• Title/Summary/Keyword: Flow Measurements

Search Result 1,813, Processing Time 0.026 seconds

X-ray PIV Measurements of Velocity Field of Blood Flows

  • Lee, Sang-Joon;Kim, Guk-Bae
    • 순환기질환의공학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.28-36
    • /
    • 2006
  • The x-ray PIV method was improved for measuring quantitative velocity fields of real blood flows using a coherent synchrotron x-ray source. Without using any contrast media or seeding particles, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells based on a synchrotron x-ray imaging mechanism. The enhanced x-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit. The quantitative velocity fields of blood flows inside opaque tubes were obtained by applying a 2-frame PIV algorithm to the x-ray images of the blood flows. The measured velocity field data show typical features of blood flows such as the yield stress effect. The non-Newtonian flow characteristics of blood flows were analyzed using the x-ray PIV method and the experimental results were compared with hemodynamic models.

  • PDF

A Study on Applicability of Ultrasonic Flowmeter to Feedwater Flow Measurements in Nuclear Power Plants (원자력발전소의 급수유량 측정에 대한 초음파유량계의 적용성 연구)

  • Yu Sung-Sik;Park Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.1 s.18
    • /
    • pp.57-65
    • /
    • 2003
  • The measurement uncertainties of an ultrasonic flowmeter were analyzed to evaluate its applicability to the measurement of the steam generator feedwater flow-rate in a nuclear power plant. The analyses of measurement uncertainties of a reactor power were also performed with the analyses of feedwater flow measurement uncertainties. Two ultrasonic flowmeters based on a cross-correlation technique and a transit time method were used in this study. The ultrasonic flowmeters were installed on a feedwater pipe line of a typical 1000 MWe Korea-standardized nuclear power plant to take the necessary data. The results have shown that the measurement uncertainties of the ultrasonic flowmeters are adequately smaller than those or a venturi meter. The research has also indicated that the measurement uncertainties of the reactor power based on the ultrasonic flowmeter uncertainties are sufficiently bounded by the uncertainty range usually assumed in nuclear safety analyses.

Flow Characteristics of Piping System Having Various Shapes in Refuse Collecting System (관로 형상에 따른 생활폐기물 이송시스템의 유동특성)

  • Jang, Choon-Man
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.3
    • /
    • pp.13-18
    • /
    • 2009
  • This paper describes flow characteristics in a piping system having various duct shapes on refuse collecting system. A simulator for the refuse collecting system is designed to analyze the flow characteristics in the piping system. The simulator consists of an air intake, a waste chute, circular duct having various shapes, cyclone and turbo blower. The simulator has four different duct shapes: straight, curved, inclined and Y-shaped ducts. Three-dimensional Navier-Stokes analysis is introduced to analyze the pressure loss in the piping system. Throughout the numerical simulation, pressure loss obtained by numerical simulation has a good agreement with the results of experimental measurements. The selected length of curved and Y-ducts for the pressure loss is determined using pressure distributions on the duct. Flow and pressure characteristics in the piping system of the simulator are evaluated by numerical simulation and discussed in detail.

Flow Characteristics in a Cavity Due to a Single Rotating Disk and Co-Rotating Disks (구속된 단일 회전원판과 동시 회전원판 내부의 유동 특성)

  • Won, Chung Ho;Ryu, Goo Young;Cho, Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1192-1200
    • /
    • 1999
  • The present study investigates flow characteristics in a cavity with one rotating disk and co-rotating disks for application to HDD. The experiments are conducted for rotating Reynolds numbers of $5.5{\times}104$ to $1.10{\times}105$ and for gap ratios of 0.059 to 0.175 in a single rotating and 0.047 to 0.094 in co-rotating disk. Time-resolved velocity components and turbulence intensity on the rotating disks are obtained by using LDA measurements. Detailed Knowledge of the flow characteristics is essential to analyze flow vibration and heat transfer and to design head-arm assembly and hub height in HDD. The results indicate that the velocity field in HDD is changed largely by the rotating Reynolds numbers and hub height of the disk.

A Study on the Performance Prediction of Automotive Water Pump with Double Discharge Single Suction (자동차용 양토출 단흡입 워터펌프의 성능 예측에 관한 연구)

  • 허형석;박경석;이기수;원종필
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.27-36
    • /
    • 2004
  • A Numerical analysis has been used to predict the performance in the automotive water pump with double discharge single suction. The influence of parameters such as coolant flow rate, rotational speed, ratio of blade height and clearance has been investigated. Also, the prediction of hydraulic performances such as static pressure rise, shaft power, hydraulic power and pump efficiency is carried out on the water pump including an impeller and a volute casing. A full size water pump test bench has been developed to validate the CFD flow model. Discharge flow rate, suction pressure, discharge pressure, rotational speed and torque measurements are provided. Coolant temperature is 8$0^{\circ}C$, water tank pressure is 1 kgf/$\textrm{cm}^2$ and flow rates vary.

EEG Signal Processing in Japan

  • Utsunomiya, Toshio
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.9-12
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses.

  • PDF

Influence of Unsteady Wake on Flow Characteristics and Heat Transfer from Linear Turbine Cascade (비정상후류가 선형터빈익렬의 유동 특성 및 익형의 열전달에 미치는 영향에 관한 연구)

  • Yoon, Soon-Hyun;Sim, Jae-Kyung;Lee, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.1061-1064
    • /
    • 1998
  • To examine the influence of unsteady wake on the flow and heat transfer characteristics, an experiment has been conducted in a four-vane linear cascade. Flow and heat transfer measurements are made for the inlet Reynolds number of 66000(based on chord length and free-stream velocity). Turbulent intensity and stress were measured using hot wire anemometer, and to measure the convective heat transfer coefficients on the blade surfaces liquid crystal/gold film Intrex technique was used. The disturbance by the unsteady wake is characterized by the unresolved unsteadiness. The unsteady wake enhances the turbulent motion of flow in the cascade passage. It also promotes the boundary layer development and transition. The results show that heat transfer coefficients on the suction surface increase with increasing unresolved unsteadiness.

  • PDF

X-ray PIV Measurements of Velocity Field of Blood Flows

  • Lee, Sang-Joon;Kim, Guk-Bae
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • The x-ray PIV method was improved for measuring quantitative velocity fields of real blood flows using a coherent synchrotron x-ray source. Without using any contrast media or seeding particles, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells based on a synchrotron x-ray imaging mechanism. The enhanced x-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit. The quantitative velocity fields of blood flows inside opaque tubes were obtained by applying a 2-frame PIV algorithm to the x-ray images of the blood flows. The measured velocity field data show typical features of blood flows such as the yield stress effect. The non-Newtonian flow characteristics of blood flows were analyzed using the x-ray PIV method and the experimental results were compared with hemodynamic models.

  • PDF

Performance Analysis of a Reciprocating Compressor using a CFD (CFD를 이용한 왕복동압축기 성능해석)

  • Park, W.S.;Hur, N.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.441-447
    • /
    • 2001
  • This paper presents numerical method of investigating flow characteristics of reed valves of reciprocating compressors. The numerically determined effective flow areas agreed within $5.4\%$ of those obtained from experimental measurements. Reasonably good agreements between the experimental and numerical results have been found, implying that the effective flow and force areas of reed valves could be obtained by CFD alone with enough accuracy. A computer simulation of reciprocating compressor has been performed using a numerical results of reed valves. The calculated P-V diagram shows a good agreement with experimental result.

  • PDF

A Study on Aerodynamic Characteristics with the Supersonic Nozzle Quantity (초음속노즐 수량 변화에 따른 공기역학적 특성의 연구)

  • Lee, Jong-Hoon;Kim, Kyoung-Ryun;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.54-58
    • /
    • 2015
  • The objective of this paper is to investigate the flow characteristics of the multi nozzle. The configurations of the single, the 3- and the 6-nozzle were selected under Mach number of 2.5. Under-expanded pressure ratio such as 1.2, 1.6 and 2.0 were selected to elucidate interference of the free jet. The flow visualization was carried out with the Schlieren system and a supersonic cold-flow system. Also, the flow characteristics were studied computationally with the density measurements. Reasonable agreement between experimental and theoric equation has been achieved qualitatively.