Recently, offshore structures for eco-friendly energy, such as wind and solar power, have been developed to address the problem of insufficient land space; in the case of energy generation, they are designed on a considerable scale. Therefore, the scalability of offshore structures is crucial. The Korea Research Institute of Ships & Ocean Engineering (KRISO) developed multi-linked floating offshore structures composed of floating bodies and connection beams for floating photovoltaic systems. Large-scale floating photovoltaic systems are mainly designed in a manner that expands through the connection between modules and demonstrates a difference in structural response with connection conditions. A fluid-structure coupled analysis was performed for the multi-linked floating offshore structures. First, the wave load acting on the multi-linked offshore floating structures was calculated through wave load analysis for various wave load conditions. The response amplitude operators (RAOs) for the motions and structural response of the unit structure were calculated by performing finite element analysis. The effects of connection conditions were analyzed through comparative studies of RAOs and the response's maximum magnitude and occurrence location. Hence, comparing the cases of a hinge connection affecting heave and pitch motions and a fixed connection, the maximum bending stress of the structure decreased by approximately 2.5 times, while the mooring tension increased by approximately 20%, confirmed to be the largest change in bending stress and mooring tension compared to fixed connection. Therefore, the change in structural response according to connection condition makes it possible to design a higher structural safety of the structural member through the hinge connection in the construction of a large-scale multi-linked floating offshore structure for large-scale photovoltaic systems in which some unit structures are connected. However, considering the tension of the mooring line increases, a safety evaluation of the mooring line must be performed.
The importance of floating photovoltaic systems has recently been emerging to address some issues arising from the installation of conventional ground-mounted photovoltaics. Floating photovoltaics have a few advantages such as cutting down land usage, reducing water evaporation or creating algae. Though there is still necessity to supplement with technical issues: mechanical stability, reliability and long-term durability of floaters and modules. In this paper, we focus the current level of packaging development and introduce research trends that could be applied to next-generation floating photovoltaics.
기존 화석 연료의 고갈 및 환경오염의 문제와 대용량 발전을 위하여 해양환경 및 자원을 이용한 친환경에너지 발전에 대한 연구 및 개발이 증가하고 있으며, 이 중 높은 발전 효율을 가진 해상태양광 발전에 대한 연구가 크게 증가하고 있다. 환경하중이 비교적 약한 내수조건과 달리, 환경하중이 강한 해양에서의 태양광 발전을 위해서는 더 강한 강성의 구조재를 사용해야 한다. 하지만, 구조재의 생산 가능성, 무게를 포함한 구조물 특성 및 경제적 효율성 등의 제약조건이 발생할 수 있다. 따라서, 본 연구에서는 부유식 방파제를 설치함으로써 태양광구조물에 작용하는 파랑하중을 감소시켜 구조재의 강성 강화를 최소화하고자 하였다. 부유식 방파제의 크기 및 구조물로부터의 거리를 변화하여 이에 따른 파랑하중 및 구조재 응력의 감소 정도를 확인하였다. 다수 부력체의 상호간섭을 고려한 파랑하중의 경우, 고차경계요소법(Higher-Order Boundary Element Emthod)을 이용해 산정하였으며, 구조재에 작용하는 응력은 유한요소법(Finite Element Method)을 통해 평가하였다. 각 조건에서의 최대응력을 분석 및 비교함으로써 해상태양광 발전 시스템에 대한 부유식 방파제의 영향을 확인하였으며, 부유식 방파제의 크기가 파랑하중 및 구조재 응력 감소에 큰 영향을 미침을 확인하였다.
In this paper, the effects of environmental variables on the output of the floating photovoltaic water systems, which were installed at the Hapcheon dam in South Korea, were investigated, and the correlations between them were analyzed. The system output was linearly proportional to the solar radiation or irradiance. The output was large in spring and autumn because of high irradiance, but low in the summer when the solar module temperature was high. The influence of the module temperature on the system output was limited in the summer, during which the module temperature change affected the system output more than the change of the irradiance did. In addition, in winter and summer, the module temperature tended to decrease with increasing windspeed, but windspeed did not affect module temperature significantly in the spring and autumn. On the other hand, in winter and spring, the irradiance decreased as the windspeed increased because of movement (or circulation) of the photovoltaic modules.
지락사고 시 지락전류에 의한 전위경도 상승으로부터 인체를 보호하기 위하여 발전소의 주 접지망을 구성한다. 이를 위한 접지설계시 일반적으로 IEEE Std-80-2000(한전설계기준 2602)에 의하여 계산한다. 그러나 이는 수상환경에서 적용하기 힘들어 수상태양광의 접지저항 확보를 위한 접지기술이 명확하지 않다. 그런데 500kW 수상태양광의 모듈표면 및 금속덕트에 정전기가 발생하고 있고, 안정적인 접지확보를 위해서는 수상환경의 접지방식에 대한 구체적인 방안이 필요한 실정이다. 따라서 본 논문에서는 수상환경에서 Wenner 4 전극법으로 대지저항률을 조사.분석하였으며, 현재 운영중인 수상태양광의 접지저항을 국제규격(IEEE std-81)에서 제시하는 전압강하법으로 측정 분석하여 안정적인 접지확보를 위한 수상태양광 접지방안을 제시하였다. 수면 1m 수중의 저항률이 ($126.3969[{\Omega}{\cdot}m]$) 하상의 저항률($97.5713[{\Omega}{\cdot}m]$)보다 대체로 높은 것을 측정 분석되었고, 제시한 접지앵커 접지방안은 수상태양광의 더욱 안정된 접지저항 확보를 위해 경제적으로 가장 효과적인 방법으로 판단되며, 향후 수상태양광 발전의 접지방법으로 활용될 것으로 기대된다.
전 세계 화석 에너지의 사용량은 지속적으로 증가하고 있다. 기존의 화석 에너지 사용 국가뿐만 아니라 개발도상국의 화석 에너지 사용량 또한 증대되면서 유한한 화석 에너지의 고갈에 대한 불안감은 커지고 있다. 또한 화석에너지로 인한 환경오염, 경제적 사회적 문제는 해결해야 할 과제로 남아있다. 태양광은 환경을 해치지 않는 청정에너지이지만, 태양광 발전소를 설치하는 과정에서 여러 문제가 발생한다. 이러한 문제점들을 해결하기 위해 수상 태양광 발전소가 대안으로 떠오르고 있다. 하지만 아직까지 수상 태양광 발전소에 대한 입지 분석이 이루어지지 않고 있다. 본 연구에서는 수상 태양광 발전소의 입지 조건을 지형 및 기후 인자를 이용한 계층분석법을 통해 결과를 분석하였다. 그리고 적합분류표에 따라 각각 인자들의 속성정보에 점수를 부여하고, 여기에 가중치를 곱한 뒤 점수를 시각화하여 분석하였다. 그 결과 경상북도 북부지역의 점수 분포가 남부지역보다 높게 나왔다. 특히 안동시의 안동호와 영양군의 저수지가 최적입지로 추출되었다. 낮은 점수가 나온 곳은 강, 하천의 중심부가 아닌 하천의 경계면이었다. 본 연구를 통해 더욱 정확한 수상 태양광 발전소 입지 분석이 될 것이라고 기대한다.
This paper presents the concept design procedure of a floating-type combined renewable energy platform based on hydrodynamic analyses and is focused on the fatigue design of taut-type mooring lines of the platform. Two types of combined renewable energy platforms are considered: a combination of wind turbine, wave turbine and photovoltaic energy plant and a combination of wind turbine, current turbine and photovoltaic energy plant. The basic configurations are conceptually determined from the understanding of floating offshore plants, while the main dimensions have been determined based on a hydrostatic calculation. Fully coupled hydrodynamic analyses have been carried out to identify the motion characteristics of the floating body and the tension histories of the mooring lines. The tension history is used for the fatigue life prediction based on the rain-flow cycle counting method. For the fatigue life prediction, tension life curves from API and the Palmgren-Miner rule are employed.
Recently, the Korean government announced a plan to activate renewable energies, with focus on clean energy sources such as solar and wind power as the core and the goal of achieving carbon neutrality by 2050. Unlike other photovoltaic (PV) systems, offshore PV installations are advantageous for large-scale expansion because of the ease of securing sites; they also enable lowering the power generation costs based on construction of large-scale power facilities of megawatt class or higher owing to low noise and landscape damage. However, any power generation should proceed with consideration of the special environmental conditions of the ocean. Above all, when installing large-scale facilities, it is important to reduce fluctuations of the structure and secure stability to actively respond to waves. This study is concerned with the development of a floating body technology that actively responds to waves so as to enable commercialization of offshore solar power. A unit platform for research and development on offshore PV generation was installed in the Saemangeum sea, and the structural fluctuations and stability were analyzed to ensure conformity with the major performance indicators.
Yousuf, Hasnain;Khokhar, Muhammad Quddamah;Zahid, Muhammad Aleem;Kim, Jaeun;Kim, Youngkuk;Cho, Eun-Chel;Cho, Young Hyun;Yi, Junsin
Current Photovoltaic Research
/
제8권3호
/
pp.67-78
/
2020
A novel energy production system which has fascinated a wide consideration because of its several benefits that are called floating photovoltaic technology (FPVT). The FPVT system that helps to minimize the evaporation of water as well as an increase in energy production. For the research purposes, both electrical and mechanical structure requires studying of these systems for the development of FPVT power plants. From different points of views, numerous researches have been directed on FPVT systems that have evaluated these systems. The present research article give a logical investigation and up to date review that shows the different features and components of FPVT systems as an energy production system is offered. This articles reviewing the FPVT that gets the attention of the scientists who have the investigational stage and involuntary inspection of FPVT systems in addition to influence of implementing these systems on the water surface. Also, a comprehensive comparison has been constructed that shows the cons and pros of various types of solar systems that could be installed in various locations. In this review, it has been found that solar energy on the roof of a dwelling house generally has a power of 5 to 20 kW, while the inhabitants of commercial buildings generally have a power of 100 kW or more. The average power capacity of a floating solar panel is 11% more of the average capacity of a solar panel installed on the ground. Studies show that 40% of the water in open reservoirs is lost through evaporation. By covering only 30% of the water surface, evaporation can be reduced by 49%. The global solar panel market exceeds 100 GW and the capacity of 104 GW will bring the annual growth rate to 6%. In 2018, the world's total photovoltaic capacity reached 512 GW, an increase of 27% compared to the total capacity and about 55% of the renewable resources newly created that come from photovoltaic systems. It has been also predicted by this review that in 2025 the Solar technology including the FPVT system will increase by 7.38% that is 485.4 GW more of today installed power worldwide.
탄소배출을 감축하기 위한 태양광발전시설은 산림, 농지, 도시, 수상 등에 우후죽순처럼 설치되고 있다. 그러나 태양광발전시설의 설치 이후 관찰자에게 미치는 시각적 선호도 및 심리적 영향에 관한 연구는 부족한 실정이다. 이에 본 연구는 한국 최대 규모의 수상 태양광발전시설 합천댐을 대상으로 근경, 중경, 원경의 시(視)거리에 따라 촬영을 실시하였다. 획득한 이미지를 포토샵을 통해 수상 태양광발전시설을 유무에 대해 비교하여 총 50명 연구 대상자의 뇌파(EEG) 및 설문지 분석을 통해 수상 태양광발전시설 설치 전후의 심리적 변화 및 시각적 선호도를 분석하였다. 결과를 요약하면 다음과 같다. 첫째, 수상 태양광발전시설의 설치에 따라 연구 대상자의 심리적 변화 및 시각적 선호도에 소극적인 영향을 끼치고 있다. 둘째, 수상 태양광발전시설의 설치에 따른 심리적 변화는 연구대상자의 국적/성별/전공과는 상관없이 거의 모든 연구대상자들에게 영향을 끼치는 것으로 판단되었다. 셋째, 수상 태양광발전시설의 설치에 따른 시각적 선호도는 낮으며, 이는 수상 태양광발전시설로 인해 경관의 '친근성' 및 '자연성'에 부정적 영향을 주는 것을 알 수 있다. 또한 이런 시각적 선호도의 변화는 연구대상자의 성별/전공에 따른 차이가 있는 것으로 나타났다. 넷째, 시(視)거리에 따른 수상 태양광발전시설이 관찰자에게 끼치는 심리적 변화 및 시각적 선호도는 근경이 중경과 원경보다 높은 영향을 미치는 것으로 나타났다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.