• Title/Summary/Keyword: Floor Field Model

Search Result 71, Processing Time 0.02 seconds

An Enhanced Floor Field based Pedestrian Simulation Model (개선된 Floor Field 기반 보행 시뮬레이션 모델)

  • Jun, Chul-Min
    • Journal of Korea Spatial Information System Society
    • /
    • v.12 no.1
    • /
    • pp.76-84
    • /
    • 2010
  • Many pedestrian simulation models for micro-scale spaces as building indoor areas have been proposed for the last decade and two models - social force model and floor field model - are getting attention. Among these, CA-based floor field model is viewed more favourable for computer simulations than computationally complex social force model. However, Kirchner's floor field model has limitations in capturing the differences in dynamic values of different agents and this study proposes an enhanced algorithm. This study improved the floor field model in order for an agent to be able to exclude the influences of its own dynamic values by changing the data structure, and, also modified the initial dynamic value problem in order to fit more realistic environment. In the simulations, real 3D building data stored in a spatial DBMS were used considering future integration with indoor localization sensors and real time applications.

A Study on Comparison of Improved Floor Field Model and Other Evacuation Models (개선된 Floor Field Model과 다른 피난시뮬레이션 모델의 비교 연구)

  • Nam, Hyunwoo;Kwak, Suyeong;Jun, Chulmin
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.3
    • /
    • pp.41-51
    • /
    • 2016
  • In this study, we propose an improved Floor Field Model(FFM) that considers the physical characteristics of pedestrians, i.e., body size, shape, and posture. Also we analyse limits of FFM and features of improved model compared with existing evacuation simulation models. FFM is a typical microscopic pedestrian model using CA, but it does not reflect the physical characteristics of pedestrians. Because of this, FFM is difficult to modeling phenomena such as collision, friction between pedestrians. As a result, FFM calculates a very short evacuation time when compared with the other models. We performed a computational experiment to compare improved model with other models such as FFM, Simulex, Pathfinder in an actual campus building. We carried out a comparison of evacuation aspect according to the change in number of evacuees. Also we compared evacuation aspect by exit. Finally, we confirmed that improved model reflects physical phenomena which were not reflected in FFM. Especially, experimental results were very similar to the Simulex.

A study on building evacuation simulation using Floor Field Model (Floor Field Model을 이용한 건축물의 대피시뮬레이션에 대한 연구)

  • Nam, Hyunwoo;Kwak, Suyeong;Jun, Chulmin
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.2
    • /
    • pp.1-11
    • /
    • 2016
  • The floor field model (hereafter referred to as FFM) is a cellular automata (hereafter referred to as CA)-based walk model used to model pedestrian behavior. Existing studies on FFM conducted experiments with simple structures (that have one room or one obstacle in a room) or relatively complicated structures (that have many rooms). In order to apply the FFM to real buildings, it is necessary to have additional methodologies to process information about the number of rooms, floors, stairs, and exit doors. In particular, it is necessary to process exit doors during this procedure. Exit doors that are recognized by pedestrians are of many types such as exit doors in rooms, stairs connected to corridors, and exit doors in a building. When calculating the static floor field (hereafter referred to as SFF) in the FFM, information about exit doors is needed and simulation results will be different depending on how the SFF is calculated using an exit door among the above-mentioned exit doors. In this study, an XML-format building data model is proposed according to data structures required by the FFM. This study also defines a methodology to process a number of exit doors. Accordingly, this study developed a building data construction and evacuation simulator and simulation experiments were conducted with university campus building.

A PARTICLE TRACKING MODEL TO PREDICT THE DEBRIS TRANSPORT ON THE CONTAINMENT FLOOR

  • Bang, Young-Seok;Lee, Gil-Soo;Huh, Byung-Gil;Oh, Deog-Yeon;Woo, Sweng-Woong
    • Nuclear Engineering and Technology
    • /
    • v.42 no.2
    • /
    • pp.211-218
    • /
    • 2010
  • An analysis model on debris transport in the containment floor of pressurized water reactors is developed in which the flow field is calculated by Eulerian conservation equations of mass and momentum and the debris particles are traced by Lagrange equations of motion using the pre-determined flow field data. For the flow field calculation, two-dimensional Shallow Water Equations derived from Navier Stokes equations are solved using the Finite Volume Method, and the Harten-Lax-van Leer scheme is used for accuracy to capture the dry-to-wet interface. For the debris tracing, a simplified two-dimensional Lagrangian particle tracking model including drag force is developed. Advanced schemes to find the positions of particles over the containment floor and to determine the position of particles reflected from the solid wall are implemented. The present model is applied to calculate the transport fraction to the Hold-up Volume Tank in Advanced Power Reactors 1400. By the present model, the debris transport fraction is predicted, and the effect of particle density and particle size on transport is investigated.

Radiation Characteristics of Heavy-weight Floor Impact Sounds in a Standard Test Building (표준실험동에서 중량충격음의 방사 특성)

  • Yoo, Seung-Yup;Jeong, Yong;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.381-384
    • /
    • 2005
  • The purpose of this study is to develop a prediction model for evaluating heavy-weight floor impact sounds in a test building. Three rooms in the test building (slab thickness In and 240mm), which consist of frame concrete structures were tested and modeled. First, the SPL distribution in the receiving room was analyzed by measuring SPL at 90 positions using a bang machine. Then, a vibration model using finite element method is proposed considering the material properties and boundary conditions. In addition, the result of transient analysis was compared with field measurements using a standard heavy-weight impact source. Through a vibro-acoustic simulation program, an acoustic model evaluating the building elements (reflected wall, nor, window and door) was proposed. Finally, validation of the prediction model was conducted by vibro-acoustic analysis with field measurements of noise radiation characteristics in receiving rooms.

  • PDF

Floor Vibration Analysis of Economic Steel (ES) Beam Using Field Measured Acceleration Responses (진동특성을 고려한 ES-빔 공법의 사용성능 평가)

  • Woo, Jong-Yeol;Park, Soo-Yong;Kim, Min-Jin;Hong, Seong-Wook;Doh, Sun-Boong;Choi, Tae-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.83-84
    • /
    • 2011
  • This study provides floor vibration analysis for a factory constructed by ES-beam using field measured acceleration data. The natural frequencies of the first two modes of floor are extracted from measured data. With this information, a system identification has been performed to produce a numerical model representing existing floor. The peak magnitudes of acceleration for one man walking heel drop load from experiment and numerical model are analyzed using ISO vibration criteria and AIJ vibration performance criteria. The results show that there is no problem in use of ES-beam.

  • PDF

Developing a Cellular Automata-based Pedestrian Model Incorporating Physical Characteristics of Pedestrians (보행자의 물리적 특성을 반영한 CA기반 보행모델)

  • Nam, Hyunwoo;Kwak, Suyeong;Jun, Chulmin
    • Spatial Information Research
    • /
    • v.22 no.2
    • /
    • pp.53-62
    • /
    • 2014
  • The floor field model is the micro pedestrian model based on a cellular automata for modeling pedestrian movement in the interior space using the static and dynamic floor field. It regards a form of pedestrian as square but the actual pedestrian's shape and size are similar to ellipsoid or rectangle. Because of this, we are difficult to give a rotation effect to pedestrians and there is a limit to reflect an impact of clogging and jamming. Also, this model is not able to reflect an impact of a posture and visibility effectively in the pedestrian movement. In this study, we suggest the improved pedestrian model incorporating the actual shape and size of pedestrian. The pedestrian's shape is defined not square but rectangle which is close to the actual body size of Korean. Also, we define the model which is able to represent the impact of clogging and jamming between pedestrians by adding the pedestrian's posture. We develop the simulator for testing the suggested model and study the difference between two models by comparing a number of effects. As a result, we could confirm solving the problem with dynamic value in the existed model and reflecting the panic effect in evacuation situation.

PREDICTION OF FREE SURFACE FLOW ON CONTAINMENT FLOOR USING A SHALLOW WATER EQUATION SOLVER

  • Bang, Young-Seok;Lee, Gil-Soo;Huh, Byung-Gil;Oh, Deog-Yeon;Woo, Sweng-Woong
    • Nuclear Engineering and Technology
    • /
    • v.41 no.8
    • /
    • pp.1045-1052
    • /
    • 2009
  • A calculation model is developed to predict the transient free surface flow on the containment floor following a loss-of-coolant accident (LOCA) of pressurized water reactors (PWR) for the use of debris transport evaluation. The model solves the two-dimensional Shallow Water Equation (SWE) using a finite volume method (FVM) with unstructured triangular meshes. The numerical scheme is based on a fully explicit predictor-corrector method to achieve a fast-running capability and numerical accuracy. The Harten-Lax-van Leer (HLL) scheme is used to reserve a shock-capturing capability in determining the convective flux term at the cell interface where the dry-to-wet changing proceeds. An experiment simulating a sudden break of a water reservoir with L-shape open channel is calculated for validation of the present model. It is shown that the present model agrees well with the experiment data, thus it can be justified for the free surface flow with accuracy. From the calculation of flow field over the simplified containment floor of APR1400, the important phenomena of free surface flow including propagations and interactions of waves generated by local water level distribution and reflection with a solid wall are found and the transient flow rates entering the Holdup Volume Tank (HVT) are obtained within a practical computational resource.

Effective Evacuation based on Elementary School's Floor Layout (초등학교 층별 구성과 비상시 대피효율성의 관계)

  • Kwun, Joon-Bum;Kim, Duk-Su;Kim, Khil-Chae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.23 no.3
    • /
    • pp.3-10
    • /
    • 2016
  • This study compared evacuation effectiveness between the conventional school floor plan and a suggested hypothetical floor plan that was generated by a mathematical model that is commonly applied in the field of industrial engineering. Recent school buildings became much more complicated in floor planning due to the new educational system and modern curriculum than the old days. Nevertheless, architect's approach to floor composition in terms of fire emergency evacuation planning, still has no relation to optimized effective but relies more on a conventional school planning. Therefore, since elementary school buildings are much more likely to be exposed to any fire related events than middle school or high-school, emergency exit effectiveness based on spatial composition has to be seriously evaluated with a scientific method. The algorithm, which acquires the number of persons in each spatial type (node) per floor and the minimum physical distance between spatial types (arc), can propose the most optimized spatial compositing per floor regarding emergency evacuation event. Consequently, this study evaluated elementary school's fire exit effectiveness with the scientific tool and suggested the most reliable spatial composition per floor regarding possibile emergency evacuation event.

Preliminary Study on Generating Three-Dimensional Floor Layout of Construction Sites (건설 시공 현장 3차원 층 단위 레이아웃 생성 모델 기초 연구)

  • Hong, Sungwon;Kim, Taejin;Park, Jiwon;Lee, Soohyoung;Kim, Taehoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.285-286
    • /
    • 2023
  • The visualization of information serves as a valuable tool for facilitating communication and exchange of opinions among stakeholders by conveying information in an intuitive and clear manner. As a preliminary study of visualization for construction field, this study proposed a model for generating three-dimensional floor layout using 360-degree panoramic cameras. The model integrates the layouts by calculating normal vectors of the plane which has openings, and applying translation and rotation matrices between the normal vectors. The results of this study can contribute to improving communication in construction sites by incorporating visualization, and further to the digital transformation of the construction industry.

  • PDF