• 제목/요약/키워드: Floor impact sound

검색결과 264건 처리시간 0.094초

바닥충격음 저감이 가능한 천장 공법 개발 (Development of ceiling construction methods reduced floor impact sound)

  • 김경호;김성훈;류종관;이종인;김용민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.203-207
    • /
    • 2014
  • According to the advanced study, Increase of ceiling air space could cause increase of floor impact sound by air-spring effect. So in this research, we studied the increase of floor impact sound caused by ceiling air space in apartment buildings. At first, we evaluated the change of floor impact noise in the condition of with or without ceiling air-space. And then we installed perforated ceiling systems and glass wool at ceiling area. we expected that perforated ceiling systems could prevent air-spring effect in ceiling space. As a result, ceiling air space caused increasement of floor heavy impact noise about 2~4dB. But perforated ceiling & sound-absorbing materials system could give us reduction of heavy floor impact noise about 3dB. So this systems could be a good alternative to obey national regulations, because it can reduce heavy impact noise additional to floating floor systems.

  • PDF

공동주택 바닥의 구법 변화에 따른 충격음 차단성능에 관한 연구 (A Study on Impact Sound Performance accoring to Variation of Floor Construction Method in Apartment Building)

  • 김순만;지남용;김재훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.97-101
    • /
    • 2003
  • Currently, it is increasing the importance of floor impact sound performance in apartment building due to users' various needs for comfortable residential environments. However, there are little date on floor impact sound performance because Korean apartment building floor is an ON-DOL which is made of several elements. In this study, floor impact sound performance according to variation of floor construction method were investigated. And based on these investigated results, datas can be used to supply constructor and comsumer basis data to estimate floor impact sound performance.

  • PDF

공동주택 바닥의 구법 변화에 따른 충격음 차단성능에 관한 연구 (A Study on Impact Sound Performance according to Variation of Floor Construction Method in Apartment Building)

  • 김순만;지남용;김재훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.97-101
    • /
    • 2003
  • Currently, it is increasing the importance of floor impact sound performance in apartment building due to users' various needs for comfortable residential environments. However, there are little data on floor impact sound performance because Korean apartment building floor is an ON-DOL which is made of several elements. In this study, floor impact sound performance according to variation of floor construction method were investigated. And based on these investigated results, datas can be used to supply constructor and comsumer basis data to estimate floor impact sound performance

  • PDF

바닥충격음에서의 천장구조에 따른 진동절연 효과 (Vibration isolation effect of floor impact sound by ceiling structure)

  • 이성호;정갑철;정진연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.257-260
    • /
    • 2004
  • This study aims to evaluate factors of ceiling structure influencing to the floor impact sound. For this reasons, we measured the vibration of ceiling and the floor impact sound by ceiling structure. The main results from this study are that ceiling structure makes worse to non-ceiling structure for an effect of air layer in heavy-weight floor impact sound. But it has an effect on light-weight floor impact sound about $2\sim8dB$.

  • PDF

임피던스법을 이용한 공동주택 바닥 충격음 차음성능 예측방법에 관한 실험 적 연구(II) - 경량 표준충격원을 중심으로 - (An Experimental Study or the Prediction Method of Floor Impact Sound Insulation Performance in Apartment House Using Impedance Method(II))

  • 김재수;장길수;김선우
    • 소음진동
    • /
    • 제2권1호
    • /
    • pp.21-31
    • /
    • 1992
  • In the previous paper, we report a practical floor impact sound level prediction method for a heavyweight impact source(Tire), soft impact source such as children jumping and running. According to these results, the calculated value and the measured value correspond comparatively well, regardless of differences in the floor structures. And the floor impact sound for a heavyweight impact source, soft source was strongly influenced by structural factors such as floor slab stiffness and peripheral support conditions. But the floor impact sound for a light impact source (Tapping machine), hard impact source was influenced by resilient layers, composed of multi-layer in floor structures. Thus, In this paper, 4 actual floor structures, all with differing resilient layers, were calculated using impedance method. When these calculation values were compared with the measured values, approximately all the values fell with one rank of the sound insulation grade, reference curve(L curve) by the JIS standard. So, a sample of measured values and calculated values from floor structures is presented to show the accuracy and appropriateness of the impedance method in domestic.

  • PDF

신축공동주택의 상하층간 소음 및 진동전달 특성과 층간소음 차단성능에 관한 연구 (Study on the Characteristic of Floor Sound and Vibration Transfer and the Blocking Function of Floor Sound for Newly Built Apartment House)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제24권2호
    • /
    • pp.97-104
    • /
    • 2013
  • This study involves 2 newly built apartment houses which are A with 23 floors as 150 mm slab width and B with 16 floors as 180 mm slab width. The impact was added by tapping and bang machine at the middle floor level of these 2 apartments and the test was arranged in terms of the characteristic of vibration and sound level which transferred to upper or down floors. As a result, impact floor shows the highest value in terms of both sound and vibration level and followed was at down floor of the Impact floor. Also, blocking function for the lightweight and heavyweight floor impact sound level was tested for each room of the apartment A and B including living room, main room, room 1 and 2. As a result, sound blocking function of B apartment was better than that of A and the function was getting worse when the room size is getting smaller.

천장 및 벽구성 방법에 따른 바닥충격음 특성평가 (Evaluation of Floor Impact Sound Performance according to the installation of Ceiling and Wall)

  • 김경우;최현중;양관섭;이승언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.261-264
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the installation of ceiling and wall. In this test, we measured the reduction of impact sound in the case of inserting absorption materials, increasing of the thickness of air layer and using anti-vibration rubber in ceiling, install of absorption materials in wall. The results of this study show that treatment of ceiling and wall have some reduction of the light weight impact sound and heavy weight impact sound.

  • PDF

마감모르타르 물결합재비에 따른 바닥충격음 특성 변화 (Characteristics of the floor impact sound by water to binder ratio of mortar)

  • 이원학;한찬훈
    • 한국음향학회지
    • /
    • 제40권6호
    • /
    • pp.671-677
    • /
    • 2021
  • 본 연구의 목적은 마감모르타르의 물결합재비가 공동주택 바닥충격음에 미치는 영향을 조사하는 것이다. 이를 위하여 동일한 동탄성계수를 지닌 Expanded Polystyrene(EPS) 완충재와 52 %, 66 %, 72 % 의 물결합재비를 가진 모르타르를 활용하여 뜬바닥구조를 시공하였으며, 표준실험동에서 바닥충격음을 측정하였다. 실험결과, 경량충격음에 있어서는 물결합재비 52 % 일 때, 밀도가 높은 관계로 경량충격음 전달특성이 높게 나타났다. 마감모르타르의 물결합재비가 높아지면 완충재 상부층 질량이 낮아지고, 이로 인해 뜬바닥구조의 고유진동수가 63 Hz 대역으로 이동하게 되면서 중량충격음의 음압레벨이 높게 나타났다. 이를 통하여 마감모르타르의 물결합재비가 중량충격음에 미치는 특성을 규명하였다.

Evaluation of Impact Sound Insulation Properties of Light-Framed Floor with Radiant Floor Heating System

  • Nam, Jin-Woo;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.75-84
    • /
    • 2002
  • In order to find out impact insulation properties, various types of current radiant floor heating systems and light-framed floors that are used in light-framed residential buildings were evaluated for two types of impact sources at the same time. Sound Pressure Level (SPL) was different from each impact sources for those spectrum patterns and peaks. In case of light-framed floor framework, the excitation position and the assumed effective vibrating area have effects on sound pressure level but it is not considerable, and Normalized SPL was reduced for each frequency by increasing the bending rigidity of joist. The mortar layer in the radiant heating system had relatively high density and high impedance, therefore, it distributed much of the impact power when it was excited, and reduced the Normalized SPL considerably. Nevertheless, Increasing a thickness of mortar layer had little influence on SPL. Ceiling components reduced the sound pressure level about 5~25 dB for each frequency. Namely, it had excellent sound insulation properties in a range from 200 to 4,000 Hz frequency for both heavy and lightweight impact sources. Also, there was a somewhat regular sound insulation pattern for each center frequency. The resilient channel reduced the SPL about 2~11 dB, irrelevant to impact source. Consequently, current radiant floor heating systems which were established in light-framed residential buildings have quite good impact sound insulation properties for both impact sources.

주거용 건축물의 효율적인 바닥진동해석 (An Efficient Vibration Analysis of the Floors in Residential Building)

  • 김태호;이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.228-235
    • /
    • 2005
  • The floor impact sound insulations are installed frequently for reducing the floor impact sound into the floor slab of the residential buildings in recent years. Therefore the analytical FE model considering the insulations is needed for the sound and vibration analysis of the floor and it is necessary to use a refined finite element model for considering the large number of modes involving in the dynamic responses. So it is very difficult to use FE model because of the tiresome task for constructing the FE model, taking a lot of times for analysis and the impossibility of using the proportional damping. The efficient analysis and modeling method are proposed to the dynamic analysis for the floor with floor impact sound insulations in this study. The floor slabs and finished layers are modeled individually and the spring elements that mean floor impact sound insulations use to connect two parts. The dynamic analysis by the $Newmark-{\beta}$ method is performed to solve the non-proportional damping problem due to the damping coefficient of insulations .

  • PDF