습식온돌시스템과 전기온돌시스템의 열성능 평가 (Thermal Performance Assessment of Wet Ondol and Electric Ondol System)

  • 한병조;구경완
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.214-220
    • /
    • 2011
  • This paper studies about the assessment of thermal performance between wet ondol system and electric ondol system. Electrical ondol systems shows faster warm-up time, higher floor surface temperature distribution and lower power consumption than wet ondol system. However, if we provide heat regularly wet ondol system which has more heat capacity shows greater thermal storage than electric ondol system. Therefore, we could conclude that wet ondol system which keeps temperature regularly by the thermal storage show better energy-efficiency in case of using the central heating and district heating system. However, Electrical ondol system shows better efficiency in case of using the space during short time or individual heating systems which needs to heat quickly. The Experiment says that electric ondol system has more benefits on timing to reach the set temperature and energy-efficiency than wet ondol system.

실별제어 온수분배기의 유량분배 특성 (A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System)

  • 성순경
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가 (Optimum Collector Area and Economic Evaluation for the Greenhouse Heating)

  • 박이동;김규인
    • 태양에너지
    • /
    • 제2권1호
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF

사각공간내에서의 부분바닥가열에 의한 자연대류에 관한 연구 (Natural Convection in a Rectangular Enclosure with Localized Heating from Below)

  • 한화택
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.287-297
    • /
    • 1995
  • In this study, the geometry consists of a two-dimensional rectangular enclosure with localized heating from below. The size and the location of the heater on the floor has been varied, and one of the vertical walls remains at a low temperature simulating a cold window. The governing equations for momentum, energy and continuity, which are coupled with turbulent equations have been solved using a finite volume method. A low Reynolds number $k-{\varepsilon}$ model has been incorporated to solve the turbulent kinetic energy and the dissipation rate. The heat transfer characteristics and the thermal environmental characteristics of the room have been obtained for various system parameters in a room with a partially heated floor.

  • PDF

문헌에 의해 분석된 한국 전통 온돌(구들)의 역사와 특성 (The History and Characteristics of Korean Traditional Ondol(Gudle) studied through Document Analysis)

  • 김준봉;정상규
    • KIEAE Journal
    • /
    • 제8권6호
    • /
    • pp.3-10
    • /
    • 2008
  • Since fire was founded in the world, human races have invented various heating methods. Ondol is traditional heating method in Korea. It is very the important work to trace the history and characteristics of Ondol which originated and was developed in the Korean peninsula. Especially, the study on Ondol will contribute to improving the present heating methods and predicting future ones. In this paper, we shall study through the analysis of documents such as oriental documents, the document of Choseon dynasty, European documents and American documents. In order to discover the origins of Ondol as one of the excellent heating method all over the world, This study aims at identifying the history and characteristics of Ondol in the Korean peninsula, through document analysis. Results of this study are as follows. 1) The first document about Ondol is Sookyongjoo(水經注), Chinese ancient geography book. Contents recorded in the book include the description related to Ondol at Kwankyesa temple which was located at the border land between Gogooryo(ancient Korea) and the northeast of China. 2) Ondol was popular heating method in Gogooryo(ancient Korea) and it was used in not only Gogooryo but also Silla Kingdom and Beakje Kingdom. Thereafter, it was also used widely in Goryo dynasty and Choseon dynasty. Thereby we know that Ondol has been used as a heating method for a long time in the Korean peninsula. 3) Ondol was covered with a floor paper since the beginning of Choseon dynasty. the paper made room clean and impacted on Korean life style. Because the floor was clean and warm, Koreans thus took off shoes and sat on the floor. 4) Ondol was spreaded to Jeju island in Korea before 16th century but wasn't used widely there. The reason was that Ondol was rare high class heating system and the weather was warm in Jeju island. 5) The overspreading of Ondol caused that poor people built roughly Ondol in the last of Choseon dynasty. So, the quality of Ondol gradually became lower and lower. 6) A westerner was impressed by the novelty of Ondol and Frank Lloyd Wright had played an important role to update and spread Ondol widely all over the world. Hailing Ondol as the ideal heating system, Frank Lloyd Wright began incorporating it in his buildings back in the U.S. and even invented a modified ondol system, using hot water running through pipes instead of the hot exhaust through flues.

공동주택에서 비난방세대가 미치는 열적 영향 (Analysis for Thermal Effect by an Unheated Housing Unit in Apartment)

  • 이은주;구준모;홍희기
    • 설비공학논문집
    • /
    • 제28권1호
    • /
    • pp.42-47
    • /
    • 2016
  • Adjacent housing units suffer inevitable thermal losses if an unheated unit exists in an apartment building. Thermal loss of the units adjoining the unheated apartment can be neglected because the contact area is small and insulators are located in the walls. When insulators are not included in the slab between the upper and lower units, 70% of the heat supplied by an Ondol system may be used in the original unit, but 30% is transferred to the unit on the lower floor. Another 30% can be obtained from the ceiling if the upper floor housing unit is heated. This strong thermal connection is a characteristic of Ondol heating in apartment buildings. When there is an unheated unit, the lower floor unit uses 42.3% more heating energy if there is no insulation and 19.5% if a 35 mm insulator is used as in the current guidelines. Therefore, much thicker insulation should be applied to weaken the thermal connection.

수치해석에 의한 바닥난방공간의 온도변화에 따른 VOCs 방출속도 예측 (A Prediction of VOCs Emission Rate with Temperature Variation in Floor Heating Space by Numerical Analysis)

  • 강동화;최동희;김선숙;김영돈;여명석;김광우
    • 설비공학논문집
    • /
    • 제18권6호
    • /
    • pp.468-476
    • /
    • 2006
  • The paper deals with the numerical analysis of contaminants emission from the material affected by temperature variation in floor heating system. Considering mass transfer and heat transfer theories, a computer program for the analysis of VOCs emission was made. To demonstrate the accuracy of the numerical solution, the prediction results and the measured data were compared. Using this program, emission rates of the materials in the bakeout space and the no bake-out space were compared to estimate the variation of emission rate.

지열을 이용한 공조외기부하저감 시스템에 관한 연구 -지하피트 공간 내의 개구부 형상이 시스템의 열적 특성 및 기류성상에 미치는 영향- (Study on Fresh Air Load Reduction System by Using Geothermal Energy - Effect on Thermal Characteristic arid Air Pattern of System by Opening Configuration -)

  • 손원득;이성
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1092-1100
    • /
    • 2004
  • This paper presents the effect of opening configuration on the thermal behavior and air pattern of earth tube system. The earth tube system is a fresh air load reduction system by using underground double floor space for air-conditioning. In order to analyze the effect of opening configuration on thermal performance of this system and air pattern in underground double floor space quantitatively, we used a model dealing with tree-dimensional profile of wind velocity and temperature in underground double floor space. In conclusion, it is confirmed that heat exchange of a fresh air is mainly performed with upper and lower wall in underground double floor space, and that heat exchange area increased by installing the opening near the wall.

태양열 냉난방 부하산정을 위한 TRNSYS 동적 시뮬레이션 (TRNSYS Dynamic Simulation for Solar Heating and Cooling Load Estimations)

  • 최창용;고상철;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.1-6
    • /
    • 2006
  • This paper presents the heating and cooling load estimations for the library of a cultural center building located in Gwangju Korea by TRNSYS with Type 56 of multi-zone building components. In this study, energy rate control mode is selected and the design temperatures for heating and cooling are specified respectively as 20oC and 26oC. Reading rooms of the library are located on the third floor of the cultural center building, and this third floor space is modeled as the five thermal zones for the TRNSYS simulation. Among the five zones, attention is given to the two zones which are the reading rooms 1 and 2. Since these two zones are to be heated and cooled by the solar thermal system which is planned to be installed in the building, dynamic thermal behaviors of the two zones are analyzed by the heating and cooling load estimations.

온돌난방에서의 자세에 따른 온열생리적 반응의 성차 (Effectsd of posture on physiological thermal responses with Ondol heating system)

  • 신정화;최정화
    • 한국의류학회지
    • /
    • 제22권8호
    • /
    • pp.1020-1031
    • /
    • 1998
  • This study was done to investigate thermal reponses and to obtain the basic information of thermal comfort by sex and posture under the Ondol heating system. Six healthy males and females were exposed to Ondol(Room Temp.: 25$\pm$1$^{\circ}C$, 50$\pm$10%R.H, Floor Temp.:30$\pm$1$^{\circ}C$) on the of posture such as sitting, lying aside and supine on the floor for 30 minutes after 30 minutes' control phase. During the experiment, rectal temperature, skin temperature of 10 areas, local sweating rate, clothing microclimate, subjective sensation were measured. Rectal temperature gradually decreased and mean skin temperature grad-ually increased both male and female in any posture. There was not significant difference between male and female in rectal temperature and mean skin temperature. There were significant difference among the postures in rectal temperature(p<0.001) and mean skin temperature(p<0.001). In lying aside and supine on the floor, appearances of change and changes in rectal temperature and mean skin temperature were large, changes of weight were small. In sitting on the floor, appearances of change and changes in rectal temperature and mean skin temperature were small, changes of weight were large. The trunk skin tem-perature was higher in female than in male, but the extremity skin temperature was higher in male than in female. In sitting on the floor, foot skin temperature(p<0.001) was higher than any other local skin temperature. In supine on the floor, back skin temperature(p<0.001) was higher than any other local skin temperature.

  • PDF