• Title/Summary/Keyword: Flow Reduction

Search Result 2,803, Processing Time 0.03 seconds

Wind Tunnel Test of 2D Model for Plasma Flow Control using DBD Plasma Actuator (DBD 플라즈마 구동기를 이용한 2차원 모델의 플라즈마 유동제어 풍동시험)

  • Yun, Su-Hwan;Kim, Tae-Gyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.527-528
    • /
    • 2012
  • DBD (Dielectric Barrier Discharge) plasma actuator was designed for aerodynamic drag reduction using plasma flow control, and the drag reduction was measured by wind-tunnel tests using 2D test model. At the zero wind velocity, the plasma flow control had no effect on the drag reduction because the flow separation and surface friction drag were not occurred. At the wind velocity of 2m/s, 9.7% of drag was reduced by the flow separation control. The drag reduction decreased as the wind velocity increased.

  • PDF

A Study on the Operational Optimization of Turbo-Expander Pressure Reduction System to the Natural Gas Flow Rates (천연가스 유량변화에 따른 터보팽창기 감압시스템 운전 최적화에 관한 연구)

  • Yoo, Han Bit;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.72-79
    • /
    • 2015
  • Electricity can be generated when the natural gas passes through a turbo-expander pressure reduction system at natural gas pressure reduction stations. Efficiency of the turbo-expander depends on the ratio of the natural gas flow rates to the design flow rate of the turbo-expander. Therefore, the optimal conditions for the operation of the pressure reduction system can be determined by controlling the natural gas flow rates. In this study, we have calculated the electric energy generation depending on the natural gas flow rates at the two low-pressure reduction stations when the pressure of the natural gas is reduced from 17.5 bar to 8.5 bar and have found the optimal conditions for the turbo-expander pressure reduction system through the comparison with the calculation results. The turbo-expander generates the electric power efficiently for the high natural gas flow rates which variations are slight. The determined design flow rate of the turbo-expander has the highest coverage of the natural gas flow rates. The electricity generation is calculated as much as 9 MW(B station) and 12 MW(D station) at each pressure reduction station.

A Study on the Drag Reduction with Polymer Additives (고분자물질(高分子物質) 첨가(添加)에 따른 마찰저항감소(摩擦抵抗減少)에 관한 연구(硏究))

  • Kim, J.G.;Cha, K.O.;Choi, H.J.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.198-207
    • /
    • 1996
  • It is well known that drag reduction in single phase liquid flow is affected by polymer material, molecular weight, polymer concentration, pipe diameter, and flow velocity. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to present cavitation which occurs in pump impellers. But the research of drag reduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction, mean liquid velocity, and turbulent intensity whether polymer is added in the horizontal two phase system or not. Experiment has been conducted in a test section with the inner diameter of 24mm and the length of 1,500mm. The polymer materials used are two kinds of polyacrylamide[PAAM] and co-polymer[A611P]. The polymer concentration was varied with 50, 100 and 200 ppm under the same experimental conditions. Experimental results showed that the drag reduction of co-polymer is higher than that of polyacrylamide. Mean liquid velocities increased as polymer was added, and turbulent intensity decreased inversely near the pipe wall.

  • PDF

A Study on the Characteristics of Flow with Polymer Additives (고분자물질 첨가에 의한 유동특성에 관한 연구)

  • 차경옥;김재근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.176-186
    • /
    • 1996
  • The phenomena of drag reduction using small quantities of a liner macromolecules has attracted the attention of many experimental investigations. On the other hand drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to flow with cavitation which occurs pump impellers. But the research on dragreduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction, mean liquid velocity and turbulent intensity whether polymer additives a horizontal single and two phase system or not. Flow pattern of air-water two phase flow was classified by electrical conductivity probe signal. Velocities and turbulent intensities of signal were measured simultaneously with a Hot-film anemometer.

  • PDF

The Study on the Drag Reduction for Gas/Liquid Two Phase Flow (기-액(氣-液) 2상유동(二相流動)시 항력(抗力)에 관(關)한 연구(硏究))

  • Cha, K.O.;Oh, Y.K.;Kim, J.G.
    • Journal of ILASS-Korea
    • /
    • v.1 no.3
    • /
    • pp.20-28
    • /
    • 1996
  • It is well known that drag reduction in single phase liquid flow is affected by polymer material, molecular weight, polymer concentration, pipe diameter, and flow velocity. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to present cavitation which occurs in pump impellers. But the research of drag reduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction whether polymer is added in the horizontal two phase system or not. Experiment has been conducted in a test section with 24 m of the inner diameter and 1,500 mm of the length. The used polymer materials are two kinds of polyacrylamide[PAAM] and co-polymer[A611P]. The polymer concentration was varied with 50, 100 and 200 ppm under the same experimental conditions. Experimental results were shown that the drag is higher reduced by co-polymer rather than polyanylamide.

  • PDF

A Cause Analysis on the Reduction of Stream Flow for the Cheongdocheon (청도천의 건천화 원인분석)

  • Lee, Sang-Ho;Park, Jong-Pyo;Lee, Jung-Min;Cho, Hyo-Seob
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.1069-1082
    • /
    • 2003
  • The Cheongdocheon has the reaches under reduction of stream flow. We analysed the cause of the reduction. We investigated the current status of facilities for agricultural water use. We also compared the discharge measurements with the results from the continuous simulation of watershed runoff The satellite image was a tool to find some reaches of stream flow reduction under doubt. Agricultural reservoirs block up the stream and water does not flow over the reservoirs except by storm. They also discharge water through diversion channels and the water diverted does not flow through the natural stream. Farmers directly take water from the stream by weirs. The infiltration gallery of water below the stream ground makes the reach dryness perfect in Kamakchon. These are causes of the stream flow reduction. The discharge measurements are less than the simulation results of watershed runoff, and we guess that the reaches investigated have dried. We found the reaches of stream flow reduction that were under doubt from some KOMPSAT satellite images with the resolution of 6.6 m. Then, we confirmed the reduction of stream flow by a field investigation. All the above reaches have infiltration galleries of water below the stream ground. The research results are a case study on the cause analysis on the reduction of stream flow. One can obtain the KOMPSAT image for a low price and can get prior information to find the doubtful reach of stream flow reduction.

Numerical Analysis of Flow-Induced Noise and Fan Performance in Suction Nozzle of a Vacuum Cleaner with a Double-Blade Fan (이중 블레이드 팬이 장착된 진공청소기 흡입 노즐내 유로 유동 소음 및 팬 성능 해석)

  • Park, I-Sun;Sohn, Chae-Hoon;Lee, Sung-Cheol;Oh, Jang-Keun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2632-2637
    • /
    • 2007
  • Rotary performance and flow resistance induced by each element in suction nozzle of a vacuum cleaner with a double-blade rotary fan are investigated numerically and its relation with flow-induced noise and rotary performance is examined. Flow resistance and vorticity in suction nozzle are calculated and it is found that they are closely related with flow-induced noise. Gap between double blades, adoption of cross-flow fan, enlargement of flow inlet area, and optimization of blade number are tested for noise reduction. Finally, the effects of each method are verified experimentally. It is found that several combinations of the proposed methods can be adopted for noise reduction although the degree of reduction is not much.

  • PDF

Evaluation of Flowfield and Flow Losses insied Axial Turbomachinery Using Numerical Calculation [Evaluation of Tip Leakage Loss and Reduction of Efficiency by Tip Clearance] (수치계산에 의한 축류터보기계의 유동장과 유동온실의 평가 III [회전차 익말단의 누설손실과 효율저하에 대한 평가])

  • Ro, Soo-Hyuk;Cho, Kang-Rae
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.240-247
    • /
    • 1998
  • Leakage vortices formed near blade tip causes an increase of total pressure loss near casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of tip clearance. In this study, the three-dimensional flowfields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and attack angle on the leakage vortex and overall performance, and the less distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss by tip clearance were evaluated using numerical results and aprroximate equations were presented to evaluate the reduction of rotor efficiency by tip leakage flow.

  • PDF

Suboptimal Control for Drag Reduction in Turbulent Pipe Flow (환형관내 유동에서의 항력감소를 위한 준최적 제어)

  • Choi, Jung-Il;Xu, Chun-Xiao;Sung, Hyung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.377-382
    • /
    • 2001
  • A suboptimal control law in turbulent pipe flow is derived and tested. Two sensing variables ${\partial}p/{\partial}{\theta}\;|_w\;and\;{\partial}{\upsilon}_{\theta}/{\partial}r\;|_w$ are applied with two actuations ${\phi}_{\theta}$ and ${\phi}_r$. To test the suboptimal control law, direct numerical simulations of turbulent pipe flow at $Re_r=150$ are performed. When the control law is applied, a $13{\sim}23%$ drag reduction is achieved. The most effective drag reduction is made at the pair of ${\partial}{\upsilon}_{\theta}/{\partial}r\;|_w$ and ${\theta}_r$. An impenetrable virtual wall concept is useful for analyzing the near-wall suction and blowing. The virtual wall concept is useful for analyzing the near-wall behavior of the controlled flow. Comparison of the present suboptimal control with that of turbulent channel flow reveals that the curvature effect is insignificant.

  • PDF

The Drag Reduction and Convective Heat Transfer Characteristics of Two-Phase Flow with Polymer Additives (고분자 물질 첨가에 의한 2상 유동의 마찰 항력 감소와 대류 열전달 특성)

  • Lee, Dong-Sang;Kim, Jae-Guen;Cha, Kyong-Ok
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.71-76
    • /
    • 2000
  • This experimental study was conducted to figure out the drag reduction and convective heat transfer in vertical downward two-phase flow with polymer additives. The drag reduction effect were analyzed by using the difference of the pressure drop between the flow with polymer additives and without it. Experimental results show that the pressure drop with polymer additives is less than the pressure drop without polymer in vertical downward two-phase flow. And the convective heat transfer has decreased with increasing the polymer concentration in vertical downward two-phase flow.

  • PDF