• Title/Summary/Keyword: Floor Space Index

Search Result 30, Processing Time 0.025 seconds

A Study on Business Value for the Creation of a Private Park regarding Long-term Non-executed Urban Parks - Focused on Long-term Non-executed Neighborhood Park in Gwangju Metropolitan City - (장기미집행 도시공원의 민간공원 조성을 위한 사업성 연구 - 광주광역시 장기미집행 근린공원을 중심으로 -)

  • Kim, Ho-Gyeom;Kim, Dong-Chan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.5
    • /
    • pp.81-91
    • /
    • 2016
  • The study shows solutions of long-term unexecuted urban park and activation plans to facilitate the business promotion of Private Park Developers. This study conducted a feasibility analysis to determine if the business of a special case is applicable. The result of this study is as follows about three long-term unexecuted urban parks in Gwangju Metropolitan City's City Park. First, the three long-term unexecuted urban parks in Gwangju Metropolitan City's City Park are the forest type Neighborhood Parks. Businesses of a special case's park developing cost(average 0.4%) have a relatively low percentage. It is most affected by Land Compensation(average 33.8%) and building construction expenses(average 59.1%). Second, long-term unexecuted urban parks' Land Compensation and building construction expenses seed capital are excessive. The Bongsan Park balance floor space index is 179 percent; a reasonable profit floor space index is 220 percent. The Mareuk Park balance floor space index is 351 percent; a reasonable profit floor space index is 420 percent. The Jungoe Park balance floor space index is 327 percent; a reasonable profit floor space index is 400 percent. Third, to facilitate the business of special cases in deliberating, Bongsan Park should change its second class general residential area. Jungoe Park must change the quasi-residential area and semi-residential area. Mareuk Park must change the general commercial area. In this way, the feasibility of promoting private park projects will be improved.

A Study on the Causes for Space Program of Korea's Museum - With Reference to the Whole Survey of Korea's Museum in Conjunction with Development of Domain-Specific Configuration of Floor Area - (국내 뮤지엄 면적구성 요인에 관한 연구 - 각 영역사이의 면적구성 프로그램 개발을 위한 국내 뮤지엄의 전수조사를 중심으로 -)

  • Hong, Je Hyeong;Moon, Jung Mook
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.2
    • /
    • pp.14-22
    • /
    • 2012
  • In regards to museum planning of Korea, it is mainly depending on overseas cases and relevant domestic books without systematic guideline on the space programme in a museum. Therefore, it is urgently required to establish systematic index as it is incapable of proposing detailed analysis and index in accordance with each element. As various problems occurred due to above reason, total floor area of museum was divided by the area of exhibition section, storage section, research section, and public & other area and its ratio was calculated for statistics targeting 614 museums built after 1990's when many public museums were built with the settlement of local self-governing system and the type of museums was diversified. It was again classified into 4 elements of period, region, scale, and type and then the influence of each element on each section of museum was understood through integrated analysis. First, looking into the space programme in regards to total floor area, the floor area ratio of exhibition section, storage section, and research section decreased and the floor area ratio of public & other area increased with the increase in total floor area. It was because not only rest area but also a space to enjoy various cultures, gaining new experience, and accumulate knowledge is located in public & other area. Second, it was revealed that the ratio of exhibition section and storage section has been decreasing since 1990's and ratio of research section and public & other area has been increasing as they can play various roles such as the education and convenience to satisfy cultural desires of visitor in accordance with current trend. Third, it was proved that floor area ratio of exhibition section is lower than storage section in museums located in highly urbanized region. In addition to this, it was revealed that the floor area ratio of research section is in proportion to the population density. As a result of study, significant relation was displayed in scale, era, and region among 4 elements thus it could be utilized as reference for the space programme of domestic museum planning in the future.

  • PDF

A Study on Development of Publicness Evaluation Index of Indoor Privately Owned Public Space Using Space Syntax - Focused on New York City Indoor Privately Owned Public Spaces - (공간구문론을 활용한 실내공개공지 공공성 평가지표 개발 연구 - 뉴욕시 실내공개공지를 중심으로 -)

  • Kim, Jung Woo;Choi, Jaepil
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.4
    • /
    • pp.83-92
    • /
    • 2020
  • The purpose of this study is to develop a publicness evaluation index for indoor privately owned public spaces (POPS). In order to develop the index, 10 cases of indoor POPS in New York City were analyzed using Visibility Graph Analysis by evaluating its accessibility and visual openness. The results are as follows; (1) Accessibility and openness of indoor POPS were higher compared to other public spaces on the first floor. (2) Cases with high accessibility index installed a higher number of entrances. (3) Cases with high openness index were mostly composed of a glass wall. (4) The publicness index was high when the lobby and the indoor POPS are shared. (5) Atrium types were highly utilized and the evaluation index was also high whereas, linear types were less utilized and the evaluation index was lower.

Analysis of the Determinants on the Annual Average Price Rising Rate for Pyeong of Apartment Housing in Seoul (서울지역 아파트 평당 연평균 가격상승률 결정요인 분석)

  • Kil, Ki-Suck;Lee, Joo-Hyung
    • Journal of the Korean housing association
    • /
    • v.18 no.3
    • /
    • pp.63-72
    • /
    • 2007
  • The purpose of this study is to identify the impact of the building, site, and region characteristic factors on the annual average price rising rate of apartment housing in Seoul. The data were consisted of 272 apartment units in Seoul. A survey included checking the drawing documents and interview with apartment maintenance staffs and real estate agencies from October 2006 to February 2007. Data were analyzed with descriptives, frequency, crosstabs, and linear regression by SPSS/PC for Window. The linear regression model was employed to evaluate the price rising rate in apartment housing. Following results were obtained. The price rising rate for pyeong ($3.3m^2$) of apartment housing was determinated by the district zone, the construction company's brand name, the building age, the building stories, the floor space index, the building-to-land ratio, the green space rate, and the distance from the downtown. Especially, the district zone was the most important factor that affected the price rising of apartment housing in Seoul. Therefore, the policy has to focus to solve the imbalance between autonomous districts with the collaborated tax.

Effect of Floor Space Allowance on Pig Productivity across Stages of Growth: A Field-scale Analysis

  • Lee, Joon H.;Choi, Hong L.;Heo, Yong J.;Chung, Yoon P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.5
    • /
    • pp.739-746
    • /
    • 2016
  • A total of 152 pig farms were randomly selected from the five provinces in South Korea. During the experiment, the average temperature and relative humidity was $24.7^{\circ}C$ and 74% in summer and $2.4^{\circ}C$ and 53% in winter, respectively. The correlation between floor space allowance (FSA) and productivity index was analyzed, including non-productive sow days (NPD), number of weaners (NOW), survival rate (SR), appearance rate of A-grade pork (ARA), and days at a slaughter weight of 110 kg (d-SW) at different growth stages. The objectives of the present study were i) to determine the effect of FSA on the pig productivity index and ii) to suggest the minimum FSA for pigs based on scientific baseline data. For the pregnant sow, NPD could be decreased if pregnant sows were raised with a medium level (M) of FSA (3.10 to $3.67m^2/head$) while also keeping the pig house clean which improves hygiene, and operating the ventilation system properly. For the farrowing sows, the NOW tended to decrease as the FSA increased. Similarly, a high level of FSA (H) is significantly negative with weaner SR of farrowing sows (p-value = 0.017), indicating this FSA tends to depress SR. Therefore, a FSA of 2.30 to $6.40m^2/head$ (very low) could be appropriate for weaners because a limited space can provide a sense of security and protection from external interruptions. The opposite trend was observed that an increase in floor space (> $1.12m^2/head$ leads to increase the SR of growing pigs. For the fattening pigs, H level of FSA was negatively correlated with SR, but M level of FSA was positively correlated with SR, indicating that SR tended to increase with the FSA of 1.10 to $1.27m^2/head$. In contrast, ARA of male fattening pigs showed opposite results. H level of FSA (1.27 to $1.47m^2/head$) was suggested to increase productivity because ARA was most affected by H level of space allowance with positive correlation ($R^2=0.523$). The relationship between the FSA and d-SW of fattening pigs was hard to identify because of the low $R^2$ value. However, the farms that provided a relatively large floor space (1.27 to $1.54m^2/head$) during the winter period showed d-SW was significantly and negatively affected by FSA.

Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations (급기구 형상에 따른 겨울철 실내 온열환경의 비교)

  • Han, Hwa-Taik;Jeong, Young-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

A Study on the Type and Characteristics of the Circulation in Major Space of Museums (박물관 대공간(Major Space)의 동선구조 형식과 특성에 관한 연구)

  • Park, Se-Min;Jung, Sung-Wook
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.209-213
    • /
    • 2008
  • This study is intended to propose a plan index that can be used in the early stage of a museum design based on theoretical review of a major space of a museum including its spatial division, functions and roles. The scope of the study includes functions and roles of circulation in a major space based on precedent studies. The spatial range is limited to a major space among exhibition spaces in a museum. This study analyzes overseas 14 museums. In terms of methodology, the study analyzes circulation in a descriptive way only In the focusing on floor plan and section composition. The results of this study are as follows. First, vertical elements should be critically considered in a circulation plan for functional performance of dimensional circulation distribution in a major space. Second, a plan by location of vertical and horizontal moving elements related to a major space affects a circulation relation more than a connection type between a major space and an exhibition area.

  • PDF

A Study of Models for Marketing Strategy in the Eco-friendly Apartment Housing Using Discriminant Analysis (판별분석을 이용한 친환경 아파트의 마케팅 전략에 관한 연구)

  • Kil, Ki-Suck;Lee, Joo-Hyung
    • KIEAE Journal
    • /
    • v.7 no.3
    • /
    • pp.11-20
    • /
    • 2007
  • The purpose of this study is to analyse the effects of the eco-friendly factors on the apartment housing price rise and to suggest the desirable way of marketing strategy for apartment housing. For the analysis, the data of apartment sites in Seoul had been collected from September 2006 to February 2007. The data consisted of 95 apartment sites in Seoul. Data were analyzed with descriptives, crosstabs, and discriminant analysis by SPSS/PC for Window. Following result was obtained. The eco-friendly apartment housing price rate in Seoul was determined by eco-friendly landscape, green space rate, house unit size, installment sale price per pyeong, floor space index, distance from subway station when it was not considered the impact of building age, construction company's brand, and autonomous districts. Findings of this research can provide valuable information for marketing strategy of housing construction company.

Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate (도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석)

  • Yeo, In-Ae;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.