• Title/Summary/Keyword: Flow Injection Analysis

Search Result 715, Processing Time 0.04 seconds

Investigation of the numerical analysis for the ultrasonic vibration in the injection molding

  • Lee, Jae-Yeol;Kim, Nak-Soo
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.1
    • /
    • pp.17-25
    • /
    • 2009
  • We studied the flow characteristics of the polymer melt in the injection molding process with ultrasonic vibration by using the numerical analysis. To minimize the error between the experimental data and numerical result, we presented a methodology using the design of experiments and the response surface method for reverse engineering. This methodology can be applied to various fields to obtain a valid and accurate numerical analysis. Ultrasonic vibration is generally applied between an extruder and the entrance of a mold for improvement the flow rate in injection molding. In comparison with the general ultrasonic process, the mode shape of the mold must be also considered when the ultrasonic vibration is applied on the mold. The mode shape is defined as the periodic and spatial deformation of the structure owing to the effect of the vibration, and it varies greatly according to vibration conditions such as the forcing frequency. Therefore, we considered new index and found the forcing frequency for obtaining the highest flow rate within the range from 20 to 60 kHz on the basis of the index. Ultimately, we presented the methodology for not only obtaining a valid and accurate numerical analysis, but also for finding the forcing frequency to obtain the highest flow rate in injection molding using ultrasonic vibration.

Numerical Analysis of ]Residual Stresses and Birefringence in Injection/Compression Molded Center-gated Disks (I) - Modeling and Basic Results - (사출/압축 성형 Center-Gated 디스크에서의 잔류 응력과 복굴절의 수치 해석 (I) - 모델링 및 기본 결과 -)

  • Lee, Young-Bok;Kwon, Tai-Hun;Yoon, Kyung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2342-2354
    • /
    • 2002
  • The present study has numerically predicted both the flow -induced and thermally-induced residual stresses and birefringence in injection o. injection/compression molded center -gated disks. Analysis system for entire molding process was developed based on an ap propriate physical modeling including a nonlinear viscoelastic fluid model, stress-optical law, a linear viscoelastic solid model, free volume theory for density relaxation phenomena and a photoviscoelasticity and so on. Part I presents physical modeling a nd typical numerical analysis results of residual stresses and birefringence in the injection molded center-gated disk. Thermal residual stress was found to be extensional near the center, compressive near the surface and tend to become toward tensional at the surface. A double-hump profile was obtained across the thickness in birefringence distribution: nonzero birefringence is found to be thermally induced, the outer peak is due to the shear flow and subsequent stress relaxation during the filling stage a nd the inner peak is due to the additional shear flow and stress relaxation during the packing stage. Predicted birefringence including both the flow -induced and thermally-induced one becomes quite similar to the experimental one.

Precision Injection Molding Analysis of Plastic Part with Rectangular Micro-Holes (미세 사각홀을 갖는 플라스틱 부품의 정밀사출성형해석)

  • Lee S. H.;Jung T. S.;Heo Y. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.436-441
    • /
    • 2005
  • In this study, precision injection molding analysis for BGA connector fabrication was performed. A BGA connector model with rectangular micro-holes were introduced to investigate the effect of mirco patterns on the injection molding process. Dual domain(2.5D) mesh and full 3D mesh for BGA connector model were prepared to perform precision injection molding analysis. To verify the Present analysis, experiments of injection molding were performed based on the results of the analysis. It was shown that the type of mesh has a significant effect on the flow pattern of BGA connector

  • PDF

The Prediction of Phase Morphology of Injection Molded Polymer Blends (사출성형된 고분자 블렌드의 형태학적 상구조 예측)

  • Son, Young-Gon
    • Elastomers and Composites
    • /
    • v.39 no.3
    • /
    • pp.193-208
    • /
    • 2004
  • Morphology of injection molded polymer blend was investigated by experimental and theoretical approach. In experiments, the effects of injection speed and injection temperature on the morphology of injection molded MPPO/Nylon 6 blend were investigated. The morphology distribution across the part thickness was clearly observed in injection molded blend. We could observe several distinct regions across the thickness of molded part: skin layer, subskin layer and core region. The skin layer where the dispersed phase is fine and highly deformed to the flow direction is observed to be located near the part surface. The subskin layer located at inner region of the skin layer also observed. In the subskin layer, the dispersed phase is coarser than that of skin layer and deforms to the flow direction. Based on the experimental results, the calculation scheme to predict the morphology of injection molded polymer blend was suggested. The morphology of injection molded polymer blend could be predicted in corporation with the result of flow analysis obtained from commercial software for injection molding process and the theory of drop behavior under the flow. The suggested calculation scheme could predict the effect of injection conditions on the morphology of injection molded parts.

A Study on the Comparison of Flow Analysis and Practical Molding for Automobile Bumper Molding (자동차범퍼의 사출성형 해석결과와 실제 성형품의 비교 연구)

  • Hwang S.H.;Kim C.G.;Ji S.D.;Kim M.K.;Moon Y.B.;Jeong Y.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.357-358
    • /
    • 2006
  • Importance of using an injection molding analysis has been increased. However the application of it has not been increased because the results of analysis do not sometime match to practical molding. Therefore, the difference of flow analysis and practical molding should be decreased. This study presents reasons of the difference for the location of weld-line in the flow analysis and practical molding on automobile bumper molding.

  • PDF

Flow Analysis in a Rotating Container with Axial Injection and Radial Ejection (축방향 유입과 반경방향 유출이 있는 회전용기 내의 유동해석)

  • Park, Jun-Sang;Sohn, Jin-Gug
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.1
    • /
    • pp.49-54
    • /
    • 2011
  • An investigation has been made of a viscous incompressible flow in a circular cylindrical tank. The flow is driven by the spinning bottom disk of tank together with/without central injection and radial uniform-ejection through the sidewall. Numerical solutions of steady and unsteady flows to 3-dimensional Navier-Stokes equation were obtained for several cases of injection strength. In a moderate flow rate of injection, the mass transfer occurs through the boundary layers but, as the flow rate increases, the inner region far from the container walls takes part in mass transfer.

Effects of holding pressure affecting cooling time in injection molding (사출성형시 보압이 냉각시간에 미치는 영향)

  • Mun, Yeong-Bae;Choi, Yun-Sik;Jung, Yeong-Deuk
    • Design & Manufacturing
    • /
    • v.2 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • There occur not only many problems in the injection process but also low quality productivity due to the injection conditions of various injection factors. Injection molding process factors such as molding temperature, injection pressure, flow rate and flow velocity, must be controlled properly in filling and packing phases in the injection molding process. In this study, effects of these factors on the injection molding were investigated through the flow analysis for the holding pressure affecting cooling time. Results of this study would be helpful to setting of holding pressure for optimization of forming condition in order to reduce cooling time in injection molding.

  • PDF

Numerical Analysis for Injection Molding of Precision Electronics Parts Using Three-Dimensional Solid Elements (3차원 입체요소를 사용한 정밀 전자부품의 사출성형 해석)

  • Park, K.;Park, J.H.;Choi, S.R.
    • Transactions of Materials Processing
    • /
    • v.11 no.5
    • /
    • pp.414-422
    • /
    • 2002
  • Most of numerical analyses for injection molding have been based on the Hele Shaw's approximation: two-dimensional flow analysis. In some cases, that approximation causes significant errors due to loss of geometrical information as well as simplification of the flow characteristics along the thickness direction. The present work covers numerical analyses of injection molding using three-dimensional solid elements. The accuracy of the analysis results has been verified through some numerical examples in comparison with the classical shell-based approach. The Proposed approach is then applied to predict product defects and to improve flow characteristics for a precision electronics part. In addition, design of experiment has been utilized in order to find the optimal process conditions for better product quality.

Numerical Analysis for Injection Molding of Precision Electronics Parts using Three-Dimensional Solid Elements (3차원 입체요소를 사용한 정밀 전자부품의 사출성형해석)

  • Park K.;Park J. H.;Choi S. R.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.02a
    • /
    • pp.68-75
    • /
    • 2002
  • Most of numerical analyses for injection molding have been based on the Hele Shaw's approximation: two-dimensional flow analysis. In some cases, that approximation causes significant errors due to loss of geometrical information as well as simplification of the flow characteristics along the thickness direction. The present work covers numerical analyses of injection molding using three-dimensional solid elements. The accuracy of the analysis results has been verified through some numerical examples in comparison with the classical shell-based approach. The proposed approach are then applied to predict product defects and to improve flow characteristics for a precision electronics part. In addition, design of experiment has been utilized in order to find the optimal process conditions for better product quality.

  • PDF

On-line Monitoring of Glucose and Starch by a Flow Injection Analysis Technique (흐름주입분석 기술에 의한 글루코우스와 전분의 온라인 모니터링)

  • 김준홍;박돈희;이종일
    • KSBB Journal
    • /
    • v.16 no.5
    • /
    • pp.459-465
    • /
    • 2001
  • The on-line monitoring technique for the concentrations fo glucose and starch by FIA(Flow Injection Analysis)system was studied. Glucose oxidase(GOD) and amyloglucosidase(AMG) were immboilized on VA-Fpoxy carrier and integrated into the FLA system. The pH, buffer flow rate and temperature were optimized and the effects of salts and metabolites dissolved in the sample on the activity of immobilized enzyme were investigated. GOD-FIA and AMG/GOD-FIA were applied for the on-line monitoring of the glucose and starch in a simulated bioprocess. The on-line measurements of glucose concentrations by GOD-FIA agreed with off-line data well and the AMG/GOD-FIA with single cartidge system took and advantage over the FIA system with two separated cartridges for the on-line monitoring of starch concentrations.

  • PDF