• 제목/요약/키워드: Flow Sensor

검색결과 870건 처리시간 0.029초

Inferring Pedestrian Level of Service for Pathways through Electrodermal Activity Monitoring

  • Lee, Heejung;Hwang, Sungjoo
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.1247-1248
    • /
    • 2022
  • Due to rapid urbanization and population growth, it has become crucial to analyze the various volumes and characteristics of pedestrian pathways to understand the capacity and level of service (LOS) for pathways to promote a better walking environment. Different indicators have been developed to measure pedestrian volume. The pedestrian level of service (PLOS), tailored to analyze pedestrian pathways based on the concept of the LOS in transportation in the Highway Capacity Manual, has been widely used. PLOS is a measurement concept used to assess the quality of pedestrian facilities, from grade A (best condition) to grade F (worst condition), based on the flow rate, average speed, occupied space, and other parameters. Since the original PLOS approach has been criticized for producing idealistic results, several modified versions of PLOS have also been developed. One of these modified versions is perceived PLOS, which measures the LOS for pathways by considering pedestrians' awareness levels. However, this method relies on survey-based measurements, making it difficult to continuously deploy the technique to all the pathways. To measure PLOS more quantitatively and continuously, researchers have adopted computer vision technologies to automatically assess pedestrian flows and PLOS from CCTV videos. However, there are drawbacks even with this method because CCTVs cannot be installed everywhere, e.g., in alleyways. Recently, a technique to monitor bio-signals, such as electrodermal activity (EDA), through wearable sensors that can measure physiological responses to external stimuli (e.g., when another pedestrian passes), has gained popularity. It has the potential to continuously measure perceived PLOS. In their previous experiment, the authors of this study found that there were many significant EDA responses in crowded places when other pedestrians acting as external stimuli passed by. Therefore, we hypothesized that the EDA responses would be significantly higher in places where relatively more dynamic objects pass, i.e., in crowded areas with low PLOS levels (e.g., level F). To this end, the authors conducted an experiment to confirm the validity of EDA in inferring the perceived PLOS. The EDA of the subjects was measured and analyzed while watching both the real-world and virtually created videos with different pedestrian volumes in a laboratory environment. The results showed the possibility of inferring the amount of pedestrian volume on the pathways by measuring the physiological reactions of pedestrians. Through further validation, the research outcome is expected to be used for EDA-based continuous measurement of perceived PLOS at the alley level, which will facilitate modifying the existing walking environments, e.g., constructing pathways with appropriate effective width based on pedestrian volume. Future research will examine the validity of the integrated use of EDA and acceleration signals to increase the accuracy of inferring the perceived PLOS by capturing both physiological and behavioral reactions when walking in a crowded area.

  • PDF

식품계량 및 포장 공정 로봇 적용 자동화 시스템 개발을 위한 3D 시뮬레이션 연구 (3D Simulation Study to Develop Automated System for Robotic Application in Food Sorting and Packaging Processes)

  • 백승훈;오승일;권기현;김태형
    • 한국정보전자통신기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.230-238
    • /
    • 2023
  • 식품제조 중소기업들은 원물 투입부터 최종 팔렛타이징까지 대부분 노동집약적이고 수작업으로 구성되어 있다. 최근 로봇과 센서 데이터 기술요소 적용으로 스마트화 디지털화로 변화하는 추세이다. 본 연구에서는 식품제조기업에서 적용 설비 역량보다 작업자가 속도를 따라가지 못하는 반복작업 공정 2가지를 선정하였으며, 이를 3D 시뮬레이션을 활용하여 개선 효과성을 규명하고자 한다. 꼬치 조립 후 작업자들이 계량 후 포장하는 공정과 무작위로 공급되는 냉동식품류를 계량-내·외포장-팔렛타이징 일괄 수작업 공정 2개를 선정하였다. 가동률, 생산량, 투입 작업자 수를 검증 지표로 선정하였다. 3D 개선 공정 시뮬레이션 결과 생산량은 각각 기존보다 13.5%, 56.8% 증가했으며, 특히 팔렛타이징 로봇 적용 공정에서 높은 효과성을 보였다. 두 공정 모두 가동률과 투입인력 수는 감소함에 따라 작업자에게 피로도가 높은 공정을 로봇으로 대체 적용할 수 있어 작업 과부하를 개선할 수 있는 결과를 나타냈다. 본 연구 결과를 바탕으로 3D 시뮬레이션을 활용하여 식품계량 및 포정 공정에 로봇을 도입함으로써 개선된 공정의 성능을 정량적으로 사전 검증의 가능성을 확인할 수 있었다.

측정장치의 compliance 유무가 복합레진의 중합수축음력의 측정에 미치는 영향 (EFFECT OF INSTRUMENT COMPLIANCE ON THE POLYMERIZATION SHRINKAGE STRESS MEASUREMENTS OF DENTAL RESIN COMPOSITES)

  • 서덕규;민선홍;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제34권2호
    • /
    • pp.145-153
    • /
    • 2009
  • 본 연구에서는 측정장치의 compliance유무가 복합레진의 중합수축응력 측정에 미치는 영향을 알아보았다. 변위센서, cantilever load cell과 부궤환 (negative feedback) 시스템을 적용하여 compliance를 허용하는 것과 허용하지 않는 두 가지 모드로 중합수축응력의 측정이 가능한 stress-strain analyzer를 제작하였다. 한 종의 flowable (Filtek Flow: FF) 복합레진과 두 종의 universal hybrid (Z100: Z1 and Z250: Z2) 복합레진이 사용되었다. Load cell의 끝과 base plate에 고정된 직경 3.0 mm의 금속 막대에 silane을 처리하였다. 1.0 mm의 거리로 고정한 두 개의 금속 막대 사이 에 복합레진을 적용한 후 광중합을 하였다. 복합레진의 수직 중합수축률과 중합수축응력을 10 분 동안 기록하였고 인장탄성계수도 구하였다. 통계처리는 일원분산분석과 paired t-test를 시행하였고 95% 유의수준에서 Tukey's test로 사후 검정하였다. 측정된 중합수축 응력은 재료와 compliance의 유무에 따라 큰 차이를 보였다. Compliance를 허용한 모드에서 중합수축응력은 FF: 3.11 (0.13)이 가장 컸으며 Z1: 2.91 (0.10), Z2: 1.94 (0.09) Mpa의 순서였다. 측정장치의 compliance를 허용하지 않은 경우에는 Z1 17.08 (0.89)이 가장 컸고 FF: 10.11 (0.29), Z2: 9.46 (1.63) MPa의 순이었다. 또한 Z1, Z2, FF의 인장탄성계수는 각각 2.31 (0.18), 2.05 (0.20), 1.41 (0.11) GPa 이었다. 중합수축응력은 compliance mode에서는 복합레진의 수직 중합수축률이 주요 영향 요인이었으며, compliance를 배제한 모드에서는 탄성계수의 효과가 지배적이었다.

드론기반 시공간 초분광영상 및 RGB영상을 활용한 추적자 농도분석 기법 개발 (Development of tracer concentration analysis method using drone-based spatio-temporal hyperspectral image and RGB image)

  • 권영화;김동수;유호준;한은진;권시윤;김영도
    • 한국수자원학회논문집
    • /
    • 제55권8호
    • /
    • pp.623-634
    • /
    • 2022
  • 하천 주변 친수구역 조성, 4대강 사업 등과 같은 하천정비 사업으로 인해 하천의 흐름특성은 계속적으로 변동하고 있으며, 각종 오염물질 유입으로 인한 수질사고의 위험이 높아지고 있다. 수질사고 발생시 하천의 흐름특성을 고려해 오염물질의 농도 및 도달시간을 예측해 신속한 방제작업으로 하류로의 영향을 최소화해야한다. 이러한 오염물질의 거동을 추적하기 위해서는 하천의 구간별 확산계수, 분산계수 산정이 필요하며 그중 분산계수는 용존성 오염물질의 확산범위 해석에 사용된다. 오염물질의 거동을 추적하기 위한 기존 실험적 연구사례들은 많은 인력과 비용이 소요되고, 한정적인 장비의 운용으로 공간적으로 높은 해상도의 자료 취득이 어려웠다. 최근에는 RGB드론을 이용한 오염물질의 추적연구가 수행되었지만, RGB영상 역시 분광정보를 한정적으로 수집한다는 한계가 있다. 본 연구에서는 기존 연구들의 한계점들을 보완하기 위해 드론을 활용한 원격탐사 플랫폼에 초분광센서를 탑재하여 기존 접촉식 측정보다 시간적, 공간적으로 고해상도의 자료를 수집하였다. 수집된 시공간(Spatio-temporal) 초분광영상을 활용해 추적자의 농도를 산정하고, 횡분산계수를 도출하였다. 향후 연구를 통해 드론 플랫폼의 한계를 극복하고, 분산계수 산정 기술을 고도화하면 수계로 유출되는 각종 오염물질의 감지 및 다양한 수질항목 및 하천인자의 변화량 감지가 가능할 것으로 기대된다.

전염병의 경로 추적 및 예측을 위한 통합 정보 시스템 구현 (Implementation of integrated monitoring system for trace and path prediction of infectious disease)

  • 김은경;이석;변영태;이혁재;이택진
    • 인터넷정보학회논문지
    • /
    • 제14권5호
    • /
    • pp.69-76
    • /
    • 2013
  • 세계적으로 전파력과 병원성이 높은 신종인플루엔자, 조류독감 등과 같은 전염병이 증가하고 있다. 전염병이란 특정 병원체(pathogen)로 인하여 발생하는 질병으로 감염된 사람으로부터 감수성이 있는 숙주(사람)에게 감염되는 질환을 의미한다. 전염병의 병원체는 세균, 스피로헤타, 리케차, 바이러스, 진균, 기생충 등이 있으며, 호흡기계 질환, 위장관 질환, 간질환, 급성 열성 질환 등을 일으킨다. 전파 방법은 식품이나 식수, 곤충 매개, 호흡에 의한 병원체의 흡입, 다른 사람과의 접촉 등 다양한 경로를 통해 발생한다. 전 세계의 대부분 국가들은 전염병의 전파를 예측하고 대비하기 위해서 수학적 모델을 사용하고 있다. 하지만 과거와 달리 현대 사회는 지상과 지하 교통수단의 발달로 전염병의 전파 속도가 매우 복잡하고 빨라졌기 때문에 우리는 이를 예방하기 위한 대책 마련의 시간이 부족하다. 그러므로 전염병의 확산을 막기 위해서는 전염병의 전파 경로를 예측할 수 있는 시스템이 필요하다. 우리는 이러한 문제를 해결하기 위해서 전염병의 실시간 감시 및 관리를 위한 전염병의 감염 경로 추적 및 예측이 가능한 통합정보 시스템을 구현하였다. 이 논문에서는 전염병의 전파경로 예측에 관한 부분을 다루며, 이 시스템은 기존의 수학적 모델인 Susceptible - Infectious - Recovered (SIR) 모델을 기반으로 하였다. 이 모델의 특징은 교통수단인 버스, 기차, 승용차, 비행기를 포함시킴으로써, 도시내 뿐만 아니라 도시간의 교통수단을 이용한 이동으로 사람간의 접촉을 표현할 수 있다. 그리고 한국의 지리적 특성에 맞도록 실제 자료를 수정하였기 때문에 한국의 현실을 잘 반영할 수 있다. 또한 백신은 시간에 따라서 투여 지역과 양을 조절할 수 있기 때문에 사용자가 시뮬레이션을 통해서 어느 시점에서 어느 지역에 우선적으로 투여할지 백신을 컨트롤할 수 있다. 시뮬레이션은 몇가지 가정과 시나리오를 기반으로 한다. 그리고 통계청의 자료를 이용해서 인구 이동이 많은 주요 5개 도시인 서울, 인천국제공항, 강릉, 평창, 원주를 선정했다. 상기 도시들은 네트워크로 연결되어있으며 4가지의 교통수단들만 이용하여 전파된다고 가정하였다. 교통량은 국가통계포털에서 일일 교통량 자료를 입수하였으며, 각도시의 인구수는 통계청에서 통계자료를 입수하였다. 그리고 질병관리본부에서는 신종인플루엔자 A의 자료를 입수하였으며, 항공포털시스템에서는 항공 통계자료를 입수하였다. 이처럼 일일 교통량, 인구 통계, 신종인플루엔자 A 그리고 항공 통계자료는 한국의 지리적 특성에 맞도록 수정하여 현실에 가까운 가정과 시나리오를 바탕으로 하였다. 시뮬레이션은 신종인플루엔자 A가 인천공항에 발생하였을 때, 백신이 투여되지 않은 경우, 서울과 평창에 각각 백신이 투여된 경우의 3가지 시나리오에 대해서, 감염자가 피크인 날짜와 I (infectious)의 비율을 비교하였다. 그 결과 백신이 투여되지 않은 경우, 감염자가 피크인 날짜는 교통량이 가장 많은 서울에서 37일로 가장 빠르고, 교통량이 가장 적은 평창에서 43일로 가장 느렸다. I의 비율은 서울에서 가장 높았고, 평창에서 가장 낮았다. 서울에 백신이 투여된 경우, 감염자가 피크인 날짜는 서울이 37일로 가장 빨랐으며, 평창은 43일로 가장 느렸다. 그리고 I의 비율은 강릉에서 가장 높으며, 평창에서 가장 낮았다. 평창에 백신을 투여한 경우, 감염자가 피크인 날짜는 37일로 서울이 가장 빠르고 평창은 43일로 가장 느렸다. I의 비율은 강릉에서 가장 높았고, 평창에서는 가장 낮았다. 이 결과로부터 신종인플루엔자 A가 발생하면 각 도시는 교통량에 의해 영향을 받아 확산된다는 것을 확인할 수 있다. 따라서 전염병 발생시 전파 경로는 각 도시의 교통량에 따라서 달라지므로, 교통량의 분석을 통해서 전염병의 전파 경로를 추적하고 예측함으로써 전염병에 대한 대책이 가능할 것이다.

현장관측 및 원격탐사 자료를 이용한 북동 멕시코 만에서 El $Ni\tilde{n}o$와 La $Ni\tilde{n}a$ 기간 동안 표층 입자성 유기탄소의 시/공간적 변화 연구 (Determining Spatial and Temporal Variations of Surface Particulate Organic Carbon (POC) using in situ Measurements and Remote Sensing Data in the Northeastern Gulf of Mexico during El $Ni\tilde{n}o$ and La $Ni\tilde{n}a$)

  • 손영백
    • 한국해양학회지:바다
    • /
    • 제15권2호
    • /
    • pp.51-61
    • /
    • 2010
  • 북동 멕시코 만에서 particulate organic carbon(POC)의 시/공간적 변화를 조사하기 위하여, 1997년 11월부터 2000년 8월까지 총 9번의 관측이 이루어 졌으며, 같은 기간 동안 위성자료(해색, 표층수온, 해면고도이상, 표층바람)와 주요 강들 의 유출량이 조사되었다. POC 농도는 내 대륙붕과 미시시피 하구 역에서 높은 값을 (>100 $mg/m^3$) 나타내고 대륙붕과 대륙사면으로 가면서 감소된다. POC의 경년 변화는 상대적으로 1997과 1998년(El $Ni\tilde{n}o$)이 1999과 2000년(La $Ni\tilde{n}a$) 보다 상대적으로 증가되어 나타난다. 이런 현상은 미시시피강 및 다른 주요 강들에 영향을 주는 강우량 변화에 따른 담수 유 입의 변화와 직접적으로 연관되어 있으며, 강우량 변화는 ENSO 현상과 같은 세계 기후변화와 관련이 있는 것으로 사료 된다. 북동 멕시코 만 연안으로 유입되는 주요 강들의 방류량은 초봄에 증가되어 여름과 가을에 감소되지만, 공간적으로 확장된 높은 농도의 POC 분포는 여름 조사기간에서 관측되고, 낮은 농도 및 제한된 확산은 가을과 초 봄 관측에서 나타 난다. 여름철 동안 상대적인 강의 유출량은 봄에 비하여 현저하게 감소하지만, 증가된 표층수온은 수층을 강하게 성층화 시키고 표층에서 부력을 증가시킨다. 이런 조건에서 고농도의 POC를 함유하는 저염수는 상부 대륙사면까지 확장되고 이 는 Loop Current와 Loop Current Eddies의해서 조절된다. 봄과 가을 동안 유출량은 보통이거나 이상을 보이지만, 증가된 바람과 낮은 표층수온으로 인하여 수직적 혼합을 유발하고 이는 높은 농도의 POC를 내 대륙붕에 제한 시키는 것으로 사료된다.

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권2호
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

초분광 영상을 활용한 하천수 혼합 유해화학물질 표준 분광라이브러리 구축 방안 (A standardized procedure on building spectral library for hazardous chemicals mixed in river flow using hyperspectral image)

  • 권영화;김동수;유호준
    • 한국수자원학회논문집
    • /
    • 제53권10호
    • /
    • pp.845-859
    • /
    • 2020
  • 최근 기후변화와 여름철 고온 등으로 인한 녹조현상, 사고발생으로 인한 화학물질 및 유류 유출 등 수질오염과 관련된 사회적 관심이 높아지고 있다. 수질오염 사례 중 화학사고로 인한 유해화학물질 유출은 인체에 접촉시 인체에 악영향을 끼치며, 대기·수질·토양을 오염시키고 주변 농작물의 변색이나 괴사를 유발하는 등 생태환경에 직접적인 피해가 발생한다. 하천으로 유출가능성이 있는 화학물질은 무색의 수용성인 경우가 많아 육안으로 유출 사실을 확인하기가 어렵다. 화학사고 발생시 화학물질의 탐지는 간이접촉식탐지장비를 이용하거나 화학물질의 유출이 우려되는 곳에 검출센서를 설치해 사고를 감시하고 있다. 이러한 접촉식 센서는 현장인력에 의존적이고, 설치식 검출센서 또한 제한적으로 설치되어 미설치 지역에 대한 능동적 탐지가 어렵다는 한계가 있다. 한편 최근 초분광 영상을 활용하여 물질 고유의 분광특성을 분석함으로써 토지피복, 식생, 수질 등의 식별에 활용되고 있다. 따라서 초분광 센서를 활용한 화학물질 감지 가능성도 보여주고 있지만 연구는 미비한 실정이다. 본 연구에서는 수계로 유출되는 유해화학물질을 식별하기 위하여 접촉식 탐지 기술의 한계를 극복할 수 있는 원격탐사기법과 최신 센서기술을 활용하였다. 유해화학물질 18종을 대상으로 초분광 영상을 이용한 상호 구분이 가능한 지 확인하고자 해당 유해화학물질의 초분광 영상을 촬영하여 분광라이브러리를 구축하였다. 향후 연구를 통해 유해화학물질 분광라이브러리 데이터베이스를 확대하고, 하천 적용에 대한 검증을 실시한 후 실시간 모니터링에 적용할 경우 신속한 화학사고 발생여부 감지 및 대응에 활용할 수 있을 것으로 기대된다.

Modern Paper Quality Control

  • Olavi Komppa
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2000년도 제26회 펄프종이기술 국제세미나
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

일본잎갈나무와 리기다소나무 고사목의 호흡속도: 고사목의 부후등급과 이화학적 특성의 영향 (Coarse Woody Debris (CWD) Respiration Rates of Larix kaempferi and Pinus rigida: Effects of Decay Class and Physicochemical Properties of CWD)

  • 이민규;권보람;김성근;윤태경;손요환;이명종
    • 한국산림과학회지
    • /
    • 제108권1호
    • /
    • pp.40-49
    • /
    • 2019
  • 고사목(CWD)은 산림생태계 구성요소의 하나로서 산림의 에너지 흐름과 물질순환에서 주요한 역할을 한다. 특히 고사목은 탄소를 격리하는 장기 저장고로서, 산림에서 대기로 방출되는 탄소의 속도를 지연시키는 측면에서 고사목의 호흡속도를 구명하는 것은 의의가 크다. 따라서 본 연구는 온대중부지역의 일본잎갈나무와 리기다소나무 고사목을 대상으로 호흡속도를 측정하고, 호흡속도에 영향을 미치는 인자(밀도, 함수율, 탄소농도, 질소농도 및 C/N비)의 영향력을 파악하였다. 2018년 여름, 우리나라 중부지역 14개 임분에서 부후등급 별로 시료를 채취하고, 실험실에서 휴대용 이산화탄소 센서를 부착한 밀폐형 챔버를 이용하여 고사목 호흡을 측정하였다. 두 수종 모두 부후가 진행함에 따라 고사목 밀도는 감소하였으며, 함수율은 증가했다. 또한 탄소농도는 부후등급에 따라 유의성을 나타내지 않았으나, 질소농도는 증가하고 C/N비는 감소하는 경향을 보였다. 일본잎갈나무의 경우 부후 IV등급까지 고사목의 호흡속도가 유의하게 증가하였지만, 리기다소나무에서는 부후 II등급까지 증가 후 평형상태를 보였다. 따라서 탄소농도를 제외하고, 모든 인자들이 호흡속도와 유의한 상관관계를 나타냈으며, 단계적 회귀분석의 결과, 두 수종 모두 함수율이 고사목 호흡속도에 가장 영향을 미치는 인자로 나타났다. 이와 같이 고사목의 수분은 미생물의 활성도를 높여 호흡속도에 영향을 미치며, 온도와 광 환경 등 복잡하게 연결된 환경인자들과 밀접한 관계에 있으므로 향후 이들의 상호관계 및 수분의 시계열적패턴 추정에 대한 지속적인 연구가 필요하다.