• Title/Summary/Keyword: Floor materials

Search Result 710, Processing Time 0.029 seconds

Influences of Forest Fire on Forest Floor and Litterfall in Bhoramdeo Wildlife Sanctuary (C.G.), India

  • Jhariya, Manoj Kumar
    • Journal of Forest and Environmental Science
    • /
    • v.33 no.4
    • /
    • pp.330-341
    • /
    • 2017
  • Tropical forests play a key role for functioning of the planet and maintenance of life. These forests support more than half of the world's species, serve as regulators of global and regional climate, act as carbon sinks and provide valuable ecosystem services. Forest floor biomass and litterfall dynamics was measured in different sites influenced by fire in a seasonally dry tropical forest of Bhoramdeo wildlife sanctuary of Chhattisgarh, India. The forest floor biomass was collected randomly placed quadrats while the litterfall measured by placing stone-block lined denuded quadrat technique. The seasonal mean total forest floor biomass across the fire regimes varied from $2.00-3.65t\;ha^{-1}$. The total litterfall of the study sites varied from $4.75-7.56t\;ha^{-1}\;yr^{-1}$. Annual turnover of litter varied from 70-74% and the turnover time between 1.35-1.43 years. Monthly pattern of forest floor biomass indicated that partially decayed litter, wood litter and total forest floor were differed significantly. The seasonal variation showed that leaf fall differed significantly in winter season only among the fire regimes while the wood litter was found non significant in all the season. This study shows that significant variation among the site due to the forest fire. Decomposition is one of the ecological processes critical to the functioning of forest ecosystems. The decomposing wood serves as a saving account of nutrients and organic materials in the forest floor. Across the site, high fire zone was facing much of the deleterious effects on forest floor biomass and litter production. Control on such type of wildfire and anthropogenic ignition could allow the natural recovery processes to enhance biological diversity. Chronic disturbances do not provide time for ecosystem recovery; it needs to be reduced for ecosystem health and maintaining of the high floral and faunal biodiversity.

The Efficacy of the Graft Materials after Sinus Elevation: Retrospective Comparative Study Using Panoramic Radiography

  • Jeong, Tae Min;Lee, Jeong Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.4
    • /
    • pp.146-153
    • /
    • 2014
  • Purpose: This study compares and evaluates the efficacy of graft materials after maxillary sinus bone grafts with autogenous tooth bone graft material (AutoBT), demineralized freeze-dried bone allograft (DFDBA) and deproteinized bovine bone mineral (DBBM). Methods: The study involved 30 sinuses in 26 patients who visited the Division of Oral and Maxillofacial Surgery, Department of Dentistry in Ajou University Hospital and received either AutoBT, DFDBA or DBBM with sinus elevation using the lateral window technique. Sinus graft height was measured before, immediately after, and six months after bone graft with panoramic radiography and the height changes of the sinus floor was compared according to the graft materials. Results: After six months, the decrease ratio of graft heights were 13.57% for AutoBT group, 14.30% for DFDBA group, and 11.92% for DBBM group. There was no statistically significant difference. Conclusion: The new maxillary sinus floor formed by the upper border of bone graft material, can repneumatize after the maxillary sinus elevation. Thus, long-term stability of sinus graft height represents an important factor for implant success. We found that the three graft materials for sinus elevation do not differ significantly and all three graft materials showed excellent resistance to maxillary sinus repneumatization. However, due to the special circumstances of the maxillary sinus and small sample, the actual difference between the three graft materials may not have been detectable. Therefore further study needs to be conducted for more reliable study results.

A Study on the Floor Impact Sound Insulation Characteristics of Floor Coverings (바닥마감재에 의한 바닥충격음 차음특성 연구)

  • Gi, No-Gab;Kwon, Hyun-Jong;Song, Min-Jeong;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.682-686
    • /
    • 2002
  • It is increasing the interest on the comfortable dwelling environment, while sound Insulation performance of materials and elements used in building is falling down as they become thicker and lighter. Therefore, sound insulation performance in building has become the most important factor determining the level of housing, especially for apartment that has common wall and floor with next neighbors. This paper aims to experiment the sound insulation characteristics of floor coverings as their types and to analyse their noise reduction effect.

  • PDF

Evaluation of heavy-weight impact sounds generated by impact ball through classification (주파수 특성 분류를 통한 임팩트 볼 중량충격음의 주관적 평가)

  • Kim, Jae-Ho;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1142-1146
    • /
    • 2007
  • In this studies, subjective evaluation of heavy-weight floor impact sound through classification was conducted. Heavyweight impact sounds generated by an impact ball were recorded through dummy heads in apartment buildings. The recordings were classified according to the frequency characteristics of the floor impact sounds which are influenced by the floor structure with different boundary conditions and composite materials. The characteristics of the floor impact noise were investigated by paired comparison tests and semantic differential tests. Sound sources for auditory experiment were selected based on the actual noise levels with perceptual level differences. The results showed that roughness and fluctuation strength as well as loudness of the heavy-weight impact noise had a major effect on annoyance.

  • PDF

Evaluation of Floor Vibration Existing in Apartment Building (RC 아파트 바닥의 수직진동 성능 평가)

  • 이민정;한상환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.967-972
    • /
    • 2003
  • In recent years building floors has become larger and more spacious due to the development of new design methods and high strength and light weight materials. However, such long span floor systems may provide smaller amount of damping and have longer period so that they would be more vulnerable to the floor vibration. This study attempts to evaluate the performance of the floors in typical apartment buildings. Four different floors with the area of 43.2$m^2$, 41.44$m^2$, 34.5$m^2$, and 28.89$m^2$ were investigated. The guideline provided by AISC(997) and human perception level of Korean people proposed by S. W. Han(2003) are used to check the acceptability of the floor vibration.

  • PDF

A Effects of applying the noise reduction method between existing buildings (기존 건축물 층간소음 저감공법 적용 효과 분석)

  • Song, Tae-Hyeob;Jeon, Chan-Soo;Kim, Ji-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.249-250
    • /
    • 2018
  • To control the floor noise generated in the apartment building, a method of reinforcing the floor at the floor is applied. However, since existing buildings are difficult to reinforce upper generations, the ceilings of lower generations should be reinforced. The purpose of this study is to analyze the reduction effect by measuring the impact noise after reinforcing the floor soundproofing material on the ceiling of the existing building. In order to ensure the economical efficiency and flame retardancy of the products used as building interior materials, the existing polyurethane foam was impregnated with mineral to prepare test specimens and attached to the concrete slab surface. As a result, it was shown that heavy impact sound can reduce 2dB~5dB and light impact sound can reduce 4~8dB.

  • PDF

A Study on the Reduction Characteristics of Floor Impact Sound Insulation Due to the Ceiling Frame Structures in Apartment Houses (공동주택의 천장틀구조 변화에 따른 바닥충격음 차음특성 연구)

  • 정환욱;기노갑;송민정;김선우
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.8
    • /
    • pp.573-580
    • /
    • 2002
  • Generally the ceiling frame of apartment house is made of wood. But the wood frame has several problems due to the natural properties such as distortion by shrink, low fire resistance and material loss in the construction field. And it has some defections in sound insulation performance. Therefore it is necessary to develop a new method that can be used as a ceiling frame. This study aims to analyze and to compare the sound insulation characteristics against the floor impact sound between wood ceiling frame and M-bar frame which is made of steel. The results of this study are like these. M-bar frame is more effective than wood ceiling frame in sound insulation. And sound absorbing or sound insulation materials which can be Put on gypsum board are helpful to improve floor impact sound insulation performance.

A Study on the Perception of a Kleingarten House (체재형 가족농원의 주거시설에 대한 의식)

  • Park, Sun-Hee
    • Journal of the Korean housing association
    • /
    • v.22 no.3
    • /
    • pp.83-91
    • /
    • 2011
  • The aim of this study was to determine the basic perception of Kleingarten house planning of Jeonbuk area. The survey method was used for data collection. The major finding were as follows: 1) Almost all respondents have a very positive attitude the participant of Kleingarten. Many respondents wanted the cheapest price for the Kleingarten rental fee and for the travel time between their home and Kleingarten to be under an hour. 2) Two different size of 45 and 66 $m^2$ were preferable for the house floor plans. The most preferable floor plan type chosen by the respondents was a house design with a terrace and the elderly householders especially preferred a house floor plan with an LDK design. 54.3 per cent respondents liked the log house and 93.3 per cent respondents liked the eco-friendly building materials such as wood, earth (Korean natural earth: whangto), and adobe bricks etc. 3) There were more needs for useful facilities such as a pergola, a grassy lawn, small ponds, a playground for the childrens, patio table settings, etc.

A review of rare complications of maxillary sinus floor augmentation

  • On, Sung Woon;Cho, Seoung-Won;Yang, Byoung-Eun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.6
    • /
    • pp.351-356
    • /
    • 2019
  • Maxillary sinus floor augmentation (MSFA) is an essential procedure for implant installation in the posterior maxillary area with vertical alveolar bone deficiency. For the past several decades, MSFA has been refined in terms of surgical methods along with technical progress, accumulation of clinical studies, and development of graft materials and surgical instruments. Although some complications in MSFA are inevitable in clinical situations, management of those complications in MSFA has been well established thanks to many clinicians and researchers. Nevertheless, some rare complications may arise and can result in fatal results. Therefore, clinicians should be well aware of such rare situations and complications associated with MSFA. In this review, the authors present several rare complications regarding MSFA, along with corresponding management strategies through a thorough review of the literature.

INFLUENCE OF ROLLING LOADS BY CASTERS ON SEPARATION RESISTANCE OF SUBSTRATE CONCRETE AND SYNTHETIC RESIN FLOOR COATINGS (下地コンクリ-トと合成樹脂塗り床材の耐剝離性に及ぼす キャスタ一の走行荷重の影響)

  • Takamasa, Mikami;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.73-78
    • /
    • 2003
  • In this Study, we examined the influence of characteristics of rolling loads by casters on separation resistance of substrate concrete and synthetic resin floor coating. In the experiment, we first prepared floor samples having substrate concrete of various compressive strength, surface hardness and surface configurations, then put the coated samples to the test of separation resistance with Rolling Caster Loading Machine. Three loading conditions consisted of different kinds of casters, rolling conditions, and coating materials. Consequently, we clarified that the grade of separation resistance varied widely according to the characteristics of substrate concrete and rolling loads.