• Title/Summary/Keyword: Flocculant

Search Result 89, Processing Time 0.022 seconds

Study on the adsorption of Heavy Metals by Chitin, Chitosan, Cellulose and its Composite Beads (Chintin, Chitosan, Cellulose 및 혼합 Beads의 중금속 이온 흡착특성에 관한 연구)

  • 전수진;유병태
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.1-12
    • /
    • 1995
  • Under accelerated industrial developments environment pollution comes out to be very stirious. Especially the ions of heavy metal from wastewater, even if they are minimal, accumulated in ecology circle and do finally injury to human health. The general process for removal of heavy metals include coagulation and following sedimentation, ion -exchange and active carbon adsorption and sedimentation that applicate in popular, needs the expense of coagulant the additional treatment of sludge on the general process of coagulation and sedimentation. It is also a serious problem that the second pollution caused by coagulant. However chelating adsorption that uses natural chelating high- molecular compound has not pollution problem Among chelating high- molecules, the diminishing chitin that contained in crustaceans as crawfish and crab in our country with affluent water resources are easy to get. So it is advantageous to use this ubiquitous material for removing heavy metals because we could reuse natural resource. In this research, the author tested the effectiveness of the adsorption and removal of heavy metal ions by chitin and its derivatives. Chitin and cellulose became beads and used as flocculant, in this test. The results are as follows . First, bead showed higher removal ratio than powder in the comparative test on adsorbents such as chitin, chitosan and cellulose. Secondly, in the variety test by the kinds of adsorbent and time. chitosan bead and cellulose bead that showed the highest removal ratio. One hour need to remove the ions of heavy metal. Thirdly, the results of the adsorption degree test by pH revealed high removal ratio adsorption of chitin, cellulose and chitosan bead in alkalin condition but chitosan bead in acidic condition.

  • PDF

An Experimental Study on Engineering Characteristics of Wet Dredged Soil and Dry Dredged Soil after Chemical Treatment (습윤준설토와 노건조준설토의 약품처리 후 공학적 특성에 관한 실험적 연구)

  • Chang, Yongchai;Park, Kiyoun;Park, Jongcheol;Lee, Ingyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.3
    • /
    • pp.71-76
    • /
    • 2012
  • Since sediment in a stable state is disturbed during the process from sediment in a natural state to dredged soil, the turbidity of water is not good. When the dredged soil settles again, the volume change in the sediment occurs. Coagulant and flocculant are added for turbidity mitigation of the water and faster settling process of suspended solid, and the amount of the substances affects the characteristics of the dredged soil. This study is to investigate the characteristics of the dredged soil depending on the amount of three chemical products added to the wet dredged soil and the dry dredged soil through measuring the suspended solids (SS), volume change and sedimentation velocity. The experimental measurements show that the SS decreased, the volume change rate increased, and the sedimentation velocity increased, as the chemical amount increased. In addition, it was found that the dry dredged soil reacted even with little quantity of the chemicals because derelict and microorganism are removed due to the drying process at $100{\pm}5^{\circ}C$.

A Novel High Rate Flocculator/Filter in Water and Wastewater Treatment (상하수처리를 위한 새로운 고효율 응집/여과 장치)

  • Vigneswaran, S.;Ngo, H.H.;Kwon, Dae-young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.149-154
    • /
    • 2005
  • Conventionally used flocculation tanks require large space and high energy requirement for mixing. Static flocculators using gravel bed filter operate at a lower flow rate ($5-10m^3/m^2{\cdot}h$). Further, the cleaning of this system is difficult. A novel high rate static flocculator/filter developed at UTS packed with buoyant media such as polystyrene, polypropylene has been found to operate at higher filtration rates (30-45 $5-10m^3/m^2{\cdot}h$). They can easily be cleaned with minimal energy. Detailed experiments conducted with an artificial kaolin clay solution show that buoyant media is an excellent static flocculator in producing uniform filterable microflocs (12-15 m) even when it is operated at a high rate of 30-40 m/h. Detailed filtration experiments were conducted in a wastewater treatment plant to treat the biologically treated effluent with a floating media of depth of 120 cm. This filter was able to remove majority of phosphorus and remaining solids. It reduced significantly the fecal coliforms and fecal streptoccoci, thus requiring less amount of chlorine for disinfection. The advantage of this system is the low energy and water requirement for cleaning of filter bed. The periodic backwash adopted 30 seconds air and water and 30 seconds water cleaning every 90 minutes filter operation. Thisis equivalent to 1-2% of filtered water production. Mechanical cleaning system on the other hand, requires very low energy requirement (<1% of filtered water production).

Removal of textile dyes in wastewater using polyelectrolytes containing tetrazole groups

  • Caldera-Villalobos, Martin;Pelaez-Cid, Alejandra-Alicia;Martins-Alho, Miriam-Amelia;Herrera-Gonzalez, Ana-Maria
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2394-2402
    • /
    • 2018
  • Textile dyes are some of the pollutants which have received the most attention because of the large volume of wastewater generated by the textile industry. Removal by means of adsorption is one of the most versatile alternatives to treat these effluents. Even though different adsorbents such as activated carbons and mineral materials have been proposed, polymeric adsorbents are a viable alternative. This work reports for the first time the use of polyelectrolyte PTZ and macroelectrolyte MTZ containing tetrazole groups as adsorbents useful in the textile dyes removal present in aqueous solutions and wastewater. Because of the anionic character of the tetrazole group, MTZ exhibits selective adsorption capabilities for cationic dyes of up to $156.25mg{\cdot}g^{-1}$. The kinetic study of the process of adsorption shows that PTZ and MTZ fit a pseudo second-order model. MTZ also shows utility as a flocculant agent in the treatment of wastewater containing dyes Indigo Blue and Reactive Black. The results showed that PTZ and MTZ may be used in the treatment of wastewater in a process of coagulation-flocculation followed by the treatment by adsorption. This two-stage treatment removed up to 95% of the dye present in the wastewater. As well as removing the dyes, the values for COD, suspended solids, pH, and color of the wastewater decreased, thus significantly improving its quality.

The effect of iron oxide ballasted flocculant on the activated sludge settleability and dewaterability (산화철계 가중응집제가 활성슬러지의 침전성 및 탈수성에 미치는 영향)

  • Yang, Hyeji;Kim, Yongbum;Choi, Younggyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.4
    • /
    • pp.277-284
    • /
    • 2021
  • The ballasted flocculation effects of the mill scale and magnetite on activated sludge were investigated. Both ballasted flocculants (BF) could remarkably improve the sludge settleability in terms of zone settling velocity (ZSV) and sludge volume index (SVI). With the BF dosage of 0.2 to 2.0 g-BF/g-SS, the magnetite particles showed better efficiency on improving settling behavior of activated sludge than the mill scale due to higher surface area and hydrophobic property. The efficiency of SVI30 with magnetite injection was 2.5 to 11.3% higher than mill scale injection and that of the ZSV appreciated from 23.7% to 44.4% for magnetite injection. Averaged floc size of the BF sludge with magnetite dosage (0.5 g-BF/g-SS) was 2.3 times higher than that of the control sludge. Dewaterability of the sludge was also greatly improved by addition of the BF. The specific resistance to filtration (SRF) was reduced exponentially with increasing the dosage of BF. However, the BF's particle size effect on the SRF looks to be marginal. Consequently, for improving the dewaterability, the BF played a physical role to remove the pore water of the biological flocs by intrusive attachment and a chemical role to induce aggregation of the flocs by charge neutralization.

Flocculating Properties of Bioflocculant Biopol32 from Pseudomonas sp. GP32 (Pseudomonas sp. GP32가 생산하는 생물고분자응집제 Biopol32의 응집특성)

  • Lee, Hyun Don;Oh, Nara;Lee, Muyeong Eun;Suh, Hyun Hyo
    • Journal of Life Science
    • /
    • v.27 no.8
    • /
    • pp.930-936
    • /
    • 2017
  • The flocculating properties of bioflocculant Biopol32 produced by Pseudomonas sp. GP32 were investigated for application in industrial wastewater treatment. The major flocculating substance of bioflocculant Biopol32 was identified as polysaccharide. Many anionic flocculants need a counter ion to induce higher flocculating activity. The flocculating activity of bioflocculant Biopol32 was markedly increased by the addition of cationic ions ($Ca^{2+}$, $Al^{3+}$). The flocculating activity of bioflocculant Biopol32 was the most effective when 7.0 mM $CaCl_2{\cdot}2H_2O$ as coflocculant was added. The flocculating activity on the effect of pH and the temperature of the bioflocculant Biopol32 was compared with anionic commercial flocculant (polyacrylamide) and bioflocculant (zooglan from Zoogloea ramigera). In kaolin suspension, the highest flocculating activity was obtained at the bioflocculant Biopol32 concentration of 1.5 mg/l. A high flocculating activity was observed in the pH range of 5.0 to 8.0. The flocculating activity of bioflocculant Biopol32 was sustained up to $60^{\circ}C$, but decreased rapidly at over $70^{\circ}C$. In the batch culture, the charge density of bioflocculant Biopol32 was compared with flocculating activity. The larger the anionic charge density and apparent viscosity of bioflocculant Biopol32, the higher the flocculating activity. Therefore, we confirmed that the flocculating activity and apparent viscosity of bioflocculant Biopol32 was closely related to the charge density of bioflocculant Biopol32.

Environmental Contamination and Best Management of Stone-dust from Quarry Mine (석산개발에 따른 주변 환경오염 및 석분토 처리를 위한 연구)

  • Lee, Pyeong-Koo;Youm, Seung-Jun;Kang, Min-Ju
    • Economic and Environmental Geology
    • /
    • v.43 no.4
    • /
    • pp.315-332
    • /
    • 2010
  • All of the water and stone-dust samples with or without flocculant, in and around quarry mines, were analyzed for total concentrations of heavy metals, cyanide(CN), toxic organic compounds and organic phosphorus. Extraction experiments on stone-dust by EDTA and various pH solutions were also carried out, in order to evaluate the contaminant leaching from the long-term heaped stone-dust within quarry mines. The concentrations of $Cr^{6+}$, Hg, CN, TCE/PCE and total phosphorus in all samples (water and stone-dust) were under detection limits, confirming no environmental contamination from stone-dust in quarry mine areas. Lead and cadmium were not detected in all water samples. Copper and zinc were found in some water samples, and arsenic was detected in a few water samples. But they also showed levels much lower than the drinking water standard. Results of the extraction experiments by EDTA and pH solutions showed that Pb, Cr, Cd, Cu and Zn were leached out in less amounts or under detection limits. Arsenic was detected only at pH 3. From above results, we suggested that environmental contamination by quarry mine development is likely to be minor or negligible.

Chemical Characteristics and Water Dispersible Colloid Content of Jeju Citrus Orchard Soils (제주도 감귤원 토양의 화학적 특성과 물 분산성 콜로이드 함량)

  • Oh, Sang-Sil;Chung, Jong-Bae;Hyun, Hae-Nam
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.2
    • /
    • pp.130-135
    • /
    • 2002
  • Water-dispersible colloids are suspected to facilitate transport of contaminants to groundwater. This study evaluated some soil chemical properties in relation to the stability of colloids in soils of Jeju citrus orchards. Thirty surface soil samples were collected, and pH, organic matter content oxalate-extractable Al and Fe contents, and water-dispersible colloid content were measured. In soils of higher pH, water-dispersible colloid contents were higher. The stability of colloids was found to be significantly promoted at pH above 5$\sim$6. Since organic matter can act as a flocculant organic matter content significantly enhanced the colloid stability. In soils of less than 5% organic C, water-dispersible colloid content was expected to be significantly higher. In soils of higher oxalate-extractable Al and Fe contents, colloids remaining in suspension were lower. This indicated that amorphous oxides and hydroxides play important stabilizing roles in soil structure and can stabilize soil clay against dispersion. Therefore in soils of higher pH, lower organic matter, and lower amorphous clay minerals, the stability of water-dispersible colloids and the potential of colloid-mediated transport of organic chemicals to groundwater could be higher.

Effect of Sludge Conditioner on Dewaterability of Sludge Produced from the Anaerobic Digestion of Food Waste (음식물 쓰레기의 혐기성 소화 슬러지의 응집 및 탈수 특성에 미치는 영향)

  • Park, Jong-Bu;Choi, Sung-Su;Park, Seung-Kook;Hur, Hyung-Woo;Han, Seung-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.3
    • /
    • pp.104-110
    • /
    • 2001
  • In this study, the effect of physico-chemical variables on sludge conditioning was determined to enhance dewaterability of effluent produced from the thermophilic anaerobic digestion of food waste. The gas production rate and methane content during the anaerobic digestion of food waste were $1.1m^3/kg$ VS and 63%, respectively, and the biodegradability of volatile solids was 87.5%. The concentrations of CODcr, TKN and TP of effluent from digestor were 18,500mg/L, 2,800mg/L, and 582mg/L, respectively. At the jar test to screen the flocculant for the dewatering of effluent from digestor, $FeCl_3$ and strong cationic polymer were effective on making flocs in the effluent. The condition of flocculation of effluent were 500mg/L of $FeCl_3$ and 50-100 mg/L of strong cationic polymer, respectively. As the result of measuring of dewaterability potential of effluent to determine the mixing ratio between $FeCl_3$ and polymer by capillary suction time(SCT), optimum condition was 500mg/L of $FeCl_3$ and 80mg/L of strong cationic polymer.

  • PDF