• 제목/요약/키워드: Flotation process

검색결과 191건 처리시간 0.024초

Feasibility Studies on Anaerobic Sequencing Batch Reactor for Sludge Treatment

  • Chang Duk;Hur Joon-Moo;Son Bu-Soon;Park Jong-An;Jang Bong-Ki
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제1권2호
    • /
    • pp.125-136
    • /
    • 1997
  • Digestion of a municipal wastewater sludge by the anaerobic sequencing batch reactor(ASBR) was investigated to evaluate the performance of the ASBR process at a critical condition of high-solids-content feed. The reactors were operated at an HRT of 10 days with an equivalent loading rate of 0.8-1.5 gVS/L/d at $35^{\circ}C.$ The main conclusions drawn from this study were as follows: 1. Digestion of a municipal wastewater sludge was possible using the ASBR in spite of high concentration of settleable solids in the sludge. The ASBRS with 3- and 4-day cycle period showed almost identical high digestion performances. 2. No adverse effect on digestion stability was observed in the ASBRS in spite of withdrawal and replenishment of $30\%\;or\;40\%$ of liquid contents. A conventional anaerobic digester could be easily converted to the ASBR without any stability problem. 3. Flotation thickening occurred in thicken step of the ASBRS throughout steady state, and floating bed volume at the end of thicken period occupied about $70\%$ of the working volume of the reactor. Efficiency of flotation thickening in the ASBRS could be comparable to that of additional gravity thickening of a completely mixed digester. 4. Solids were accumulated rapidly in the ASBR during start-up period. Solids concentrations in the ASBRS were 2.6 times higher than that in the completely mixed control reactor at steady state. Dehydrogenase activity had a strong correlation with the solids concentration. Dehydrogenase activity of the digested sludge in the ASBR was 2.9 times higher than that of the sludge in the control reactor, and about 25 times higher than that of the subnatant in the ASBR. 5. Remarkable increase in equivalent gas production of $52\%$ was observed at the ASBRS compared with the control reactor in spite of similar Quality of clarified effluent from the ASBRS and control reactor. The increase in gas production from the ASBRS was believed to be combined results of accumulation of microorganisms, higher driving force applied, and additional long-term degradation of organics continuously accumulated.

  • PDF

석탄화력발전소에서 발생되는 비회로부터 유용성분의 회수 (Recycling of useful Materials from Fly Ash of Coal-fired Power Plant)

  • 김둘선;한광수;이동근
    • 청정기술
    • /
    • 제25권3호
    • /
    • pp.179-188
    • /
    • 2019
  • 석탄화력 발전시 석탄은 석탄회로 발생하게 되는데 비회(fly ash)가 80%, 저회(bottom ash)가 20% 비율로 발생된다. 그러나 이들 대부분은 재활용되지 못하고 매립장에 전량 폐기되고 있고, 비회 및 저희를 매립하는 매립장이 포화될 경우 새로운 대체 매립장을 건설하지 못하는 한 석탄화력발전소의 운영을 중지해야 하는 경우가 발생할 수 있다. 본 연구에서는 비회를 재활용하여 자원화하기 위해 습식 부유선별기술(부선과정)을 이용하여 비회 내 유용성분{미연탄소(unburned carbon, UC), 뮬라이트(ceramic microsphere, CM), 실리카(cleaned ash, CA)}을 회수하였으며, 회수된 유용성분들의 특성분석으로 산업 소재로 재활용 가능성을 조사하였다. 비회로부터 회수된 유용성분의 회수율은 UC 92.10%, CM 75.75%, CA 69.71%로 부선과정을 통하여 UC가 다른 성분보다 회수율이 16 ~ 22% 더 우수한 것으로 나타났다. UC의 연소가능성분(combustible component, CC)은 52.54wt%, 발열량도 $4,232kcal\;kg^{-1}$로 높아서 석탄 기준 C의 함량 100%일 경우 $8,100kcal\;kg^{-1}$로 감안할 때 산업용 연료로 사용이 가능할 것으로 사료된다. CM과 CA의 분리는 pH의 영향으로 UC 보다는 화학적 분리가 효과적이었으며, 회수된 CA의 $SiO_2$ 함량은 78.66wt%, CM의 $SiO_2$ 함량은 53.55wt%로 나타나 산업용 소재로 재활용 가능성을 확인할 수 있었다.

도심지역 내 중·소하천 수질 개선을 위한 가압부상 및 관로형 미생물 부착 공정 적용에 관한 연구 (Improvement of Medium and Small Urban Stream Water Quality and Applicability of Design Factor Using Biological and Physicochemical Processing)

  • 김문기;최정수;김삼주;김현구
    • 대한환경공학회지
    • /
    • 제35권7호
    • /
    • pp.509-517
    • /
    • 2013
  • 본 연구의 목적은 도심지역 중소하천의 효율적인 수질정화를 위해 물리화학적, 생물학적 처리공정을 결합한 장치형 하천수질정화공법의 적용성을 평가하는데 있다. 본 연구의 하천정화시설은 TSS 및 TP 제거를 위한 가압부상(Micro Bubble Process, MBP)공정과, BOD 제거를 위한 관로형 미생물 부착(Attached Microbial Pipe System, AMPS)공정으로 구성하였다. 각 장치의 실험 조건은 MBP 공정의 부상조 체류시간 및 초미세기포 주입량 변화와 AMPS 공정의 체류시간의 변화를 설정하였다. 또한 계절 변화에 따른 각 공정의 오염원 제거효율을 평가하였다. 각 공정의 연속운전 결과 MBP 공정에서는 최대 TSS 83.69%, TP 95.15%의 처리효율을 나타냈으며, AMPS 공정의 TBOD5 제거효율은 최대 53.0%를 나타냈다. 또한 각 공정의 순환운전 결과 MBP 공정에 의해 최대 TSS 69.75%, TP 70.17%의 처리효율을 나타냈으며, AMPS 공정에 의해 TBOD5 제거효율은 최대 68.58%를 나타냈다. 따라서 본 하천정화시설은 도심지역 내 오염된 하천의 수질을 개선하는데 효과적이라고 사료된다.

방습 효과가 우수한 환경친화적 방습지(제1보) -방습제의 특성- (Environmentally Friendly Moisture-proof Paper with Superior Moisture Proof Property (I) -Properties of Moisture Proof Chemicals-)

  • 유재국;조욱기;이명구
    • 펄프종이기술
    • /
    • 제33권4호
    • /
    • pp.15-20
    • /
    • 2001
  • The function of the moisture-proof paper is to prevent moisture from adsorbing into the packed goods. Water-vapor transmission rate of the moisture-proof paper should be less than 100g/$m^2$.24hr and the optimum rate would be less than 50g/$m^2$.24hr. In general the moisture-proof paper has been made by laminating polyethylene or polypropylene on top of the base paper. However this kind of moisture-proof paper has a problem in recycling so that it brings about environmental pollution. In general the moisture-proof paper has been made by laminating polyethylene or polypropylene on top of the base paper. However this kind of moisture-proof paper has a problem in recycling so that it brings about environmental pollution. The purpose of this paper was to make moisture-proof paper using the mixture of SB latex and wax emulsion which was recyclable and environmentally friendly. Water vapor transmission rate showed less than 50g/$m^2$.24hr in mixture ratio of 85:15, 87:13, 90:10. Especially the mixture ratio of 87:13 showed the most favorable water-vapor transmission rate. However, the moisture-proof layer was destroyed slightly by folding in packing. It has been observed that there was no close relationship between water-vapor transmission rate of the moisture-proof paper and grammage of the base paper, but the density of base paper had influenced on water vapor transmission rate. It was also observed that the moisture-proof paper could be recycled. The moisture-proof paper was similar to base paper in degree of the pulping, and there was no significant difference in dispersion between moisture-proof paper and base paper. Most of wax particles which caused the spots during drying process could be removed by flotation process. Tensile strength and tear strength of both moisture-proof paper and base paper after pulping were measured to examine the fiber bonding, and no significant difference in physical properties was observed.

  • PDF

회동수원지의 정수처리 공정을 위한 DAF pilot plant 운영 성능평가 (Operation evaluation of DAF pilot plant for water treatment process in Hoedong Reservoir)

  • 맹민수;;김동현;신귀암;독고석
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.463-471
    • /
    • 2020
  • A 1,000 ㎥/d DAF(dissolved air flotation) pilot plant was installed to evaluate the performance of the floating process using the Nakdong River. Efficiency of various DAF operations under different conditions, such as hydraulic loading rate, coagulant concentration was evaluated in the current research. The operation conditions were evaluated, based on the removal or turbidity, TOC(total organic carbon), THMFP(trihalomethane formation potential), Mn(manganese), and Al(aluminum). Also, particle size analysis of treated water by DAF was performed to examine the characteristics of particles existing in the treated water. The turbidity removal was higher than 90%, and it could be operated at 0.5 NTU or less, which is suitable for the drinking water quality standard. Turbidity, TOC, and THMFP resulted in stable water quality when replacing the coagulant from alum to PAC(poly aluminum chloride). A 100% removal of Chl-a was recorded during the summer period of the DAF operations. Mn removal was not as effective as where the removal did not satisfy the water quality standards for the majority of the operation period. Hydraulic loading of 10 m/h, and coagulant concentrations of 40 mg/L was determined to be the optimal operating conditions for turbidity and TOC removal. When the coagulant concentration increases, the Al concentration of the DAF treated water also increases, so coagulant injection control is required according to the raw water quality. Particle size distribution results indicated that particles larger than 25 ㎛ showed higher removal rates than smaller particles. The total particel count in the treated water was 2,214.7 counts/ml under the operation conditions of 10 m/h of hydraulic loading rate and coagulant concentrations of 60 mg/L.

단위공정별 기초실험을 통한 다기능 융복합부도의 설계·운전인자 도출 (Design and operating parameters of multi-functional floating island determined by basic experiments of unit processes)

  • 임현만;장여주;정진홍;윤영한;박재로;김원재
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.487-497
    • /
    • 2018
  • Water quality improvement processes for stagnant area consist mainly of technologies applying vegetation and artificial water circulation, and these existing technologies have some limits to handle pollution loads effectively. To improve the purification efficiency, eco-friendly technologies should be developed that can reinforce self-purification functions. In this study, a multi-functional floating island combined with physical chemical biological functions ((1) flotation and oxidization using microbubbles, (2) vegetation purification and (3) bio-filtration with improved adsorption capacity) has been developed and basic experiments were performed to determine the optimal combination conditions for each unit process. It has been shown that it is desirable to operate the microbubble unit process under conditions greater than $3.5kgf/cm^2$. In vegetation purification unit process, Yellow Iris (Iris pseudacorus) was suggested to be suitable considering water quality, landscape improvement and maintenance. When granular red-mud was applied to the bio-filtration unit process, it was found that T-P removal efficiency was good and its value was also stable for various linear velocity conditions. The appropriate thickness of filter media was suggested between 30 and 45 cm. In this study, the optimal design and operating parameters of the multi-functional floating island have been presented based on the results of the basic experiments of each unit process.

석탄재에 포함된 희토류 회수 연구동향 (Current Research Trends for Recovery of Rare Earth Elements Contained in Coal Ash)

  • 김영진;최문관;서준형;김병렬;조계홍
    • 자원리싸이클링
    • /
    • 제29권6호
    • /
    • pp.3-14
    • /
    • 2020
  • 석탄재로부터 희토류 회수에 관한 연구 자료를 분석 및 검토하였다. 석탄재로부터 희토류 회수를 위해 적용된 선별 실험은 주로 PC 보일러로부터 발생된 석탄재를 대상으로 입도분리, 자력, 비중 및 부유선별법 등을 이용해 연구하였다. 선별 공정을 통해 희토류 성분의 농축 가능한 수준은 수 천 ppm 정도로 낮게 확인되었고, 선별 공정 이후 회수된 산물을 대상으로 습식 제련 공정을 통한 추가 농축 처리가 필요한 것으로 확인되었다. 침출 공정에서는 석탄재의 희토류 성분을 침출 향상을 위해 알칼리 용융과 같은 전처리 후, 침출공정에 적용하는 것이 효율적인 공정으로 확인되었다. 세계적 희토류 회수 시스템의 개발이 아직은 미흡한 것으로 확인되었으나, 석탄재에 포함된 희토류 회수 연구는 계속 진행될 것으로 보고되었다. 국내에서는 석탄재 중 희토류 회수를 위한 회수 기술이 매우 부족한 상황으로 선별, 침출 등의 기술 개발이 시급한 실정이다.

슬러리 양돈분뇨의 최적 고액분리 방안 연구 (A Practical Study on the Solid-Liquid Separation of the Swine Wastewater from Slurry Feedlot)

  • 박성균;최재길;정윤진
    • 유기물자원화
    • /
    • 제8권2호
    • /
    • pp.60-70
    • /
    • 2000
  • 현재 국내에서 처리에 어려움을 겪고 있으며 사회적으로 문제가 되고 있는 양돈 분뇨의 처리중 생물학적 처리를 위한 전처리 공정의 일환으로 비육돈 슬러리 돈사에서 발생하는 분뇨를 대상으로 고액분리에 관한 연구를 수행하였다. 최적의 고액 분리를 위하여 적정 응집제 선정 및 첨가량을 도출하였으며, 현장 규모의 고액 분리 장치를 통하여 규모별 최적 고액 분리 공정을 도출하였다. 이 결과 탈수성 개량을 위한 적정 응집제로는 Polyarcylamide 계열의 양이온 고분자 응집제인 E-851이 적합하였으며, 단위 고형물당 0.24~0.6%가 요구되었다. 본 연구에서 검토된 공정으로는 Mesh Screen, Drum Screen, Cyclone Drum Filter, Screw Press, 고속 Screw Decanter, 저속 Screw Decanter 및 DAF 공정을 조합하여 검토하였다. 그 결과 최적 공정으로는 중 소규모의 1차 고액 분리 공정으로는 Screw Press(응집제 첨가)와 대규모 및 공공처리장 규모에서는 저속 Screw Decanter(응집제 첨가)가 적정 공정으로 도출되었으며 2차 처리 공정으로는 가압부상조가 가장 안정적인 것으로 나타났다. 한편 고액 분리 유무에 따라 수분조절제 및 유기물 부하량 감소는 각각 94.8, 84.7%로 나타났으며 슬러리 양돈분뇨의 정화방안으로는 고액분리가 반드시 필요한 것으로 나타났다.

  • PDF

파일롯 규모의 토양세척장치 개발 (Development of a Pilot-Scale Soil Washing Process)

  • 장윤영;신정엽;황경엽
    • 한국토양환경학회지
    • /
    • 제3권3호
    • /
    • pp.55-62
    • /
    • 1998
  • 탄화수소계 화합물이나 중금속 잔류물 등으로 오염된 토양은 토양세척방법에 의해 효과적 으로 처리할 수 있다. 본 연구에서 토양세척공정을 개발하는데 있어 토양으로부터 오염물을 분리하기 위한 몇 가지 주요 핵심 공정기술들은 채광기술과 화학공정기술의 접목을 통하여 점차적으로 개선되어 얻어졌다. 본 파일롯 규모의 토양세척장치는 공정 상 크게 네 부분으로 이루어져 있다. 1) 기계적 마찰, 2) 세척수를 이용한 세탁작용, 3) 최종세정, 4) 오염된 세척수의 재생. 장치는 현장에서 오염토양을 시간당 5톤 속도로 처리하기 위한 규모로 설계하였다. 오염된 토양 덩어리는 먼저 1차 세척부인 회전 마찰 분쇄 관을 통과하면서 개개의 토양입자로 부셔지고 다음, 교반날이 설치된 2차 세척부에서 세척수와의 강한 마찰효과에 의해 오염물의 탈착이 이루어지게 된다. 최종 단계인 3차 세척부에선 세척된 토양을 최종적으로 물분사장치를 이용하여 세정하고 오염된 세척수와 정화된 토양을 역방향으로 분리하여 각각 배출시킨다. 세척수를 연속적으로 재사용하기 위하여 오염된 세척수는 미세토의 응집, 침전과 기름성분의 부상분리가 이루어지는 세척수 처리조를 거쳐 세척부로 다시 반송되도록 하였다. 추후 이동과 운전비용을 줄이면서 현장에 적합한 토양세척장치의 적용성을 얻기 위하여 트레일러에 탑재된 이동형 토양세척장치개발에 대한 연구를 진행할 것이다.

  • PDF

TPH와 6가 크롬으로 오염된 지하수 처리를 위한 실내 실험 (Treatability Study on the Remediation Groundwater Contaminated by TPH Cr6+ : Lab-Scale Experiment)

  • 이규범;장윤영
    • 환경영향평가
    • /
    • 제28권3호
    • /
    • pp.332-345
    • /
    • 2019
  • 이 연구의 목적은 TPH 또는 $Cr^{6+}$이 함유된 오염 지하수의 처리 가능성을 평가하는 데 있다. 오일과 물의 분리, 용존 공기 부유 (DAF), 응고 및 침전, 모래와 활성탄으로 각각 여과를 위한 실험실 규모 테스트가 수행되었다. 총 40 분간의 분리 시간 동안 오일과 물의 분리 시험을 2 회 실시한 결과 TPH 제거율은 90.2 %였다. 높은 농도의 TPH 샘플에 대한 DAF 테스트의 경우, TPH 제거율은 미세 기포 크기의 변화에 따라 크게 변하지 않았다. 그러나 낮은 TPH 샘플에 대한 테스트는 미세 기포가 작을수록 TPH 제거율이 증가함을 보여준다. DAF 테스트를 위해 응집제를 샘플에 첨가했을 때 TPH 제거율은 12.3 % 증가했다. DAF에 의한 SS 제거율은 $16{\sim}40{\mu}m$에서 97.9 %였으며 미세 기포의 크기가 감소함에 따라 증가했다. 지하수에서 $Cr^{6+}$의 제거를 평가하기 위해 응집 및 침전 시험을 수행했다. $FeSO_4$ 투여량을 증가하였을때 응집 및 침전 공정에서 $Cr^{6+}$ 제거율이 증가하였다. 필터 매체에서 활성탄의 비율이 높을수록 여과공정에서 TPH 제거율이 증가한다. 여과에 의한 SS 제거율은 DAF 공정 시험 결과와 비슷한 96.7 %였다. 여과 과정은 TPH와 SS 농도가 감소하였다. 모래의 크기가 $425{\sim}850{\mu}m$이고 활성탄과 모래의 비율이 50:50일때 최적의 처리효율을 나타냈다.