• Title/Summary/Keyword: Floor Heating System

Search Result 278, Processing Time 0.029 seconds

Performance Test and Flue Gas Characteristics of a 350 kW Wood Pellet Boiler (350 kW(300,000 kcal/h)급 우드 펠렛 보일러 운전 특성 및 성능 평가)

  • Kim, Jong-Jin;Kang, Sae-Byul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.167-171
    • /
    • 2009
  • We conducted performance test of a 350 kW class wood pellet boiler installed at a dormitory whose total area is $1,354\;m^2$. The maximum heating capacity of the boiler is 350 kW(300,000 kcal/kg). The wood pellet boiler consists of 3 parts; boiler, hot water storage tank and wood pellet storage tank. In testing the boiler, we shut off hot water utility supply and open up floor heating water system in order to measure exact value of the heating output of the wood pellet boiler. To determine the efficiency and heating output of the wood pellet boiler, we measured mass flow rate of wood pellet, the lower heating value(LHV) of the wood pellet, mass flow rate and temperature of water for floor heating and so on. We measured the mass flow rate of fuel, wood pellet with respect to rotational speed of auger, wood pellet feeding screw. We also measured the flue gas concentration of the wood pellet boiler by using a gas analyser. The result shows that the efficiency of the wood pellet boiler is 80.6% based on lower heating value at 124 kW of heating output. At this condition, O2 concentration of the flue gas is 6.0%, CO and NOx concentrations are 85 and 102 ppm.

  • PDF

A Study on the Strategy to Maintain Optimal Flow-rate and Pressure of the Piping System for Individual Heating (개별 난방방식에서의 배관 내 절정 유량 및 압력유지에 관한 연구)

  • Hong Seok-Jin;Ryu Seong-Ryong;Seok Ho-Tae;Yeo Myoung-Souk;Kim Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.11-18
    • /
    • 2006
  • For the more comfortable thermal environment in residential buildings, it was necessary for variable components like as automatic flow limiting valves and/or balancing valves in hydronic system. And, these components had an effect on flow-rate and pressure inside pipe. In this case, the incompatibility between the design for the heating system and the selection of equipment was the causes of several problems in heating pipe network. In this study, we peformed measurements and analyses of flow rate and pressure inside pipe for radiant floor heating in residential buildings through field surveys and experiments in order to find out the actual conditions and problems. On the basis of this, we suggested the approach for the optimal flow-rate and pressure maintaining inside pipe in individual heating system.

Effect of Supply and Return Locations of a Floor-Supply Cooling System on Thermal Comfort

  • Kim, Young-Il;Kim, Jo-Seph;Yoo, Ho-Seon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.4
    • /
    • pp.37-46
    • /
    • 2001
  • This study numerically investigates thermal comfort of a space cooled by a floor-supply air-conditioning system, in which three different combinations of supply and return locations, one floor-supply/ceiling-return and two floor-supply/floor-return, are treated. A complementary experiment is performed to validate the present numerical analysis, and the prediction agrees favorably with the measured data. In the numerical procedure, a simplified model mimicking the inlet flow through a diffuser is developed for efficient simulations. The calculated results show that the ceiling-return type is far better in terms of thermal comfort than the floor-return ones within the extent of this study, which seems to be caused by effective vertical penetration of the supply air against natural convection. It is also revealed that the arrangement of port locations in the floor-supply/floor-return system has insignificant effect on the cooling performance. For selecting a proper system, other characteristics including the heating performance should be accounted for simultaneously with the present considerations.

  • PDF

Comparison of the Preference for Floor Temperature between Young and Old People in a Winter Season (겨울철 젊은이와 노인의 선호 바닥온도 비교)

  • Ahn, Tae-Kyung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.2
    • /
    • pp.29-36
    • /
    • 2018
  • Even in modern times, we are accustomed to the lifestyle of floor heating system in which the floor is heated for warmth like Ondol, which is the traditional Korean heating system. So, this study was designed to understand the preferred floor temperature through the questionnaires targeting the local residents living in K region. This study would also find out the floor temperature which is preferred by young people and old people through the experiments. The findings are as follows; (1) the old people do not prefer the temperature higher than young people do. It was found that the old people prefer the floor temperature of $40^{\circ}C$ under the air temperature of $20^{\circ}C$ or the floor temperature of $41^{\circ}C$ under the air temperature of $20^{\circ}C$. (2) Both young people and old people tend to like the average skin temperature of $35.5^{\circ}C$. The skin temperature which both young and old people like was $35.2^{\circ}C$ under the air temperature of $24^{\circ}C$ and the skin temperature preferred by young people was $0.4^{\circ}C$ higher than that preferred by under the air temperature of $20^{\circ}C$ (p<0.01). (3) It was found in the questionnaires that the young people prefer the higher floor temperature in terms of age and that the people who get older in their 50s or higher tend to prefer the lower temperature.

An Estimation on Indoor Thermal Environment by Pressurized Plenum Under Floor Air Conditioning System in Heating (난방시 가압식 바닥취출 공조방식의 실내온열환경 평가)

  • Choi, Eun-Hun;Lee, Yong-Ho;Kwon, Young-Cheol;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.92-99
    • /
    • 2010
  • The purpose of this study is to apply pressurized plenum under floor air conditioning system to office areas to understand characteristics of indoor thermal environment based on forms of diffusers. For doing this, the author conducted experiment of module measurement, and based on the results, analyzed indoor temperature distribution and velocity distribution based on direction of diffusion by using Computational Fluid Dynamics(CFD), and estimated the Predicted Mean Vote(PMV) of residents based on forms of diffusers to present the optimal air conditioning of the pressurized plenum under floor air conditioning system in heating. The results of this study are as follows. First, as for forms of diffusers, distributed diffusers rather than conical and grill diffusers were favorable in maintaining $24^{\circ}C$, the established temperature in heating, were active in velocity flowing, and were wide in a radius of diffusion. Second, as for position of pressurizing, the difference between upper and lower temperature was wider in center, lateral, and dispersed pressurizing (in order). As for velocity distribution, the velocity was more increased in lateral, center, and dispersed pressurizing(in order), indicating that dispersed pressurizing maintained uniform thermal environment. Third, as for diffusion direction, mixed direction showed less difference between upper and lower temperature and the difference in velocity between center and lateral part was 0.01m/1, indicating that it maintained uniform thermal environment. Fourth, as for the PMV of residents based on the forms of diffusers, the dispersed type showed(+) values above (0) when applied variably based on the position of diffuser, presenting thermal feeling of "being comfortable" to residents.

Effect of Various Forms of Floor System on Performance of Meat-type Duck and Environments of Duck House (오리사 바닥 형태가 육용오리의 생산성 및 사육환경에 미치는 영향)

  • Bang, Han-Tae;Kim, Dong-Woon;Hwangbo, Jong;Na, Jae-Cheon;Kang, Hwan-Ku;Kim, Min-Ji;Mushtaq, M.M.H.;Parvin, R.;Choi, Hee-Chul;Lee, Sang-Bae;Kang, Min;Kim, Ji-Hyuk
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.253-262
    • /
    • 2013
  • This experiment was conducted to investigate the effects of floor type and heating system on performance, housing environment and health status of ducks reared in three types of duck house (OD : Open floor house-Direct heating system, OF : Open floor house-Floor heating system and LD : Loft type house-Direct heating system). In OF treatment, PVC pipes were installed for heating under concrete floor and covered with litter. In LD treatment, plastic mesh was installed 50 cm above the floor so that duck's droppings can pass through it. Each treatment had four replicates of 25 birds (Cherry Valley duck breed) per pen. There were no significant differences in weight gain and feed intake of ducks for 6 weeks among all treatments. However, feed conversion ratio in LD was significantly higher (p<0.05) than that in OF. No differences were found in carcass charac- teristics, with the exception of abdominal fat weight where OF were higher than the others. Concentrations of $CO_2$ and $NH_3$ gas in OD were higher than those of OF and LD at 3, 4 and 5 weeks. Moisture content in litter of OF was lower than that of OD. In contrast, the amount of dust in the air was higher in OF than in OD. The amount of fuel used for 6 weeks in LD was lower about 21% than that in OD. Some of unusual symptoms were observed in open floor house and loft type house, such as lying, spraddle legged, twisted ankle and legs, wounded sole, or etc. No components of leukocyte and erythrocyte of blood were significantly different among all treatments. The results of this experiment showed that OF and LD systems had no positive effects on performance of meat type commercial duck. However, there were some positive effects of certain house type for the improvement of environmental condition in duck house for hygienic production. In the future, more research on the effect of various facilities and systems for duck house is needed.

Outdoor Reset Control based on Fuzzy Algorithm for Radiant Floor Heating System (퍼지 알고리즘을 기반으로한 바닥복사 난방시스템의 외기보상제어)

  • Choi, Jong-Yo;Baek, Jae-Ho;Kim, Eun-Tai;Lee, Hee-Jin;Park, Mig-Non
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1073-1074
    • /
    • 2008
  • This paper presents outdoor reset control based on fuzzy algorithm for radiant floor heating system. We construct fuzzy system under indoor temperature and outdoor temperature. Simulation is based on TRNSYS with MATLAB. MATLAB is calculating and decide heat source using fuzzy system. Energy efficiency of Fuzzy algorithm is analyzed in term of indoor by TRNSYS System.

  • PDF

Economic analysis of Electric heating appliances (전기난방기구의 경제성 분석 비교)

  • Kim, Yong-Ha;Lee, Kwang-Sung;Nam, Kim-Hyun;Park, Nam-Chul;Woo, Sung-Min;Kim, Mi-Ye;Lim, Hyun-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.448-452
    • /
    • 2006
  • Many kinds of electric heating appliance is used by user interface and desire. Far infrared ray heating system can use a kind of main heating appliance. This paper gives un saving amounts, energy curtailment money and payback period between far infrared ray heating system and existing electric heating appliance - EHP, electric air heater, electric radiator, electric floor heating system - from economy analysis.

  • PDF

An Experimental Study and Transient Simulations of the Radiant Heating Floor Panel by Using Finite Difference Methods (유한차분법(有限差分法)을 이용한 온수온돌(溫水溫突) 바닥구조체(構造體)의 비정상(非正常) 열전달(熱傳達) 해석(解析)과 실험(實驗) 연구(硏究))

  • Sohn, J.Y.;Chung, K.S.;Park, B.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.69-77
    • /
    • 1991
  • "Ondol" have been used in residential buildings for several thousands years in Korea. The traditional "Ondol" heating system of Korea has changed into the radiant heating system with piping embedded in floors or slabs. This study reports the results of transient experiments performed on a radiant heating system and enclosure. The paper presents some details of the thermal response of slab-heated buildings to varying patterns of heat input. Furthermore, I'll compare the results of experimentation with the ones of the numerical simulation by using the explicit and implicit forms of the finite difference methods (FDM). The study has contributed to testify the feasibility of numerical analysis, and the understanding of the transient behavior of radiant heating panels and enclosure exposed to this type of heating system.

  • PDF