimensional (3D) gradient-echo sequence ran to obtain axial magnitude and phase images to generate SWI data. In addition, sagittal 3D T1-weighted images were acquired with the magnetization-prepared rapid acquisition of gradient-echo sequence for brain tissue segmentation and imaging registration. Both paramagnetically (PSWI) and diamagnetically (NSWI) phase-masked SWI data were obtained with masking out non-brain tissues. Finally, both tissue-masked PSWI and NSWI data were smoothed using different smoothing kernel sizes that were isotropic 0, 2, 4, and 8 mm Gaussian kernels. The voxel-based comparisons were performed using a paired t-test between PSWI and NSWI for each smoothing kernel size. Results: The significance of comparisons increased with increasing smoothing kernel sizes. Signals from NSWI were greater than those from PSWI. The smoothing kernel size of four was optimal to use voxel-based comparisons. The bilaterally different areas were found on multiple brain regions. Conclusion: The paramagnetic (positive) phase mask led to reduce signals from high susceptibility areas. To minimize partial volume effects and contributions of large vessels, the voxel-based analysis on SWI with masked non-brain components should be utilized.

The Effect of Pentoxifylline on Radiation-Induced Cardiac Injury in ICR Mice (방사선조사후 발생한 심장손상에서 Pentoxifylline 이 미치는 효과)

  • Suh Hyun Suk;Yang Kwang Mo;Kang Seung Hee;Kang Yun Kyung
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.281-290
    • /
    • 1996
  • Purpose : Chest irradiation leads to a significant cardiac injury in a number of patients. To prevent, or to reduce the risk of radiation-induced cardiac injury, pentoxifylline(PTX), a haemorrheologic agent that improves the blood flow through small blood capillaries has been employed. Materials and Methods : One hundred and eighty ICR mice were divided into three study groups: control, radiation alone, and radiation-pentoxifylline. Each group was subdivided into 12 subgroups: 1 3, 6 and 10 days and 2, 3, 4, 6, 8, 12, 16 and 20 weeks by observation Period after irradiation. The total 15Gy of radiation was delivered in a single fraction through anterior mediastinal port. Pentoxifylline was injected subcutaneously daily 50mg/kg to the back of the mice from the first day of irradiation throughout the observation period. The mice of each group after a certain observation period were sacrificed and sectioned for histopathologic examination of the heart. Result : The findings of acute radiation-induced carditis i.e., heterophilic infiltration and vacuolization and ballooning of endothelial cells were observed upto 6 weeks and reduced sharply afterwards. The late radiation effects including pericarditis with mononuclear cell infiltration, pericardial fibrosis, endothelial cell changes, myocardial degeneration and fibrosis present from 4 weeks onwards after irradiation but with various degree of severity. The overall process of pathologic changes of radiation-pentoxifylline group was similar to those of radiation alone group but the duration of acute stage was relatively short and the severity of late cardiac toxicity was much lesser compared with those of radiation alone group. Conclusion : Pentoxifylline can effectively reduce the late radiation-induced cardiac injury and reslve the acute effects relatively rapidly.

  • PDF

Animal Experiments on an Antithrombogenic Small-Caliber Vascular Prostheses and Vascualr Patch : Observation in Canine Models (항혈전성 소구경 인조 혈관 및 봉합편에 대한 동물 실험)

  • 김수철;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2003
  • Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

Experimental Study on the Hysteresis of Suction Stress in Unsaturated Sand (불포화 모래의 흡입응력 이력현상에 대한 실험적 연구)

  • Song, Young-Suk;Choi, Jin-Su;Kim, Gyo-Won
    • The Journal of Engineering Geology
    • /
    • v.22 no.2
    • /
    • pp.145-155
    • /
    • 2012
  • The matric suction and volumetric water content of Jumunin standard sand with a relative density of 60% were measured using an Automated Soil-Water Characteristic Curve (SWCC) apparatus during both drying and wetting processes. The test time for the drying process was longer than that for the wetting process, because the flow of water is likely to be protected by air trapped in voids within the soils during the drying process. Based on the matric suction and volumetric water content, the SWCC was estimated using the model proposed by van Genuchten (1980). For the drying process, the unsaturated fitting parameters ${\alpha}$, n, and m were 0.399, 8.586, and 0.884, respectively; for the wetting process, the values were 0.548, 5.625, and 8.220, respectively. The hysteresis phenomenon occurred in the SWCCs, which means the SWCC of the drying process is not matched with the SWCC of the wetting process. Using these unsaturated parameters, we estimated the Suction Stress Characteristic Curve (SSCC), based on the relationship between suction stress and the effective degree of saturation. The suction stress showed a rapid decrease when the matric suction exceeds the Air Entry Value (AEV). Therefore, the effective stress of unsaturated soils is different from that of saturated soils when the matric suction exceeds the AEV. The suction stress of the drying process exceeds that of the wetting process for a given effective degree of saturation. The hysteresis phenomenon was also recognized in SSCCs. The hysteresis phenomenon of SSCCs arises from that of SWCCs, which is induced by the ink bottle effect and the contact angle effect. In the case of a sandy slope, the suction stress is positive and acts to enhance the slope stability as the water infiltrates the ground, but is negative when the suction stress exceeds the AEV. The results obtained for the wetting process should be applied in analyses of slope stability, because the process of water infiltration into ground is similar to the wetting process.

The Design of Wireless Underwater Telephone -Analysis of Underwater Background Noise for Wireless Underwater Telephone Design - (수중 무선 전화기의 설계 - 수중무선전화기 설계를 위한 수중소음분석을 중심으로-)

  • 박문갑;윤갑동;김석제;윤종락
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.302-307
    • /
    • 2001
  • The underwater background noise measured in Geoje and Tongyoung diving fishing ground from May to December, 2000 and analyzed to get optimum carrier frequency and transmitter power level for underwater wireless telephone design. The results obtained are summarized as follows: 1. At the Geoje and Tongyoung diving fishing ground, the lowest ambient noise band was 25~30kHz with 57dB and 52dB re 1$\mu$Pa, respectively. 2. At the Geoje and Tongyoung diving fishing ground, the lowest noise band during fishing activity was 67dB and 62dB re 1$\mu$Pa, respectively. 3. At the Geoje diving fishing ground, the noise of water jetter which is a digging machine for subbottom shells was 102dB re 1$\mu$Pa. 4. Considering the design parameters of underwater wireless telephone, it is found that the optimum carrier frequency band is around 30kHz and the transmitter source level should be at least 131dB re 1$\mu$Pa for 500m range telephone.

  • PDF

Varietal Differences in Days Required to Leaf Expansion, Leaf Number on Main Culm, and Days to Heading of Rice under Cold Water Flow System (찬물 흘려대기 논의 수온 분포에 따른 벼의 엽 전개 일수 및 주간엽수와 출수일수의 품종간 차이)

  • 윤성호;윤종선;유길림;박창기;정근식
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.36 no.3
    • /
    • pp.214-219
    • /
    • 1991
  • To clarify the relationship between ambient water temperature and heading characteristics of rice (Oryza sativa L.), twelve of varieties rice were grown in a cold tolerance screening field where water temperature was controlled by continuous cold water irrigation system to test the cold tolerance of rice. When cold water was continuously irrigated with 5 cm of water depth, the water had stagnated for about three hours, and the water temperature increased gradually from inlet toward outlet in the experimental plot. The fluctuation of water temperature was well synchronized with that of ambient air temperature, and the water temperature near outlet became higher than the air temperature at the vegetative phase, while became lower at the reproductive phase of rice plant community. The leaf development rates on main culm increased by increased water temperature. The rice varities, Fukuhikari, Sangpungbyeo and YR3486-16-2 were more sensitive than the others in the response of leaf development to water temperature. However, Janack and Milyang 42 were comparatively less sensitive to water temperature in leaf development. Janack and Paro -white rices required longer days to develop one leaf on main culm at reproductive phase than at vegetative phase. Varietal difference in days required to develop one leaf on main culm of rice plant was more distinctive at the reproductive phase when water temperature was relatively lower than at the vegetative phase with relatively higher water temperature condition. No difference was found between the growth phases, vegetative and reproductive, in the response of average leaf developmental rates to water temperature under the similar air temperature condition. The estimated average days required to develop one leaf on main culm decreased by 1.3 day by 1$^{\circ}C$ increase in water temperature. Varietal differences in the total number of leaves on main culm depended upon the water temperature, in which the varieties such as Fukuhikari, Gwangmyeon-gbyeo, China 988, and YR3486-16-2 showed increased one leaf by increased water temperature, while Sobaekbyeo, Paro-white, Sangpungbyeo, Pungsanbyeo, Samgangbyeo, and Milyang 42 were kept at the same leaf number regardless of water temperature. However, the total leaf number on main culm and days to heading of Janack increased by increased water temperature. The other varieties showed the shortened days to heading by the increase in water temperature with noticeable varietal differences regardless of the variation in the total number of leaves on main culm.

  • PDF

The Electrochemical Chlorination for Marine Plankton Community Disinfection (해양 플랑크톤 군집의 전기분해 염소소독 효과)

  • Kang, Jung-Hoon;Shin, Kyoung-Soon;Hyun, Bong-Gil;Jang, Min-Chul;Kim, Eun-Chan;Chang, Man
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.127-137
    • /
    • 2007
  • To confirm whether or not the Electrochemical Disinfection System (EDS) meet with the D-2 regulation established by IMO (International Maritime Organization), the biological treatment efficacy of the EDS was assessed using three groups of natural marine plankton (bacteria, $10-50\;{\mu}m$ and $>50\;{\mu}m$ sized organisms). Influent water was passed through the EDS under the flow velocity ($23.8\;m^3/hr$) and test design was consisted of control (no treatment) and experimental (10 ppm and 30 ppm) condition for total residual chlorine (TRC). And the biological condition of the influent water followed the standards established by the guidelines for the approval of ballast water management systems. The disinfection efficacy of the $10-50\;{\mu}m$ sized organisms (phytoplankton) was assessed by three kinds of measurements using photomicroscope, epifluorescence microscope and fluorometer (fumer Designs 10-AU). After being passed through the EDS, all motile phytoplankton lost their motility under photomicroscope, the colour of chlorophyll fluorescence fumed from red into green under epifluorescence, and the high chlorophyll fluorescence (Expt. 1: 6.95, Expt. 2: 7.11) detected by fluorometer decreased into value not detected. These results indicated phytoplankton community was totally killed after electrochemical disinfection treatment. Survivorship of the larger organisms than $50\;{\mu}m$ was determined based on the appendage's movement under a stereomicroscope. Natural assemblage collected from ambient seawater was killed shortly after being passed through the EDS, whereas some Artemia remained alive. However, no live Artemia was found after 24 hour further exposure to each TRC concentration (10 and 30 ppm) under darkness. After electrochemical treatment, the target bacteria such as aerobes, coliform and Escherichia coli were completely killed on the basis of CFU (colony forming unit) on Petrifilm plate ($3\;M^{TM}$) after 48 hr incubation. Moreover, no regrowth was found in the three groups of plankton during five days under additional exposure to the treated water. These results indicated that the disinfection efficiency of the EDS on the three groups of plankton satisfy D-2 regulation.

  • PDF

Production and CO2 Adsorption Characteristics of Activated Carbon from Bamboo by CO2 Activation Method (CO2 활성화법에 의한 대나무 활성탄 제조와 CO2 흡착 특성)

  • Bak, Young-Cheol;Cho, Kwang-Ju;Choi, Joo-Hong
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.146-152
    • /
    • 2005
  • The activated carbon was produced from Sancheong bamboo by carbon dioxide gas activation methods. The carbonization of raw material was conducted at $900^{\circ}C$, and $CO_2$ activation reactions were conducted under various conditions: activation temperatures of $750-900^{\circ}C$, flow rates of carbon dioxide $5-30cm^3/g-char{\cdot}min$, and activation time of 2-5 h. The yield, adsorption capacity of iodine and methylene blue, specific surface area and pore size distribution of the prepared activated carbons were measured. The adsorption capacity of iodine (680.8-1450.1 mg/g) and methylene blue (23.5-220 mg/g) increased with increasing activation temperature and activation time. The adsorption capacity of iodine and methylene blue increased with the $CO_2$ gas quantity in the range of $5-18.9cm^3/g-char{\cdot}min$. But those decreased over those range due to the pore shrinkage. The specific volume of the mesopore and macropore of bamboo activated carbon were $0.65-0.91cm^3/g$. Because of this large specific volume, it can be used to the biological activated carbon process. Bamboo activated carbon phisically adsorbed the $CO_2$ of maximum 106 mg/g-A.C in the condition of 90% $CO_2$ and adsorption temperature of $20^{\circ}C$. The $CO_2$ adsorption ability of bamboo activated carbon was not changed in the 5 cyclic test of desorption and adsorption.