• Title/Summary/Keyword: Flow Detection

Search Result 1,241, Processing Time 0.036 seconds

Visualization of Underexpanded Jet Structure from Square Nozzle

  • Tsutsumi, Seiji;Yamaguchi, Kazuo;Teramoto, Susumu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.408-413
    • /
    • 2004
  • Numerical and experimental investigation were car-ried out to clarify the flow structure of underexpanded jet from a square nozzle. The square nozzle rep-resents one of the clustered combustors of a linear aerospike engine. From the numerical results, the three-dimensional shock wave of the underexpanded square jet was found to be composed of two shocks. One is the intercepting shock which corresponds to the shock observed in two-dimensional planar jet. The other is the recompression shock divided into two types. The expansion fans coming from the nozzle edges interact with each other at the comers of the nozzle exit, and overexpanded regions are generated. Therefore one of the two recompression shocks is formed at the comers of the nozzle exit behind the overexpanded regions. As the jet goes downstream, the overexpanded regions grow larger to coalesce at the symmetry planes. Then, the other type of the recompression shock is generated. The three-dimensional shock structure formed by the intercepting shock and the recompression shocks dominates the expansion of the jet boundary. The shock detection algorithm us-ing CFD results was developed to reveal the relation between the shock waves and the jet boundary, and it was found that the cross-sectional jet shape becomes cross-shape. The key features observed in the numerical investigation were verified by the experimental results. The shock structure at the diagonal plane was in good agreement with the experimental schlieren images. Moreover, the cross-sections visualized by the Mie scattering method confirmed that the cross-section of the jet becomes cross-shape.

  • PDF

High Performance Liquid Chromatographic Analysis of a New Proton Pump Inhibitor KR60436 and Its Active Metabolite O-Demethyl-KR60436 in Rat Plasma Samples Using Column-Switching

  • Lee, Hyun-Mee;Lee, Hee-Yong;Choi, Joong-Kwon;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.24 no.3
    • /
    • pp.207-210
    • /
    • 2001
  • A fully automated high performance liquid chromatography with column-switching was developed for the simultaneous determination of KR60436, a new reversible proton pump inhibitor, and its active metabolite O-Demethyl-KR60436 from rat plasma samples. Plasma sample (50$\mu$l) was directly introduced onto a Capcell Pak MF Ph-1 column ($10{\times}4$ mm I.D.) where primary separation was occurred to remove proteins and concentrate target Substances Using acetonitrile-Potassium Phosphate (PH 7, 0.1 M) (2 : 8, v/v). The drug molecules eluted from MF Ph-1 column were focused in an intermediate column ($10{\times}2$ I.D.) by the valve switching step. The substances enriched in intermediate column were eluted and separated on a Vydac 218MR53 column ($250{\times}3.2$ I.D.) using acetonitrilepotassium phosphate (pH 7, 0.02 M) (47:53, v/v) at a flow rate of 0.5 ml/min when the valve status was switched back to A position. The method showed excellent sensitivity (detection limit of 2 ng/ml) with small volume of samples ($50{\mu}$l), good precision and accuracy, and speed (total analysis time 24 min) without any loss in chromatographic efficiency. The response was linear ($r^2{\geq}0.797$) over the concentration range of 5-500 ng/ml.

  • PDF

Determination of Ketorolac in Human Serum by High-performance Liquid Chromatography

  • Chun, In-Koo;Kang, Hyun-Hee;Gwak, Hye-Sun
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.529-534
    • /
    • 1996
  • A high-performance liquid chromatographic (HPLC) assay has been developed for the determination of ketorolac in human serum using a new extraction method with a good recovery. Human serum samples (1.0 ml) spiked with known concentrations of ketorolac tromethamine and 10${\mu}g$ of ketoprofen as the internal standard (IS) were acidified with 200${\mu}l$ of 1 N HCl and extracted with 7 ml of n-hexane-ether (7:3 v/v). Extracts were centrifuged and organic layer was back-extracted with 400${\mu}l$ of 0.1% tromethamine solution. Twenty .mu.l of centrifuged aqueous layer was injected onto a reversed-phase octyl column and eluted with a mixture of acetonitrile, water, methanol, and triethylamine [35:55:10:0.1 (v/v), pH 3.0] at a flow rate of 1.0 ml/min. Ultraviolet detection of ketorolac and IS was carried out at 300 nm. The calibration curve obtained using peak area ratios showed a good linearity (in concentration range 10-150 ng/ml $r^2$=O.9944; in range 50-2000 ng/ml, r$^{2}$=0.9998). The mean intra-day accuracy and precision for this HPLC method were found to be 3.6 and 3.7%, respectively. The mean inter-day accuracy and precision were found to be 4.0 and 3.7%, respectively, in the concentration range 50-2000 ng/ml. The recovery of ketorolac from serum was 92.0 $({\pm}5.7)$ % at the concentration of 100 ng/ml. This method proved to be readily applicable to the assay of ketorolac in human serum.

  • PDF

High Performance Liquid Chromatographic Assay of a New Fluoroquinolone, LB20304, in the Plasma of Rats and Dogs

  • Seo, Mi-Kyeong;Jeong, Yi-Na;Kim, Hoon-Joo;Kim, In-Chull;Lee, Yong-Hee
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.554-558
    • /
    • 1996
  • High-performance liquid chromatographic method was developed for the determination or LB 20304 (compound 1) in the plasma of rats and dogs. The analyte was deproteinized with 1 volume of methanol and 1/2 volume of 10% zinc sulfate, and the supernatant was injected onto a reversed-phase HPLC column. The mobile phase was a mixture of 24 parts of acetonitrile and 76 parts of 0.1% trifluoroacetic acid. The flow rate was 1 ml/min, and the effluent was monitored by fluorescence detector at an excitation wavelength of 337 nm and an emission wavelength of 460 nm. The retention time of compound 1 was 6.3 min. The assay of compound 1 was linear over the concentration range of 0.2-100.mu.g/ml in the plasma of rats and dogs. The lower limit of quantification was 0.2.mu.g/ml using 100.mu.l of plasma with a 97-99% accuracy and a 12-14% precision. In the 0.5, 5, and 50.mu.g/ml quality control samples, the intra- and inter-day accuracy were 88-95% and 88-97%, whereas intra- and interday precision were 0.5-6.6% and 0.2-9.3%, respectively, in the plasma of rats and dogs. The recoveries were 68-71% independent of concentration and species in the plasma. No interferences from endogenous substances were observed. Taken together, the above HPLC assay method by deproteinization and fluorescence detection was suitable for the determination of compound 1 in the preclinical pharmacokinetics.

  • PDF

Cellular Mechanism of Newly Synthesized Indoledione Derivative-induced Immunological Death of Tumor Cell

  • Oh, Su-Jin;Ryu, Chung-Kyu;Baek, So-Young;Lee, Hyun-Ah
    • IMMUNE NETWORK
    • /
    • v.11 no.6
    • /
    • pp.383-389
    • /
    • 2011
  • Background: EY-6 is one of the newly synthesized indoledione derivatives to induce tumor cell-specific cell death. In this study, we investigated the mechanism of immunological death induced by EY-6 at mouse colon cancer cell as well as at the normal immune cell represented by dendritic cell. Methods: C57BL/6 mouse syngeneic colon cancer cell MC38 was treated with EY-6, and analyzed by MTT for viability test, flow cytometry for confirming surface expressing molecules and ELISA for detection of cytokine secretion. Normal myeloid-dendritic cell (DC) was ex vivo cultured from bone marrow hematopoietic stem cells of C57BL/6 mice with GM-CSF and IL-4 to analyze the DC uptake of dead tumor cells and to observe the effect of EY-6 on the normal DC. Results: EY-6 killed the MC38 tumor cells in a dose dependent manner (25, 50 and $100{\mu}M$) with carleticulin induction. And EY-6 induced the secretion of IFN-${\gamma}$ but not of TNF-${\alpha}$ from the MC38 tumor cells. EY-6 did not kill the ex-vivo cultured DCs at the dose killing tumor cells and did slightly but not significantly induced the DC maturation. The OVA-specific cross-presentation ability of DC was not induced by chemical treatment (both MHC II and MHC I-restricted antigen presentation). Conclusion: Data indicate that the EY-6 induced tumor cell specific and immunological cell death by modulation of tumor cell phenotype and cytokine secretion favoring induction of specific immunity eliminating tumor cells.

An Experimental Study on the Dispersion Characteristics of Seawater Injection Nozzle for Hull Cooling (선체냉각을 위한 해수분사노즐의 산포특성에 관한 실험 연구)

  • Yoon, Seoktae;Jung, Hoseok;Cho, Yongjin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.767-773
    • /
    • 2017
  • Infrared stealth is an important technology for naval ships. This technology helps improve the anti-detection performance and survivability of naval ships. In general, the infrared signature of naval ships are categorized into internal and external heat source. External signature are generated by ship surface heating by solar flux as well as the complicated heat transfer process with the surrounding weather condition. Modern naval ships are equipped with seawater injection nozzles on the outside for nuclear, biological and, chemical, and these nozzles are used to control external signature. Wide nozzle placement intervals and insufficient injection pressure, however, have reduced seawater dispersion area. To address this problem, nozzle installation standards must be established. In this study, an actual-scale experimental system was implemented to provide the evidence for nozzle installation standards in order to reduce the infrared signature of naval ships. In addition, the environmental conditions of the experiment were set up through computational fluid dynamics considering the ocean climate data and naval ship management conditions of South Korea. The dispersion distance was measured using a high-resolution thermography system. The flow rate, pipe pressure, and dispersion distance were analyzed, and the evidence for the installation of seawater injection nozzles and operation performance standards was suggested.

Analysis of Related Compounds from Commercial Atenolol Raw Materials and Preparations by High-Performance Liquid Chromatography (HPLC를 이용한 시판 아테놀롤 원료 및 제품 중 유연물질의 분석)

  • Dong, Nguyen Thanh;Kang, Ji-Youn;Jung, Young-Hee;Lim, Eun-Hee;Hwang, Gwi-Seo;Kang, Chan-Soon;Kim, Eun-Jung;Kang, Jong-Seong
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.6
    • /
    • pp.453-457
    • /
    • 2004
  • Atenolol and related compounds found in raw materials and commercial products were analyzed by reversed-phase high-performance liquid chromatography. A mixed solution of phosphate buffer (3.4 g/l, pH 3.0), tetrahydrofurane and methanol (800:20:180, v/v/v) including sodium octanesulfonate (1 g/l) and tetrabutylammonium-hydrogensulfate (0.4 g/l) was used as mobile phase at the flow rate of 0.25 ml/min. Detection was carried out at UV 226 nm. Atenolol related compounds, such as bis ether, tertiary amine and blocker acid were identified by comparing the retention time of the standard. The within-day and between-day precisions of the separated compounds were less than 1.2% and 3.4%, respectively. The contents of related compounds of the tested samples were under the limit prescribed in the European Pharmacopoeia. The pattern of the related compounds showed that atenolol raw materials and products could be classified in three different groups, indicating that the materials originated from different source or treated in different way.

Design of Sample Chamber and Implementation of a 4-Channel Electrolyte Analyzer using ISFET Microsensor (ISFET 마이크로센서용 샘플챔버 설계 및 4채널 전해질 분석기의 구현)

  • Bae, Sang-Kon;Lee, Ho-Shin;Won, Chul-Ho;Chae, Seung-Pyo;Kim, Chang-Soo;Cho, Byung-Wook;Sohn, Byung-Ki;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.307-315
    • /
    • 1997
  • In this paper, a sample chamber which provide easy replacement of ISFET sensor and consume only small sample volume for electrolyte analysis is designed and a 4-channel electrolyte analyzer employing 2-point calibration method is implemented. In addition, we proposed sample loading detection circuit for minimizing sample and calibration solutions and implemented it. Developed electrolyte analyzer consists of control system part and flow system part. For the effective control of the developed hardware, system software is developed as three individual routines ; measuring routine, calibration routine and washing routine.

  • PDF

A Study on Distance Relay of Transmission UPFC Using Artificial Neural Network (신경회로망을 이용한 UPFC가 연계된 송전선로의 거리계전기에 관한 연구)

  • Lee, Jun-Kyong;Park, Jeong-Ho;Lee, Seung-Hyuk;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.37-44
    • /
    • 2004
  • This paper represents a new approach for the protective relay of power transmission lines using a Artificial Neural Network(ANN). A different fault m transmission lines need to be detected classified and located accurately and cleared as fast as possible. However, The protection range of the distance relay is always designed on the basis of fixed settings, and unfortunately these approach do not have the ability to adapt dynamically to the system operating condition. ANN is suitable for the adaptive relaying and the detection of complex faults. The backpropagation algerian based multi-layer protection is utilized for the teaming process. It allows to make control to various protection functions. As expected, the simulation result demonstrate that this approach is useful and satisfactory.

A Study of Internet Address Collision Detection Method (인터넷 주소 충돌 감지에 관한 연구)

  • 위선정;임영희;이태헌;박기홍
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.545-547
    • /
    • 2004
  • Currently possibility of the change of seal computer it increases geometrical progression and the general individuals the knowledge which is special regarding the ip are using the flow child blood which it Provides without from the isp enterprise. But most of the case peon of the school which uses the fixation child blood or the company because is not the knowledge against a TCP/IP address is not oneself at deliberation or real income and it will use the TCP/IP address of the different user and the network whole it will paralyze, the original user will not be able to use the network and it makes. With information where address information where the network administrator present time after data base anger one uses address information of the civil official objective personal computers and network systems of the watch inside in the dictionary is stored will be same from the dissertation which it sees hereupon and the web which it will yell it leads and packet it detects, the use of the TCP/IP address which goes wrong in the user and it notifies the method which is the possibility of closing the paralysis of the network system which it follows in the IP address fringe land due to a deliberation or a real income to sleep it presents it does.

  • PDF