• Title/Summary/Keyword: Floor heating system

Search Result 278, Processing Time 0.028 seconds

Improvement and Standardization of Rural Korean Kitchen Space: Field Survey on Architectural Elements and Facilities(1) (농촌부엌의 개선 및 표준화에 관한 연구(I) -부엌의 물리적 측면을 중심으로-)

  • Chi, Soon;Yoon, Bocha;Yoon, Chung-Sook;Yoo, Young-Hee;Choi, Byoung-Sook
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.1
    • /
    • pp.71-96
    • /
    • 1991
  • The purpose of this study was to identify kitchen space needs in regard to the architectural elements and facilities of rural houses. Three rural villages, Kum-Sung Ri, Young-San 1 Ri, and Yu-Bang 2.5 Ri were selected for this study. The present and past condition of the kitchen space was investigated by the field survey method. The major findings were that: 1) The interior floor materials of the kitchen had been changed from mostly mudplastered floor to linoleum, and the former low level of the kitchen floor had been lifted to the same level of the house plane. This change was made possible by the separation of the cooking from the heating system. 2) Western style kitchen, work centers and kitchen cabinets had been installed in the most of the rural houses. 3) On the basis of this study, the rural Korean kitchen space was classified into six types.

  • PDF

Analysis on Economic Feasibility of Electric Night Storage Heat Pump as a Substitution of a Heater (심야전기보일러 대체 Heat Pump의 경제성 분석)

  • JUNG, H.;JO, J.Y.;Lee, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.119-124
    • /
    • 2011
  • Electric night storage heater was introduced and disseminated for power grid balancing and efficient management of power generation facility. But fuel cost for heating has been increased rapidly while the cost of electricity increased slightly. This abnormal rate system caused peak load in winter at last. To solve this problem, application of an air source heat pump was suggested. In the study, the effect of replacing night heater by heat pump and the economics were analysed. In addition the expectation of prospect of heat pump penetration was simulated based on surveyed and investigated data. As a result, fund supporting as well as institutional backing was needed for effective propagation and return of investment.

Dynamic Simulation of Ground Source Heat Pump with a Vertical U-tube Ground Heat Exchanger (수직형 U자 관 지중 열교환기를 갖는 지열원 열펌프의 동적 시뮬레이션)

  • Lee, Myung-Taek;Kim, Young-Il;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.372-378
    • /
    • 2007
  • GHX (Geothermal Heat Exchanger) design which determines the performance and initial cost is the most important factor in ground source heat pump system. Performance of GHX is strongly dependent on the thermal resistance of soil, grout and pipe. In general, GHX design is based on the static simulation program. In this study, dynamic simulation has been peformed to analyze the variation of system performance for various GHX parameters. Line-source theory has been applied to calculate the variation of ground temperature. The averaged weather data measured during a 10-year period $(1991\sim2000)$ in Seoul is used to calculate cooling and heating loads of a building with a floor area of $100m^2$. The simulation results indicate that thermal properties of borehole play significant effect on the overall performance. Change of grout thermal conductivity from 0.4 to $3.0W/(m^{\circ}C)$ increases COP of heating by 9.4% and cooling by 17%. Change of soil thermal conductivity from 1.5 to $4.0W/(m^{\circ}C)$ increases COP of heating by 13.3% and cooling by 4.4%. Change of GHX(length from 100 to 200 m increases COP of heating by 10.6% and cooling by 10.2%. To study long term performance, dynamic simulation has been conducted for a 20-year period and the result showed that soil temperature decreases by $1^{\circ}C$, heating COP decreases by 2.7% and cooling COP decreases by 1.4%.

Suggestion of Thermal Environment Miniature for Evaluation of Heating Efficiency Based on Thermal Conductivity Measurement Method of Building Materials (건축재료의 열전도율 측정방법에 의한 바닥재 난방효율 평가용 열환경 모형 제안)

  • Jeon, Ji-Soo;Seo, Jung-Ki;Kim, Su-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.3
    • /
    • pp.269-280
    • /
    • 2011
  • Today, global warming is one of main problems all over the world. The cause of the global warming is carbon dioxide outbreak by the rapidly increasing energy use. Therefore, it is necessary to save energy in each industrious field. It was investigated that the half of total energy consumption over the world was used for construction and building. Therefore, the saving of the building energy plays a significant role in decreasing total energy consumption. With the considerable increase in building energy consumption, a green building rating system and certification are required to reduce building energy consumption and $CO_2$ emissions. Of various elements reducing building energy, the thermal conductivity of materials affects the energy consumption as a basic element, which is directly related with reducing energy consumption. In particular, as the thermal conductivity of finishing materials is an important factor to decide heating energy efficiency of floor heating system, the investigation and development are necessary.

Energy Performance Evaluation of Apartment Building in Case of Applying a Blind Integrated Window System (전동 블라인드 내장형 창호시스템 적용에 따른 공동주택 에너지 성능평가 연구)

  • Choi, Gyeong-Seok;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.429-435
    • /
    • 2010
  • Although recently revised building code requires 15~20% increased thermal insulation performance for window systems, since the code is focusing on winter heat loss, it is not satisfactory to contribute on reducing rapidly rising cooling load in summer. Window systems have great impact on building heat gain and loss. Therefore technological development for window system specialized in shading solar gain in summer is an urgent matter. This study evaluates the performance of sun shading and thermal insulation for blind integrated window system. Also, computer simulation evaluates the effect of heating and cooling energy consumption reduction for an individual unit(floor area of $85m^2$) of a multi-family housing. Physibel Voltra, a heat transfer analysis software, was used to analyse the effect of energy consumption reduction, and the energy load was converted to the cost to compare the actual effect of economical benefit.

A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy (지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구)

  • Son, Won-Tug;Park, Kyung-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.628-634
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

Field Survey of Structural and Environmental Characteristics of Pig Houses in the Central Provinces in Korea (우리나라 중부지방 돈사의 구조 및 환경실태조사)

  • 최홍림;송준익;김현태
    • Journal of Animal Environmental Science
    • /
    • v.5 no.1
    • /
    • pp.1-15
    • /
    • 1999
  • The structural and environmental characteristics of typical pig houses in different growth phases were surveyed and analyzed. Based on the data for thirty six selected farms in four provinces, Gyonggi-do, Gangwon-do, Choongnam, and Chonbook, in Central Korea, the goal is to eventually establish standard pig houses of sow and litter, nursery pigs, and growing-finishing pigs. The survey included farm scale, production specialization, structural dimensions of the houses and their ventilation systems, cooling and heating systems, and floor and pit systems related to manure collection. The survey showed 90∼99% of growing-finishing curtain installation rate was lower by 10∼20%. The sidewall curtain system, although popular, is not well insulated which leads to excessive heating costs in winter. Regarding flooring and manure collection system of the house, there was quite a lot variability among provinces, with 30∼80% of the houses installing scraper systems with concrete-slat floors in comparison with 30∼60% using a slurry system. Gangwon-do and Choongbook Chungwoo-goon are the predominant regions that installed a scraper system. A general trend toward enlargement and enclosure of pig houses for all growth phases was gaining popularity in most regions in recent years. A steady shift to three site production from a lumped system was also observed to prevent a disease transfer. The structural design of a standard pig house with its environmental control systems including ventilation and heating/cooling system was suggested for further validation study. In-depth analysis of the survey data is presented in the Results and Discussing section.

An Applicability Estimation of Plastic Vertical Pipes using Electric Fusion Fittings through Measurement (실측을 통한 융착식 플라스틱 입상배관 성능 평가)

  • Park, Yool;Ahn, Young-Chull;Kim, Hyun-Dae;Kim, Jeong-Su;Goark, You-Shik;Kim, Young-Kyoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.595-599
    • /
    • 2013
  • The pipes used in buildings are generally categorized into metallic or plastic materials. Metal pipes, such as copper and stainless steel pipes, are mainly used for water and hot water supply, and for the heating system. However, plastic pipes made of polyethylene and cross-linked polyethylene are used for floor heating, water drainage, and air vent systems. Usually, plastic pipes have thermal demerits, such as high linear expansion coefficients and bending phenomenon by hot water, although the pipes have several merits of light weight, low price, low thermal conductivity, and the comparatively high workability of metal pipes. Therefore, if those kind of demerits are overcome, plastic pipes can be easily accepted for hot water systems. This research is aimed to evaluate the applicability for vertical heating pipes of a plastic pipe system consisting of electric fusion fitting of a conductive carbon compound and propylene random glass fiber pipe, through measurement of the expansion rate and leakage in summer and winter seasons, in the apartment construction field.

A Study of the Anbang Usage and Furniture in the Oiam-Ri Folk Village in Chung-Nam Province (충남 외암리 민속 마을의 안방 사용과 가구 보유 실태 연구)

  • 고도임
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.10
    • /
    • pp.81-90
    • /
    • 1999
  • This study investigated the present traditional Korean farmhouse based on a survey of 30 households from Oiam-Ri folk Village in Chung-Nam Province. This study was primarily concerned with the present housing; the size and plan of the house, lighting and heating, the finishing materials of anbang(the master's bedroom or ondol) and the kinds of fumiture. I was also interested in identifying the socio-demographic and physical variables that influenced the housing, both the ordinary farm households and the descendent of nobility households. Bibliographical studies, cultural approaches, field surveys with tape recordings, and questionnaires were used to collect the data. The results showed that the types of house plans were mixed from the southern region(one-line type) and middle region(courtyard type). The heating system and the fuel for the ondol anbang has changed entirely from wood burning system to oil boiler system. The finishing material of the anbang floor changed from traditional oil paper and straw mats to vinyl flooring. Traditional fumiture and small decor items are disappearing and are being replaced by modem items, but the descendents of the nobility household kept many traditional type of fumiture and small decor items.

  • PDF

On the Characteristics of the Low Velocity Displacement Air-Conditioning System (저속치환 공조시스템의 특성에 대한 연구)

  • Lee, Kye-Cheul;Kim, Dong-Kyu;Kim, Kyoung-Gu;Kwon, Young-Pil
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.493-498
    • /
    • 2001
  • In the low velocity displacement air-conditioning system, the conditioned air is supplied from the diffuser placed on the wall near the floor and vented near the ceiling. This system has some advantages upon the traditional mixing system; the air quality near the people is improved by the displacing action of the system and the energy may be saved by neglecting the cooling or heating load for the upper space of the space above the people. This study is to examine the temperature and velocity distributions in the room and near the diffuser. It is found that the temperature is stratified uniformly all over the room space to show the displacing function of the system.

  • PDF