• 제목/요약/키워드: Flow Rate of Hot Air

검색결과 176건 처리시간 0.023초

소형 황토 찜질방의 온수유량 변화에 대한 온도분포 특성 (Temperature Distribution Characteristics for Changes in Hot Water Flow in A Small Ocher Jjimjilbang)

  • 조동현
    • 한국기계가공학회지
    • /
    • 제19권7호
    • /
    • pp.74-80
    • /
    • 2020
  • The ocher jjimjilbang for a single-person household that will be studied in this study is 2.1 ㎡ in size, and this study was conducted to implement well-being room heating that is beneficial to health by supplying radiant heat provided by hot water during room heating by embedding hot water panels in the walls of the ocher jjimjilbang to configure a hot water circulating system. In addition, the ocher bed and the ocher walls, which have been verified through many study findings and reference materials, were constructed so that the living life with a bed and the ocher jjimjilbang would be implemented simultaneously. As the mass flow rate of the hot water increased, the magnitude of the wall temperature rise thanks to the hot water increased, and as the flow rate of the hot water increased, the transfer rate of the heat transferred from the wall of the ocher jjimjilbang to the air inside the wall of the ocher jjimjilbang increased.

다공의 전열판이 내장된 공기 대 공기 전열교환기의 성능 평가 (Performance Evaluation of Air-to-Air Total Heat Transfer with Rotating Porous Plates)

  • 임태우;조동현
    • 동력기계공학회지
    • /
    • 제11권2호
    • /
    • pp.20-25
    • /
    • 2007
  • The performance of air-to-air heat exchanger has been investigated with rotating porous plates newly developed in this study. With an equal interval of 18 mm, the rotating porous plates are installed inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. Dry bulb temperature is set by adjusting heat supply at heater. In order to measure the temperature distribution of the hot air side inside heat exchanger, the thermocouples are inserted between the plates. The first location of thermocouple is 10mm downstream from the inlet of heat exchanger, and succeeding ten locations are aligned at an equal interval of 18mm. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat transfer rate increased as both air flow rate and RPM of the rotating porous plate increased. It was found that the overall heat transfer coefficient increased with the increase in RPM of porous plate at the conditions of the same air flow rate.

  • PDF

용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰 (Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature)

  • 함정균;김민준;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.

시스템분배기 소음방지 및 성능개선방안 연구 (A Study on the Noise Reduction and Performance Improvement of the Hot Water Distributing System)

  • 김용기;이태원;한태수;유선학
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1055-1060
    • /
    • 2009
  • Noise is one of the major environmental problems in human life. But hot water distributers with the flow rate control valve bring about often noise according to the heating control condition in residential buildings. The sound power level increased as the flow rate and pressure difference increased. And thus, experimental analyses for the flow rate control and the pressure difference control were carried out in this study to reduce the noise emitted from the flow rate control valve. As the results, the flow rate control method using a SMA(Shape Memory Alloy)-valve and the flow rate control system using a pressure difference sensor can be expected to control noise in the region of below 50 dB of sound power level.

  • PDF

태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션 (Dynamic simulation of a solar absorption cooling system)

  • 정시영;조광운
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

복사난방패널의 설계 및 운전을 위한 열적 특성 분석 (An analysis of the thermal characteristics for optimal design and operation of the radiant heating panels)

  • 이태원
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.180-188
    • /
    • 1997
  • The theoretical analysis and experiment with simulator were performed to obtain the temperature distributions in radiant heating panel and heat supply from hot water to heating space for the purpose of the development of comfortable living space from a point of view of the improvement of air quality and the enhancement of system efficiency. The relations of various parameters, such as pipe pitch, room temperature as well as flow rate and temperature of hot water and so on, with the rate of heat supplied, mean temperature and maximum temperature difference at panel surface were discussed. The effects of these parameters were also verified on the thermal performance of heating panel using the relations which could be used for the optimal design and operation of the radiant heating panel.

  • PDF

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

자동차용 정온도 열선식 공기유량계의 개발에 관한 연구 (A study on the development of constant temperature hot wire type air flow meter for automobiles)

  • 조성권;유정열;고상근;김동성
    • 대한기계학회논문집
    • /
    • 제16권12호
    • /
    • pp.2407-2414
    • /
    • 1992
  • 본 연구에서는 정온도 열선식 공기유량계의 전체적인 회로를 구성한 다음, 여 기에 간단한 온도보상시스템을 첨가함으로써 유동온도의 변화에 관계없이 일정한 출력 이 나오도록 하고, 이에 관련된 온도보상시스템의 메카니즘을 규명하고자 한다. 온 도보상시스템은 여러 가지가 알려져 있으나, Drubka(1977)가 열선브릿지에 단지 온도 센서(thermistor)를 삽입하고, 과열비(overheat ratio), 열선의 냉저항과 작동 중의 저항차, 열선의 브릿지상단에서의 출력 중 한 가지를 일정하게 유지시켜 온도보상을 수행하는 방법을 제안하였다. Takagi(1985)는 위의 방법 중 과열비를 일정하게 유지 시키는 방법을 택하고, 출력으로 브릿지상단의 전압이 아닌 열선에 흐르는 전류를 감 지함으로써 더욱 더 간단한 온도보상시스템을 제안하였다. 본 연구는 바로 이 방법 을 채용하여 온도보상을 수행한다.

원심 압축기 임펠러 출구 유동에 관한 실험적 연구 (Experimental study on impeller discharge flow of a centrifugal compressor)

  • 신유환;김광호;손병진
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.483-494
    • /
    • 1998
  • This study describes the characteristics on impeller discharge flow of a centrifugal compressor with vaneless diffuser. Distorted flow at impeller exit was investigated by measuring of unsteady velocity fluctuation using hot-wire anemometer. As a result, a wake region appears near shroud side and moves to suction side and also to hub side as flow rate decreases. Jet, wake, and their boundary region which can be defined in jet-wake flow model are clearly observed at a high flow rate for the flow coefficient of 0.64, however, as flow rate decreases to the flow coefficient of 0.19, the classification of their regions disappears. Turbulence intensity also increases as flow rate decreases. Measurement error from uncertainty analysis is estimated about 4% at the flow coefficient of 0.19

  • PDF

Zr-based 합금을 이용한 hydride heat pump의 작동 특성에 관한 연구 (Study on the Characteristics of Hydride Heat Pump Using the Zr-based Laves Phase Alloys)

  • 이수근;이재영
    • 한국수소및신에너지학회논문집
    • /
    • 제2권1호
    • /
    • pp.39-46
    • /
    • 1990
  • In order to improve the power of hydride heat pump, prototype heat pump was constructed using $Zr_{0.95}Ti_{0.05}Cr_{0.9}Fe_{1.1}$-$Zr_{0.9}Ti_{0.1}Cr_{0.6}Fe_{1.4}$ which had very good hydrogenation properties. The power changed with operating parameter such as cycle time, air flow rate, and temperature of hot air was investigated. The power shows maximum value with cycle time. The power increased with air flow rate and temperature of hot air. The power of the heat pump was $65-72 Kcal/Kg-alloy{\cdot}h$ under optimum operating condition, which was superior to that the system using $LaNi_{0.9}Al_{0.3}-MmNi_{4.15}Al_{0.66}Fe_{0.2}$ alloy pairs.

  • PDF