• Title/Summary/Keyword: Flow Test

Search Result 6,471, Processing Time 0.037 seconds

A Study on the Nozzle Flow in the Sub-scale High-Altitude Test (축소형 고공환경모사 시험에서의 노즐 유동에 관한 연구)

  • Choi, Jiseon;Lee, Seongmin;Lee, Heejune;Ko, Youngsung;Kim, Seonjin;Lee, Jungmin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1011-1015
    • /
    • 2017
  • In this study, numerical and experimental studies on the nozzle flow in a sub-scale cold flow test were conducted to simulate high altitude condition. In the theoretical calculation, the temperature of the nozzle outlet is calculated to be lower than the liquefaction point, and the fluid exists at the phase change point. Also, numerical analysis result is higher than theory calculation but lower than liquefaction temperature. As a result of cold flow test, it was confirmed that the temperature was much higher than theory and analysis. This is because it assumed that it is adiabatic in the theoretical calculation, but the experiment in the actual environment is not the adiabatic but the heat exchange with the outside exists.

  • PDF

Research on Air Flow Rate Test Method for Blower System (송풍 시스템의 공기유량측정 방법에 관한 연구)

  • Lee, Jun-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.55-60
    • /
    • 2022
  • This study conducted the measurements of air flow rate for blower systems with experiment and numerical. A new airflow rate test method is suggested, with which it is possible to accurate measurements and calculate the air flow rate for blower systems. The blower(axial fan) is an industrial fluid machine device that supplies a large amount of air by driving an impeller with an electric motor, and it is widely used throughout the industry such as steel, power plant, chemical, semiconductor, LC D, food, and cement. The airflow from the blower is for exchanging the heat in the cooling unit or heat exchanger. The temperature of coolants and hydraulic oil primarily depends on the amount of airflow rate through the cooling package so its accurate estimation is very important. Moreover, it required a larger investment in time and cost since it could not be executed until the system is actually made. Therefore, this research is intended to examine the phenomenon of air flow pattern when testing air flow rate, suggested new test method, and show the result of the validation test.

Estimation of Gate Discharge Capacity by Physical Model Test and FLOW-3D (수리모형실험과 FLOW-3D를 이용한 배수갑문 통수능력 검토)

  • Park, Byong-Jun;Lee, Sang-Hwa
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.2
    • /
    • pp.168-175
    • /
    • 2008
  • In this study, we estimated the discharge capacity of Solicheon sluice gate in Gunjang national industrial complex by hydraulic physical scale model test and FLOW-3D. It was showed that the discharge capacity of gate carried by physical model test and numerical analysis was similar.

Evaluation of Structural Integrity for HANARO Capsule Structure by Vibration Test and Analysis (진동시험 및 해석을 통한 하나로 캡슐 구조물의 구조건전성 평가)

  • 이영신;강연환;최명환;신도섭
    • Journal of KSNVE
    • /
    • v.10 no.2
    • /
    • pp.261-268
    • /
    • 2000
  • The instrumented capsule is subjected to flow-induced vibration(FIV) due to the flow of the primary coolant and then the structural integrity of the capsule during irradiation in the HANARO reactor is an issue of major concern. For this purpose the acceleration was measured by four accelerometers attached to the protection tube of the capsule mainbody and the displacement of test holes was calcultated using commercial finite element program ANSYS to evaluate the structural interference with the neighboring flow tubes under the reactor operating condition. The calculated displacements of test holes in the reactor in-core were found to be lower than the values of allowable design criteria.

  • PDF

Investigation of Leakage Characteristics of Straight and Stepped Labyrinth Seals

  • Kim, Tong-Seop;Kang, Soo-Young
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.3
    • /
    • pp.253-259
    • /
    • 2010
  • Leakage characteristics of two labyrinth seals with different configurations (straight vs stepped) were investigated. Leakage flows were predicted by computational fluid dynamics (CFD) for the two configurations and compared with test data. A semi-analytical leakage prediction tool was also tried to predict the leakage. It was confirmed that the CFD gives quite good agreements with test data. The analytical tool also yielded similar leakage behaviors with test results, but the overall agreement with test data was not as good as that of the CFD. The effect of flow direction in the stepped seal on leakage flow was examined. The dependence of leakage performance, in terms of flow function, on the seal clearance size was investigated. Flow function decreased with decreasing clearance in the straight seal, while the trend was reversed in the stepped seal.

An Experimental Study of the Effect of the Test-well Arrangement on the Partitioning Interwell Tracer Test for the Estimation of the NAPL Saturation (지하수 유동 방향에 대한 관정배열이 분배추적자 시험에 미치는 영향 분석)

  • Kim, Bo-A;Kim, Yongcheol;Yeo, In Wook;Ko, Kyung-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.111-122
    • /
    • 2014
  • Partitioning interwell tracer test (PITT) is a method to quantify and qualify a site contaminated with NAPLs (Non-Aqueous Phase Liquids). Analytical description of PITT assumes that the injection-pumping well pair is on the line of the ambient groundwater flow direction, but the test-well pair could frequently be off the line in a real field site, which could be an erroneous factor in analyzing PITT data. The purpose of this work is to study the influence of the angle of the test-well pair on the ambient groundwater flow direction based on the result from PITT. From the experiments, it was found that the obliqueness of the test-well pair to the ambient groundwater flow direction could affect the tracer test resulting in a decreased NAPL estimation efficiency. In case of an oblique arrangement of the test-well pair to the ambient flow direction, it was found that the injection of a chase fluid could enhance the estimation efficiency. An increase of the pumping rate could enhance the recovery rate but it cannot be said that a high pumping rate can increase the test efficiency because a high pumping rate cannot give partitioning tracers enough time to partition into NAPLs. The results have a implication that because the arrangement of the test-well pair is a controlling factor in performing and interpreting PITT in the field in addition to the known factors such as heterogeneity and the source zone architecture, flow direction should be seriously considered in arranging test-well pair.

A Study on Current Characteristics Based on Design and Performance Test of Current Generator of KRISO's Deep Ocean Engineering Basin

  • Kim, Jin Ha;Jung, Jae Sang;Hong, Seok Won;Lee, Chun Ju;Lee, Yong Guk;Park, Il Ryong;Song, In Haeng
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.446-456
    • /
    • 2021
  • To build an environment facility of a large-scale ocean basin, various detailed reviews are required, but it is difficult to find data that introduces the related research or construction processes on the environment facility. The current generator facility for offshore structure safety evaluation tests should be implemented by rotating the water of the basin. However, when the water in the large basin rotates, relatively large flow irregularities may occur and the uniformity may not be adequate. In this paper, design and review were conducted to satisfy the performance goals of the DOEB through computational numerical analysis on the shape of the waterway and the flow straightening devices to form the current in the large tank. Based on this, the head loss, which decreases the flow rate when the large tank water rotates through the water channel, was estimated and used as the pump capacity (impeller) design data. The impeller of the DOEB current generator was designed through computational numerical analysis (CFD) based on the lift surface theory from the axial-type impeller shape for satisfying the head loss of the waterway and maximum current velocity. In order to confirm the performance of the designed impeller system, the flow rate and flow velocity performance were checked through factory test operation. And, after installing DOEB, the current flow rate and velocity performance were reviewed compare with the original design target values. Finally, by measuring the current velocity of the test area in DOEB formed through the current generator, the spatial current distribution characteristics in the test area were analyzed. Through the analysis of the current distribution characteristics of the DOEB test area, it was confirmed that the realization of the maximum current velocity and the average flow velocity distribution, the main performance goals in the waterway design process, were satisfied.

Improving the Measurement Uncertainty of Altitude Test Facility for Gas Turbine Engines (가스터빈엔진 고공성능시험설비의 측정불확도 개선)

  • Lee, Dae-Sung;Yang, In-Young;Jun, Yong-Min;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1496-1502
    • /
    • 2002
  • An Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute in October 1999 and has been being operated for altitude testing of gas turbine engines of 3,000 Ibf class or less. The AETF has been calibrated using several engines such as J69 of Teledyne Co. as a facility checkout engine. Uncertainty analyses on the air flow rate and thrust were performed using the test results, according to ASME PTC 19.1-1998. Several modifications on the facility and test method were made in order to improve the measurement uncertainty to a satisfactory level over the whole operating envelop. Spatial distributions of pressure and temperature were measured, sensors were substituted by more accurate ones, inlet duct was modified to refine the flow quality, and pressure control logic was revised to remove the cell pressure fluctuation. As a result, the uncertainty of the air flow measurement was improved by 0.1% over all the test conditions, and the net thrust measurement by up to 3%. The improved measurement uncertainties of air flow and thrust are 0.68~O.73% and 0.4~1.3%, respectively.

An Investigation into the effect of friction in the split hopkinson pressure bar (SHPB) test by numerical experiments (수치해석을 이용한 SHPB 시험의 마찰영향 분석)

  • Cha, Sung-Hoon;Shin, Myoung-Soo;Shin, Hyun-Ho;Kim, Jong-Bong
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.204-209
    • /
    • 2008
  • The interest in the mechanical behavior of materials at high strain rates has increased in recent years, and by now it is well known that mechanical properties can be strongly influenced by the speed of applied load. The split Hopkinson pressure bar (SHPB) has been widely used to determine mechanical properties of materials at high loading rates. However, to ensure test reliability, measurement error source must be accounted for and eliminated. During experiment, the specimens were located between the incident and the transmit bar. The presence of contact frictions between the test bars and specimen may cause errors. In this work, numerical experiments were carried out to investigate the effect of friction on test results. In SHPB test, the measured stress by the transmitted bar is assumed to be flow stress of the test specimen. Through the numerical experiments, however, it is shown that the measured stress by the transmit bar is axial stress components. When, the contact surface is frictionless, the flow stress and the axial stress of the specimen are about the same. When the contact surface is not frictionless, however, the flow stress and the axial stress are not the same anymore. Therefore, the measured stress by the transmitted bar is not flow stress. The effect of friction on the difference between flow stress and axial stress is investigated.

  • PDF

Effects of Hand Acupuncture Therapy on Sleep Quality in Sleep Disrupted Adults - Verification by Polysomnography and Cerebral Blood Flow Test - (수지요법이 수면장애를 가진 성인의 수면의 질에 미치는 효과 - 수면다원검사 및 뇌혈류 검사를 통한 검증 -)

  • Hwang, Eun-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.7
    • /
    • pp.1108-1118
    • /
    • 2007
  • Purpose: The purpose of this study was to identify the effects of hand acupuncture therapy on sleep quality by means of a sleep questionnaire, polysomnography and a cerebral blood flow test in $30{\sim}59$ year old adults. Methods: The study was a sham controlled design. Twenty-two adults were assigned to the pellet stimulating group (11) or sham group (11). The pellet stimulating group received hand acupuncture therapy using New Seoam Press Pellets number 1 for 4 weeks. On the other hand, the sham group used the same Adhesive tape in terms of shape, size and quality as New Seoam Press Pellets number 1 for 4 weeks. A Transcranial Doppler Ultrasonography and Carotid Duplex Ultrasonography examination were used for evaluating cerebral blood flow. Data was analyzed using the SPSS 12.0 version program with $X^2-test$, Fisher's exact test and Mann Whitney U-test. Results: In the pellet stimulating group, subjective sleep quality significantly improved more than that of the sham group. Among the sleep indices of the polysomnography, total sleep time and sleep latency of the sham group significantly improved. The cerebral blood flow test didn't show any differences. Conclusion: These results suggest that hand acupuncture therapy is effective for subjective sleep improvement only, not polysomnographical sleep indices and cerebral blood flow.