• 제목/요약/키워드: Floor temperature

검색결과 471건 처리시간 0.023초

급기가 되는 이중바닥 구조체의 열 성능 평가 (Estimation of the thermal performance on the double slab floor with supplying air)

  • 차광석;박명식;이대우;남우동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

모세유관 바닥복사 냉·난방 시스템의 성능평가 (Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System)

  • 서유진;김태연;이승복
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.

온돌 온열환경지표 평가방법 (Evaluation Methods on ONDOL Thermal Environmental Index)

  • 김성조
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.101-110
    • /
    • 2022
  • For this purpose, the authors proposed and proved usefulness of the modified mean skin temperature which is integrated mean radiation temperature and the effect of floor contacted heat conduction. The mean radiation temperature is applied form factor between half cross-legged human body and surrounding wall of indoor. In addition the floor contacted heat conduction is applied heat transfer coefficient of half cross-legged human body. Eight Korean young men were targeted for the experiment. From the experiment the authors excerpted physiological reaction and psychological reaction in Ondol environment which is combined physiccal environmental factor of artificial climate chamber, air and floor temperature. As a result of the experiment it is confirmed that heat conduction has more impact than heat exchange from existing research for the heat exchange between half cross-legged human body and surrounding wall in Ondol thermal environment. Thereby, it is proved the effectiveness of the modified mean skin temperature which is added floor contacted temperature to the Ondol thermal environmental evaluation index.

온돌의 구들장과 땅바닥의 비정상 열전도 해석 (Transient Heat Conduction Through the Ondol Floor and Beat toss to the Ground)

  • 배순훈;김두천
    • 대한설비공학회지:설비저널
    • /
    • 제4권1호
    • /
    • pp.6-17
    • /
    • 1975
  • For a periodic variation of the flue gas temperature the heat conduction through the Ondol floor was analysized. Also the heat loss to the ground was estimated. The floor thermal capacity, as a function of the floor thickness, has strong influence on the time lag of the temperature variation. It is an important design parameter for intermittent heating. Even for the steady periodic variation, there was significant heat loss to the ground below the Ondol floor.

  • PDF

MDF로 제조된 우드세라믹의 표면온도변화(I) -밀도 및 소성온도의 영향- (Change of Surface Temperature in Woodceramics Made from MDF(I) -Effect of Density and Burning Temperature-)

  • 오승원
    • 임산에너지
    • /
    • 제21권1호
    • /
    • pp.1-6
    • /
    • 2002
  • 본 연구는 MDF로 제조된 우드세라믹을 이용하여 온돌마루판 시공 시 하부소재로서의 사용가능성을 검토하고자 실시하였다. 650℃와 800℃로 소성하여 제조된 우드세라믹을 발열판 위에 올려놓고 발열판의 온도 및 시간의 경과에 따른 우드세라믹의 표면온도의 변화를 측정하였다. 우드세라믹의 표면온도는 밀도가 증가함에 따라 표면온도가 증가하였으며, 바닥온도의 변화에 따른 표면온도는 바닥온도가 증가함에 따라 표면온도가 증가하여, 측정온도가 높을수록 열전도가 빠름을 알 수 있었다. 그러나 우드세라믹 제조 시 소성온도에 따른 표면온도의 변화는 뚜렷한 차이를 발견할 수 없었다.

  • PDF

온돌면(溫突面)의 방열량(放熱量) 산정방법(算定方法)에 관한 연구(硏究) (A Calculation Method on Heat Flux from Ondol Floor Surface)

  • 손장열;안병욱;방승기
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.173-181
    • /
    • 1989
  • Until recently there was a lack of reliable performance data for the design and operation of Ondol heating systems. This paper presents a calculation method on heat flux from Ondol floor surface. Total heat flux from floor consists of radiation and convection component. In order to analyse the characteristics of both radiation and convection heat flux, each surface temperature is measured and several temperatures near each wall are measured vertically and horizontally in a practical Ondol heating space. Radiation heat flux is calculated and analysed by Gebhart's Absorption Factor Method with the consideration of instantaneous radiant exchanges. Convection heat output is derived from the vertical temperature profiles near floor. The vertical temperature profiles could be expressed by nonlinear regression equation models and convection coefficients could be estimated by the equations. As a result, radiation, convection and total heat flux are suggested by the expression of difference between floor surface and room air temperature.

  • PDF

열전도를 고려한 각 자세에 따른 평균 피부온의 산출 (NEW WEIGHTING COEFFICIENTS FOR CALCULATING MEAN SKIN TEMPERATURE IN RELATION TO THE POSTURE WITH CONSIDERATION TO HEAT CONDUCTION)

  • 이주연;미야모토 세에치;이소다노리오
    • 대한인간공학회지
    • /
    • 제19권2호
    • /
    • pp.63-74
    • /
    • 2000
  • This paper is to clarify a thermal physiological index that can account for the effects of local thermal environment. For this purpose two young female subjects exposing themselves to the above while sitting on a chair, sitting on the floor and lying on the floor were measured. These three representative postures accompanied the different contact surface areas, thereby the heat conduction rate between the floor and subject was quantitatively measured for each posture. It made the present study deal with the effect of heat conduction concerning the modified mean skin temperature and finally propose new weighting coefficients for the mean skin temperature calculation based on the Hardy & DuBois' formulas. In order to verify the proposed model, the experiment was carried out using a floor heating system. The comparison between the experimental result and prediction revealed that the proposed model should be about 10% more accurate than the conventional one in the case of lying on the floor which the heat conduction effect becomes important.

  • PDF

발전소 터빈건물의 창문 위치에 따른 온도저감 (Temperature Reduction with the Location of Window in a Turbine Building of Power Plant)

  • 하지수;김태권;정경호
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.207-213
    • /
    • 2016
  • 본 연구에서는 화력발전소 터빈 건물의 온도저감 방안을 도출하기 위해 전산유체역학 상용코드인 ANSYS-FLUENT를 이용하여 열유동 해석을 수행하였다. 터빈 건물의 운전층(operating floor)과 탈기기층(deaerator floor)을 검사체적으로 선정하여 모델링을 하였으며 탈기기층에 설치된 기존의 채광창을 활용하여 환기창으로 대체하는 경우에 대해 해석을 수행하였다. 본 연구를 통하여 첫째, 운전층의 온도를 저감하기 위한 방안은 탈기기층의 모든 창문을 열지 않아야 됨을 알았다. 둘째, 탈기기층의 온도를 저감하기 위한 방안으로 탈기기층의 전면부의 창문을 개방하면 탈기기 영역과 크레인 영역은 각각 $1.5^{\circ}C$$1.6^{\circ}C$를 저감할 수 있었고, 탈기기 후면부의 창문을 개방하면 탈기기 영역은 $1.4^{\circ}C$, 크레인 영역은 $0.5^{\circ}C$의 온도를 저감할 수 있었다. 따라서 고온의 탈기기층 전체 영역의 온도를 저감하기 위해서는 탈기기층 전면부의 창문을 개방하는 것이 유리할 것으로 판단된다.

주거 건물의 복사냉방시스템 적용에 관한 연구 (A Study on the Application of the Radiant Floor Cooling System in Residential Building)

  • 임재한;여명석;김광우
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.73-82
    • /
    • 2004
  • The objective of this study is to demonstrate the potential of radiant cooling systems using Ondol as an alternative cooling system in residential buildings. For this purpose, computer simulation and model experiments have been performed for the system performance analysis regarding comfort, floor surface condensation, and supply water temperature. The results of this study is the following: In radiant floor cooling system, room air temperatures were maintained within the set temperature range of $\pm$1$^{\circ}C$ without any discomfort condition. And taking into account only the condensation occurrence, it was possible to achieve radiant floor cooling for a period of about 77% of the total cooling period in weather condition of Seoul. The minimum supply water temperature is about 15$^{\circ}C$, so renewable energy system such as ground heat exchange system can be used as an alternative in cooling source. Also, floor surface condensation can be prevented by integrating with the dehumidification system.

옥상 저류조 설치에 따른 최상층 실내열환경 변화에 관한 모형 실험연구 (The Variation of Top Floor Indoor Thermal Environment with Roof Storage Using Model Experiment)

  • 박봉길;이경희;장승재
    • 한국주거학회논문집
    • /
    • 제20권3호
    • /
    • pp.105-112
    • /
    • 2009
  • The purpose of this study is to investigate a top floor, indoor, thermal environment by comparison between the indoor air temperature and the rooftop surface temperature, and between the indoor air temperature and the outdoor air temperature using an experimental model. The model experiment was conducted with 4 cases,: no-rainfall, 1 em-height, 10 em-height and 20em-height of rainfall on the rooftop. According to the results of the height of stored rainfall, the average air temperature difference between the indoor and outdoor air with 1, 10 and 20 em-height of rainfall on the rooftop was $4.0^{\circ}C$, rooftop $1.2^{\circ}C$ and rooftop $1.0^{\circ}C$, respectively. The upper 10 em-height of rainfall on the rooftop acted to decrease the indoor air temperature on the top floor.